N6449824R4004.pdf

PDF 1 MB Posted

Attached to
Human Machine Interface (HMI) Equipment Federal contract opportunity
Solicitation number
N6449824R4004
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document is a Solicitation for a federal contract opportunity issued by the Naval Surface Warfare Center Philadelphia Division (NSWCPD) for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machine Interfaces (HMI) equipment.

The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, and associated hardware and peripheral equipment to be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships. The contract has a 5 year ordering period with a minimum order value of $100,000. The solicitation is set aside for small businesses and the incumbent contractor is NAG Marine (Cage Code: 1PL37). Offers are due by 5:00 PM on April 22, 2024. Pricing is Firm Fixed Price. The document provides detailed technical specifications and requirements for the equipment.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEE ADDENDUM

(No Collect Calls)

N6449824R4004 22-Mar-2024

b. TELEPHONE NUMBER 8. OFFER DUE DATE/LOCAL TIME

05:00 PM 22 Apr 2024

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

N644989. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

PATRICK J MCCARRY

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESSX

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

NAVAL SURFACE WARFARE CENTER PHILA

CODE 0222, PATRICK MCCARRY

PATRICK.J.MCCARRY.CIV@US.NAVY.MIL

5001 SOUTH BROAD STREET

PHILADELPHIA PA 19112

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE 16. ADMINISTERED BY

SEE SCHEDULE

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

FAX:

TEL: SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESS

SIZE STANDARD:

1,250

NAICS:

334111

X

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

PAGE 2 OF271

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

Section SF 1449 - CONTINUATION SHEET

GENERAL INFORMATION

General Information

Contract Type: Firm Fixed Price (FFP) IDIQ Period of Performance: 5 Year Ordering Period In accordance with clause 52.216-22 (b), the contract “minimum” order is $100,000

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 50 24" Operator Interface Panel (OIP) w/ It

FFP

Base: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket FOB: Destination

NET AMT

0002 100 Connector Kit for Item 0001

FFP

Base: Connector Kit for Item 0001 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.

0003 110 24" Flat Panel Display (FPD)

FFP

Base : 24" Flat Panel Display (FPD) (for single & dual monitor consoles)

0004 25 42" Flat Panel Display (FPD) w/bracket

FFP

Base: 42" Flat Panel Display (FPD) w/bracket

0005 50 Connector Kit for Item 0004

FFP

Base:Connector Kit for Item 0004 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0006 25 46" Flat Panel Display (FPD) w/bracket

FFP

Base: 46" Flat Panel Display (FPD) w/bracket

0007 50 Connector Kit for Item 0006

FFP

Base: Connector Kit for Item 0006

0008 225 Sealed CPU

FFP

Base: Sealed CPU

0009 225 Power Adapter for Item 0008

FFP

Base: Power Adapter for Item 0008 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0010 10 Sit Down Dual Monitor Console (SDDM)

FFP

Base: Sit Down Dual Monitor Console (SDDM)

0011 20 Connector Kit for Item 0010

FFP

Base: Connector Kit for Item 0010 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0012 10 Stand Up Dual Monitor Console (SUDM)

FFP

Base: Stand Up Dual Monitor Console (SUDM)

0013 20 Connector Kit for Item 0012

FFP

Base: Connector Kit for Item 0012 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0014 35 Sit Down Single Monitor Console (SDSM)

FFP

Base: Sit Down Single Monitor Console (SDSM)

0015 70 Connector Kit for Item 0014

FFP

Base: Connector Kit for Item 0014 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0016 10 Stand Up Single Monitor Console (SUSM)

FFP

Base: Stand Up Single Monitor Console (SUSM)

0017 20 Connector Kit for Item 0016

FFP

Base: Connector Kit for Item 0016 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0018 50 Operator Interface Computer (OIC)

FFP

Base: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket

0019 100 Connector Kit for Item 0018

FFP

Base: Connector Kit for Item 0018 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0020 50 Operator Interface Computer (OIC)

FFP

Base:Operator Interface Computer (OIC) CPU Enclosure 2

0021 50 Mounting Bracket for Item 0020

FFP

Base: Mounting bracket for Item 0020 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0022 100 Connector Kit for Item 0020

FFP

Base: Connector Kit for Item 0020 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0023 50 Rugged Keyboard/trackball/mounting brack

