This is a Performance Work Statement (PWS) for the inspection and opening of AS-39 turbines for the Department of the Navy Military Sealift Command. The PWS outlines the technical and administrative requirements for Original Equipment Manufacturer (OEM) services related to AS-39 turbine maintenance and inspection activities. The work encompasses comprehensive opening, inspection, and assessment procedures to ensure turbine operability and compliance with naval specifications. The statement establishes performance standards, quality assurance requirements, and documentation protocols that the contractor must follow throughout the inspection process, including detailed reporting of findings and condition assessments of turbine components.
The PWS specifies contractor responsibilities for executing inspections in accordance with OEM technical manuals and Navy-approved procedures, including preparation of inspection reports with photographic documentation and recommendations for repair or replacement of identified defects. The contractor must maintain compliance with all applicable naval safety standards and quality control measures throughout the work scope, with particular emphasis on detailed component-level analysis and accurate technical documentation to support maintenance and operational decision-making by Military Sealift Command personnel.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N3220527Q7045 Other than Full and Open.pdf | ||
| Solicitation - N3220527Q7045.pdf | ||
| 15-4341.txt | TXT text file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USS LAND and USS CABLE
( AS 39 Class )
| PROPULSION/GENERATION MACHINERY |
| CONTRACT NO. N00000-00-X-0000 |
| ITEM NO. XXXX |
| CATEGORY "A" |
| 2026-08-06 |
| AS-39 TURBINES OPEN AND INSPECT |
| Pete DeSimone |
1. ABSTRACT
1.1. This item describes the requirements to open and inspect the HP Turbine, LP turbine, and SSTGs for refurbishment consideration as future AS Class spares.
2. REFERENCES/ENCLOSURES
2.1. References:
2.1.1. Technical Manual 0341-LP-138-3000, Main Propulsion Steam Turbines and Gears
2.1.2. NAVSEA Tech Manual 0961-LP-071-014, Ship Service Generator
2.2. Enclosures:
2.2.1. Photos of Units
3. ITEM LOCATION/DESCRIPTION
3.1. Location/Quantity
3.1.1. Quantity: One (1) Main Propulsion HP Turbine Assembly
3.1.2. Quantity: One (1) Main Propulsion LP Turbine Assembly
3.1.3. Quantity: Four (4) SSTG Turbine Assemblies
3.2. Item Description/Manufacturer’s Data:
3.2.1. HP Turbine Description (QTY 1)
| APL: | 051150034 |
| Serial Number: | 654259 |
| Mfr: | SIEMENS DEMAG DELAVAL |
| Mfr Dwg: | H2729ASSYH2730 |
| Type: | HIM |
| EQUIP SPEC: | MILT17600 |
| Design Speed: | 6,126 RPM |
| No. Stages: | 9 |
| Operating Steam Pressure: | 600 PSIG |
| Operating Steam Temperature | 850 Deg F |
| Weight of HP Rotor: | 1,855 lbs |
| Bearing Span: | 66-1/2” |
| Rotor LOA: | 78-1/2” |
| Maximum Rotor Diameter: | 23.455” |
| Weight of Upper Casing Half: | 5,650 lbs |
3.2.2. LP Turbine Description (QTY 1)
| APL: | 051150035 |
| Mfr: | SIEMENS DEMAG DELAVAL |
| Mfr Dwg: | H2729 & H2731 |
| Type: | HIM |
| EQUIP SPEC: | MILT17600 |
| Design Speed: | 5,322 RPM |
| No. Stages: | 6 Single Flow & 2 Astern |
| Operating Steam Pressure: | 600 PSIG |
| Operating Steam Temperature | 850 Deg F |
| Weight of LP Rotor: | 5,650 lbs |
| Bearing Span: | 76” |
| Rotor LOA: | 90-1/4” |
| Maximum Rotor Diameter: | 45-1/2” |
| Weight of Upper Casing Half: | 8,400 lbs |
3.2.3 SSTG Turbine Description (QTY 4)
| Mfr: DeLaval |
| Type: GJ |
| Speed: 8929 RPM |
| Steam Pressure: 570 PSIG |
| Steam Temperature: 850 Deg F. |
| Exhaust Pressure: 4 HgA |
| Overspeed Trip Speed: 9,825-10,000 RPM |
| Nr Turbine Rotor Wheels: 8 Rows |
| Bearing Span: 51-1/4” |
| Rotor Dimension: Approx 26” Dia. x 72” L |
| Rotor Weight: 1,003 lbs |
| Turbine Upper Case with Diaphragms Weight: 2,245 lbs |
4. GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES: None
5. NOTES:
5.1. MSC REP is Peter DeSimone, 757-434-2772, peter.c.desimone2.civ@us.navy.mil
6. QUALITY ASSURANCE REQUIREMENTS: None additional.
7. STATEMENT OF WORK
7.1. The contractor shall provide crane and rigging support to transfer the turbines between government transportation and the contractor’s shop.
7.2. Turbine Assemblies listed in paragraph 3.0 (HP, LP, and SSTGs):
7.2.1. Disassemble the turbines to remove the rotors and diaphragms for inspection. Conduct inspection of the rotors and diaphragms and provide a CFR outlining the results of the inspection and a recommendation if the equipment can be serviced to fit-for-service condition. For bidding purposes assume the inspections shall include fly ash blast, wet MP NDT and close visual inspection of the rotors and diaphragms.
7.2.2. Remove and inspect SSTG Reduction Gears and provide recommendation for servicing to return to a fit-for-service condition.
7.2.3. Recommend any additional candidate parts for inspection and candidate refurbishment to include the nozzle block. Additional parts will be considered as a Change Order.
7.2.4. Dispose of remaining turbine parts (e.g. casings, coolers, frames, etc)
7.2.5. Refurbishment of components will be addressed by a Change Order or a separate Purchase Order.
7.3. Generators:
7.3.1 Remove the generators from each SSTG and crate for Government pick up.
7.3.2 Government will pick up generators within 14 calendar days of notice.
7.3.3 Provide crate cube and weights for each of the generator crates. Label each crate as follows:
Requisition No. (To be provided by MSCREP) Generator, Ships Service Turbine Quantity 1 Gross weight and container volume (cube)
7.3.4 Provide crane and rigging to load crate on Government transport.
7.4. Manufacturer’s Representative:
7.4.1. Contractor shall provide the on-site services of the OEM or an MSC N7 approved non-OEM to complete all work on the turbines. The OEM and MSC N7 approved turbine companies are listed below.
Curtis Wright 1101 Cavalier Blvd Chesapeake, Virginia 23323 POC: Bryan Murphy Phone: (757) 592-0973 E-mail: bryan.murphy@siemensgovt.com MI-Tech Inc.
6685 Jet Park Road North Charleston, SC 29406 POC: Bill Totten Phone: (843) 553-2743 E-mail: bill@mi-tech.net PJ Schwalbenberg & Associates Inc 26 Spear Mill Road Cushing, Maine 04563 POC: Pete Schwalbenberg Phone: (207) 354-0700 E-mail: office@turbinesandgears.comTurboGen
8. GENERAL REQUIREMENTS – None Additional.
Enclosure 2.1 – Main Engine High Pressure Turbine
Enclosure 2.2 – Main Engine Low Pressure Turbine
SSTG
0286 - 9 image1.jpeg image2.jpeg image3.jpeg image4.jpeg image5.jpeg image6.jpeg