N4215823Q0036 - ATTACHMENT A.pdf
PDF 360 KB Posted
- Solicitation number
- N4215823Q0036
About this file
This document is an attachment to a solicitation for the rental of five refrigerated containers for a period of two months.
The attachment provides technical specifications for the refrigerated containers, which must each be a minimum of 8' wide x 8' high x 40' long, electrically powered to run continuously, and capable of maintaining temperatures between -3 and 42 degrees Fahrenheit. Additional requirements include withstanding 110 mph winds, being water resistant, having forklift channels and pad eyes for lifting, swinging outward doors that can be locked, and meeting applicable safety regulations. Contractors must certify compliance with each technical capability and provide a lifting sketch or rigging diagram. Refrigerated containers must also be labeled with identifying information including the contractor's contact details and government contract number. The solicitation was issued by the Department of the Navy Naval Sea Systems Command for the rental of refrigerated containers to store food or medicine for a two month period.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N4215823Q0036_TRUMAN REEFERS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT A – N4215823Q0036
See below for: TECHNICAL CAPABILITY/CONTRACTOR/RESPONSIBILITY CERTIFICATION
STATEMENT
Vendor shall certify for equipment quoted that his product meets each capability listed below by initializing at the bottom. In order to be considered for award, this must be completed and submitted with your quote.
Technical Capabilities Statement
Item #0001 FIVE (5) 40FT REFRIGERATED BOXES
Shall be provided with the following capabilities, features, and specifications: YES NO
1. The 40FT REFRIGERATED BOXES shall be cleaned, disinfected, and ready to store food or medicine prior to delivery.
2. The 40FT REFRIGERATED BOXES shall be a minimum of 8’ wide x 8’ high (not including refrigeration unit) x 40’ long.
3. The 40FT REFRIGERATED BOXES shall be electrically powered and capable of running 24 hours a day / 7 days a week. See attached enclosures
(1), (2), (3) and (4).
4. The 40FT REFRIGERATED BOXES shall be rated at 200 amps or less. See attached enclosures (1), (2), (3) and (4).
5. The 40FT REFRIGERATED BOXES shall be capable of keeping a constant temperature of -3 degrees to 42 degrees (Fahrenheit).
6. The 40FT REFRIGERATED BOXES shall be hurricane proof to 110 MPH winds and also must be water resistant.
7. The 40FT REFRIGERATED BOXES have forklift channels 5”x10” inside dimension the full width of the unit and enclosed on sides.
o Each unit that has forklift connections in lieu of overhead rigging equipment and associated gear
8. The 40FT REFRIGERATED BOXES shall have no windows in the units.
9. The 40FT REFRIGERATED BOXES shall have exterior camlok connections to box feeding a 600 Volt, 40A (amp) 2-pole circuit breaker enclosed in a
NEMA 3R enclosure feeding a 15kva, 440/240V primary:240/120V secondary, single-phase transformer. This is to feed a 15 kva, 480/240 volt primary, 240/120 volt secondary single phase transformer (see enclosure (2)).
See enclosure (4) for a list of exterior equipment. Equivalent material may be substituted. Power cable end fittings (camlok) will be lugged and color coded to indicate proper phasing. See attached enclosures (1), (2), (3) and (4).
10. The 40FT REFRIGERATED BOXES shall be in compliance with applicable
NFPA and NEC requirements.
11. The 40FT REFRIGERATED BOXES shall comply with the applicable
OSHA regulations.
12. The 40FT REFRIGERATED BOXES shall have unit doors which swing outward and the doors must be capable of being locked.
13. The 40FT REFRIGERATED BOXES shall be capable of being moved via forklift and/or lifting pad eyes. Unit shall have weight clearly marked for lifting purposes.
14. The 40FT REFRIGERATED BOXES shall be outfitted with suitable attachments for overhead lifting (if applicable).
ATTACHMENT A – N4215823Q0036
o Each lifting attachment shall:
Be capable of supporting one half the gross weight of the equipment with a design factor of five to one based on ultimate strength.
Be designed to accept a standard anchor shackle (Federal
Specification RR-C-271D, type IVA) which is capable of supporting one half the gross weight of the equipment.
Be such that the shackles are not side loaded. This is not applicable for forklift lifting.
Be conspicuously marked in a contrasting color “Lift
Here”. Letters shall have a minimum height of 1”.
15. The 40FT REFRIGERATED BOXES shall be provided with a lifting sketch / rigging diagram.
o The lifting sketch shall detail any specific requirements and / or configurations that must be meet prior to lifting (i.e. “engage swing lock”, “Tilt mast back fully”, “Rotate lifting basket over side”, “Utilize 10’ minimum length slings”, “Spreader beam required”, etc.).
16. The 40FT REFRIGERATED BOXES shall have a decal affixed with all identifying markings to include:
o Contractor’s name and point of contact information (name, tele#, etc) o Government Contract Number; Contracting Officer’s information
(name, tele#, etc) o Unique number (different for each unit) o Vessel Name/Code o The decal shall have the following: minimum of 8.5” x 11” in size, white in color with black writing. The decal is to be located on one of the doors of the unit. If the half of the unit does not have a door, an 11/3” x 4” at minimum label shall be placed on the electrical panel on the inside of the unit.
TECHNICAL CAPABILITY/CONTRACTOR RESPONSIBLITY CERTIFICATION
Vendor hereby certifies that his/her service meets or exceeds all specifications in this solicitation, in their entirety, with no exceptions.___________________ (initials)
File details come from the government source that posted it. Updated .