FFP

Base: Rugged Keyboard/trackball/mounting bracket

0024 5 Rack Mounted Uninterruptable Power Suppl

FFP

Base: Rack Mounted Uninterruptable Power Supply (UPS)

0025 20 Tower-Style Uninterruptable Power Supply

FFP

Base: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA

0026 20 UPS Foundation

FFP

Base: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0027 50 UPS Connector Kit - Input

FFP

Base: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0028 100 UPS Connector Kit - Output

FFP

Base: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0029 20 Mod kit for console RGB video connection

FFP

Base: Mod kit for console RGB video connection

0030 20 Mod kit for console ABT (Automatic Bus T

FFP

Base: Mod kit for console ABT (Automatic Bus Transfer) switch

0031 50 24" Operator Interface Panel (OIP) w/ It

FFP

Year 2: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket

0032 100 Connector Kit for Item 0031

FFP

Year 2: Connector Kit for Item 0031 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0033 110 24" Flat Panel Display (FPD)

FFP

Year 2:24" Flat Panel Display (FPD) (for single & dual monitor consoles)

0034 25 42" Flat Panel Display (FPD) w/bracket

FFP

Year 2: 42" Flat Panel Display (FPD) w/bracket

0035 50 Connector Kit for Item 0034

FFP

Year 2:Connector Kit for Item 0034 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0036 25 46" Flat Panel Display (FPD) w/bracket

FFP

Year 2: 46" Flat Panel Display (FPD) w/bracket

0037 50 Connector Kit for Item 0036

FFP

Year 2: Connector Kit for Item 0036 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0038 225 Sealed CPU

FFP

Year 2: Sealed CPU

0039 225 Power Adapter for Item 0038

FFP

Year 2: Power Adapter for Item 0038 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0040 10 Sit Down Dual Monitor Console (SDDM)

FFP

Year 2: Sit Down Dual Monitor Console (SDDM)

0041 20 Connector Kit for Item 0040

FFP

Year 2: Connector Kit for Item 0040 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0042 10 Stand Up Dual Monitor Console (SUDM)

FFP

Year 2: Stand Up Dual Monitor Console (SUDM)

0043 20 Connector Kit for Item 0042

FFP

Year 2: Connector Kit for Item 0042 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0044 35 Sit Down Single Monitor Console (SDSM)

FFP

Year 2: Sit Down Single Monitor Console (SDSM)

0045 70 Connector Kit for Item 0044

FFP

Year 2: Connector Kit for Item 0044 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0046 10 Stand Up Single Monitor Console (SUSM)

FFP

Year 2: Stand Up Single Monitor Console (SUSM)

0047 20 Connector Kit for Item 0046

FFP

Year 2: Connector Kit for Item 0046 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0048 50 Operator Interface Computer (OIC)

FFP

Year 2: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket

0049 100 Connector Kit for Item 0048

FFP

Year 2: Connector Kit for Item 0048 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0050 50 Operator Interface Computer (OIC)

FFP

Year 2:Operator Interface Computer (OIC) CPU Enclosure 2

0051 50 Mounting Bracket for Item 0050

FFP

Year 2: Mounting bracket for Item 0050 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0052 100 Connector Kit for Item 0050

FFP

Year 2: Connector Kit for Item 0050 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0053 50 Rugged Keyboard/trackball/mounting brack

FFP

Year 2: Rugged Keyboard/trackball/mounting bracket

0054 5 Rack Mounted Uninterruptable Power Suppl

FFP

Year 2: Rack Mounted Uninterruptable Power Supply (UPS)

0055 20 Tower-Style Uninterruptable Power Supply

FFP

Year 2: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA

0056 20 UPS Foundation

FFP

Year 2: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0057 50 UPS Connector Kit - Input

FFP

Year 2: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0058 100 UPS Connector Kit - Output

FFP

Year 2: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0059 20 Mod kit for console RGB video connection

FFP

Year 2: Mod kit for console RGB video connection

0060 20 Mod kit for console ABT (Automatic Bus T

FFP

Year 2: Mod kit for console ABT (Automatic Bus Transfer) switch

0061 50 24" Operator Interface Panel (OIP) w/ It

FFP

Year 3: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket

0062 100 Connector Kit for Item 0061

FFP

Year 3: Connector Kit for Item 0061 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0063 110 24" Flat Panel Display (FPD)

FFP

Year 3: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)

