N3904022RC20017 RFQ.pdf
PDF 182 KB Posted
- Attached to
- Rental of Diesel-Powered Portable Generator
- Solicitation number
- N3904022RC20017
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR QUOTATION
N3904022RC20017
N39040-17-T-
Please Provide FOB Destination Pricing Page 1 of 7
THIS IS NOT AN ORDER
PLEASE PROVIDE DELIVERED PRICES, AVAILABILITY, AND PRICE SOURCE WITH QUOTE
REFERENCE # N3904022RC20017 DUE DATE: 9/28/2021 12:00 PM ET
From: Portsmouth Naval Shipyard Your company info:
tana.anderson@navy.mil Name:
Contracting, Code 410.2 POC:
Portsmouth, NH 03801-2590 (P)
PHONE: 207-994-0448 (F)
FAX: 207-438-4193 Cage Code:
BUSINESS SIZE: SMALL LARGE PAYMENT TERMS ______%______DAYS
MOBILIZATION TIME: _________ARO PRICES DERIVED FROM ( CHECK ONE )
F.O.B. DESTINATION, Y____N____ ___COMMERCIAL PRICE LIST DATED
IF NO, SHIPPING COST__________. ___INTERNAL PRICE LIST DATED
___OTHER ( PLEASE EXPLAIN )
Please indicate your preferred payment method by checking one of the options below. Payment options available are WAWF and GCPC: Government Commercial Purchase Card (up to $100,000). Please ensure that you register for WAWF (www.wawftraining.com) GCPC_____ WAWF (Wide Area Workflow) _____
*Please note that purchase card orders are not paid up front. Once material is received, a Government cardholder may be contacted for purchase card information.
_X__ If checked, to be awarded on an “All or None” basis, and PPIRS evaluation procedures apply.
YOUR SIGNATURE___________________________________DATE________________________
ITEM DESCRIPTION QTY Total
0001 Trailer mounted Diesel-Powered Portable Generator 6 weeks with a built in fuel tank. In accordance to the SOW below.
0002 Freight to and from Naval Base PT Loma San Diego CA 1 unit 1001 Option 1 1 week
Period of Performance is: 10/14/2021-11/24/2021. Option 1 11/25/2021 – 12/01/2021
Requested start date is 10/14/2021.
Place of performance is: Naval Base Point Loma (NBPL), San Diego, CA.
Security Requirements: Security Plan will be required.
For evaluation purposes, please provide any applicable procedures and technical information. If no information is provided, your quotation may be determined to be unresponsive.
PPIRS/CPARS information will be utilized to evaluate Past Performance.
Award may be made on the lowest price technically acceptable.
Please provide published commercial labor rates and breakdown of total prices, if applicable, for Price Justification purposes.
N39040-17-T-
Please Provide FOB Destination Pricing Page 2 of 7
No deviations without Tech Code authorization. Tech Review Required.
A Diesel-Powered Portable Generator with a built-in fuel tank, a separate Isolation Transformer, Interconnecting cabling from Generator to Transformer, Interconnecting cabling from Transformer to Shipyard provided “Viking Stand”, and one each Berm Containment. All equipment to be located in Point Loma, San Diego CA.
Duration:
o The generator shall be capable of running for a minimum of twelve (12) hours in duration at minimum of 830 kW (910 kVA) PRIME power. STANDBY power shall be a minimum of 1000 kW (1250 kVA). Must be capable of refueling while in operation.
o For pricing purposes, the generator should assumed to be secured unless of loss of power, or the threat of loss of power.
o Delivery and return shipping shall be on a normal weekday (i.e. not a Saturday nor Sunday).
Electrical Output:
o Output shall be ungrounded (commonly referred as ‘floating the ground’ or ‘isolating the neutral’) three-phase power. Vendor shall remove the “Center Tapped” Neutral/Ground (if installed) on the Generator output windings.
o Insulation Resistance of the Generator Windings to Ground must exceed Five (5) Megaohms; provide isolation transformer to achieve required Insulation Resistance.
o Output voltage must be variable between 450 and 480 VAC at 60 Hz, while maintaining the rated power levels. The maximum STANDBY amperage will be approximately 1600A (@ 450V, 1000 kW and a 0.8PF). Therefore, the generator’s breaker should be set to trip on long-time delay at between 1770 and 1880A. In addition, the instantaneous trips should be HIGH to allow for in-rush currents.
o The PRIME power output shall be a minimum of 830 kW over a 1.0 to 0.8 PF range lagging (910 kVA at 0.8 PF).
o The insulation rating of the generator windings to ground must exceed five (5) Mega ohms.
o Diesel Generator MUST have at least one 120 VAC, 15 Amps, single- phase power receptacle available for string lighting when the diesel is (or, is not) running, or have internal lights sufficient to illuminate the controls when the diesel is (and is not) running.
