SOW_RICHARD_E_BYRD_V091.docx

DOCX document 27 KB Posted

Attached to
Forklift Safety Certification and Preventive Maintenance Federal contract opportunity
Solicitation number
N32205-17-Q-7197
Issued by
Department of the Navy Military Sealift Command

About this file

Statement of work

View the file

Other files for this federal contract opportunity

Other files attached to Forklift Safety Certification and Preventive Maintenance, newest first.
File Type Posted
WD_15-5563_PORTLAND_OR.txt TXT text file
RICHARD_E_BYRD_V091TECHNICAL_EXHIBIT_2___Electric_Forklift.docx DOCX document
RICHARD_E_BYRD_V091TECHNICAL_EXHIBIT_1___Safety_Certification.docx DOCX document
RICHARD_E_BYRD_V091TECHNICAL_EXHIBIT_3___Diesel_Forklift.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. Purpose: In accordance with ref (a) and (b), a quote is requested to provide Materials Handling Equipment (MHE) service and support to include an open/inspection, repairs, services, and/or materials. The following information and requirements are hereby provided for planning and pricing purposes. Submission of “Price & Availability Feedback” does not constitute a guarantee of purchase, service contract, or delivery order.

2. Vessel: USNS RICHARD BYRD

3. Location of Equipment/Services: VIGOR MARINE SHIPYARD, PORTLAND OR.

4. Period of Performance: 01 OCT 2017 to 15 DEC 2017

5. SOR : N231947255V091

6. Statement of Work (SOW): The following work items shall be accomplished by the selected service provider (contractor) in conjunction with this repair and maintenance requirement. The Government intends to award a Fixed Price Contract to the selected service provider:

a. Services to MHE identified in Tables 1 and 2, below, will be performed at the Contractor’s maintenance facility. The Contractor’s quote shall specify the proposed location of the service and provide a summary of the proposed process for maintenance, repairs, and safety recertification.

b. If the service provider is capable of arranging transportation of the MHE assets to/from the service provider’s facility, the quote may include a separate line entry for transportation of the assets. If the service provider is unable to arrange transportation, the quote shall specify this and request the Government arrange transportation

c. Contractor shall perform a periodic maintenance service on all units identified in Table 1.

The maintenance shall be completed in accordance with the requirements Identified in Technical Exhibits 2 and 3.

d. Contractor shall perform an operational evaluation and weight test on the ordnance-handling manual pallet trucks identified in Table 2.

e. Contractor shall complete a safety certification on all units identified in Table 1 and 2. The safety certification shall be completed in accordance with the requirements set forth in NAVSEA Manual SW023-AH-WHM-010 reference (a) and Technical Exhibit 1.

f. Contractor shall complete a fork inspection on all units identified in Table 1 in accordance with the Fork Maintenance Inspection Procedures listed in NAVSUP Pub 538 reference (b).

g. Contractor shall perform a periodic maintenance service on the aerial work platform (AWP) identified in Table 2 in accordance with manufacturer recommendations.

h. Contractor shall complete a safety certification and weight test on the aerial work platform (AWP) listed in Table 2 in accordance with the requirements set forth in reference (b). Refer to NAVSUP P-538, 6th edition, para 8-7.6 and figure 8-16.

i. Contractor shall perform an operational inspection and a periodic maintenance service on the ordnance handling trailers identified in Table 2 in accordance with manufacture recommendations.

j. Contractor shall provide a condition report on each unit identified in Table 1 through 2. All condition reports shall contain, at the minimum, the ship's name, the MSC MHE serial number, manufacture identification number, make and model, a complete list of recommended repairs and services, and all associated pricing information.

k. Contractor shall service all battery chargers listed in Table 3 to ensure proper operation, voltage, and amperage settings.

7. Equipment to be serviced:

USNS RICHARD BYRD - TABLE 1

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE/SAFETY
HYSTER
E40XM
2301018
F108G04676T
STD ELEC
HYSTER
E40XM
2302237
F108G01525D
STD ELEC
HYSTER
E40XM
2302238
F108G01533D
STD ELEC
HYSTER
E40XM
2302239
F108G01565D
STD ELEC
HYSTER
E40XM
2302240
F108G01568D
STD ELEC
HYSTER
E60XM
2302241
F108G01552D
STD ELEC
HYSTER
E60XM
2302242
F108G01571D
STD ELEC
HYSTER
E60XM
2302243
F108G01574D
STD ELEC
HYSTER
E60XM
2302244
F108G01576D
STD ELEC
HYSTER
E60XM
2302245
F108G01577D
STD ELEC
HYSTER
E60XM
2302246
F108G01579D
STD ELEC
HYSTER
E100Z
2302247
E098N01706E
STD ELEC
HYSTER
E100Z
2302248
E098N01712E
STD ELEC
HYSTER
E100Z
2302249
E098N01714E
STD ELEC
HYSTER
E100Z
2302250
E098N01715E
STD ELEC
HYSTER
S60FTG
2302251
F187G09985E
STD DIES
HYSTER
S60FTG
2302252
F187G11707F
STD DIES
HYSTER
S60FTG
2302253
F187G11708F
STD DIES
HYSTER
S60FTG
2302254
F187G11731F
STD DIES
HYSTER
S60FTG
2302255
F187G11732F
STD DIES
HYSTER
S60FTG
2302256
F187G11734F
STD DIES
HYSTER
S60FTG
2302257
F187G11735F
STD DIES
HYSTER
S60FTG
2302258
F187G11802F
STD DIES
HYSTER
S60FTG
2302406
F187G14634G
STD DIES
HUBTEX
VQ 45/4
2900078
60057
MSL

