N6449824R4004.pdf
PDF 1 MB Posted
- Attached to
- Human Machine Interface (HMI) Equipment Federal contract opportunity
- Solicitation number
- N6449824R4004
About this file
This document is a Solicitation for a federal contract opportunity issued by the Naval Surface Warfare Center Philadelphia Division (NSWCPD) for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machine Interfaces (HMI) equipment.
The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, and associated hardware and peripheral equipment to be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships. The contract has a 5 year ordering period with a minimum order value of $100,000. The solicitation is set aside for small businesses and the incumbent contractor is NAG Marine (Cage Code: 1PL37). Offers are due by 5:00 PM on April 22, 2024. Pricing is Firm Fixed Price. The document provides detailed technical specifications and requirements for the equipment.
View the file
Other files for this federal contract opportunity
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
N6449824R4004 22-Mar-2024
b. TELEPHONE NUMBER 8. OFFER DUE DATE/LOCAL TIME
05:00 PM 22 Apr 2024
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
N644989. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
PATRICK J MCCARRY
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED OR X
SMALL BUSINESSX
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
NAVAL SURFACE WARFARE CENTER PHILA
CODE 0222, PATRICK MCCARRY
PATRICK.J.MCCARRY.CIV@US.NAVY.MIL
5001 SOUTH BROAD STREET
PHILADELPHIA PA 19112
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE 16. ADMINISTERED BY
SEE SCHEDULE
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
1,250
NAICS:
334111
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF271
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
Section SF 1449 - CONTINUATION SHEET
GENERAL INFORMATION
General Information
Contract Type: Firm Fixed Price (FFP) IDIQ Period of Performance: 5 Year Ordering Period In accordance with clause 52.216-22 (b), the contract “minimum” order is $100,000
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 50 24" Operator Interface Panel (OIP) w/ It
FFP
Base: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket FOB: Destination
NET AMT
0002 100 Connector Kit for Item 0001
FFP
Base: Connector Kit for Item 0001 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.
0003 110 24" Flat Panel Display (FPD)
FFP
Base : 24" Flat Panel Display (FPD) (for single & dual monitor consoles)
0004 25 42" Flat Panel Display (FPD) w/bracket
FFP
Base: 42" Flat Panel Display (FPD) w/bracket
0005 50 Connector Kit for Item 0004
FFP
Base:Connector Kit for Item 0004 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0006 25 46" Flat Panel Display (FPD) w/bracket
FFP
Base: 46" Flat Panel Display (FPD) w/bracket
0007 50 Connector Kit for Item 0006
FFP
Base: Connector Kit for Item 0006
0008 225 Sealed CPU
FFP
Base: Sealed CPU
0009 225 Power Adapter for Item 0008
FFP
Base: Power Adapter for Item 0008 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0010 10 Sit Down Dual Monitor Console (SDDM)
FFP
Base: Sit Down Dual Monitor Console (SDDM)
0011 20 Connector Kit for Item 0010
FFP
Base: Connector Kit for Item 0010 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0012 10 Stand Up Dual Monitor Console (SUDM)
FFP
Base: Stand Up Dual Monitor Console (SUDM)
0013 20 Connector Kit for Item 0012
FFP
Base: Connector Kit for Item 0012 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0014 35 Sit Down Single Monitor Console (SDSM)
FFP
Base: Sit Down Single Monitor Console (SDSM)
0015 70 Connector Kit for Item 0014
FFP
Base: Connector Kit for Item 0014 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0016 10 Stand Up Single Monitor Console (SUSM)
FFP
Base: Stand Up Single Monitor Console (SUSM)
0017 20 Connector Kit for Item 0016
FFP
Base: Connector Kit for Item 0016 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0018 50 Operator Interface Computer (OIC)
FFP
Base: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
0019 100 Connector Kit for Item 0018
FFP
Base: Connector Kit for Item 0018 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0020 50 Operator Interface Computer (OIC)
FFP
Base:Operator Interface Computer (OIC) CPU Enclosure 2
0021 50 Mounting Bracket for Item 0020
