This statement of work describes requirements for the fabrication of components for the COBRA EBS rebreather system. The Naval Surface Warfare Center Panama City Division requires the manufacture and delivery of 15 items within 20 business days of award, including outer tubes, inner tubes, valves, disks, knobs, panels, and other parts. Quotes are due by the closing date stated in solicitation N61331-24-T-TB04 and must include the vendor's CAGE code and lead time. The opportunity is set aside for the EDWOSB and quotes should be emailed to the point of contact provided, including the solicitation number and vendor name in the email subject line. The Department of the Navy is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to Fabricate Rebreather Components, newest first.
File Type Posted
C12 Supply Clauses.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK FOR

FABRICATION OF COBRA EBS SYSTEM COMPONENTS

1.0 SCOPE

The Naval Surface Warfare Center, Panama City Division, FL, (NSWC PCD) has a requirement for the fabrication of components from NSWC PCD drawings/CAD designs to support the COBRA project.

2.0 APPLICABLE DOCUMENTS

The following documents, of the exact issue shown, form a part of this SOW to the extent specified herein. In the event of conflict between the documents referenced herein and the SOW, the contents of this SOW shall take precedence.

2.1 Military Standards:

· None

2.2 Military Specifications:

· None

2.3 Other Documents:

· COBRA-11-11 Hose Adapter STEP file

· COBRA-11-12 Hose Coupling Nut RH STEP file

· COBRA-11-13 Hose Coupling Nut LH STEP file

· COBRA-12-01 Outer Tube STEP file

· COBRA-12-02 Inner Tube STEP file

· COBRA-12-03 Inhale Valve STEP file

· COBRA-12-04 Exhale Valve STEP file

· COBRA-12-05 Sealing Selector Disk STEP file

· COBRA-12-06 Selector Knob STEP file

· COBRA-13-06_A Panel Inner Rib STEP file

· COBRA-13-09 Clamp Front STEP file

· COBRA-13-11_Upper Panel Weldment STEP file

· COBRA-13-14 Upper Panel STEP file

· COBRA-13-16_Lower Panel Weldment STEP file

· COBRA-13-15 Lower Panel STEP file

3.0 REQUIREMENTS (CDRL A001)

The Contractor shall do manufacture and deliver the following items, to the tolerances specified, and provide Certificates of Conformance as specified below for each item. (CDRL A001)

Line
Description
Qty.
1
COBRA-11-11 - Hose Adapter STEP.STEP

Measurement: 59.05 mm x 40.64 mm x 40.64 mm | 18358.19 mm³ / 2.325 in x 1.600 in x

1.600 in | 1.120 in³ Process: CNC Machining Material: Aluminum 6061-T6 Finish: Black Anodize Tolerance: Tightest Tolerance: +/-.002"(+/-.051mm), Locations: 9

Surface Roughness: Smallest Roughness: 32uin/0.8um Ra, Locations: 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

2
COBRA-11-12 - Hose Coupling Nut RH STEP.STEP

Measurement: 50.80 mm x 50.80 mm x 17.78 mm | 11048.93 mm³ / 2.000 in x 2.000 in x

0.700 in | 0.674 in³ Process: CNC Machining Material: Aluminum 6061-T6 Finish: Black Anodize Threads and Tapped Holes: Threads and Tapped Holes, 1 Tolerance: Tightest Tolerance: +/-.005"(+/-.127mm) Surface Roughness: Smallest Roughness: 125uin/3.2um Ra Inspection: Standard Inspection Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification

3
COBRA-11-13 - Hose Coupling Nut LH STEP.STEP

Measurement: 50.80 mm x 50.80 mm x 17.78 mm | 10285.25 mm³ / 2.000 in x 2.000 in x

0.700 in | 0.628 in³ Process: CNC Machining Material: Aluminum 6061-T6 Finish: Black Anodize Threads and Tapped Holes: Threads and Tapped Holes, 1 Tolerance: Tightest Tolerance: +/-.005"(+/-.127mm) Surface Roughness: Smallest Roughness: 125uin/3.2um Ra Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

4
COBRA-12-01 - Outer Tube STEP.STEP

Measurement: 127.44 mm x 79.20 mm x 47.37 mm | 63364.34 mm³ / 5.017 in x 3.118 in x

1.865 in | 3.867 in³ Process: CNC Machining Material: Other, BLACK HYDEX 4101 Finish: Standard Tolerance: Tightest Tolerance: +/-.002"(+/-.051mm), Locations: 2 Surface Roughness: Smallest Roughness: 125uin/3.2um Ra Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration

5
COBRA-12-02 - Inner Tube STEP.STEP

Measurement: 108.31 mm x 41.22 mm x 41.22 mm | 30901.22 mm³ / 4.264 in x 1.623 in x

1.623 in | 1.886 in³ Process: CNC Machining Material: Other, BLACK HYDEX 4101 Finish: Standard Tolerance: Tightest Tolerance: +/-.005"(+/-.127mm) Surface Roughness: Smallest Roughness: 32uin/0.8um Ra, Locations: 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

6
COBRA-12-03 - Inhale Valve STEP.STEP

Measurement: 45.85 mm x 45.85 mm x 27.76 mm | 12158.57 mm³ / 1.805 in x 1.805 in x

1.093 in | 0.742 in³ Process: CNC Machining Material: Other, BLACK HYDEX 4101 Finish: Standard Tolerance: Tightest Tolerance: +/-.001"(+/-.025mm), Locations: 1 Surface Roughness: Smallest Roughness: 32uin/0.8um Ra, Locations: 1

Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

7
COBRA-12-04 - Exhale Valve STEP.STEP

Measurement: 45.85 mm x 45.85 mm x 27.69 mm | 10804.90 mm³ / 1.805 in x 1.805 in x

1.090 in | 0.659 in³ Process: CNC Machining Material: Other, BLACK HYDEX 4101 Finish: Standard Tolerance: Tightest Tolerance: +/-.001"(+/-.025mm), Locations: 1 Surface Roughness: Smallest Roughness: 32uin/0.8um Ra, Locations: 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

8
COBRA-12-05 - Sealing Selector Disk STEP.STEP

Measurement: 41.22 mm x 41.22 mm x 18.16 mm | 16679.86 mm³ / 1.623 in x 1.623 in x

0.715 in | 1.018 in³ Process: CNC Machining Material: Other, Black Hydex 4101 Finish: Standard Threads and Tapped Holes: Threads and Tapped Holes, 1 Tolerance: Tightest Tolerance: +/-.001"(+/-.025mm), Locations: 4 Surface Roughness: Smallest Roughness: 32uin/0.8um Ra, Locations: 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

9
COBRA-12-06 - Selector Knob STEP.STEP

Measurement: 50.80 mm x 50.79 mm x 16.76 mm | 10428.18 mm³ / 2.000 in x 2.000 in x 0.660 in | 0.636 in³ Process: CNC Machining Material: Other, Black Hydex 4101 Finish: Standard Tolerance: Tightest Tolerance: +/-.003"(+/-.076mm), Locations: 1 Surface Roughness: Smallest Roughness: 125uin/3.2um Ra Inspection: Standard Inspection Certificates and Supplier Qualifications: ITAR/EAR Registration

10
COBRA-13-06_A - Panel Inner RIb STEP.STEP

Measurement: 253.35 mm x 55.47 mm x 12.70 mm | 8152.61 mm³ / 9.974 in x 2.184 in x

0.500 in | 0.498 in³ Process: Sheet Metal Material: Aluminum 5052-H32 Finish: Clear Anodize Tolerance: Tightest Tolerance: +/-.020"(+/-.508 mm) Welding: Specify the total number of weld requirements.: 0 Part Marking: Laser Mark, 5 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

11
COBRA-13-09 - Clamp Front STEP.STEP

Measurement: 50.80 mm x 25.40 mm x 6.35 mm | 7232.91 mm³ / 2.000 in x 1.000 in x 0.250 in | 0.441 in³ Process: CNC Machining Material: Aluminum 6061-T6 Finish: Clear Anodize Tolerance: Tightest Tolerance: +/-.002"(+/-.051mm), Locations: 1 Surface Roughness: Smallest Roughness: 125uin/3.2um Ra

Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

12
COBRA-13-11_Upper Panel Weldment STEP.step

Measurement: 552.45 mm x 422.97 mm x 94.79 mm | 251956.34 mm³ / 21.750 in x 16.652 in x 3.732 in | 15.375 in³ Process: Assembly Inspection: Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

13
COBRA-13-14 - Upper Panel STEP.step

Measurement: 552.45 mm x 422.97 mm x 74.25 mm | 219345.92 mm³ /

21.750 in x 16.652 in x 2.923 in | 13.385 in³ Process: Sheet Metal Material: Aluminum 5052-H32 Finish: Clear Anodize Tolerance: Tightest Tolerance: +/-.020"(+/-.508 mm) Welding: Specify the total number of weld requirements.: 20 Part Marking: Laser Mark, 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

14
COBRA-13-16_ Lower Panel Weldment STEP.STEP

Measurement: 552.45 mm x 422.97 mm x 92.16 mm | 251568.69 mm³ / 21.750 in x 16.652 in x 3.629 in | 15.352 in³ Process: Assembly Inspection: Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Certificate of Conformance, DFARS Compliant Material Cert

15
COBRA-13-15 - Lower Panel STEP (2).STEP

Measurement: 552.45 mm x 422.97 mm x 74.25 mm | 218958.26 mm³ / 21.750 in x 16.652 in x 2.923 in | 13.362 in³ Process: Sheet Metal Material: Aluminum 5052-H32 Finish: Clear Anodize Tolerance: Tightest Tolerance: +/-.020"(+/-.508 mm) Welding: Specify the total number of weld requirements.: 0 Part Marking: Laser Mark, 1 Inspection: Formal Inspection with Dimensional Report Certificates and Supplier Qualifications: ITAR/EAR Registration, Finishing Certification, Certificate of Conformance, DFARS Compliant Material Cert

4.0 GOVERNMENT FURNISHED PROPERTY (GFP): None

5.0 DATA DELIVERABLES

Data shall be provided in accordance with the Contract Data Requirements List (CDRL) DD Form 1423.

6.0 PERIOD OF PERFORMANCE

The items listed in Section 3 of this document shall be delivered no later than 20 business days after award.

7.0 SECURITY

This requirement is UNCLASSIFIED. The Contractor will not require access to nor be required to generate classified information to perform the requirement.

RELEASE OF INFORMATION

(a) Release of information shall be in accordance with Section I, DFARS Clause 252.204-7000, Disclosure of Information.

(b) All technical data provided to the contractor by the Government will be protected from public disclosure in accordance with the markings contained thereon. All other information relating to the items to be delivered or services to be performed under this contract may not be disclosed by any means without prior approval of the appropriate NSWC PCD authority. Dissemination or public disclosure includes, but is not limited to, permitting access to such information by foreign nationals or by any other person or entity; publication of technical or scientific papers; advertising; or any other proposed public release. The contractor shall provide adequate physical protection to such information to preclude access by any person or entity not authorized such access by the Government.

7.1 Controlled Unclassified Information (CUI)

Controlled unclassified information (CUI) is official information that requires the application of controls and protective measures for a variety of reasons and has not been approved for public release, to include technical information, proprietary data, information requiring protection under the Privacy Act of 1974, and Government- developed privileged information involving the award of contracts. CUI is a categorical designation that refers to unclassified information that does not meet the standards for National Security Classification under Executive Order 13526, but is (a) pertinent to the national interest of the United States or to the important interests of entities outside the Federal Government, and (b) under law or policy requires protection from unauthorized disclosure, special handling safeguards, or prescribed limits on exchange or dissemination.

7.2 Minimum Requirements for Access to Controlled Unclassified Information (CUI)

Prior to access, Contractor personnel requiring access to Department of the Navy (DON) controlled unclassified information (CUI) or "user level access to DON or DoD networks and information systems, system security and network defense systems, or to system resources providing visual access and/or ability to input, delete or otherwise manipulate sensitive information without controls to identify and deny sensitive information" contractors must have clearance eligibility, or submit an Electronic Questionnaire for Investigation Processing (SF 86) to NSWC PCD Security for processing and subsequent adjudication by the DON Central Adjudication Facility.

