Steam Valve Salients - AS 2024.04.26.xlsx

XLSX spreadsheet 110 KB Posted

Attached to
USS FRANK CABLE STEAM VALVES
Solicitation number
N4044626Q5002
Issued by

About this file

This is a procurement specification document detailing steam valve requirements for the USS Frank Cable (T-ALT AS-39-19018), a naval auxiliary ship. The specification outlines salient characteristics and design data for six distinct steam valve systems required for the vessel's propulsion and auxiliary systems.

The procurement requires six steam valve assemblies: two 6-inch superheater steam stop valves with motor-operated (MOV) controls for port and starboard applications; two 5-inch desuperheater outlet steam stop valves with MOV controls for port and starboard applications; one 2.5-inch desuperheater steam to soot blowers valve; and one 4-inch main feedwater stop/check valve to economizer and boiler. All valves feature 600LB pressure class rating with bolted bonnet construction, CR-13 stems, and Stellite hard-faced seats and discs per ASME B16.10 and B16.34 standards. The first four valves incorporate 440V, 3-phase, 60Hz motor operators with 15-second cycle times and two contactors for push-button close/open functions with indicator lights. Construction materials vary by application: CR-MO (Cast or Forged) per A217 Grade WC6 or A182 Grade F11 CL2 for superheated steam applications, and Carbon Steel per A216 Grade WCB or A105 for lower-temperature applications. Design pressures range from 705 psig for superheated steam systems to 920 psig for the feedwater system, with operating temperatures from 263°F to 875°F depending on the application.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Procurement Spec

General InfoShip ClassASASASASASAS
ServiceSuperheater Steam Stop Valve w/ MOV (Port)Superheater Steam Stop Valve w/ MOV (Stbd)Desuperheater Outlet Steam Stop Valve w/ MOV (Port)Desuperheater Outlet Steam Stop Valve w/ MOV (Stbd)Desuperheater Steam to Soot Blowers ValveMain Feed Water Stop/Check to Economizer & Boiler Valve
Velan Dwg.B14-2085B-05TS-M w/ BypassB14-2085B-05TS-M w/ BypassB13-2085B-02TS-M w/ BypassB13-2085B-02TS-M w/ BypassB09-2074B-02TSB12-2074B-02TS
Reference Dwg.207-4792286207-4792286514-4792911514-4792911514-4792911208-4792296
Ref Dwg Valve(V-1 & V-2)(V-1 & V-2)(V-3 & V-4)(V-3 & V-4)(V-70 & V71)(V-93 & V-94)
Qty./Ship111122
Salient CharacteristicsValve TypeAngle Globe
Stop-Check (OS&Y)Angle Globe
Stop-Check (OS&Y)Globe
Stop-Check (OS&Y)Globe
Stop-Check (OS&Y)Globe Stop (OS&Y)Globe Stop (OS&Y)
BypassY, 3/4", Series A, LH of FlowY, 3/4", Series A, RH of FlowY, 3/4", Series A, LH of FlowY, 3/4", Series A, RH of FlowNoNo
Size6"6"5"5"2-1/2"4"
Sys. Pipe SCH404040404040
Design DataPressure (psig)705705705705705920
Temp (°F)875875725725725263
MediumSuperheated SteamSuperheated SteamDesuperheated SteamDesuperheated SteamDesuperheated SteamFeedwater
ConstructionMaterialCR-MO
(Cast or Forged)CR-MO
(Cast or Forged)Carbon Steel
(Cast or Forged)Carbon Steel
(Cast or Forged)Carbon Steel
(Cast or Forged)Carbon Steel

(Cast or Forged)

StandardA217 Gr. WC6 or
A182 Gr. F11 CL 2A217 Gr. WC6 or
A182 Gr. F11 CL 2A216 Gr. WCB or
A105A216 Gr. WCB or
A105A216 Gr. WCB or
A105A216 Gr. WCB or

A105

Design Standard(s)ASME B16.10 & B16.34ASME B16.10 & B16.34ASME B16.10 & B16.34ASME B16.10 & B16.34ASME B16.10 & B16.34ASME B16.10 & B16.34
Pressure Class600LB600LB600LB600LB600LB600LB
EndsButt WeldButt WeldButt WeldButt WeldButt WeldButt Weld
Bonnet-StyleBolted BonnetBolted BonnetBolted BonnetBolted BonnetBolted BonnetBolted Bonnet
StemCR-13CR-13CR-13CR-13CR-13CR-13
SeatStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-Faced
DiscStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-FacedStellite/Hard-Faced
Motor OperatorVoltage440440440440N/AN/A
Hz60606060N/AN/A
Ph3333
Cycle Time15 sec.15 sec.15 sec.15 sec.N/AN/A
Input/Output RequirementsTwo (2) Contactors - Push Button Close
One (1) Contactor - Indicator Light Open/CloseTwo (2) Contactors - Push Button Close
One (1) Contactor - Indicator Light Open/CloseTwo (2) Contactors - Push Button Close
One (1) Contactor - Indicator Light Open/CloseTwo (2) Contactors - Push Button Close

One (1) Contactor - Indicator Light Open/Close

BYPASS GUIDANCE

Plan View
Left Hand of FlowPlan View

Right Hand of Flow image1.png image2.png image3.png