015_RFC_YTB-836.pdf
PDF 39 KB Posted
- Attached to
- YTB-836 Habor Tug Federal contract opportunity
- Solicitation number
- N4523A-17-R-0009
About this file
RFC 0015: Repair fathometer transducer
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N4523A-17-R-0009_Amendment_4.pdf | ||
| 017_RFC_YTB-836.pdf | ||
| 013_RFC_YTB-836.pdf | ||
| 012_RFC_YTB-836.pdf | ||
| 009_RFC_YTB-836.pdf | ||
| 016_RFC_YTB-836.pdf | ||
| 014_RFC_YTB-836.pdf | ||
| 011_RFC_YTB-836.pdf | ||
| 010_RFC_YTB-836.pdf | ||
| N4523A-17-R-0009_Amendment_3.pdf | ||
| 205-4563432A1_Stack_Detail.pdf | ||
| YTB_836__5-Way_Breakdown_Sheet_Erratta_1.xls | XLS spreadsheet | |
| 008_RFC.pdf | ||
| 007_RFC.pdf | ||
| Amend_2.pdf | ||
| 006_RFC.docx | DOCX document | |
| 004_RFC.docx | DOCX document | |
| 003._RFC.docx | DOCX document | |
| 005_RFC.docx | DOCX document | |
| REQUEST_FOR_SPECIFICATION_CLARIFICATION_0002.docx | DOCX document | |
| amend_1.pdf | ||
| Dec15YTB_836__5-Way_Breakdown_WKG.xls | XLS spreadsheet | |
| YTB_BID_Q_1).docx | DOCX document | |
| REQUEST_FOR_SPECIFICATION_CLARIFICATION.docx | DOCX document | |
| CDRL_&_DID.pdf | ||
| N4523A-17-R-0009.pdf | ||
| YTB_836__5-Way_Breakdown_WKG.xls | XLS spreadsheet | |
| SOW_YTB_836_FY17.pdf |
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR SPECIFICATION CLARIFICATION
DATE OF REQUEST: 12-22-2017 QUESTION NO: 015
REQUIREMENT: Electrical systems REQUISITION NO.: N4523A-17-R-0009
ITEM NO: 3.10.1.1
TITLE: Repair Fathometer Transducer
ISSUING OFFICE POC(CODE 446):
LeAundria Shaheed: (360) 476-4053 Leaundria.shaheed@navy.mil
PARA. NO: 3.10.1.1 PAGE NO: 41 CONTRACTOR:
PLANNER’S NAME: ATTACH. NO: NA CONTRACTOR POC & PHONE:
CONTRACTOR QUESTION: (ONE QUESTION PER PAGE)
In the Navy’s response; 008 RFC, the transducer the Navy had sent for an updated PN is 7511-100SP1.
Is there a typographical error here as the part number listed is the one high-lighted below. There is a “2” in front of the P1 and not an “S”.
Neither one of these part numbers are still supported as the units were discontinued approximately 16 years ago and no replacement parts are known, according to the RayMarine Factory.
Will the navy please supply a current model number transducer that is available?
Does the Navy want a complete assembly replaced or just the transducer.
DO NOT WRITE BELOW THIS LINE
SPEC CHG: Y/N DWG/REF CHG. Y/N RQMTS CHG: Y/N MAT'L CHG: Y/N
TECHNICAL REVIEW: SERIAL NO:
Errata 1 issued to reflect ‘repair’ vice ‘replace.’
ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING
OFFICE POC NO LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST
FOR PROPOSAL.