7.3 Minimum Protection Requirements for Controlled Unclassified Information

Security classification guides and unclassified limited documents (e.g., CUI, Distribution Statement Controlled) are not authorized for public release and, therefore, cannot be posted on a publicly accessible webserver or transmitted over the Internet unless appropriately encrypted.

7.4 CUI

CUI is a designation, not a classification. CUI is used by Department of Defense (DoD) and a number of other federal agencies to identify information or material, which although unclassified, disclosure to the public of the information would reasonably be expected to cause a foreseeable harm to an interest protected by one or more provisions of the Freedom of Information Act (FOIA). This includes information that qualifies for protection pursuant to the provisions of the Privacy Act of 1974, as amended. CUI must be marked, controlled and safeguarded in accordance with DoDI 5200.48, DoD Information Security Program: Controlled Unclassified Information (CUI).

7.5 Security of Unclassified DoD Information on Non-DoD Information Systems (DoDI 8582.01)

DoD Policy: Adequate security shall be provided for all unclassified DoD information on non-DoD information systems. Appropriate requirements shall be incorporated into all contracts, grants, and other legal agreements with non- DoD entities.

Information Safeguards are applicable to unclassified DoD information in the possession or control of non-

DoD entities on non-DoD information systems, to the extent provided by the applicable contract, grant, or other legal agreement with the DoD.

Information Safeguards Unclassified DoD information that has not been cleared for public release may be disseminated by the Contractor, grantee, or awardee to the extent required to further the contract, grant, or agreement objectives, provided that the information is disseminated within the scope of assigned duties and with a clear expectation that confidentiality will be preserved. Examples include:

(a) Non-public information provided to a Contractor (e.g., with a request for proposal).

(b) Information developed during the course of a contract, grant, or other legal agreement (e.g., draft documents, reports, or briefings and deliverables).

(c) Privileged information contained in transactions (e.g., privileged contract information, program schedules, contract-related event tracking).

It is recognized that adequate security will vary depending on the nature and sensitivity of the information on any given non-DoD information system. However, all unclassified DoD information in the possession or control of non-DoD entities on non-DoD information systems shall minimally be safeguarded as follows:

(a) Do not process unclassified DoD information on publically available computers (e.g., those available for use by the general public in kiosks or hotel business centers).

(b) Protect unclassified DoD information by at least one physical or electronic barrier (e.g., locked container or room, logical authentication or logon procedure) when not under direct individual control of an authorized user.

(c) At a minimum, overwrite media that have been used to process unclassified DoD information before external release or disposal.

(d) Encrypt all information that has been identified as CUI when it is stored on mobile computing devices such as laptops and personal digital assistants, compact disks, or authorized removable storage media such as thumb drives and compact disks, using the best encryption technology available to the Contractor or teaming partner.

(e) Limit transfer of unclassified DoD information to subcontractors or teaming partners with a need to know and obtain a commitment from them to protect the information they receive to at least the same level of protection as that specified in the contract or other written agreement.

(f) Transmit e-mail, text messages, and similar communications containing unclassified DoD information using technology and processes that provide the best level of privacy available, given facilities, conditions, and environment. Examples of recommended technologies or processes include closed networks, virtual private networks, public key-enabled encryption, and transport layer security.

(g) Encrypt organizational wireless connections and use encrypted wireless connections where available when traveling. If encrypted wireless is not available, encrypt document files (e.g., spreadsheet and word processing files), using at least application-provided password protected level encryption.

(h) Transmit voice and fax transmissions only when there is a reasonable assurance that access is limited to authorized recipients.

(i) Do not post unclassified DoD information to website pages that are publicly available or have access limited only by domain or Internet protocol restriction. Such information may be posted to website pages that control access by user identification and password, user certificates, or other technical means and provide protection via use of transport layer security or other equivalent technologies during transmission. Access control may be provided by the intranet (vice the website itself or the application it hosts).

