ATTACHMENT (1)

TECHNICAL CAPABILITY CERTIFICATIONS

Vendor shall self-certify that the equipment and services proposed either meets or does not meet the Government’s minimum requirements specified in the associated Statement of Work (SOW) reference by initialing in the “YES” or

“NO” area of the chart below.

Any deviation to the Government specifications shall be identified as such – A detailed explanation shall be provided for each negative response.

Note: In order to be considered for award, the table must be completed in its entirety and submitted with your quotation in accordance with the Instructions of Offerors.

Technical Capabilities Statement

Two (2) Regenerative Air Dryer Units

Shall be provided with the following capabilities, features, and specifications:

YES NO

Each regenerative air dryer shall be capable of handling at least 930 cubic feet a minute (CFM) at 125 psig. Each regenerative air dryer must be able to provide a dew point of -70 degrees F.

The regenerative air dryers shall be electrically powered, suitable for

110/120 VAC, 1-phase, 60HZ. The dryers shall be self-contained so that the system is capable of producing dry air WITHOUT any additional utilities.

The regenerative air dryers must provide oil-free air.

The regenerative air dryers must be capable of running 24 hours/day, 7 days/week, for the duration of the POP

The regenerative air dryers shall be equipped with fully automatic switching controls, alarms, and indicators so that the dryer package requires monitoring no more than once every 24 hours by operators after start-up.

Regenerative Air Dryers are to be heatless, non-refrigerated, twin tower design of a regenerative nature utilizing hygroscopic desiccant with automatic condensate purges. One tower shall provide dry air while the other is in regeneration mode.

Units will be in continuous use outdoors, and will be directly exposed to everyday weather and salt water air. All exposed components must be weather resistant. All components must meet or exceed NEMA Type 4 for outdoor use. It is the contractor’s responsibility to provide any protective coverings for the units.

The regenerative air dryers shall be wholly contained in one container or skid per dryer. The containers/skids shall be constructed to be portable, capable of being both transported by forklift and crane.

The equipment shall be outfitted with suitable attachments for overhead lifting. Each lifting attachment shall be capable of supporting one half the gross weight of the equipment with a design factor of five to one based on ultimate strength.

Each lifting attachment shall be designed to accept a standard anchor shackle (Federal Specification RR-C-271D, type IVA) which is capable of supporting one half the gross weight of the equipment. Design of the lifting attachments shall be such that the shackles are not side loaded.

Each lifting attachment shall be conspicuously marked in a contrasting color “Lift Here”. Letters shall have a minimum height of 1”.

The equipment shall be marked in a prominent location with the gross weight. Marking shall be upper case letters of a contrasting color, with a minimum height of 1”. Marking shall include the units (i.e. “pounds”, “long tons”, etc.).

The equipment shall be provided with a lifting sketch / rigging diagram.

The lifting sketch shall detail any specific requirements and / or configurations that must be met prior to lifting (i.e. “engage swing lock”, “Tilt mast back fully”, “Rotate lifting basket over side”, “Utilize

10’ minimum length slings”, “Spreader beam required”, etc.).

The regenerative air dryers shall comply with the applicable OSHA regulations.

The regenerative air dryers shall comply with the applicable ASME

Boiler and Pressure Vessel Code.

Relief valves shall have intact wire seals on their adjustment caps and shall bear tags indicating the set point, testing activity and test date.

Pressure gauges shall be in calibration to manufacturer standards and shall bear labels showing calibration which will not expire during the contract period.

Power cable end fittings will be lugged and color coded to indicate proper phasing.

The inlet and outlet of each Regenerative Air Dryer shall be 2” Male

NPT. If unit is not equipped with 2” Male NPT inlet/outlet connections, contractor shall provide and preinstall adapters as required at no cost to the government.

The regenerative air dryers shall have the (1) air capacity, (2) minimum/maximum supply pressure, (3) minimum/maximum operating temperature, and (4) the dew point range stamped on a metal plate attached to the equipment. Each major component of the system shall have the manufacturer's name and the manufacturer's serial number stamped on a metal plate attached to the component. No metal stamping is permitted on any surface subjected to high stresses in service, except as permitted by the applicable portions of the ASME Boiler and

Pressure Vessel Code.

Provide 24 hour a day, seven-day a week on-call repair service during the rental period at no additional charge.

(Insert Initial/Date) hereby certifies the equipment/services proposed meet or exceed all Government Minimum

Specifications.

(Insert Initial/Date) hereby certified the equipment/services proposed meet or exceed the Government Minimum

Specifications with the following deviation/exceptions

(Provide separately detailed explanation for each SOW association)