0118_A_PUMP_ROOM_LADDER_FABRICATE_AND_INSTALL_(TALT_098).docx

DOCX document 140 KB Posted

Attached to
USNS TRENTON Aluminum Weld Inspection Support
Solicitation number
N3220519Q4724
Issued by

About this file

WI 0118

View the file

Other files

File Type Posted
0105_A_SEWAGE_TANK_INSPECTION_AND_COATING.docx DOCX document
PWS_Aluminum_Weld_Support_8-02-2019_Rev_C.docx DOCX document
0102_A_MISSION_BAY_CBG_PANEL_AND_SCUPPER_INSPECTIONS.docx DOCX document
0121_B_LOWER_FOREPEAK_INSPECTION_AND_REPAIRS_Rev1.docx DOCX document
0101_A_STRUCTURAL_INSPECTIONS.docx DOCX document
0109_A_TOW_MODIFICATION_(TALT_026)_Rev1.docx DOCX document
N3220519Q4724_USNS_TRENTON_Weld_Inspector.docx DOCX document
0120_B_STRUCTURAL_REPAIRS_Rev1.docx DOCX document
0119_A_HATCH_REMOVAL_AND_OVERHAUL_Rev1.docx DOCX document
SOW-Aluminum_Mod__Repair_Template_5XXX_Series_Aluminum_FEB_2019_JFV.docx DOCX document
0118_A_PUMP_ROOM_LADDER_FABRICATE_AND_INSTALL_(TALT_098).docx DOCX document
0113_A_INTERNAL_TANK_5th_YEAR_INSPECTIONS.docx DOCX document
0102_A_MISSION_BAY_CBG_PANEL_AND_SCUPPER_INSPECTIONS.docx DOCX document
0105_A_SEWAGE_TANK_INSPECTION_AND_COATING.docx DOCX document
0113_A_INTERNAL_TANK_5th_YEAR_INSPECTIONS.docx DOCX document
N3220519Q4724_USNS_TRENTON_Weld_Inspector.docx DOCX document
0121_B_LOWER_FOREPEAK_INSPECTION_AND_REPAIRS_Rev1.docx DOCX document
PWS_Aluminum_Weld_Support_8-02-2019_Rev_C.docx DOCX document
0120_B_STRUCTURAL_REPAIRS_Rev1.docx DOCX document
0119_A_HATCH_REMOVAL_AND_OVERHAUL_Rev1.docx DOCX document
0101_A_STRUCTURAL_INSPECTIONS.docx DOCX document
0109_A_TOW_MODIFICATION_(TALT_026)_Rev1.docx DOCX document
SOW-Aluminum_Mod__Repair_Template_5XXX_Series_Aluminum_FEB_2019_JFV.docx DOCX document
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USNS TRENTON (T-EPF 5)

HULL AND STRUCTUREN4044420RCN7001
01 April 2019
WORK ITEM NO. 0118Category “A”N7/STAMARIA/WCL

PUMP ROOM LADDER FABRICATE AND INSTALL (TALT 098)

1.0 ABSTRACT

1.1 This item describes the requirement to fabricate and install an aluminum ladder in accordance with reference drawing to be installed on Pump Room 7 and 8.

2.0 REFERENCES/ENCLOSURES:

2.1 1749113 Inclined Ladders, Aluminum Assemblies & Details

2.2 8443364 F General Arrangement

2.3 ENCLOSURE (1) Picture of Space indicating ladder location.

3.0 ITEM LOCATION/DESCRIPTION

3.1 Pump Room 7 and 8, 1-51-1 and 1-51-2

4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICE: None.

5.0 NOTES: None.

6.0 QUALITY ASSURANCE REQUIREMENTS

6.1 The contractor shall perform static weight test of the installed ladder using 300 lbs. test weight placed in each ladder steps. Prior to and after weight test, perform PT testing on weld joints.

6.2 All welding shall be done in accordance with the references and specifications outlined in the 0101 level Structural items in this work package.

7.0 STATEMENT OF WORK REQUIRED

7.1 Furnish services of Marine Chemist to certify spaces for “Safe for Man” and “Safe for Hot work”. Ladder installation is welded to the top of the lube oil tank, with fuel storage forward of the lube oil tank.

7.2 Perform actual measurements on Pump Room 7 and 8 for the location of the ladder to ensure ladder fabrication shall be in accordance with Reference 2.1 to ensure that ladder shall conform with the form, fit and function.

7.3 Contractor shall perform modification on the handrails on the upper platform to be able to install the ladder as indicated on the enclosure (1).

7.4 Contractor shall utilize an ABS certified aluminum welder to perform the ladder fabrication and installation of all appendages onboard. 5083 or 5086 aluminum is suitable for fabrication.

7.5 Using reference 2.1 as guidance, fabricate the ladder using aluminum as material on all components of the ladder including ladder connection lug on the top and bottom of the ladder connection.

7.6 Contractor shall install staples between stanchions located on top and mid-section of the stanchions on the ladder opening on top platform and install stainless steel removable chain. Chain shall serve as a fall protection when ladder is not in use.

7.7 Upon completion of ladder assembly on Pump Room 7 and 8, perform static weight test using 300 lbs. of weights placed on each ladder steps. Hold weights for 15 minutes. Remove weights and perform PT test on all weld joints of the ladder steps and connections lugs on upper and lower of the ladder to check for weld cracks or indications.

8.0 GENERAL REQUIREMENTS: None.

0118-2 image1.jpg

File details come from the government source that posted it.