SHIP USS MONTPELIER (SSN 765)
ORIGINATOR: Tim Ledbetter DATE: 06 August 2019
1. SCOPE:
Title: INSPECT AND CLEAN FWD AND AFT VENTILATION SYSTEM
2. REFERENCE/PLANS:
2.1 Naval Surface Warfare Center, Carderock Division ltr 9514 Ser 9210/021 of 20 May 2009
3. REQUIREMENTS:
3.1 Ventilation cleaning shall be conducted in accordance with procedures approved by NAVSEA Code 05Z and the Life Cycle Manager, Carderock Division, Naval Surface Warfare Center (NSWCCD-SSES) Code 921.
3.2. Baseline CO2 and O2 readings shall be taken prior to starting any dry ice cleaning operations in every accessible compartment on the vessel.
3.3 All CO2 and O2 readings shall be taken before and after vent cleaning operations each day.
3.4 CO2 and O2 readings shall be monitored and recorded continuously and in every accessible compartment on the vessel during vent cleaning operations.
3.5 All CO2 and O2 readings shall be taken before and after vent cleaning operations each day.
3.6 CO2 and O2 readings shall be monitored and recorded continuously during vent cleaning operations.
Monitoring shall take place in every accessible compartment.
3.7 Cleaning shall cease anytime CO2 readings exceed 3000 ppm or O2 level drops below 19.6%. When the cleaning process has been stopped, identify the deficiency and correct. Once corrected and CO2 readings are below 2000 ppm and O2 readings are above 19.6%, then cleaning may be resumed.
3.8 In addition to the monitoring CO2 and O2 levels, all standard shipboard safety procedures shall be followed.
3.9 All workers must possess a valid DOD Secret Security clearance.
3.10 Clean FWD and AFT Ventilation System. Cleaning will include fans 3 through 9 and 12 through 21. Cleaning shall include all ventilation ducting and chillers associated with the listed fans.
4. NOTES:
4.1 USS MONTPELIER (SSN 765) located at the Naval Submarine Base, Groton, CT Pier 32N.
4.2 For Contractor personnel that do not have a CAC card or a NCACS card, the following is required to obtain DBIDS credentials to gain access the base:
| a. Ensure you provide the names of personnel requiring access to the SUBASE to the RSG POC. RSG will pass the information to the SUBASE Pass and ID office as your government sponsor. |
| b. Upon arrival at SUBASE, Present valid identification, Real ID Act-compliant state driver's license. If you don’t have a Real ID, you can use a passport. If you don’t have a passport you will be required to have an original birth certificate and your social security card. (not just your number). |
| c. Present a completed copy of the SECNAV 5512/1 form to obtain your background |
check. A copy of SECNAV 5512/1 can be obtained by contacting the RSG POC.
d. Upon completion of the background check, the Visitor Control Center representative will complete the DBIDS enrollment process, which includes your photo, finger prints, base restrictions, and several other assessments; after all this is done, you will be provided with your new DBIDS credential. You may now proceed to work.
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 None.
File details come from the government source that posted it.