0064 25 42" Flat Panel Display (FPD) w/bracket

FFP

Year 3: 42" Flat Panel Display (FPD) w/bracket

0065 50 Connector Kit for Item 0064

FFP

Year 3:Connector Kit for Item 0064 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0066 25 46" Flat Panel Display (FPD) w/bracket

FFP

Year 3: 46" Flat Panel Display (FPD) w/bracket

0067 50 Connector Kit for Item 0066

FFP

Year 3: Connector Kit for Item 0066 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0068 225 Sealed CPU

FFP

Year 3: Sealed CPU

0069 225 Power Adapter for Item 0068

FFP

Year 3: Power Adapter for Item 0068 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0070 10 Sit Down Dual Monitor Console (SDDM)

FFP

Year 3: Sit Down Dual Monitor Console (SDDM)

0071 20 Connector Kit for Item 0070

FFP

Year 3: Connector Kit for Item 0070 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0072 10 Stand Up Dual Monitor Console (SUDM)

FFP

Year 3: Stand Up Dual Monitor Console (SUDM)

0073 20 Connector Kit for Item 0072

FFP

Year 3: Connector Kit for Item 0072 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0074 35 Sit Down Single Monitor Console (SDSM)

FFP

Year 3: Sit Down Single Monitor Console (SDSM)

0075 70 Connector Kit for Item 0074

FFP

Year 3: Connector Kit for Item 0074 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0076 10 Stand Up Single Monitor Console (SUSM)

FFP

Year 3: Stand Up Single Monitor Console (SUSM)

0077 20 Connector Kit for Item 0076

FFP

Year 3: Connector Kit for Item 0076 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0078 50 Operator Interface Computer (OIC)

FFP

Year 3: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket

0079 100 Connector Kit for Item 0078

FFP

Year 3: Connector Kit for Item 0078 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0080 50 Operator Interface Computer (OIC)

FFP

Year 3:Operator Interface Computer (OIC) CPU Enclosure 2

0081 50 Mounting Bracket for Item 0080

FFP

Year 3: Mounting bracket for Item 0080 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0082 100 Connector Kit for Item 0080

FFP

Year 3: Connector Kit for Item 0080 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0083 50 Rugged Keyboard/trackball/mounting brack

FFP

Year 3: Rugged Keyboard/trackball/mounting bracket

0084 5 Rack Mounted Uninterruptable Power Suppl

FFP

Year 3: Rack Mounted Uninterruptable Power Supply (UPS)

0085 20 Tower-Style Uninterruptable Power Supply

FFP

Year 3: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA

0086 20 UPS Foundation

FFP

Year 3: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0087 50 UPS Connector Kit - Input

FFP

Year 3: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0088 100 UPS Connector Kit - Output

FFP

Year 3: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0089 20 Mod kit for console RGB video connection

FFP

Year 3: Mod kit for console RGB video connection

0090 20 Mod kit for console ABT (Automatic Bus T

FFP

Year 3: Mod kit for console ABT (Automatic Bus Transfer) switch

0091 50 24" Operator Interface Panel (OIP) w/ It

FFP

Year 4: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket

0092 100 Connector Kit for Item 0091

FFP

Year 4: Connector Kit for Item 0091 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0093 110 24" Flat Panel Display (FPD)

FFP

Year 4: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)

0094 25 42" Flat Panel Display (FPD) w/bracket

FFP

Year 4: 42" Flat Panel Display (FPD) w/bracket

0095 50 Connector Kit for Item 0094

FFP

Year 4:Connector Kit for Item 0094 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0096 25 46" Flat Panel Display (FPD) w/bracket

FFP

Year 4: 46" Flat Panel Display (FPD) w/bracket

0097 50 Connector Kit for Item 0096

FFP

Year 4: Connector Kit for Item 0096 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0098 225 Sealed CPU

FFP

Year 4: Sealed CPU

0099 225 Power Adapter for Item 0098

FFP

Year 4: Power Adapter for Item 0098 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0100 10 Sit Down Dual Monitor Console (SDDM)

FFP

Year 4: Sit Down Dual Monitor Console (SDDM)

0101 20 Connector Kit for Item 0100

FFP

Year 4: Connector Kit for Item 0100 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0102 10 Stand Up Dual Monitor Console (SUDM)

FFP

Year 4: Stand Up Dual Monitor Console (SUDM)

0103 20 Connector Kit for Item 0102

FFP

Year 4: Connector Kit for Item 0102 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0104 35 Sit Down Single Monitor Console (SDSM)

