Statement_of_Work_C943_Pump_Shop.pdf
PDF 63 KB Posted
- Attached to
- C943 Prefabricated Office Module
- Solicitation number
- N50054-17-R-0007
About this file
Statement of Work
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bidders_Questions_N50054-17-R-0007.pdf | ||
| ODP.XLS | XLS spreadsheet | |
| N50054-17-R-0007_MARMC_C943_Pump_Shop.pdf | ||
| CONTRACTOR_VISIT_REQUEST_INSTRUCTIONS_new_Fax-phone_113016.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A. Supply Description
• Quantity: (1) Four Wall non-load bearing modular office unit
• Modular Dimensions: 20’ x 12’ x 9’H
• Door
− Single Door located on the South end along the 12’ wall − Dimensions: 3’W x 7’H with Half Glass Window, lockset, door sweep, door closure and threshold − Commercial Grade Steel
• Wall Panels − 3” panels with ½” vinyl coated gypsum board on both sides of a Polystyrene Core − Color: White
NOTE: Wall panels shall carry Class “A” flame spread rating IAW ASTM E-2768
• All posts, floor track, top track etc. shall be made of non-corrosive painted aluminum alloy
− Color: Grey
• Windows
− Quantity (5) − ¼” Tempered Glass; 4’Wx3’H fixed type − Located along 20’ wall facing into shop entrance
• Power, Wiring and Lighting − Wiring system - LOT UL Approved for modular units − 1 each; 125 AMP Single Phase Panel Board with Breakers and (8) spaces − 3 each; 120 Volt lay in (Recessed) Fluorescent T8 light Fixtures, 2’ x 4’ − 1 each; 120 Volt x 20 AMP Single Pole Light Switch − 6 each, 120 Volt x 20 AMP Duplex Receptacles − 1 each; 230 Volt dedicated AC/Heat Unit Receptacle
• HVAC Unit − 1 each; 11,600 BTU heat/cool, commercial grade AC/Heat Unit (230) Volts with sealed refrigeration system (NOTE: Unit must be re-circulate condensate therefore no need for a condensate drain line) − 1 each; Electronic Digital Thermostat
• Data/Phone:
− 3 – Phone / CAT 5E Computer Jack Boxes in wall type (wiring run by customer)
• Ceiling / Roof:
− 240 SQFT of 2’ x 4’ White mineral acoustical ceiling tiles and grid system − 240 SQFT of 20 Gauge Type “B” Corrugated Roof Decking with Rubber Closers − 240 SQFT of Ceiling Insulation, 2” x R-7
• Floor − 240 SQFT Wood Laminate (Not Hardwood) − Color: To be selected by customer
• 1 each; Exit Light
• Modular Unit shall have Fire Sprinkler system with the ability to connect to existing building sprinkler system
NOTE: All electrical, data, phone connections and Fire Sprinkler connections will be installed by MARMC.
B. Delivery Date: 09 June 2017
C. Mandatory Site Visit
Date: 27 March 2017 Time: 10:00 AM Address:
Mid-Atlantic Regional Maintenance Center (MARMC) 9170 Second ST.
Norfolk, VA. 23511 Bldg. CEP-200
Note:
1. Attendance to the mandatory site visit is required.
2. See Contractor Visit Request Instruction for building access procedure.
D. Delivery Location
Mid-Atlantic Regional Maintenance Center (MARMC) 9170 Second ST.
Norfolk, VA. 23511 Bldg. CEP-200 / Attn: Facilities Code 1150 and/or Code 943
File details come from the government source that posted it. Updated .