SOW_Alan_Shepard_PORTACCOMLADDERREPAIR.doc
DOC document 86 KB Posted
- Solicitation number
- N3220519Q4602
About this file
SOW Port Accomodation Ladder USNS Alan Shepard
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SO_19-002__PORT_ACCOM_LADDER_RESCUE_BOAT_REPAIR_ASD_Rev_1.doc | DOC document | |
| N3220519Q4602_COMBINED_SYNOPSIS_SOLICITATION.docx | DOCX document | |
| Limited_Source_Memo.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS ALAN SHEPARD
(T-AKE 3)
outfit, furnishings and habitability
5 Sept 2018
ITEM NO. SO 19-002
Category "A"
N756/EO
PORT Accommodation Ladder REPAIR
1.0 ABSTRACT:
1.1 This item describes the requirement to repair and weight test the Port Accommodation Ladder.
2.0 REFERENCES:
2.1 Fassmer Dwg 12.1544-203.00.00C Accommodation Ladder 13.16 X 0.75M with Auto Turning Over Device
2.2 IMO MSC.1/Circ. 1331 dtd 11 June 2009, Guidelines for construction, Installation, Maintenance and Inspection/Survey of Means of Embarkation and Disembarkation.
3.0 ITEM LOCATION/DESCRIPTION:
3.1 Location/Quantity:
3.1.1 Main deck port side, Frame 62.
3.1.2 Quantity: One (1) each accommodation ladders.
3.2 Item Description/Manufacturer's Data:
3.2.1 Refer to reference 2.1.
a. Accommodation Ladder is Aluminum.
3.2.2 Bill of Materials (Contractor Furnished):
| Description |
| Specification |
| QTY |
| Weight Test Kit (Rental) |
| Water Bags |
| 1 Kit |
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES:
| Description |
| Specification |
| QTY |
| Wire Rope |
| 14mm Dia X 40.5m or 9/16” X 131’ Length (Fassmer Dwg 12.1566-203.00.00.0 Piece 26 or equal) |
| 1 Each |
| Turnbuckles and bushings. |
| Stainless Steel |
| 4 Each |
5.0 NOTES:
5.1 Performance Period will be 5 – 18 November 2018
5.2 Location of work will be Jebel Ali in the U.A.E.
5.3 THIS SHIP CONTAINS HIGH VOLTAGE (HV) ELECTRICAL SYSTEMS. OBEY ALL POSTED AND VERBAL INSTRUCTIONS REGARDING SAFETY AND EXCLUSION FROM HIGH VOLTAGE AREAS. AT NO TIME APPROACH, WORK ON, OR ENTER A HIGH VOLTAGE AREA WITHOUT PROPER AUTHORIZATION.
6.0 QUALITY ASSURANCE REQUIREMENTS: None additional.
7.0 STATEMENT OF WORK REQUIRED:
7.1 Provide the service FASSMER Original Equipment Manufacturer (OEM) authorized technical representative to repair the Port accommodation ladder.
7.2 Ship the required water bags required for weight test of the accommodation ladder. FASSMER is responsible to ensure all customs clearance is arranged to ensure the water bags are delivered in adequate time to perform the weight test. FASSMER to arrange return shipping and custom clearance.
7.3 Verify accommodation ladder has an identification plate provided by OEM. The maximum carrying load is located on the identification plate.
7.4 Perform reference 2.2 maintenance and testing.
7.4.1 Inspect each accommodation ladder and gangway for signs of distortion, cracks and corrosion.
7.4.2 Inspect stanchions to ensure they are straight.
7.4.3 Inspect guard ropes for wear.
7.4.4 Ensure moving parts are free to turn/move.
7.4.5 Replace hoist wire.
7.4.6 Inspect accommodation ladder steps, platforms, all support points such as pivots, rollers, etc.; all suspension points such as lugs, brackets, etc.; stanchions, rigid handrails, hand ropes and turntables; davit structure, wire and sheaves, etc. for wear, corrosion or other signs of failure.
7.5 Perform Static Weight Tests on the Port Accommodation Ladder System in the presence of the MSCREP and ABS Surveyor.
7.5.1 Static weight test the port ladder, with a distributed load, while it is rigged and suspended on an angle of fifty (50) degrees with the horizontal.
7.5.2 Evenly distribute the maximum operational load (taken from identification plate) over the entire length of the accommodation ladder.
7.5.3 Maintain static load for a minimum of ten (10) minutes.
7.6 Operational Test:
7.6.1 Show that all eight (8) outriggers can transition from the stowed position to the deployed position and back again, with the safety net installed.
7.6.2 Raise and lower each accommodation ladder with the maximum operational load (taken from identification plate) evenly distributed over the entire length of the accommodation ladder.
7.7 Perform thorough visual examination for damages after all weight and operational tests.
7.8 Provide a service report with the appropriate IMO check off sheets indicating that the Port accommodation ladder has had a successful five test in accordance with reference 2.2.
7.9 Stamp test dates on Accommodation Ladder information plate located shipboard 01 level near where accommodation ladder is attached to ship.
7.10 Manufacturer's Representative:
7.10.1 Point of Contacts For OEM Services or material:
Tim Klaybor
General Manager
Fassmer Service America, LLC
6135 NW 167 Street (Unit E-6)
Miami, FL 33015
Phone 305-557-8875
Mobile 562-248-8683
Fax 305-557-8874 tk@fassmerusa.com
8.0 GENERAL REQUIREMENTS: None Additional.
SO 19-002
File details come from the government source that posted it.