(j) Provide protection against computer network intrusions and data exfiltration, minimally including:

(1) Current and regularly updated malware protection services, e.g., anti-virus, anti-spyware.

(2) Monitoring and control of both inbound and outbound network traffic (e.g., at the external boundary, sub-networks, individual hosts), including blocking unauthorized ingress, egress, and exfiltration through technologies such as firewalls and router policies, intrusion prevention or detection services, and host-based security services. Prompt application of security-relevant software patches, service packs, and hot fixes.

(k) Comply with other current Federal and DoD information protection and reporting requirements for specified categories of information (e.g., medical, proprietary, Critical Program Information (CPI), personally identifiable information, export controlled) as specified in contracts, grants, and other legal agreements.

(l) Report loss or unauthorized disclosure of unclassified DoD information in accordance with contract, grant, or other legal agreement requirements and mechanisms.

(m) Do not use external IT services (e.g., e-mail, content hosting, database, document processing) unless they provide at least the same level of protection as that specified in the contract or other written agreement.

7.6 Operations Security

Operations Security (OPSEC) is concerned with the protection of critical information: facts about intentions, capabilities, operations, or activities that are needed by adversaries or competitors to bring about failure or unacceptable consequences of mission accomplishment.

Critical information includes information regarding:

· Operations, missions, and exercises, test schedules or locations;

· Location/movement of sensitive information, equipment, or facilities;

· Force structure and readiness (e.g., recall rosters);

· Capabilities, vulnerabilities, limitations, security weaknesses;

· Intrusions/attacks of DoD networks or information systems;

· Network (and system) user identifications and passwords;

· Movements of key personnel or visitors (itineraries, agendas, etc.); and

· Security classification of equipment, systems, operations, etc.

The Contractor, subcontractors and their personnel shall employ the following countermeasures to mitigate the susceptibility of critical information to exploitation, when applicable:

· Practice OPSEC and facilitate OPSEC awareness;

· Immediately retrieve documents from printers assessable by the public;

· Shred sensitive and Controlled Unclassified Information (CUI) documents when no longer needed;

· Protect information from personnel without a need-to-know;

· When promulgating information, limit details to that essential for legitimacy; during testing and evaluation, practice OPSEC methodologies of staging out of sight, desensitization, or speed of execution, whenever possible.

8.0 DISTRIBUTION LIMITATION STATEMENTS

Technical Documents generated under this contract shall carry the following Distribution Limitation Statements. Word-processing/CAD files shall have the statements included in the file such that the first page of any resultant hard copy shall display the statements. For drawings, the statements shall be as near to the title block as possible without obscuring any detail of the drawing. Additionally, each diskette delivered shall be marked externally with the statements.

DISTRIBUTION STATEMENT D: DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE AND

U.S. DOD CONTRACTORS ONLY (ADMINISTRATIVE/OPERATIONAL USE) (DATE STATEMENT APPLIED). OTHER U.S. REQUESTS FOR THIS DOCUMENT MUST BE REFERRED TO PEO-LCS (PMS495). (PER THE SCG).

DESTRUCTION NOTICE – FOR CLASSIFIED DOCUMENTS, FOLLOW THE PROCEDURES IN

NISPOM RULE OR DODI 5200.01-V-3, DoD INFORMATION SECURITY PROGRAM REGULATION. FOR CONTROLLED UNCLASSIFIED, DOCUMENTS, DESTROY PER DODI 5200.48, CONTOLLED UNCLASSIFIED INFORMATION (CUI).

9.0 ENTERPRISE-WIDE CONTRACTOR MANPOWER REPORTING APPLICATION (ECMRA)

The Contractor shall report ALL Contractor labor hours (including Subcontractor labor hours) required for performance of services provided under this Contract for NSWC PCD via a secure data collection site. The Contractor is required to completely fill in all required data fields using the following web address https://doncmra.nmci.navy.mil. Reporting inputs will be for the labor executed during the period of performance during each Government Fiscal Year (FY), which runs October 1 through September 30. While inputs may be reported any time during the FY, all data shall be reported no later than October 31 of each calendar year. Contractors may direct questions to the help desk, linked at https://doncmra.nmci.navy.mil.