FFP

Year 4: Sit Down Single Monitor Console (SDSM)

0105 70 Connector Kit for Item 0104

FFP

Year 4: Connector Kit for Item 0104 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0106 10 Stand Up Single Monitor Console (SUSM)

FFP

Year 4: Stand Up Single Monitor Console (SUSM)

0107 20 Connector Kit for Item 0106

FFP

Year 4: Connector Kit for Item 0106 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0108 50 Operator Interface Computer (OIC)

FFP

Year 4: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket

0109 100 Connector Kit for Item 0108

FFP

Year 4: Connector Kit for Item 0108 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0110 50 Operator Interface Computer (OIC)

FFP

Year 4:Operator Interface Computer (OIC) CPU Enclosure 2

0111 50 Mounting Bracket for Item 0110

FFP

Year 4: Mounting bracket for Item 0110 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0112 100 Connector Kit for Item 0110

FFP

Year 4: Connector Kit for Item 0110 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0113 50 Rugged Keyboard/trackball/mounting brack

FFP

Year 4: Rugged Keyboard/trackball/mounting bracket

0114 5 Rack Mounted Uninterruptable Power Suppl

FFP

Year 4: Rack Mounted Uninterruptable Power Supply (UPS)

0115 20 Tower-Style Uninterruptable Power Supply

FFP

Year 4: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA

0116 20 UPS Foundation

FFP

Year 4: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0117 50 UPS Connector Kit - Input

FFP

Year 4: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0118 100 UPS Connector Kit - Output

FFP

Year 4: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0119 20 Mod kit for console RGB video connection

FFP

Year 4: Mod kit for console RGB video connection

0120 20 Mod kit for console ABT (Automatic Bus T

FFP

Year 4: Mod kit for console ABT (Automatic Bus Transfer) switch

0121 50 24" Operator Interface Panel (OIP) w/ It

FFP

Year 5: 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket

0122 100 Connector Kit for Item 0121

FFP

Year 5: Connector Kit for Item 0121 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0123 110 24" Flat Panel Display (FPD)

FFP

Year 5: 24" Flat Panel Display (FPD) (for single & dual monitor consoles)

0124 25 42" Flat Panel Display (FPD) w/bracket

FFP

Year 5: 42" Flat Panel Display (FPD) w/bracket

0125 50 Connector Kit for Item 0124

FFP

Year 5:Connector Kit for Item 0124 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0126 25 46" Flat Panel Display (FPD) w/bracket

FFP

Year 5: 46" Flat Panel Display (FPD) w/bracket

0127 50 Connector Kit for Item 0126

FFP

Year 5: Connector Kit for Item 0126 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0128 225 Sealed CPU

FFP

Year 5: Sealed CPU

0129 225 Power Adapter for Item 0128

FFP

Year 5: Power Adapter for Item 0128 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0130 10 Sit Down Dual Monitor Console (SDDM)

FFP

Year 5: Sit Down Dual Monitor Console (SDDM)

0131 20 Connector Kit for Item 0130

FFP

Year 5: Connector Kit for Item 0130 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0132 10 Stand Up Dual Monitor Console (SUDM)

FFP

Year 5: Stand Up Dual Monitor Console (SUDM)

0133 20 Connector Kit for Item 0132

FFP

Year 5: Connector Kit for Item 0132 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0134 35 Sit Down Single Monitor Console (SDSM)

FFP

Year 5: Sit Down Single Monitor Console (SDSM)

0135 70 Connector Kit for Item 0134

FFP

Year 5: Connector Kit for Item 0134 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0136 10 Stand Up Single Monitor Console (SUSM)

FFP

Year 5: Stand Up Single Monitor Console (SUSM)

0137 20 Connector Kit for Item 0136

FFP

Year 5: Connector Kit for Item 0136 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0138 50 Operator Interface Computer (OIC)

FFP

Year 5: Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket

0139 100 Connector Kit for Item 0138

FFP

Year 5: Connector Kit for Item 0138 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0140 50 Operator Interface Computer (OIC)

FFP

Year 5:Operator Interface Computer (OIC) CPU Enclosure 2

0141 50 Mounting Bracket for Item 0140

FFP

Year 5: Mounting bracket for Item 0140 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0142 100 Connector Kit for Item 0140

FFP

Year 5: Connector Kit for Item 0140 NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0143 50 Rugged Keyboard/trackball/mounting brack

