TEST SUPPORT EQUIPMENT

PURCHASE REQUEST NUMBER:

TBD

1.0 INTRODUCTION

The Naval Surface Warfare Center (NSWC), Corona Division, Range Systems (RS) Engineering Department, Code 31 requires the purchase of Test & Support Equipment (T&SE) to facilitate calibration support, maintenance, testing, and troubleshooting capabilities across the range.

2.0 BACKGROUND

(State the name of the activity, location and what is required.)

The Pacific Northwest Electronic Warfare Range, which provides local training for Naval Air Station Whidbey aircrews against fixed and mobile threats, needs to acquire various test equipment to improve training, reduce maintenance costs, and facilitate troubleshooting to maintain test and calibration equipment in a constant state of readiness. In order to meet this requirement, the range requires an Analog and Digital Radio Test Set or equivalent as listed in the Specifications section below.

3.0 SPECIFICATIONS (identify salient characteristics, part numbers, descriptions, GSA contract numbers, if available and shipping requirements. See sample below) A CLIN should be provided for each piece of material or equipment requested. If the combined items identified are for the purchase of a system then only one CLIN is required. Request for manuals or training along with the material or equipment should each have a separate CLIN. If shipping is paid separately it should be a separate CLIN and is identified as CLIN 9999.)

Part#
Part Description/Salient Characteristics
Brand
Quantity
Unit Price
Delivery

3.1 PNW COMMS Analog & Digital Radio Test Set (000000001019102952)

3920B
Radio Test Set with Return Loss Bridge and the Following Options: 390XOPT055 Audio Analyzer;

390XOPT031 Tracking Generator;

And 390XOPT060 Harmonics and Spurious

Aeroflex, Brand Name or Equal To
1

10DAC

Salient Characteristics

- 390XOPT055 Audio Analyzer

- 390XOPT060 Harmonics & Spurious Measurements

- 390XOPT061 Tracking Generator

- AC4105 Return Loss Bridge 5MHz -2.0 GHz

- 1 GHz frequency range

- High performance FM/AM/SSB analog duplex test capabilities

- Sensitive receiver with built-in pre-amp

- Color coded pass/fail results

- -140 dBm (typical) DANL spectrum analyzer with up to 8 markers

- Dual-Channel oscilloscope up to 4 MHz

- Full audio analysis for AF level, frequency, SINAD and distortion measurements

- Up to 3 high accuracy audio modulators/function generators

- Up to 3 high accuracy audio baseband generators

- Tone encode and decode functionality including DTMF, DCS, tone remote, 2-tone sequential, and 5/6-tone

- GPIB, Ethernet, USB and RS-232 interfaces

- HP/Agilent 8920B remote emulation

- Up to 2.7 GHz frequency range extension