E80_20240418 Argon Gas Service for Seal Beach STATEMENT OF WORK.docx

DOCX document 20 KB Posted

Attached to
Argon Gas
Solicitation number
N6339424Q0039_24-SIMACQ-E80-0001
Issued by

About this file

This document is a Statement of Work for a federal contract opportunity to provide argon gas service, including rental of a 1,500 liter mini-bulk tank and delivery of 99.998% pure argon gas that meets MIL-PRF-27415C Grade A specification, to the NMCPAC CWD Unit at Seal Beach, California.

The key requirements include: installation of the mini-bulk tank (if needed), monthly rental of the 1,500 liter tank, delivery of argon gas refills when the tank reaches a differential level of 10, providing a Certificate of Analysis with each delivery to demonstrate the argon meets the required specification, hazardous materials disposal, and annual inspection and maintenance. The contract has a base period from October 1, 2024 to September 30, 2025, with four one-year option periods. Pricing is requested on a firm-fixed-price basis. The solicitation is a total small business set-aside with a NAICS code of 325120 and a response due date of June 15, 2024.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

NMCPAC CWD UNIT SEAL BEACH

ARGON MINI BULK TANK RENTAL AND ARGON SUPPLY DELIVERY

Background: NMCPAC CWD Unit Seal Beach uses Argon to test missiles at the Intermediate Level maintenance facility Building 907. The Argon system utilizes a 500 PSI input pressure to supply a 2-stage pneumatic pump that boost the pressure to 9000 PSI. The Argon specification that is required must meet MIL-PRF-27415C Grade A is 99.998% pure.

Scope: The government requires contractor support to supply Argon and to rent out a 1500L Mini-bulk tank. The Tank will be filled and refilled when the tank gets to a differential level of 10. The delivered Argon must have a Certificate of Analysis that must meet MIL-PRF-27415C Grade A or the delivery will be denied until MIL SPEC is met. The Argon Mini Bulk tank must not be depleted of Mini bulk tank supplied Argon at any time as to cause the High pressure Argon system to deflate and potentially cause the system to become contaminated.

MIL-PRF-27415C testing specifications Requirements:

N0024422P0114

1) Installation of Micro Bulk Tank (if required)

a. If new tank is to be installed, during this time of old tank removal and new tank install, a temporary argon supply (Meets MIL-PRF-27415C Grade A and accompany a Certificate of analysis) will be required to supply gas at the 500 PSI level.

2) Argon Micro Bulk storage of tank of 1500 Liter (42.950scf)

3) Argon Micro Bulk Tank monthly rental (42.950scf)

4) MIL-PRF-27415C Grade A 99.998% Argon Bulk Liquid Refill along with Certificate of Analysis with delivery (Customer will call when refills are required).

5) Hazardous Materials Disposal

6) Annual Inspection and Maintenance

7) Delivery for 99.998% Argon Bulk Liquid to:

Location: NMCPAC CWD Unit Seal Beach 800 Seal Beach Blvd., Bldg. 907 Seal Beach, CA 90740 Base Access:

ALL contractors entering the base must be able to pass a background check through identity proofing and vetting by submitting a completed SECNAV 5512 form to Naval Weapons Station Seal Beach (NWSSB) Pass & ID office via Government representative and provide two forms of valid government issued IDs. SECNAV 5512 form and List of Acceptable IDs can be provided by Government representative.