FFP

Year 5: Rugged Keyboard/trackball/mounting bracket

0144 5 Rack Mounted Uninterruptable Power Suppl

FFP

Year 5: Rack Mounted Uninterruptable Power Supply (UPS)

0145 20 Tower-Style Uninterruptable Power Supply

FFP

Year 5: Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA

0146 20 UPS Foundation

FFP

Year 5: UPS Foundation NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0147 50 UPS Connector Kit - Input

FFP

Year 5: UPS Connector Kit - Input NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0148 100 UPS Connector Kit - Output

FFP

Year 5: UPS Connector Kit - Output NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD

0149 20 Mod kit for console RGB video connection

FFP

Year 5: Mod kit for console RGB video connection

0150 20 Mod kit for console ABT (Automatic Bus T

FFP

Year 5: Mod kit for console ABT (Automatic Bus Transfer) switch

0151 1 Lot Technical Data

FFP

FFP

Refer to Contract Data Requiremetns List (CDRL) DD Form 1423 and Contract Specifications. Not Separately Priced (NSP)

SECTION C

Technical Specifications for Human Machine Interface (HMI) Equipment

1.0 INTRODUCTION

1.0.1 The Naval Surface Warfare Center Philadelphia Division (NSWCPD) is a Department of Defense entity responsible for research and development, test and evaluation, engineering and fleet support organization for the Navy’s ships, submarines, military watercraft and unmanned vehicles. This requirement is for NSWCPD Code 516, which is responsible for machinery controls engineering support and advanced damage control systems support.

1.1 BACKGROUND

The requirement is in support of a contract for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machined Interfaces (HMI). These HMIs shall be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships to control and monitor multiple systems. The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, associated hardware and peripheral equipment used to display and control system specific information.

1.2 SCOPE OF WORK

Please see section 3.0 for a full listing of required equipment

2.0 APPLICABLE DOCUMENTS

Not applicable

3.0 REQUIREMENTS

3.1 Contractor shall provide items in Schedule B upon issuance of task orders

3.2 Environmental Qualification Testing (EQT)

All equipment shall meet or exceed the following EQT standards:

Equipment Environmental Requirements Shock MIL-S-901D Grade A, Class 1, Type A – Deck and

Hull Mounting Vibration MIL-STD-167-1A, Type 1 EMI MIL-STD-461G (surface ship, below deck) EMI (Rugged Keyboard) MIL-STD-461F (surface ship, below deck) High Operating Temperature MIL-STD-810G Method 501.6, Procedure II

(Test to maximum days suggested in MIL-STD for max temperature and max load)

High Storage Temperature MIL-STD-810G Method 501.6, Procedure I Low Operating Temperature MIL-STD-810G Method 502.6, Procedure II Low Storage Temperature MIL-STD-810G Method 502.6, Procedure I Humidity MIL-STD-810G, Method 507.6 (0-95% non-condensing) Power MIL-STD-1399 SECTION 300B Grounding and Bonding MIL-STD-1310G Human Factors MIL-STD-1472G

3.3 Equipment Technical Specifications

All equipment shall meet or exceed the following technical specifications:

24” Operator Interface Panel (OIP) w/ Sealed CPU and Mounting Bracket General Touchscreen shall function properly with a Flash Fire Glove.

General

Shall include Section 3.1 item 8 removable Sealed CPU.

General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.

Enclosure Dust and water resistance shall be IP65 (Reference IEC 60529).

Door Shall consist of a complete integral unit with a hinged bezel for maintenance efforts.

Door Bezel shall be able to be physically secured using a hasp with lock.

Cooling Shall have passive cooling (no moving parts).

Physical Security Shall be lockable.

Display Type Liquid Crystal Display (LCD) Backlight Light Emitting Diode (LED) backlight Pointer Shall contain a bezel mounted pointer with right & left click.

Touch Screen single touch resistive 5+ wire

Resolution 1920x1080 Aspect Ratio 16:9 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical Brightness 0-300 nits

Brightness Control 0-100% (Dimmable to full dark).

Colors 16 Million

Contrast Ratio 5000:1

Material 0.125” Aluminum 5052-H32 Alloy. Chemically treated IAW MIL-DTL 5541, Type II, Class 1A. Material shall not contain hexavalent chromium.

Weight Not to Exceed (NTE) 60lbs with mount bracket.

