STATEMENT OF WORK

Ship: USS Pasadena SSN-752

JSN: 21413-EAMC-Q871/Q872/Q923

SOW # 660-11-001

Planner: Tom Loepfe

SSP-036-15

COAR: 26-036

1. SCOPE:

1.1 Title:

Temporary Air Compressor; provide

1.2 Location of Work:

1.2.1 Pier Side

1.3 Identification:

1.3.1 Quantity (One) each, High Pressure Air Compressor(HPAC); 17 CFH, 4500 PSIG 1.3.2 Quantity (One) each, Electric Driven Low Pressure Air Compressor(LPAC); 200 CFM, 125 PSIG

1.3.3 Quantity (25) Feet, Ground cable with 5/8” lug on each end.

1.3.4 Quantity (One) each, High Pressure Air Dryer (HPAD), Minimum Dewpoint -60 Deg F.

2. REFERENCES:

2.1 NAVSEA Standard Items

3. REQUIREMENTS:

3.1 Provide and maintain Pier Side Temporary High Pressure Air Compressor identified in 1.3.1 with all required hoses and fittings required to connect to the Ships High Pressure Air system.

3.1.1 Electrical connections must be 440V, 3 phase with 5/8” lug on each cable end. Must be capable of connecting to a Navy Joy connector pigtail.

3.1.2 Submit one legible copy, in hard copy or electronic media, of a report listing the results of 3.1 to the SUPERVISOR.

3.2 Provide and maintain Pier Side Temporary Low Pressure Air Compressor identified in 1.3.2 with all required hoses, pier manifold with a minimum of (2) ea 1/2”, Hansen fittings , (2) ea 5/8” Hansen fittings and (2) ea. Chicago type fittings, required to provide Ships Force with pier Low Pressure Air.

3.2.1 Electrical connections must be 440V, 3 phase with 5/8” lug on each cable end. Must be capable of connecting to a Navy Joy connector pigtail.

3.2.2 Submit one legible copy, in hard copy or electronic media, of a report listing the results of 3.2 to the SUPERVISOR.

3.3 Provide and maintain Pier Side Temporary High Pressure Air Dryer identified in 1.3.4 with all required hoses, shut off valves, and cartridges to maintain dry air at a minimum of -60 DEG F

3.3.1 Submit one legible copy, in hard copy or electronic media, of a report listing the results of 3.3 to the SUPERVISOR.

3.4 Removal of each equipment identified in 1.3.1 through 1.3.4 will be directed by the SUPERVISOR.

4. NOTES: