SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION B - SUPPLIES OR SERVICES AND PRICES

CLIN 0003

The pricing detail quantity has decreased by 6.00 from 6.00 to 0.00.

SECTION C - DESCRIPTIONS AND SPECIFICATIONS

The following have been modified:

GENERAL

This is a Request for Quotation (RFQ) for a commercial item(s) prepared in accordance with the information in FAR Part 13

SALES TAX EXEMPTION

The contractor is hereby advised that the United States Government and Agencies thereof are exempt from State and Local Government tax by virtue of Article 6 of the United States Constitution. No exemption certificate is required.

1. INTRODUCTION

The Naval Surface Warfare Center, Corona Division (NSWC Corona), Performance Assessment Department, Code PA32 requires Falcon UPS and Galvanic Isolation Units for electrical backup power and conditioning of 1.5 meter satellite antennas for Shipboard Data Collection and Distribution System (SDCDS) in order to meet mission support requirements.

2. BACKGROUND

NSWC Corona, Code PA32 is responsible for providing telecommunications over satellite to NSWC Corona during Navy test events. As part of this requirement classified Aegis Weapon System (AWS) data is processed onboard ships and transmitted to Corona for near-real-time data analysis. The analysis is a requirement set forth by the Program Office in order to determine a ship’s readiness for deployment. In order to meet this requirement, PA32 requires the hardware listed in this SOW.

The Falcon Brand On-Line UPS and Galvanic Isolation Module are customized to work together for ocean-going ships. They provide protection from poor power standards, voltage brown-outs, voltage surges, noise and harmonics in addition to voltage transients also providing continuous power conditioning from the falcon on-line UPS. The Galvanic Isolation steps down the incoming 240 AC power to a regulated 120 AC power. This removes any remaining transients, frequency, and harmonic problems while allowing the UPS to operate over the widest range of input voltage.

3. SCOPE/SPECIFICATIONS

The below items must meet shipboard power conditioning and backup power requirements for existing satellite antennas.

CLIN
P/N
DESCRIPTION
BRAND
Qty.
1
XM3KRM-2/1-NSWC
Galvanic Isolation Module in 2U Rack
Falcon
5
2
SSG3KRM-1-NSWC
High Temperature On-Line UPS inverter only w/o standard battery module
Falcon
5
3
SSG2.2KRM-1-NSWC-IVN
High Temperature On-Line UPS inverter only w/o standard battery module
Falcon
1
4
SSG-BCBL-6FT
6’ Battery interconnect cable
Falcon
1
5
SSG2.2KRM-1-NSWC
High Temperature On-Line UPS w/SSGR separate battery module
Falcon
6
6
SGIT2KRM-1TU-NSWC
Galvanic Isolation Module in 2U Rack
Falcon
7
7
SSG1.5KRM-1-NSWC
On-Line UPS w/ECN #020606-NSWC shipboard modification
Falcon
7
8
SSG-RBP
SSG standard 48Vdc battery replacement pack
Falcon
18

4. REQUIREMENTS

All equipment is listed with the manufacturer. It is required to meet the specification of the equipment listed above. The specifications are detailed below:

Line Item #
Brand
P/N
Description
1
Falcon
XM3KRM-2/1-NSWC
Galvanic Isolation Module in 2U Rack

Specifications:

Rated 3000VA, 3000Watts

Input: 240Vac

Output: 120Vac

Input: 6' line cord w/L6-30P

Output: (1) L5-30R

Dimension: 3.5" x 16.8" x 20.5" (H x W x D), Wt = 74 lbs

2
Falcon
SSG3KRM-1-NSWC
High Temperature On-Line UPS inverter only w/o standard battery module

Specifications:

Rated 3000VA, 2100 Watts

Input: 120Vac (80 - 138Vac), 50/60Hz

Output: 120Vac +/-2% (100, 110, 115 or 120Vac user programmable), 50/60Hz Input 6' line cord L5-30P

Output receptacles: (4) 5-15R & (1) L5-30R

3
Falcon
SSG2.2KRM-1-NSWC-IVN
High Temperature On-Line UPS inverter only w/o standard battery module

Specifications:

Rated 2200VA, 1540 Watts

Input: 120Vac (80 - 138Vac), 50/60Hz

Output: 120Vac +/-2% (100, 110, 115 or 120Vac user programmable), 50/60Hz

Input 6' line cord L5-20P

Output receptacles: (4) 5-15R & (1) L5-30R

5
Falcon
SSG2.2KRM-1-NSWC
High Temperature On-Line UPS w/SSGR separate battery module

Specifications:

Rated 2200VA, 1540 Watts

Input: 120Vac (80 - 138Vac), 50/60Hz

Output: 120Vac +/-2% (100, 110, 115 or 120Vac user programmable), 50/60Hz

Input 6' line cord L5-20P

Output receptacles: (4) 5-15R & (1) L5-30R

6
Falcon
SGIT2KRM-1TU-NSWC
Galvanic Isolation Module in 2U Rack

Specification:

Rated 2000VA, 2000Watts

Input: 120Vac

Output: 120Vac

Input: 6' line cord w/L5-20P

Output: (1) L5-20R

7
Falcon
SSG1.5KRM-1-NSWC
On-Line UPS w/ECN #020606-NSWC shipboard modification

Specifications:

Rated 1500VA, 1050 Watts

Input 120Vac (80 - 138Vac), 50/60Hz

Output: 120Vac +2% (100, 110, 115 or 120Vac user programmable), 50/60Hz

Input 6' line cord L5-20P

Output receptacles: (8) 5-15R

UPS Dimension: 3.5” x 19” x 21.3” (H x W x D), Wt = 55 lbs

SECTION F - DELIVERIES OR PERFORMANCE

The following Delivery Schedule item for CLIN 0003 has been changed from:

DELIVERY DATE
QUANTITY
SHIP TO ADDRESS
DODAAC / CAGE
30 dys. ADC
6
NSWC, CORONA DIVISION

KHAI TRINH

1999 FOURTH STREET

BLDG 204

NORCO CA 92860

951-273-4775 FOB: Destination N64267

To:

DELIVERY DATE
QUANTITY
SHIP TO ADDRESS
DODAAC / CAGE
30 dys. ADC
0
NSWC, CORONA DIVISION

KHAI TRINH

1999 FOURTH STREET

BLDG 204

NORCO CA 92860

951-273-4775 FOB: Destination N64267

(End of Summary of Changes) image1.wmf