FFP
Base: Mounting bracket for Item 0020 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0022 100 Connector Kit for Item 0020
FFP
Base: Connector Kit for Item 0020 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0023 50 Rugged Keyboard/trackball/mounting brack
FFP
Base: Rugged Keyboard/trackball/mounting bracket
0024 5 Rack Mounted Uninterruptable Power Suppl
FFP
Base: Rack Mounted Uninterruptable Power Supply (UPS)
0025 20 Tower-Style Uninterruptable Power Supply
FFP
Base: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
0026 20 UPS Foundation
FFP
Base: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0027 50 UPS Connector Kit - Input
FFP
Base: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0028 100 UPS Connector Kit - Output
FFP
Base: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0029 20 Mod kit for console RGB video connection
FFP
Base: Mod kit for console RGB video connection
0030 20 Mod kit for console ABT (Automatic Bus T
FFP
Base: Mod kit for console ABT (Automatic Bus Transfer) switch
0031 50 24" Operator Interface Panel (OIP) w/ It
FFP
Year 2: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket
0032 100 Connector Kit for Item 0031
FFP
Year 2: Connector Kit for Item 0031 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0033 110 24" Flat Panel Display (FPD)
FFP
Year 2:24" Flat Panel Display (FPD) (for single & dual monitor consoles)
0034 25 42" Flat Panel Display (FPD) w/bracket
FFP
Year 2: 42" Flat Panel Display (FPD) w/bracket
0035 50 Connector Kit for Item 0034
FFP
Year 2:Connector Kit for Item 0034 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0036 25 46" Flat Panel Display (FPD) w/bracket
FFP
Year 2: 46" Flat Panel Display (FPD) w/bracket
0037 50 Connector Kit for Item 0036
FFP
Year 2: Connector Kit for Item 0036 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0038 225 Sealed CPU
FFP
Year 2: Sealed CPU
0039 225 Power Adapter for Item 0038
FFP
Year 2: Power Adapter for Item 0038 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0040 10 Sit Down Dual Monitor Console (SDDM)
FFP
Year 2: Sit Down Dual Monitor Console (SDDM)
0041 20 Connector Kit for Item 0040
FFP
Year 2: Connector Kit for Item 0040 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0042 10 Stand Up Dual Monitor Console (SUDM)
FFP
Year 2: Stand Up Dual Monitor Console (SUDM)
0043 20 Connector Kit for Item 0042
FFP
Year 2: Connector Kit for Item 0042 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0044 35 Sit Down Single Monitor Console (SDSM)
FFP
Year 2: Sit Down Single Monitor Console (SDSM)
0045 70 Connector Kit for Item 0044
FFP
Year 2: Connector Kit for Item 0044 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0046 10 Stand Up Single Monitor Console (SUSM)
FFP
Year 2: Stand Up Single Monitor Console (SUSM)
0047 20 Connector Kit for Item 0046
FFP
Year 2: Connector Kit for Item 0046 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0048 50 Operator Interface Computer (OIC)
FFP
Year 2: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
0049 100 Connector Kit for Item 0048
FFP
Year 2: Connector Kit for Item 0048 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0050 50 Operator Interface Computer (OIC)
FFP
Year 2:Operator Interface Computer (OIC) CPU Enclosure 2
0051 50 Mounting Bracket for Item 0050
FFP
Year 2: Mounting bracket for Item 0050 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0052 100 Connector Kit for Item 0050
FFP
Year 2: Connector Kit for Item 0050 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0053 50 Rugged Keyboard/trackball/mounting brack
FFP
Year 2: Rugged Keyboard/trackball/mounting bracket
0054 5 Rack Mounted Uninterruptable Power Suppl
FFP
Year 2: Rack Mounted Uninterruptable Power Supply (UPS)
0055 20 Tower-Style Uninterruptable Power Supply
FFP
Year 2: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
0056 20 UPS Foundation
FFP
Year 2: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0057 50 UPS Connector Kit - Input
FFP
Year 2: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0058 100 UPS Connector Kit - Output
FFP
Year 2: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0059 20 Mod kit for console RGB video connection
FFP
Year 2: Mod kit for console RGB video connection
0060 20 Mod kit for console ABT (Automatic Bus T
FFP
Year 2: Mod kit for console ABT (Automatic Bus Transfer) switch
