This document contains Questions and Answers related to Solicitation N6660424Q0545 for the fabrication of a Calibration Cage Frame. The solicitation is a Firm Fixed Price commercial item purchase for a Calibration Cage Frame to be delivered to the Naval Undersea Warfare Center Division in Newport, Rhode Island. The solicitation is set aside for small businesses, with a NAICS code of 334513 and a size standard of 750 employees. The key details provided in the Questions and Answers include: the intended use of multiple aluminum perforated sheets to cover the required size, acceptance of a two-piece loop with weld for the top and bottom hoop, and a revised tolerance of +/- 0.125 inches which is acceptable. The solicitation has a response due date of June 17, 2024, with the Government intending to award a single Purchase Order on a Lowest Price, Technically Acceptable basis.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| II.D.ii. Calibration Cage Dwg Pkg Distro A ACF-4100.pdf | ||
| II.D.i. Combined Synopsis N6660424Q0545.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS AND ANSWERS N6660424Q0545
Item 3 call out is McMaster-Carr #932T318 0.032" Thick, 0.1875" Hole Diameter,51% Open
Area, Aluminum Perforated Sheet. The size is 48" x 48" and not large enough to cover the outside height of 64" as shown on sheet #1.
Intent is to use multiple sheets as needed and attach with tack weld.
For the top and bottom hoop, the bar is too long to have a single piece construction. In addition there is no weld shown to make a continuous loop. We are proposing a 2 piece loop with welds.
Two-piece loop with weld is acceptable.
The welded cage from tolerances are shown as + .01 inches. This tolerance is too tight to hold on such a large weldment. Proposes a +.125 inch tolerance.
+0.125 inch tolerance is acceptable.