Max Power Consumption

NTE 100W

Dimensions NTE 26.0” (W) x 18” (H) x 12.0” (D) (with mounting) Mounting Bracket Tilt Angle: 15 ° Up/Down: Material: .187” Aluminum Plate USB Two (2) USB 3.0 external I/O ports External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.

Fiber Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or

1000BaseSX native fiber NICs (no media converters). Two (2) external cable glands Copper Ethernet Three (3) 10/100/1000BaseTX external RJ45 I/O ports Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO.

One (1) DIO/GPIO external I/O port Power Voltage: 90-264VAC

Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight Fusing: 2 internal fuses (5A); delta/wye power

Speaker Minimum 90dB Minimum volume control shall not be less than10dB

24” OIP Connector Kit General Connector kit shall consist of mating connectors and/or cables for all OIP external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Fiber Ethernet Shall have two (2) stuffing tubes provided for fiber connections. Field fiber cables shall penetrate the OIP and land to an included internal ST-ST patch panel which provides the mating junction to the fiber ports on the CPU. Fiber jumpers from CPU fiber ports to ST- ST patch panel shall come pre-installed – two Single-mode & two Multimode to account for all flavors of fiber Ethernet.

Copper Ethernet Mil Spec Connector Support for a minimum of three (3) 10/100/1000BaseTX native copper network interfaces

3 pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors

Isolated GPIO/DIO Support for a minimum of four (4) DI and four (4) DO Cap: mating metal cap for all OIP box mounted connectors

1pc D38999/26WC35SN, DIO/GPIO Mating Connector

USB 3pc USB3FTV5G Circular Mil-USB 3.0 Mating Connector Clamps 2pc M85049/38-13W

24” Flat Panel Display (for single & dual monitor consoles) General Touch screen shall function properly with a Flash Fire Glove.

General Shall be integrated into single and dual monitor consoles.

General Not separately tested. To be tested as part of full assemblies.

Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529) when mounted.

Cooling Shall have passive cooling (no moving parts).

Display Type LCD Backlight LED Touchscreen Single touch resistive 5 wire

Resolution 1920X1080 Aspect Ratio 16:9 Brightness 0-300 nits Brightness Control 0-100% Colors 16 Million Contrast Ratio 5000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical I/O Ports Standard A-B USB 2.0 for touch interface Video Inputs (1) VGA, (1) HDMI, or (1) Display Port Power 85-264VAC

42” Flat Panel Display (FPD) and Mounting Bracket General Touch screen shall function properly with a Flash Fire Glove.

General Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC)

CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed

CPU.

General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.

Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shall have Passive cooling (no moving parts).

Display Type Non Plasma Backlight LED Touchscreen IR multi-touch Resolution Native 1920X1080

Aspect Ration 16:9 Brightness 0-500 nits

Brightness Control 0-100% Colors 16 Million Contrast Ratio 4000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal & Vertical External I/O Ports Standard A USB 2.0 for touch interface External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.

External Video Inputs

(1) HDMI (shall be able to transfer Audio through same cable)

Power 85-264VAC (Power On/Off Switch) Integrated Speaker w/ Volume Control

110db at 2 feet orthogonal to display (Sound will pass through HDMI)

Weight NTE 105lbs (with mounting brackets) Power Consumption NTE 105W Dimensions NTE 45.0 (W) x 29.0 (H) x 7.0 (D) (With Vertical Mounting Bracket)

NTE 45.0 (W) x 29.0 (H) x 15.0 (D) (With 15 ° angled bracket).

Mounting Bracket Tilt Angle: 15 ° Up/Down

Material: .187” Aluminum Plate, 42” Flat Panel Display Connector (FPD) Kit General Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.

HDMI Cable 1pc HD-WTP-WMWM-5M, Mating Cable Assembly USB Cable 1pc USB A-A Black 5 Meters USB 2pc USBFTV6G, Mating Connector

46” Flat Panel Display (FPD) and Mounting Bracket General Touch screen shall work with a Flash Fire Glove.

General Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC)

CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU.

General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.

Enclosure Dust and water resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shall have Passive cooling (no moving parts).

Display Type Non Plasma Backlight LED Touchscreen IR multi-touch Resolution native 1920X1080 Brightness 0-500 nits Brightness Control 0-100% Colors 16 Million Contrast Ratio 4000:1 Glass 2.8mm Tempered Glass Min Viewing Angle 85° Horizontal &Vertical External I/O Ports Standard A USB 2.0 for touch interface External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.