0061 50 24" Operator Interface Panel (OIP) w/ It
FFP
Year 3: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket
0062 100 Connector Kit for Item 0061
FFP
Year 3: Connector Kit for Item 0061 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0063 110 24" Flat Panel Display (FPD)
FFP
Year 3: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)
0064 25 42" Flat Panel Display (FPD) w/bracket
FFP
Year 3: 42" Flat Panel Display (FPD) w/bracket
0065 50 Connector Kit for Item 0064
FFP
Year 3:Connector Kit for Item 0064 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0066 25 46" Flat Panel Display (FPD) w/bracket
FFP
Year 3: 46" Flat Panel Display (FPD) w/bracket
0067 50 Connector Kit for Item 0066
FFP
Year 3: Connector Kit for Item 0066 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0068 225 Sealed CPU
FFP
Year 3: Sealed CPU
0069 225 Power Adapter for Item 0068
FFP
Year 3: Power Adapter for Item 0068 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0070 10 Sit Down Dual Monitor Console (SDDM)
FFP
Year 3: Sit Down Dual Monitor Console (SDDM)
0071 20 Connector Kit for Item 0070
FFP
Year 3: Connector Kit for Item 0070 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0072 10 Stand Up Dual Monitor Console (SUDM)
FFP
Year 3: Stand Up Dual Monitor Console (SUDM)
0073 20 Connector Kit for Item 0072
FFP
Year 3: Connector Kit for Item 0072 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0074 35 Sit Down Single Monitor Console (SDSM)
FFP
Year 3: Sit Down Single Monitor Console (SDSM)
0075 70 Connector Kit for Item 0074
FFP
Year 3: Connector Kit for Item 0074 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0076 10 Stand Up Single Monitor Console (SUSM)
FFP
Year 3: Stand Up Single Monitor Console (SUSM)
0077 20 Connector Kit for Item 0076
FFP
Year 3: Connector Kit for Item 0076 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0078 50 Operator Interface Computer (OIC)
FFP
Year 3: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
0079 100 Connector Kit for Item 0078
FFP
Year 3: Connector Kit for Item 0078 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0080 50 Operator Interface Computer (OIC)
FFP
Year 3:Operator Interface Computer (OIC) CPU Enclosure 2
0081 50 Mounting Bracket for Item 0080
FFP
Year 3: Mounting bracket for Item 0080 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0082 100 Connector Kit for Item 0080
FFP
Year 3: Connector Kit for Item 0080 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0083 50 Rugged Keyboard/trackball/mounting brack
FFP
Year 3: Rugged Keyboard/trackball/mounting bracket
0084 5 Rack Mounted Uninterruptable Power Suppl
FFP
Year 3: Rack Mounted Uninterruptable Power Supply (UPS)
0085 20 Tower-Style Uninterruptable Power Supply
FFP
Year 3: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
0086 20 UPS Foundation
FFP
Year 3: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0087 50 UPS Connector Kit - Input
FFP
Year 3: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0088 100 UPS Connector Kit - Output
FFP
Year 3: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0089 20 Mod kit for console RGB video connection
FFP
Year 3: Mod kit for console RGB video connection
0090 20 Mod kit for console ABT (Automatic Bus T
FFP
Year 3: Mod kit for console ABT (Automatic Bus Transfer) switch
0091 50 24" Operator Interface Panel (OIP) w/ It
FFP
Year 4: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket
0092 100 Connector Kit for Item 0091
FFP
Year 4: Connector Kit for Item 0091 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0093 110 24" Flat Panel Display (FPD)
FFP
Year 4: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)
0094 25 42" Flat Panel Display (FPD) w/bracket
FFP
Year 4: 42" Flat Panel Display (FPD) w/bracket
0095 50 Connector Kit for Item 0094
FFP
Year 4:Connector Kit for Item 0094 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0096 25 46" Flat Panel Display (FPD) w/bracket
FFP
Year 4: 46" Flat Panel Display (FPD) w/bracket
0097 50 Connector Kit for Item 0096
FFP
Year 4: Connector Kit for Item 0096 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0098 225 Sealed CPU
FFP
Year 4: Sealed CPU
0099 225 Power Adapter for Item 0098
FFP
Year 4: Power Adapter for Item 0098 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0100 10 Sit Down Dual Monitor Console (SDDM)
