LPAC SPECIFICATION GUIDELINES

400 CFM Low Pressure, Oil-Free Air Compressor, I 00 HP motor, 120 PSI , 225 Amp, 460 V AC, 3 Phase, with after cooler/ inter cooler, refrigerant type air dryer. Including a 150 cubic foot air receiver with safety valves, hoses and fittings to connect to the unit. Upon delivery, contractor is required to make all hose connections between compressor, dryer, and air receiver, and all hose connections must have safety cables installed to prevent hose whip in case of accidental separation of coupling or clamp device .

Equipment is to be provided with spare parts and air filters . The compressor/dryer assembly shall be a complete operating unit. It shall deliver I 00% oil free air, and be equipped with an integral after cooler and a high temperature shutoff/alarm. It shall be air-cooled and enclosed in a weatherproof enclosure suitable for outdoor operation in 0 degree Fahrenheit (F) temperatures without the need for additional shelter/protection. The air dryer shall provide a pressure dew point of 34 to 38 degrees F at I atmosphere and be sized to be compatible with the system air compressor. The LPAC shall come with a 250 gallon Air ASME rated at 125 psig minimum.

The equipment shall be delivered in a first class operating condition with complete operating instructions. The unit(s) shall be wired electrically to enable a single point shipyard connection and equipped with 50 feet of cable to enable this connection.

The system shall be mounted on a four (4) wheeled platform/trailer. The platform/trailer shall be equipped with a hitch for ease of movement short distances by a small two-wheel drive vehicle .

The contractor shall maintain a stringent maintenance program and be responsible for all routine maintenance, except for daily check of liquid levels. The contractor shall provide oil , filters , coolant, and lubricant for engine and compressor operation during the rental period.

The contractor shall provide service within twelve ( 12) hours after notification by the Contracting Officer or his/her representative. In the event the machine cannot be returned to service within twenty-four

(24) hours of notification, a replacement shall be delivered at no extra charge to the Government.

The contractor shall be responsible for equipment failure not ari sing out of abuse or negligence by the government.

There shall be no changes unless authorized by the Contracting Officer.

Point of Contact & Phone Number of person responsible for service:

Deliver to :

Point of Contact and Phone Number will be provided when contract is awarded.

ALL CONTRACTOR PERSONNEL REQUIRING ACCES TO A GOVERNMENT FACILITY MUST

BE AMERICAN CITIZENS AND SHALL PROVIDE PROOF OF SUCH BEFORE ACCESS IS

ALLOWED. ALLOW TIME FOR SECURITY CHECKS.