Attachment 4 Q&A.pdf
PDF 55 KB Posted
- Solicitation number
- N3904020R0001-0003
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment #4 Questions and answers
1. The Riser Cu is specified as C107 Oxygen Free. C107 is made by one particular Cu Mill /
Commutator Manufacturer and is unattainable to other manufacturers. Can C101 Oxy
Free material for the risers be used instead?
A. We can’t deviate on material. The higher level documents (SUBMEPP
Maintenance Standards) clearly define the material requirements
File details come from the government source that posted it. Updated .