FFP
Year 4: Sit Down Dual Monitor Console (SDDM)
0101 20 Connector Kit for Item 0100
FFP
Year 4: Connector Kit for Item 0100 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0102 10 Stand Up Dual Monitor Console (SUDM)
FFP
Year 4: Stand Up Dual Monitor Console (SUDM)
0103 20 Connector Kit for Item 0102
FFP
Year 4: Connector Kit for Item 0102 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0104 35 Sit Down Single Monitor Console (SDSM)
FFP
Year 4: Sit Down Single Monitor Console (SDSM)
0105 70 Connector Kit for Item 0104
FFP
Year 4: Connector Kit for Item 0104 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0106 10 Stand Up Single Monitor Console (SUSM)
FFP
Year 4: Stand Up Single Monitor Console (SUSM)
0107 20 Connector Kit for Item 0106
FFP
Year 4: Connector Kit for Item 0106 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0108 50 Operator Interface Computer (OIC)
FFP
Year 4: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
0109 100 Connector Kit for Item 0108
FFP
Year 4: Connector Kit for Item 0108 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0110 50 Operator Interface Computer (OIC)
FFP
Year 4:Operator Interface Computer (OIC) CPU Enclosure 2
0111 50 Mounting Bracket for Item 0110
FFP
Year 4: Mounting bracket for Item 0110 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0112 100 Connector Kit for Item 0110
FFP
Year 4: Connector Kit for Item 0110 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0113 50 Rugged Keyboard/trackball/mounting brack
FFP
Year 4: Rugged Keyboard/trackball/mounting bracket
0114 5 Rack Mounted Uninterruptable Power Suppl
FFP
Year 4: Rack Mounted Uninterruptable Power Supply (UPS)
0115 20 Tower-Style Uninterruptable Power Supply
FFP
Year 4: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
0116 20 UPS Foundation
FFP
Year 4: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0117 50 UPS Connector Kit - Input
FFP
Year 4: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0118 100 UPS Connector Kit - Output
FFP
Year 4: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0119 20 Mod kit for console RGB video connection
FFP
Year 4: Mod kit for console RGB video connection
0120 20 Mod kit for console ABT (Automatic Bus T
FFP
Year 4: Mod kit for console ABT (Automatic Bus Transfer) switch
0121 50 24" Operator Interface Panel (OIP) w/ It
FFP
Year 5: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket
0122 100 Connector Kit for Item 0121
FFP
Year 5: Connector Kit for Item 0121 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0123 110 24" Flat Panel Display (FPD)
FFP
Year 5: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)
0124 25 42" Flat Panel Display (FPD) w/bracket
FFP
Year 5: 42" Flat Panel Display (FPD) w/bracket
0125 50 Connector Kit for Item 0124
FFP
Year 5:Connector Kit for Item 0124 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0126 25 46" Flat Panel Display (FPD) w/bracket
FFP
Year 5: 46" Flat Panel Display (FPD) w/bracket
0127 50 Connector Kit for Item 0126
FFP
Year 5: Connector Kit for Item 0126 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0128 225 Sealed CPU
FFP
Year 5: Sealed CPU
0129 225 Power Adapter for Item 0128
FFP
Year 5: Power Adapter for Item 0128 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0130 10 Sit Down Dual Monitor Console (SDDM)
FFP
Year 5: Sit Down Dual Monitor Console (SDDM)
0131 20 Connector Kit for Item 0130
FFP
Year 5: Connector Kit for Item 0130 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0132 10 Stand Up Dual Monitor Console (SUDM)
FFP
Year 5: Stand Up Dual Monitor Console (SUDM)
0133 20 Connector Kit for Item 0132
FFP
Year 5: Connector Kit for Item 0132 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0134 35 Sit Down Single Monitor Console (SDSM)
FFP
Year 5: Sit Down Single Monitor Console (SDSM)
0135 70 Connector Kit for Item 0134
FFP
Year 5: Connector Kit for Item 0134 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0136 10 Stand Up Single Monitor Console (SUSM)
FFP
Year 5: Stand Up Single Monitor Console (SUSM)
0137 20 Connector Kit for Item 0136
FFP
Year 5: Connector Kit for Item 0136 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0138 50 Operator Interface Computer (OIC)
FFP
Year 5: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
0139 100 Connector Kit for Item 0138