External Video Inputs

(1) HDMI (shall be able to transfer Audio through same cable)

Power 85-264VAC (Power On/Off Switch) Integrated Speaker w/ Volume Control

90db at 2 feet orthogonal to display (Sound will pass through HDMI)

Weight NTE 122lbs (With Mounting Bracket) Power Consumption NTE 105 W Dimensions 50.0 (W) x 30.0 (H) x 8.0 (D) (With Vertical Mounting Bracket)

50.0 (W) x 30.0 (H) x 17.0 (D) (With 15 ° angled bracket)

Mounting Bracket Tilt Angle: 15 ° Up/Down Material: .187” Aluminum Plate, 46” Flat Panel Display (FPD) Connector Kit General Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.

HDMI Cable 1pc HD-WTP-WMWM-5M, Mating Cable Assembly USB Cable 1pc USB A-A Black 5 Meters USB 2pc USBFTV6G, Mating Connector

Sealed CPU (Latest Generation) Enclosure Dust and water resistance shall be IP54.

Cooling Shall be fan-less, passively cooled, completely solid state without a display, and no moving parts.

General Shall be fan-less, passively cooled, completely solid state without a display.

Supportability Hardware shall be in line with Intel’s long term embedded computing roadmap.

Weight NTE 9lbs Max Power Draw 90W Dimensions 11.0”(W) x 4.0”(H) x 7.0”(D) USB USB: minimum of four (4) USB 3.0 and two (2) USB 2.0 ports Fiber Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or

1000BaseSX native fiber NICs (no media converters) Copper Ethernet Copper Ethernet: Support for a minimum of three (3) 10/100/1000BaseTX Isolated DIO Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO Power Input Power: 12V-36 VDC Power Connector 2-pin Terminal Block: V+, V- Off Switch Push Button CPU Minimum processor performance requirements shall be Intel® Core Processor i7 3.4 GHz or Greater TPM TPM 2.0 or Greater Memory 16GB RAM (single DIMM low power) expandable to 32GB RAM (single DIMM low power) Video Integrated AGP Controller Video Output Video Output: Minimum (1) VGA and (1) HDMI or (1) Display port Sound Integrated Audio BIOS Must allow administrator lockout of USB ports

Must allow administrator password access.

CFast Cfast: 64 GB Wide-Temp Cfast card, User-Accessible Storage Two (2) Solid State Drives with power fail write protection in RAID 1

SSD Drive Capacity (each):

256GB EA SSD Type: Intel Wide-Temp SSD or equivalent

OS Computers shall be compatible with all of the following: Windows 7 Embedded, Windows 10 IOT, Windows 11, RHL 7.x and newer

Power Adapter for Sealed CPU

General Power Adapter shall be a standard power adapter to allow for lab testing. Shall be 120VAC Input, 24VDC Output with standard 120VAC plug on input end and matingplug-in power terminal block on output end.

Sit Down Dual Monitor (SDDM) Console General Touch screen shall function properly with flash fire glove.

Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shall be passive no moving Parts (fanless).

Keyboard Shall have full function USB (114 keys).

Trackball Shall have built-in rugged trackball NEMA compliant.

Monitors Two (2) integrated Flat Panel Displays

Lower Monitor Viewing Angle

Lower monitor shall mount at a 105-degree viewing angle.

Upper Monitor Viewing Angle

Upper monitor shall mount at a 65-degree viewing angle.

Stand Up Dual Monitor (SUDM) Console

General Touch screen shall function properly with flash fire glove.

Console Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shall be passive no moving Parts (fanless).

Keyboard Shall have full function USB (114 keys).

Trackball Shall have built-in rugged trackball NEMA compliant.

Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.

Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts.

Color FED-STD-595B, No. 26307 light equipment gray.

Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.

Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.

I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port

ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print

PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors

Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase. (Power On/Off Switch).

Line Frequency Nominal 60Hz Power Consumption NTE 150 W

Integrated Speaker 110 db output with volume control Max Width 26” Max Height 69.0” (Not including foundation) Max Depth 32.0” Max Weight 340 lbs Foundation Hard mounted. Shall mount to existing foundation bolt hole pattern.

SDDM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SDDM external I/O.

Ethernet 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.

Clamp 1pc M85049/38-13W Cable Clamp.

Monitors Two (2) integrated 24” Flat Panel Displays.