The 120 VAC power can be grounded or ungrounded (grounded is preferred).
o Diesel Generator frame MUST be grounded.
o The Isolation Transformer shall have at least 1400 KVA capability. provided.
Connections:
o Lugged connections are acceptable as well as compression fittings (Lugs are preferred).
o When lugs are used, Unit must accept Thomas and Betts 600 Green 94 lugs, or when lugs are not used SHOF-500 cables will terminate in compression fittings.
o 150 Feet each, of 4/0 Camlock Cables. Total of (12) Twelve cables from the Generator to the Isolation Transformer.
o (12) Twelve each Type W 500 MCM 25 ft cables to connect Viking stand to transformer.
Viking Stand utilizes 500 MCM Duraline connectors.
Service:
o Except for daily surveillance checks (i.e. liquid levels and refueling), the Contractor is responsible for and shall perform all maintenance (e.g. refrigerant charge, oil changes, N39040-17-T-
Please Provide FOB Destination Pricing Page 3 of 7 replace / clean filters, lubrication, coolant refills, liquid top-offs, etc.) for the duration of the lease.
o Coordinate maintenance with the executing point of contact (POC). Maintenance will be performed at shutdown periods that are convenient for the sub base.
o If there is an issue with the generator, the vendor shall respond within four (4) hours of initial notification of the need for repair. In that time the Contractor shall have a knowledgeable and equipped technician on the job-site fully prepared to repair the rental equipment. The defective unit shall be repaired within eight (8) hours of initial notification or, if the original defective unit(s) cannot be made operational, replaced within sixteen (16) hours of initial notification. If the equipment failure is not the fault of the Government, the Contractor shall bear all costs associated with its repair and/or replacement.
Delivery Inspection/Requirements:
o Upon delivery, the vendor shall prove that the 450-480 VAC power is ungrounded.
o Upon delivery, the vendor shall provide operating instructions for the diesel generator.
o Upon delivery, the vendor shall instruct designated shipyard personnel on how to properly run the equipment to include its operation, control, daily checks, and service contacts.
o Upon delivery, the Vendor shall provide recent documentation of a SAT full load test for a duration of, at least 1 hour. Full load shall be 830 kW / 910 kVA. Load test shall be within 2 weeks, prior to delivery.
o Upon delivery, and at customer’s discretion; the generator may immediately be started and a load of 830 kW / 910 kVA applied for duration of one full hour. A unit that cannot sustain the load will be rejected.
Footprint:
o The generator package will be deployed pier side to provide backup power to a submarine.
o The platform that the generator will be placed on is space limited. The generator enclosure needs to fit in a standard CONEX box that is twenty (20) feet long (or less) with the external fuel tank extending no more than eight (8) feet from the generator box.
o The overall width shall not be greater than eight (8) feet.
Trailer:
o The trailer shall be of recent vintage, and be capable of being moved by tractor or mule.
o If the diesel is equipped with an auxiliary fuel tank, the tank shall fit entirely onto the trailer with the conex box.
Lifting & Handling:
o The generator will be capable of being lifted by crane (a four-point lift).
o A Lifting & Handling diagram/sketch that is applicable to the trailer situation shall be provided.
Fuel:
o The generator shall be delivered with the quantity of fuel sufficient to run for at least eight (12) hours in duration at a load of 830 kW (910 kVA).
o The generator engine shall be diesel-powered.
Noise:
o When operating at full speed, noise levels must not be over 85 dB [A] at three (3) feet from the unit.