FFP
Year 5: Connector Kit for Item 0138 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0140 50 Operator Interface Computer (OIC)
FFP
Year 5:Operator Interface Computer (OIC) CPU Enclosure 2
0141 50 Mounting Bracket for Item 0140
FFP
Year 5: Mounting bracket for Item 0140 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0142 100 Connector Kit for Item 0140
FFP
Year 5: Connector Kit for Item 0140 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0143 50 Rugged Keyboard/trackball/mounting brack
FFP
Year 5: Rugged Keyboard/trackball/mounting bracket
0144 5 Rack Mounted Uninterruptable Power Suppl
FFP
Year 5: Rack Mounted Uninterruptable Power Supply (UPS)
0145 20 Tower-Style Uninterruptable Power Supply
FFP
Year 5: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
0146 20 UPS Foundation
FFP
Year 5: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0147 50 UPS Connector Kit - Input
FFP
Year 5: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0148 100 UPS Connector Kit - Output
FFP
Year 5: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD
0149 20 Mod kit for console RGB video connection
FFP
Year 5: Mod kit for console RGB video connection
0150 20 Mod kit for console ABT (Automatic Bus T
FFP
Year 5: Mod kit for console ABT (Automatic Bus Transfer) switch
0151 1 Lot Technical Data
FFP
FFP
Refer to Contract Data Requiremetns List (CDRL) DD Form 1423 and Contract Specifications. Not Separately Priced (NSP)
SECTION C
Technical Specifications for Human Machine Interface (HMI) Equipment
1.0 INTRODUCTION
1.0.1 The Naval Surface Warfare Center Philadelphia Division (NSWCPD) is a Department of Defense entity responsible for research and development, test and evaluation, engineering and fleet support organization for the Navy’s ships, submarines, military watercraft and unmanned vehicles. This requirement is for NSWCPD Code 516, which is responsible for machinery controls engineering support and advanced damage control systems support.
1.1 BACKGROUND
The requirement is in support of a contract for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machined Interfaces (HMI). These HMIs shall be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships to control and monitor multiple systems. The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, associated hardware and peripheral equipment used to display and control system specific information.
1.2 SCOPE OF WORK
Please see section 3.0 for a full listing of required equipment
2.0 APPLICABLE DOCUMENTS
Not applicable
3.0 REQUIREMENTS
3.1 Contractor shall provide items in Schedule B upon issuance of task orders
3.2 Environmental Qualification Testing (EQT)
All equipment shall meet or exceed the following EQT standards:
Equipment Environmental Requirements Shock MIL-S-901D Grade A, Class 1, Type A – Deck and
Hull Mounting Vibration MIL-STD-167-1A, Type 1 EMI MIL-STD-461G (surface ship, below deck) EMI (Rugged Keyboard) MIL-STD-461F (surface ship, below deck) High Operating Temperature MIL-STD-810G Method 501.6, Procedure II
(Test to maximum days suggested in MIL-STD for max temperature and max load)
High Storage Temperature MIL-STD-810G Method 501.6, Procedure I Low Operating Temperature MIL-STD-810G Method 502.6, Procedure II Low Storage Temperature MIL-STD-810G Method 502.6, Procedure I Humidity MIL-STD-810G, Method 507.6 (0-95% non-condensing) Power MIL-STD-1399 SECTION 300B Grounding and Bonding MIL-STD-1310G Human Factors MIL-STD-1472G
3.3 Equipment Technical Specifications
All equipment shall meet or exceed the following technical specifications:
24” Operator Interface Panel (OIP) w/ Sealed CPU and Mounting Bracket General Touchscreen shall function properly with a Flash Fire Glove.
General
Shall include Section 3.1 item 8 removable Sealed CPU.
General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure Dust and water resistance shall be IP65 (Reference IEC 60529).
Door Shall consist of a complete integral unit with a hinged bezel for maintenance efforts.
Door Bezel shall be able to be physically secured using a hasp with lock.
Cooling Shall have passive cooling (no moving parts).
Physical Security Shall be lockable.
Display Type Liquid Crystal Display (LCD) Backlight Light Emitting Diode (LED) backlight Pointer Shall contain a bezel mounted pointer with right & left click.
