SOW.docx

DOCX document 39 KB Posted

Attached to
USNS YUKON MHE RECERT Federal contract opportunity
Solicitation number
N3220520Q0175
Issued by
Department of the Navy Military Sealift Command

View the file

Other files for this federal contract opportunity

Other files attached to USNS YUKON MHE RECERT, newest first.
File Type Posted
TECHNICAL EXHIBIT _ Safety Certification.docx DOCX document
TECHNICAL EXHIBIT _ Electric Forklift.docx DOCX document
TECHNICAL EXHIBIT _ Diesel Forklift.docx DOCX document
WD PORTLAND OR.pdf PDF
TECHNICAL EXHIBIT _ Aerial Work Platforms _ AWP.DOCX DOCX document
SYNSOL.docx DOCX document
TECHNICAL EXHIBIT _ Aerial Work Platform Certification Form.doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR QUOTE (RFQ)

Date: 30 DEC 2019 (REVISED)

To: -OPEN BID-

From:Military Sealift Command (MSC)
Bldg. SP-64, 471 "C" Street, Norfolk VA 23511
Jason L. McLaughlin
Supervisory Contract Officer, N10
757-416-2453

Subject: MATERIAL HANDLING EQUIPMENT (MHE) RECERTIFICATION SERVICE REQUEST IN SUPPORT OF USNS YUKON

Reference: (a). NAVSEA SW0-23-AH-WHM-10 Eight Revision, Handling Ammunition and Explosives with industrial Material Handling Equipment (MHE) (b). NAVSUP Publication 538 Sixth Revision, Management of Material Handling Equipment (MHE) and Shipboard Mobile Support Equipment (SMSE)

Attachments:(1). Technical Exhibit - Safety Certification Requirements
(2). Technical Exhibit - Maintenance Service Requirements; Electric Forklift
(3). Technical Exhibit - Maintenance Service Requirements; Diesel Forklift
(4). Technical Exhibit - Maintenance Service Requirements; AWP

(5). Technical Exhibit - Aerial Work Platform (AWP) Safety Certification Form

1. Purpose: In accordance with ref (a) and (b), a quote is requested to provide Material Handling Equipment (MHE) service and support to include an open/inspection, repairs, services, and/or materials. The following information and requirements are hereby provided for planning and pricing purposes. Submission of “Price & Availability Feedback” does not constitute a guarantee of purchase, service contract, or delivery order.

2. Activity/Vessel: USNS YUKON (T-AO 202)

3. Location of Equipment/Services: PORTLAND, OR. (C3F AOR)

4. Period of Performance (POP): 11 FEB 2020 to 01 APR 2020

5. SOR: N2186993304001

6. Statement of Work (SOW): The following work items shall be accomplished by the selected service provider (contractor) in conjunction with this repair and maintenance requirement. The Government intends to award a Fixed Price Contract to the selected service provider:

a. MSC’s preferred location of services to MHE identified in Tables 1 and 3 (below), is onboard the customer activity vessel, OR, ashore at the Contractor’s maintenance facility as an acceptable alternate location. If performing services ashore, the service provider SHALL coordinate and arrange transportation of the MHE assets to/from the contractor’s facility. Shipping cost will be included with CLIN 0001. The Contractor’s quote shall specify the proposed location of the service and provide a summary of the proposed process for maintenance, repairs, and safety recertification.

b. Contractor shall perform all related inspections (incl. fork/tines), maintenance, repair, testing and certification of MHE identified in Table 1 in accordance with the requirements set forth in references (a) and (b), attachments 1 through 5 (technical exhibits), and appropriate vehicle technical manuals.

c. Contractor shall perform an operational check on all forklift batteries installed in MHE identified in Table 1. Contractor shall provide a condition report on batteries including all recommended repair/replacement actions.

d. Contractor shall perform an operational check on all battery chargers listed in Table 2 to ensure proper operation, voltage, and amperage settings. Contractor shall reset battery chargers in accordance with the specifications provided in the battery charger technical manuals and per direction from the ship’s Chief Engineer.