CONSTRUCTION:
N39040-17-T-
Please Provide FOB Destination Pricing Page 4 of 7 o Units shall be a single integrated framed structure manufactured as a complete entity to include all devices, accessories, and fittings necessary to perform the function for which it was designed.
o Construction shall be NEMA 3R (or greater) with self-contained temperature control system that is appropriate for a seaside environment.
o Machines shall meet State and Federal requirements for its type such as the National Electrical Code (NEC) for electrical devices / components.
o The generator must be certified for use in the State of California and be marked as such on the generator.
o Machines shall be newly manufactured / completely refurbished and factory tested within ten (10) years.
o Machines shall be Nationally Recognized Testing Laboratory (NRTL) approved.
o The diesel generator shall be equipped with a self-contained cooling system.
Environment o The generator shall meet all of the emission standards of the Environmental Protection
Agency (EPA).
o The generator must meet all emission requirements for use in the State of California.
o An Environmental Berm for placement on the pier shall be provided by the vendor for the
Diesel\Trailer.
N39040-17-T-
Please Provide FOB Destination Pricing Page 5 of 7
CLAUSES:
Responsibility and Inspection: unless otherwise specified in the order, the supplier is responsible for the performance of all inspection requirements and quality control. The following FAR provisions and clauses are applicable to this procurement:
52.203-19 Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements 52.204-7 System for Award Management 52.204-10 Reporting Executive Compensation and First-Tier Subcontract Awards 52.204-13 System for Award Management Maintenance 52.204-16 Commercial and Government Entity Code Reporting 52.204-18 Commercial and Government Entity Code Maintenance 52.204-19 Incorporation by Reference of Representations and Certifications.
52.204-22 Alternative Line Item Proposal 52.204-23 Prohibition on Contracting for Hardware, Software, and Services Developed or Provided by Kaspersky 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment.
52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance
Services or Equipment.
52.209-6 Protecting the Government's Interest When Subcontracting With Contractors Debarred 52.209-10 Prohibition on Contracting With Inverted Domestic Corporations 52.211-14 Notice Of Priority Rating For National Defense, Emergency Preparedness, and Energy
Program Use 52.211-15 Defense Priority and Allocation Requirements 52.212-1 Instructions to Offerors--Commercial Items 52.212-2 Evaluation - Commercial Item 52.212-3 Alt 1 Offeror Representations and Certifications--Commercial Items 52.212-4 Contract Terms and Conditions--Commercial Items 52.215-5 Facsimile Proposals 52.217-5 Evaluation of Options 52.217-9 Option to Extend the Term of the Contract 52.219-6 Notice of Total Small Business Set-Aside 52.222-50 Combating Trafficking in Persons 52.223-6 Drug-Free Workplace 52.223-18 Encouraging Contractor Policies To Ban Text Messaging While Driving 52.225-25 Prohibition on Contracting with Entities Engaging in Certain Activities or Transactions 52.232-25 Prompt Payment 52.232-33 Payment by Electronic Funds Transfer--System for Award Management 52.232-36 Payment by Third Party 52.232-39 Unenforceability of Unauthorized Obligations 52.232-40 Providing Accelerated Payments to Small Business Subcontractors 52.233-3 Protest After Award 52.233-4 Applicable Law for Breach of Contract Claim 52.243-1 Changes—Fixed Price 52.246-2 Inspection of Supplies—Fixed Price 52.247-34 F.O.B. Destination
52.249.1 Termination for Convenience of the Government (Fixed-Price) (Short Form) 52.252-1 Solicitation Provisions Incorporated By Reference 52.252-2 Clauses Incorporated By Reference
N39040-17-T-
Please Provide FOB Destination Pricing Page 6 of 7
52.252-5 Authorized Deviations in Provisions 52.252-6 Authorized Deviations in Clauses
All clauses shall be incorporated by reference in the order. Additional DFARS contract terms and conditions applicable to this procurement are:
252.203-7000 Requirements Relating to Compensation of Former DoD Officials 252.203-7002 Requirement to Inform Employees of Whistleblower Rights 252.203-7005 Representation Relating to Compensation of Former DoD Officials 252.204-7003 Control Of Government Personnel Work Product 252.204-7006 Billing Instructions 252.204-7007 Alternate A, Annual Representations and Certifications 252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support 252.204-7019 Notice of NIST SP 800-171 DoD Assessment Requirements.
252.204-7020 NIST SP 800-171 DoD Assessment Requirements.