Touch Screen single touch resistive 5+ wire
Resolution 1920x1080 Aspect Ratio 16:9 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical Brightness 0-300 nits
Brightness Control 0-100% (Dimmable to full dark).
Colors 16 Million
Contrast Ratio 5000:1
Material 0.125” Aluminum 5052-H32 Alloy. Chemically treated IAW MIL-DTL 5541, Type II, Class 1A. Material shall not contain hexavalent chromium.
Weight Not to Exceed (NTE) 60lbs with mount bracket.
Max Power Consumption
NTE 100W
Dimensions NTE 26.0” (W) x 18” (H) x 12.0” (D) (with mounting) Mounting Bracket Tilt Angle: 15 ° Up/Down: Material: .187” Aluminum Plate USB Two (2) USB 3.0 external I/O ports External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
Fiber Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or
1000BaseSX native fiber NICs (no media converters). Two (2) external cable glands Copper Ethernet Three (3) 10/100/1000BaseTX external RJ45 I/O ports Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO.
One (1) DIO/GPIO external I/O port Power Voltage: 90-264VAC
Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight Fusing: 2 internal fuses (5A); delta/wye power
Speaker Minimum 90dB Minimum volume control shall not be less than10dB
24” OIP Connector Kit General Connector kit shall consist of mating connectors and/or cables for all OIP external I/O.
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
Fiber Ethernet Shall have two (2) stuffing tubes provided for fiber connections. Field fiber cables shall penetrate the OIP and land to an included internal ST-ST patch panel which provides the mating junction to the fiber ports on the CPU. Fiber jumpers from CPU fiber ports to ST- ST patch panel shall come pre-installed – two Single-mode & two Multimode to account for all flavors of fiber Ethernet.
Copper Ethernet Mil Spec Connector Support for a minimum of three (3) 10/100/1000BaseTX native copper network interfaces
3 pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors
Isolated GPIO/DIO Support for a minimum of four (4) DI and four (4) DO Cap: mating metal cap for all OIP box mounted connectors
1pc D38999/26WC35SN, DIO/GPIO Mating Connector
USB 3pc USB3FTV5G Circular Mil-USB 3.0 Mating Connector Clamps 2pc M85049/38-13W
24” Flat Panel Display (for single & dual monitor consoles) General Touch screen shall function properly with a Flash Fire Glove.
General Shall be integrated into single and dual monitor consoles.
General Not separately tested. To be tested as part of full assemblies.
Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529) when mounted.
Cooling Shall have passive cooling (no moving parts).
Display Type LCD Backlight LED Touchscreen Single touch resistive 5 wire
Resolution 1920X1080 Aspect Ratio 16:9 Brightness 0-300 nits Brightness Control 0-100% Colors 16 Million Contrast Ratio 5000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical I/O Ports Standard A-B USB 2.0 for touch interface Video Inputs (1) VGA, (1) HDMI, or (1) Display Port Power 85-264VAC
42” Flat Panel Display (FPD) and Mounting Bracket General Touch screen shall function properly with a Flash Fire Glove.
General Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC)
CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed
CPU.
General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shall have Passive cooling (no moving parts).
Display Type Non Plasma Backlight LED Touchscreen IR multi-touch Resolution Native 1920X1080
Aspect Ration 16:9 Brightness 0-500 nits
Brightness Control 0-100% Colors 16 Million Contrast Ratio 4000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical External I/O Ports Standard A USB 2.0 for touch interface External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
External Video Inputs
(1) HDMI (shall be able to transfer Audio through same cable)
Power 85-264VAC (Power On/Off Switch) Integrated Speaker w/ Volume Control
110db at 2 feet orthogonal to display (Sound will pass through HDMI)
Weight NTE 105lbs (with mounting brackets) Power Consumption NTE 105W Dimensions NTE 45.0 (W) x 29.0 (H) x 7.0 (D) (With Vertical Mounting Bracket)
NTE 45.0 (W) x 29.0 (H) x 15.0 (D) (With 15 ° angled bracket).
Mounting Bracket Tilt Angle: 15 ° Up/Down
Material: .187” Aluminum Plate, 42” Flat Panel Display Connector (FPD) Kit General Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.