e. Contractor shall perform basic corrosion control (incl. spot painting, as needed) and proper marking/stenciling on all MHE identified in Tables 1 and 3. The contractor shall utilize appropriate wire brush and spot painting techniques. Approved spot paint includes brand types: Enamel Gray Primer (V2182838), Black Rust Reformer (215634), Equipment Yellow Paint (V2148838), and Gloss Black paint (V2179838), or equivalent. If full painting is determined to be required, contractor shall include a quote for this service as directed in the deliverables section, below.

f. Contractor shall remove, and inspect the counterweight, mounting bolt, and the base plate threads for wear on all shipboard diesel forklifts to include removing the bolt, and counter weights for inspection of rust, corrosion, and worn threads on the bolts, and threaded base plate surface. Contractor shall reinstall the counterweight, and mounting bolts that are within SAE standards, and re-torque the counterweight bolts to 410 foot pounds, or replace the bolts, and rethread the base plates that fail the visual inspection, as required.

g. Contractor shall perform a test of all rear brake systems on standard HYSTER forklifts listed in Table 1 by lifting the rear axle off the ground, applying the brakes and testing the brake operation. Proper operation of the rear master cylinder and wheel cylinders will be verified. Master cylinder and brake drums shall be adjusted to ensure appropriate rotational resistance of the rear wheel with brake pressure applied.

h. Contractor shall provide a condition report on each unit identified in Tables 1 and 3. All condition reports shall contain, at the minimum, the ship's name, the MSC MHE serial number, manufacture identification number, make and model, a complete list of recommended repairs and services, and all associated pricing information.

i. Contractor shall perform a periodic maintenance service on the aerial work platform (AWP) identified in Table 3 in accordance with manufacturer recommendations. Attachments 4 and 5 (technical exhibits) are provided for reference and usage as well.

j. Contractor shall complete a safety certification and weight test on the aerial work platform (AWP) listed in Table 3 in accordance with the requirements set forth in reference (b). Refer to NAVSUP P-538, 6th edition, para 8-7.6 and figure 8-16.

7. Equipment to be serviced:

USNS YUKON - TABLE 1

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE/SAFETY
HYSTER
E40ZG
2302312
G108N10671F
STD ELEC
HYSTER
E40ZG
2302313
G108N10770F
STD ELEC
HYSTER
E40ZG
2302314
G108N10777F
STD ELEC
HYSTER
S60FTG
2302135
F187G11813F
STD DIES
HYSTER
S60FTG
2302381
F187G14573G
STD DIES
HYSTER
S60FTG
2302382
F187G14574G
STD DIES

USNS YUKON - TABLE 2

MANUFACTURER
SERIAL NO.
MODEL
NOMINAL OUTPUT CHARACTERISTICS

B F SYSTEMS INC

8894-19
8826
CHGRBATT440VAC IN 42.3VDC 200AMP MAX OTP
8891-21
8826
CHGRBATT440VAC IN 42.3VDC 200AMP MAX OTP
8894-20
8826
CHGRBATT440VAC IN 42.3VDC 200AMP MAX OTP
8894-18
8826
CHGRBATT440VAC IN 42.3VDC 200AMP MAX OTP

USNS YUKON - TABLE 3

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE
JLG
460SJ

25-00016

0300-120407
BOOM, ARM LIFT

8. Deliverables:

The Contractor shall provide:

(1). A condition report for all units listed in Tables 1 and 3 to the MHE Program Support Office at MSC Norfolk (N44) within 5 days of receipt of MHE. A copy of the condition reports will be provided to the ship’s Master or his designated representative upon request.

(2). A quote for additional repairs and services beyond the scope of the initial contract award. The quote will be provided to the Norfolk points of contact (listed below) within 10 days of receipt of MHE.

(3). Final condition reports containing all remaining additional work requirements to the MHE Program Management Office no later than 15 days prior to the end of the scheduled Period of Performance (POP) listed in paragraph 4, above.

(4). A complete and signed MHE Safety Certification form for each unit listed in Tables 1 and 3. The original signed forms shall be provided to the ship's Master or his designated representative.

(5). A complete and signed Fork Inspection form for each unit listed in Table 1. The original signed forms shall be provided to the ship's Master or his designated representative.

(6). Safety Certification markings/labeling stenciled or affixed to each unit listed in Tables 1 and 3.

(7). A condition report on all batteries installed in electric and diesel forklifts, and, in addition, a condition report for all shipboard MHE battery chargers (as required).

(8). Contractor shall coordinate with the shipboard technical point of contact to arrange U.S. Government inspection of the MHE/forklifts prior to their return. The inspection will occur on a date mutually agreed upon by the service provider and the shipboard technical point of contact.

(9). A copy of all condition reports, certification paperwork and inspection forms to the Norfolk technical points of contact listed below.

9. Qualifications. The selected service provider/contractor must meet the following qualifications:

a. All management and technical personnel performing above listed services must be able to demonstrate the following:

- Experience performing safety certifications on shipboard-approved MHE in accordance with the requirements set forth in the NAVSEA SW023-AH-WHM-010, NAVSUP PUB 538, and equipment technical manuals.

- Experience interpreting, trouble-shooting, and resetting HYSTER on-board dash displays.

- Access to HYSTER proprietary hardware and software required to reset on-board MHE electronics.

b. Contractor personnel performing repairs and maintenance onboard MSC vessels or activities shall abide by all DOD, Navy, MSC security requirements and clearance procedures required to access U.S. Government facilities and/or MSC vessels.

c. Proof of U.S. citizenship shall be provided in order to enter a U.S. military facility, if requested by the Government. When accessing a U.S. Government installation, proposed contractor personnel shall be vetted by the Government through the Government's El Paso Intelligence Center (EPIC) before accessing the Government activity location.

d. The contractor must be able to perform the required services within the Period of Performance (POP) identified in the RFQ/Statement of Work document. If additional work is identified, and approved by the Government, the Contractor must have the ability to complete the additional work by the close of the period of performance as well.

10. MSC NORFOLK - Technical Points of Contact (POCs):

- PRIMARY POC:

Russell Byrnes Office: (757) 341-2309 Email: Russell.Byrnes.ctr@navy.mil

- ALTERNATE POC:

Robert M. Hall Office: (757) 443-2482 Email: Robert.m.hall1.ctr@navy.mil

11. Shipboard - Technical Points of Contact (POCs):

YUKON - Chief Engineer (CHENG):
Roger Guillaume
Email: roger.guillaume.civ@yukon.navy.mil (and/or)
cheng@yukon.navy.mil
Ship phone: 850-549-0222 / -0224
YUKON - Principal Port Engineer (PPE):
Mark Cyr

Email: mark.a.cyr@navy.mil Office/Cell: 757-443-0920 / 757-287-4025

YUKON - Supply Officer (SUPPO):
Rodrigo Gonzales
Email: Rodrigo.p.gonzales.civ@yukon.navy.mil

Ship phone: 850-549-0223

12. RFQ Submittal: In response to the above information and statement of work or work item, the contractor is afforded the opportunity to submit a quote (consistent with applicable contract rates) and total pricing to provide the aforementioned service(s) or materials.

a. Contractor shall ensure their designated representatives can access the specified Government activity, shipyard, and/or vessel prior to submitting a quotation.

b. Quotes shall be provided on company letterhead and reference the applicable RFQ number (provided above).

c. Quotes shall be provided to the following MSC contracting officer (KO), via email:

Jason L. McLaughlin Military Sealift Command Contract Specialist, N10 471 "C" Street, Bldg. SP-64 Norfolk, VA 23511 Phone: 757-416-2453 E-mail: jason.mclaughlin2@navy.mil

File details come from the government source that posted it. Updated .