252.211-7000 Notice to Prospective Suppliers on Use of Supplier Performance Risk System in Past
Performance Evaluations 252.213-7000 Notice to Prospective Suppliers on Use of Past Performance Information Retrieval
System 252.215-7013 Supplies and Services Provided by Nontraditional Defense Contractors.
252.225-7048 Export-Controlled Items 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports 252.232-7006 Wide Area WorkFlow Payment Instructions 252.232-7010 Levies on Contract Payments 252.244-7000 Subcontracts for Commercial Items 252.246-7008 Sources of Electronic Parts 252.247-7023 Transportation of Supplies by Sea
C-202-H001 ADDITIONAL DEFINITIONS--BASIC (NAVSEA) (OCT 2018)
C-204-H001 USE OF NAVY SUPPORT CONTRACTORS FOR OFFICIAL CONTRACT FILES
(OCT 2018)
C-211-H018 APPROVAL BY THE GOVERNMENT (NAVSEA) (JAN 2019)
C-211-W001 REPLACEMENT PARTS AVAILABILITY (NAVSEA) (OCT 2018)
C-247-H001 PERMITS AND RESPONSIBILITIES (NAVSEA) (DEC 2018)
D-247-H002 PACKAGING OF SUPPLIES—BASIC (NAVSEA) (OCT 2018)
D-247-W001 PROHIBITED PACKING MATERIALS (NAVSEA) (OCT 2018)
E-246-H016 INSPECTION AND ACCEPTANCE OF F.O.B. DESTINATION DELIVERIES (OCT
2018)
F-242-H001 CONTRACTOR NOTICE REGARDING LATE DELIVERY
G-232-H002 PAYMENT INSTRUCTIONS AND CONTRACT TYPE SUMMARY FOR PAYMENT
OFFICE (NAVSEA) (JUN 2018)
G-232-H004 GOVERNMENT PURCHASE CARD METHOD OF PAY (NAVSEA) (OCT 2018)
G-232-H005 SUPPLEMENTAL INSTRUCTIONS REGARDING INVOICING (NAVSEA) (JAN
2019)
G-242-H001 GOVERNMENT CONTRACT ADMINISTRATION POINTS-OF-CONTACT AND
RESPONSIBILITIES (NAVSEA) (OCT 2018)
G-242-H002 HOURS OF OPERATION AND HOLIDAY SCHEDULE (NAVSEA) (OCT 2018)
L-204-H003 NOTIFICATION OF USE OF NAVY SUPPORT CONTRACTOR FOR OFFICIAL
CONTRACT FILES (NAVSEA) (APR 2019)
M-247-H001 F.O.B. EVALUATION CRITERIA (NAVSEA) (DEC 2018)
N39040-17-T-
Please Provide FOB Destination Pricing Page 7 of 7
52.212-2, Evaluation - Commercial Items is applicable to this procurement.
The Government will award a contract resulting from this solicitation to the responsible vendor whose quote conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The contract will be awarded to the vendor with the Lowest Price Technically Acceptable.
Quotes will be evaluated based on the following criteria:
-Technical
Must meet specifications and documents capabilities to include, Adherence to Schedule (Award may be made based on delivery and ability to meet the requested schedule)
- Price
Lowest Price Technically Acceptable, after adherence to other factors
Vendors will be required to submit a quote that will be evaluated in accordance with the specifications provided in the solicitation, FAR 52.212-1 Instruction to Offerors. Failure to include pricing for all line items shall be cause for rejection of the quote for all line items.
Technical:
Please provide
Documentation demonstrating your capabilities in fulfilling the SOW.
Documentation demonstrating or stating your ability to adhere to the provided schedule.
Technical Evaluation Ratings Rating Description Acceptable Submission clearly meets the minimum requirements of the solicitation
Unacceptable Submission does not clearly meet the minimum requirements of the solicitation
If the technical submittal is determined “Unacceptable”, it renders the entire quote technically unacceptable. Technical submissions that do not meet the minimum requirements will be rated as “Unacceptable” and will no longer be considered for further competition or award.
Price:
The Price will be evaluated as Lowest Price Technically Acceptable, however, the Contracting Officer reserves the right to award based on ability to meet the required schedule.
File details come from the government source that posted it. Updated .