HDMI Cable 1pc HD-WTP-WMWM-5M, Mating Cable Assembly USB Cable 1pc USB A-A Black 5 Meters USB 2pc USBFTV6G, Mating Connector
46” Flat Panel Display (FPD) and Mounting Bracket General Touch screen shall work with a Flash Fire Glove.
General Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC)
CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU.
General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shall have Passive cooling (no moving parts).
Display Type Non Plasma Backlight LED Touchscreen IR multi-touch Resolution native 1920X1080 Brightness 0-500 nits Brightness Control 0-100% Colors 16 Million Contrast Ratio 4000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal &Vertical External I/O Ports Standard A USB 2.0 for touch interface External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
External Video Inputs
(1) HDMI (shall be able to transfer Audio through same cable)
Power 85-264VAC (Power On/Off Switch) Integrated Speaker w/ Volume Control
90db at 2 feet orthogonal to display (Sound will pass through HDMI)
Weight NTE 122lbs (With Mounting Bracket) Power Consumption NTE 105 W Dimensions 50.0 (W) x 30.0 (H) x 8.0 (D) (With Vertical Mounting Bracket)
50.0 (W) x 30.0 (H) x 17.0 (D) (With 15 ° angled bracket)
Mounting Bracket Tilt Angle: 15 ° Up/Down Material: .187” Aluminum Plate, 46” Flat Panel Display (FPD) Connector Kit General Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.
HDMI Cable 1pc HD-WTP-WMWM-5M, Mating Cable Assembly USB Cable 1pc USB A-A Black 5 Meters USB 2pc USBFTV6G, Mating Connector
Sealed CPU (Latest Generation) Enclosure Dust and water resistance shall be IP54.
Cooling Shall be fan-less, passively cooled, completely solid state without a display, and no moving parts.
General Shall be fan-less, passively cooled, completely solid state without a display.
Supportability Hardware shall be in line with Intel’s long term embedded computing roadmap.
Weight NTE 9lbs Max Power Draw 90W Dimensions 11.0”(W) x 4.0”(H) x 7.0”(D) USB USB: minimum of four (4) USB 3.0 and two (2) USB 2.0 ports Fiber Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or
1000BaseSX native fiber NICs (no media converters) Copper Ethernet Copper Ethernet: Support for a minimum of three (3) 10/100/1000BaseTX Isolated DIO Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO Power Input Power: 12V-36 VDC Power Connector 2-pin Terminal Block: V+, V- Off Switch Push Button CPU Minimum processor performance requirements shall be Intel® Core Processor i7 3.4 GHz or Greater TPM TPM 2.0 or Greater Memory 16GB RAM (single DIMM low power) expandable to 32GB RAM (single DIMM low power) Video Integrated AGP Controller Video Output Video Output: Minimum (1) VGA and (1) HDMI or (1) Display port Sound Integrated Audio BIOS Must allow administrator lockout of USB ports
Must allow administrator password access.
CFast Cfast: 64 GB Wide-Temp Cfast card, User-Accessible Storage Two (2) Solid State Drives with power fail write protection in RAID 1
SSD Drive Capacity (each):
256GB EA SSD Type: Intel Wide-Temp SSD or equivalent
OS Computers shall be compatible with all of the following: Windows 7 Embedded, Windows 10 IOT, Windows 11, RHL 7.x and newer
Power Adapter for Sealed CPU
General Power Adapter shall be a standard power adapter to allow for lab testing. Shall be 120VAC Input, 24VDC Output with standard 120VAC plug on input end and matingplug-in power terminal block on output end.
Sit Down Dual Monitor (SDDM) Console General Touch screen shall function properly with flash fire glove.
Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shall be passive no moving Parts (fanless).
Keyboard Shall have full function USB (114 keys).
Trackball Shall have built-in rugged trackball NEMA compliant.
Monitors Two (2) integrated Flat Panel Displays
Lower Monitor Viewing Angle
Lower monitor shall mount at a 105-degree viewing angle.
Upper Monitor Viewing Angle
Upper monitor shall mount at a 65-degree viewing angle.
Stand Up Dual Monitor (SUDM) Console
General Touch screen shall function properly with flash fire glove.
Console Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shall be passive no moving Parts (fanless).