Lower Monitor Viewing Angle

Lower monitor shall mount at a 75-degree viewing angle

Upper Monitor Viewing Angle

Upper monitor shall mount at a 90-degree viewing angle

Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.

Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts

Color FED-STD-595B, No. 26307 light equipment gray.

Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.

Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.

I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port

ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print

PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors

Voltage Voltage: 85-264VAC (power on/off switch) Input Power 90 to 132 VAC Single Phase Line Frequency Nominal 60Hz Power Consumption NTE 150 W Integrated Speaker 110 db output with volume control Max Width 26” Max Height 80.0. (Not including foundation) Max Depth 32.0 Max Weight 395 lbs Foundation Hard mounted. Shall mount to existing foundation bolt hole pattern.

Sit Down Single Monitor (SDSM) Console

Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shall be passive no moving Parts (fanless).

Keyboard Shall have full function USB (114 keys).

Trackball Shall have built-in rugged trackball NEMA compliant.

Monitor One (1) integrated 24” Flat Panel Display Monitor Viewing Angle

Monitor shall mount at a 105-degree viewing angle

Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.

SUDM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SUDM external I/O.

Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts.

Color FED-STD-595B, No. 26307 light equipment gray.

Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.

Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.

I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port

ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print

PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors

Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase (power on/off switch) Line Frequency Nominal 60Hz Power Consumption NTE 120 W Max Width 26” Max Height 54.0” (Not including foundation) Max Depth 32.0” Max Weight 320 lbs

SUSM Console

Console Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).

Cooling Shave be passive no moving Parts (fanless).

Keyboard Shall have full function USB (114 keys).

Trackball Shall have built-in rugged trackball NEMA compliant.

Monitor One (1) integrated 24” Flat Panel Display console Monitor Viewing Angle

Monitor shall mount at a 75-degree viewing angle

Computer Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.

Mounting The console shall employ a “hard mount” configuration without the use of shock isolation mounts

Color FED-STD-595B, No. 26307 light equipment gray.

Access & Security The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.

Cable Penetrations Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the

SDSM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SDSM external I/O.

bottom base and shall not preclude compliance with the referenced environmental requirements.

I/O Panel Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port

ID Nameplate An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print

PDU A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors

Voltage Voltage: 85-264VAC Input Power 90 to 132 VAC Single Phase (power on/off switch)

Line Frequency Nominal 60Hz Power Consumption NTE 120 W Max Width 26” Max Height 63” (Not including foundation) Max Depth 32.0” Max Weight 375 lbs

Operator Interface Computer (OIC) CPU Enclosure Configuration 1 and Mounting Bracket

General The enclosure shall be fanless, passively cooled, and without a display.

General The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.

General Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.

General Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.

Enclosure Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).

Physical Security Shall be lockable with a hasp Power Voltage: 90-264VAC

Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight CPU ON/OFF Switch Fusing: 2 internal fuses (5A); delta/wye power

Foundation Shall be hard mounted.

External Connection Ports

1 x MIL-STD Power Connector 2 x Circular MIL-STD RJ45 Ethernet Connectors 2 x Fiber Cable Glands 1 x Circular MIL-STD USB 3.0 Connector 1 x Circular MIL-STD HDMI Output

External I/O Ports All external connections shall have a positive locking mechanism with mating metal dust cap and tether.

Input Power 90 to 132 VAC Single Phase

SUSM Connector Kit General Connector kit shall consist of mating connectors and/or cables for all SUSM external I/O.

Line Frequency Nominal 60Hz Power Consumption 70W Weight NTE 35 lbs Dimensions 15” (W) x 17” (H) x 11” (D) (With Mounting Bracket)

Operator Interface Computer (OIC) CPU Enclosure Configuration 2 General The enclosure shall be fanless, passively cooled, and without a display.

General The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.

General Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.

Enclosure Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).

Physical Security Shall be lockable with a hasp Speaker 93 dB Speaker Power Voltage: 90-264VAC

Rating: 2x max power consumption Connector: MS27656T15B5P Current 2.7A max @ 115VAC On/Off Switch: Toggle Switch STDP, 15A, Water Tight CPU ON/OFF Switch for Soft Shutdown with RED indicator Fusing: 2 internal fuses (5A); delta/wye power

Foundation Shall be hard mounted.

External Connection Ports

1 x MIL-STD Power…

This is the start of the file's text. The full file is on GovTribe.