- Ram 31 or equal dry stripping cabinet
- Solicitation number
- N6852026SIMACQKN000000136
About this file
This is a Questions and Responses document for RFQ N68520-26-Q-1031, a Navy procurement for a dry stripping cabinet to support Fleet Readiness Center Southwest (FRCSW). The Government seeks to procure one Pauli Systems RAM 31 or equivalent dry stripping cabinet capable of processing metal components for LM2500, F/A-18, VRT, and E2D programs. The cabinet must be dedicated to aluminum oxide media use only, feature at least a 900 CFM reclaimer with 2-stage cyclone separator, and include an adjustable media flow valve. The Government does not require ACGIH compliance, HEPA filtration, enhanced LED lighting, enhanced visibility features, soundproof enclosure around the blower, or NSN designation for the equipment.
The Government indicated preference for features that benefit operational efficiency and ease of maintenance, including ergonomic and integrated safety features for extended operator use, commercial off-the-shelf parts for maintainability, an easy-to-use centralized instrument panel, and a long-lasting serviceable cabinet. Notably, the Government prioritized having maintenance personnel already trained for service with on-hand parts and materials availability. The procurement includes an on-site turnkey installation requirement with a technician to perform installation, tooling, system start-up, testing, and appropriate adjustments. The Government currently utilizes photohelic gauges for pressure monitoring. All contractor questions were required to be submitted by 3:00 PM EDT on May 22, 2026, with responses posted as updates to the announcement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 N68520-26-Q-1031
| Question Number | Section | Question | Answer |
| 1 | RFQ | What types of parts or components will be processed in the cabinet? | The Government processes parts needed for our LM2500, F/A 18, VRT, & E2D programs. Essentially any metal component that can fit inside of the cabinet. |
| 2 | RFQ | Will any Hexavalent Chromium-containing coatings or paint be removed during operation? | The Government does not process any parts or components containing Hexavalent Chromium coatings |
| 3 | RFQ | Would operators benefit from enhanced visibility of the work area during blasting operations? | The Government does not require enhanced visiblity of the work area during blasting operations |
| 4 | RFQ | Would high-efficiency LED lighting provide greater value and performance compared to incandescent lighting? | The Government does not require high-efficiency LED lighting during blasting operations |
| 5 | RFQ | Is aluminum oxide the only blast media planned for use? | The Government will dedicate this blast cabinet for aluminum oxide use only |
| 6 | RFQ | Is an ACGIH-compliant cabinet required for this application? | The Government does not require an ACGIH compliant cabinet |
| 7 | RFQ | Will the cabinet operate in an enclosed environment requiring HEPA filtration? | The Government does not operate the cabinet in an enclosed environment requiring HEPA filtration |
| 8 | RFQ | Would ergonomic and integrated safety features be beneficial to operators during extended use? | The Government could benefit from ergonomic and integrated safety features for extended operator use |
| 9 | RFQ | Would the Government benefit from a long-lasting and serviceable blast cabinet? | The Government could benefit from a long-lasting and serviceable blast cabinet |
| 10 | RFQ | Should the parts and pieces of the cabinet be commercial off the shelf for maintainability? | The Government requires that parts necessary for the operation of the cabinet be commercial off the shelf for maintanability |
| 11 | RFQ | Are Photohelic gauges that detect filter loading valuable to the operators? | The Government currently utilizes photohelic gauges for pressure monitoring |
| 12 | RFQ | Would the government prefer an easy to service and maintain blast cabinet? | The Government would benefit from an easy to service and maintain blast cabinet. More importantly, the Government would benefit from having a cabinet where maintenance personnel is already trained for service and equipped with on-hand parts and materials. |
| 13 | RFQ | Would the operators benefit from an easy-to-use instrument panel where all the blast cabinet controls are located in one location? | The Government could benefit from an easy-to-use instrument panel where the controls are located in one location |
| 14 | RFQ | Is there other work going on in the surrounding area that would benefit from the blast cabinet having a soundproof enclosure around the blower? | The Government does not require the blast cabinet to have a soundproof enclosure around the blower |
| 15 | RFQ | Would the blast cabinet being listed with an NSN number be beneficial in the funding and acquisition process? | The Government does not require the equipment to have an NSN number for funding and acquisition purposes |