Keyboard Shall have full function USB (114 keys).
Trackball Shall have built-in rugged trackball NEMA compliant.
Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts.
Color FED-STD-595B, No. 26307 light equipment gray.
Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase. (Power On/Off Switch).
Line Frequency Nominal 60Hz Power Consumption NTE 150 W
Integrated Speaker 110 db output with volume control Max Width 26” Max Height 69.0” (Not including foundation) Max Depth 32.0” Max Weight 340 lbs Foundation Hard mounted. Shall mount to existing foundation bolt hole pattern.
SDDM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SDDM external I/O.
Ethernet 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
Clamp 1pc M85049/38-13W Cable Clamp.
Monitors Two (2) integrated 24” Flat Panel Displays.
Lower Monitor Viewing Angle
Lower monitor shall mount at a 75-degree viewing angle
Upper Monitor Viewing Angle
Upper monitor shall mount at a 90-degree viewing angle
Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts
Color FED-STD-595B, No. 26307 light equipment gray.
Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage Voltage: 85-264VAC (power on/off switch) Input Power 90 to 132 VAC Single Phase Line Frequency Nominal 60Hz Power Consumption NTE 150 W Integrated Speaker 110 db output with volume control Max Width 26” Max Height 80.0. (Not including foundation) Max Depth 32.0 Max Weight 395 lbs Foundation Hard mounted. Shall mount to existing foundation bolt hole pattern.
Sit Down Single Monitor (SDSM) Console
Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shall be passive no moving Parts (fanless).
Keyboard Shall have full function USB (114 keys).
Trackball Shall have built-in rugged trackball NEMA compliant.
Monitor One (1) integrated 24” Flat Panel Display Monitor Viewing Angle
Monitor shall mount at a 105-degree viewing angle
Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
SUDM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SUDM external I/O.
Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts.
Color FED-STD-595B, No. 26307 light equipment gray.
Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase (power on/off switch) Line Frequency Nominal 60Hz Power Consumption NTE 120 W Max Width 26” Max Height 54.0” (Not including foundation) Max Depth 32.0” Max Weight 320 lbs
SUSM Console
Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling Shave be passive no moving Parts (fanless).
Keyboard Shall have full function USB (114 keys).
Trackball Shall have built-in rugged trackball NEMA compliant.
Monitor One (1) integrated 24” Flat Panel Display console Monitor Viewing Angle
Monitor shall mount at a 75-degree viewing angle
Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts
Color FED-STD-595B, No. 26307 light equipment gray.
Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the
SDSM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SDSM external I/O.
bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase (power on/off switch)
Line Frequency Nominal 60Hz Power Consumption NTE 120 W Max Width 26” Max Height 63” (Not including foundation) Max Depth 32.0” Max Weight 375 lbs
Operator Interface Computer (OIC) CPU Enclosure Configuration 1 and Mounting Bracket
General The enclosure shall be fanless, passively cooled, and without a display.
General The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.
General Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.
General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Physical Security Shall be lockable with a hasp Power Voltage: 90-264VAC
Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight CPU ON/OFF Switch Fusing: 2 internal fuses (5A); delta/wye power
Foundation Shall be hard mounted.
External Connection Ports
1 x MIL-STD Power Connector 2 x Circular MIL-STD RJ45 Ethernet Connectors 2 x Fiber Cable Glands 1 x Circular MIL-STD USB 3.0 Connector 1 x Circular MIL-STD HDMI Output
External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
Input Power 90 to 132 VAC Single Phase
SUSM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SUSM external I/O.
Line Frequency Nominal 60Hz Power Consumption 70W Weight NTE 35 lbs Dimensions 15” (W) x 17” (H) x 11” (D) (With Mounting Bracket)
Operator Interface Computer (OIC) CPU Enclosure Configuration 2 General The enclosure shall be fanless, passively cooled, and without a display.
General The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.
General Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.
Enclosure Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Physical Security Shall be lockable with a hasp Speaker 93 dB Speaker Power Voltage: 90-264VAC
Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight CPU ON/OFF Switch for Soft Shutdown with RED indicator Fusing: 2 internal fuses (5A); delta/wye power
Foundation Shall be hard mounted.
External Connection Ports
1 x MIL-STD Power…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .