Connectivity Statement of work_REDACTED.pdf
PDF 172 KB Posted
- Solicitation number
- N42158RC0001
About this file
This document is a Statement of Work (SOW) for a federal contract opportunity to create and install a WinCC Open Architecture v3.19 project at the Norfolk Naval Shipyard. The scope of work includes reviewing and collecting production metrics from specified CNC machines located in Building 171 using the WinCC OA software. The contractor will develop and install the WinCC OA project to collect data from the CNC machines and log it to a Siemens Server. This is a Proof of Concept project to determine which CNC machines can provide data to the database. The period of performance is from November 11, 2024 to June 8, 2026. Key contractor responsibilities include project management, communication, and scope oversight. NNSY responsibilities include providing an escort, installing cabling, and ensuring industrial equipment has the proper software. The contract opportunity is for the "WinCC Open Architecture v3.19 Project-Proof of Concept ONLY" with Solicitation Number N42158RC0001, issued by the Department of the Navy Naval Sea Systems Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Presolicitation Notice - Sole Source.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
Create a WinCC Open Architecture v3.19 project and install the project at the Norfolk
Naval Shipyard shipyards.
1. SCOPE OF WORK
1.1. This scope covers the requirements to review and to collect production metrics from specified
CNC machines located in Bldg. 171. 1st Floor using programming WinCC OA V3.19.
1.2. Norfolk Naval Shipyard (NNSY) will provide the computers where the WinCC OA software and
MS SQL, specifically MTLINK I, will be installed to communicate with Siemen Server Simatic Rack
PC no. 1PC547J. WinCC OA licenses and MS SQL installation media and licenses to be provided by customer.
1.3. Delivery to: B171, 1st. Floor, Machine Section, Norfolk Naval Shipyard, Portsmouth, VA.
1.4. Contractor will develop and install a WinCC OA project specific to the specified CNC machines determined by NNSY to collect data from these machines to be logged to the Siemen Server Simatic
Rack PC no. 1PC547J.
1.5. Testing will be performed by the Seller at the Customer site in the Naval Shipyard located in
Norfolk, Virginia, USA and by the Customer at the Customer’s site.
1.6. NNSY will provide the Contractor with computers and Siemen will provide the server rack
1PC547J.where the WinCC OA software and MS SQL will be installed. WinCC OA licenses and MS
SQL installation media and licenses to be provided by customer
1.7. This is a Proof of Concept ONLY project to determine which CNC machines can provide data to the data base.
1.8. NNSY will list the specific metrics and actual data names from each CNC machine that needs to be monitored and logged by the WinCC OA v3.19 project to include any visualization of the graphics
Screens through Siemens Simatic Human Machine Interface (HMI) C-FDJ6948
2. Period of Performance: November 11, 2024-June 8,2026
3. SERVICE: (Contractor Responsibilities)
Project Manager
3.1.1. Overall scheduling and coordination of project on behalf of Contractor.
3.1.2. Communication of all scope, financial and commercial information to Customer.
3.1.3 Improvement and maintenance of the Project Plan and any changes to the matter of software thereto.
3.1.4 Overseer of the scope.
3.1.5 The Project Manager is the primary communication interface point and will be responsible for coordinating, overseeing, scheduling task, reviewing and expediting all requests for data, meetings, for submitted documents in support of project activities.
1. NNSY Responsibilities:
1.1 NNSY shall provide an escort for contractors’ access into controlled industrial area.
1.2 NNSY shall be responsible for installing Cat 5E cable to port of machine.
1.3 NNSY shall be responsible for ensuring Industrial Portable Equipment (IPE) has the proper updated software to communicate with WinCC OA V3.19.
1.4 NNSY shall be responsible for all wiring and network connections to main communication port of
IPE.
2. Safety: "Per FAR 22.102-1(a) entitled "Safety", Contractors are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard cognizance must follow Federal and
State OSHA requirements; Norfolk Naval Shipyard OSHE Program Manual, NAVSHIPYDNORINST
P5090.2 requirements; OSHE Control Manual (OSHECM) requirements; or safety requirements for site specific location of the contract."
3. Security: Contractor shall comply with the following security requirements.
3.1. Initial Entry: Companies seeking access to the shipyard must provide to the technical representative a request under the company’s letterhead, detailing the full name, social security number, gender, race, place and date of birth of each worker. A company officer must sign this letter. This will be endorsed by the TPOC and forwarded to the NNSY Pass Office.
3.2. Vehicle Entry: The company name shall be displayed on each door of the Contractor's vehicles in a manner and size that is clearly visible. All vehicles shall display a valid state license plate that complies with State Vehicle Code. Vehicles shall meet all other requirement of the State
Vehicle Code, such as safety standards, and shall carry proof of insurance and state registration.
Passes will be issued for vehicles to enter the shipyard. A separate pass is required for entering the
Controlled Industrial Area (CIA).
3.3. Portable Electronic Device (PED): In accordance with
COMSUBLANT/COMSUBPACINST 2075.1C, the use of Portable Electronic Devices (PEDs) while in or on Department of Navy Controlled, Industrial Areas are prohibited. A portable electronic device (PED) is defined as any non-stationary electronic apparatus with singular or multiple capabilities of, but not limited to recording, storing, and/or transmitting data, voice, video, or photo images e.g.: cell phones, laptops, tablets and wearable devices such as fitness bands and smart watches
4. Critical time Constraints: The Installation shall be performed between the hours of 7:20 am and 16:00 pm
Monday through Friday excluding any federal holidays.
5. Location: Building 171, 1st. floor, Code 930.
6. Technical POC: Steven Watson, steven.f.watson.civ@us.navy.mil Phone: 757-738-5910
7. Certifying POC: Marc Lauture, marc.e.lauture.civ@us.navy.mil Phone: 757-373-5994
8. Travel Charge: All travel will be IAW Joint Travel Regulation and calculated at the prevailing JTR rates.
File details come from the government source that posted it. Updated .