USNS RICHARD BYRD - TABLE 2

MANUFACTURER
MODEL
MSC NUMBER
SERIAL NUMBER
TYPE
WESLEY INT'L
42-27-60XTSB
28-00017
28-00017
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00018
28-00018
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00021
28-00021
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00022
28-00022
PALLET TRUCK
WESLEY INT'L
42-27-60XTSB
28-00024
28-00024
PALLET TRUCK
GENIE
Z-45/25J IC
25-00005
Z452508A-35564
BOOM, ARM LIFT
BLUE GIANT
PTW-60E
2600014
9130355
EPJ
BLUE GIANT
PTW-60E
2600020
9230553
EPJ
ENTWISTLE
EJ-42338
2903017
31891-030
10K
ENTWISTLE
EJ-42338
2903018
61843-017
10K
ENTWISTLE
EJ-42338
2903019
61843-018
10K
ENTWISTLE
EJ-42338
2903020
61891-031
10K

USNS RICHARD BYRD - TABLE 3

MANUFACTURER
SERIAL NO.
MODEL
NOMINAL OUTPUT CHARACTERISTICS
YUASA-EXIDE INC
FB5500
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5499
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5494
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5504
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5501
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5495
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5496
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5503
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5502
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5498
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5505
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5497
LT-18-1000
36V DC 1000 A/HR
YUASA-EXIDE INC
FB5507
SLH3-40-850 B
72 V DC
YUASA-EXIDE INC
FB5508
SLH3-40-850 B
72 V DC
YUASA-EXIDE INC
FB5506
SLH3-40-850 B
72 V DC

8. Deliverables:

The contractor shall provide:

(1). A Condition Report for each unit listed in Table 1 through 3. The condition reports will be provided to the MHE Program Manager at MSC Norfolk (N48) within 5 days of receipt of MHE. A copy of the condition reports will be provided to the ship’s Master or his designated representative upon request.

(2). A complete and signed MHE Safety Certification Form for each unit listed in table 1 and 2. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.

(3). A complete and signed Fork Inspection Form for each unit listed in Table 1. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.

(4). A complete and signed safety certification form for the aerial work platform (AWP) listed in Table 2. The original signed forms shall be provided to the ship's Master or his designated representative. A copy of the signed forms shall be provided to the MSC Norfolk MHE Program Management office.

(5). A completed MHE or AWP (as appropriate) Safety Certification Marking stenciled or affixed to each unit listed in Tables 1 through 2 (in accordance with the requirements listed in the NAVSUP P-538).

(6). A condition report on all batteries removed from the electric forklifts listed in Table 1.

(7). A completion report on all battery cables installed.

9. Qualifications. The selected service provider/contractor must meet the following qualifications:

a. All management and technical personnel performing above listed services must be able to demonstrate the following:

- Experience performing safety certifications on shipboard-approved MHE in accordance with the requirements set forth in the NAVSEA SW023-AH-WHM-010, NAVSUP PUB 538, and equipment technical manuals.

- Experience interpreting, trouble-shooting, and resetting HYSTER on-board dash displays.

b. Contractor personnel performing repairs and maintenance onboard MSC vessels shall abide by all DOD, Navy, and MSC security requirements and clearance procedures required to access U.S. Government facilities and MSC vessels.

c. Proof of U.S. citizenship shall be provided in order to enter a U.S. military facility, if requested by the Government. When accessing US Government installation, proposed contractor personnel shall be vetted by the Government through the Government's El Paso Intelligence Center (EPIC) before accessing the Government installation

d. The contractor must be able to perform the required services within the period of performance identified in the Statement of Work. If additional work is identified, and approved by the Government, the Contractor must have the ability to ride the vessel underway to complete this additional work.

10. Technical Points of Contact (POCs):

- POC: Tangya Ragin – tangya.ragin.ctr@navy.mil

- Alternate POC: Robert Hall - Robert.m.hall1.ctr@navy.mil

11. Shipboard Points of Contact (POC):

RICHARD BYRD Chief Engineer:
Vu D Tran
Email: vu.d.tran.civ@ake4.navy.mil (and/or)
byrd.cheng@ake4.navy.mil
Ship phone: 619-533-7253 / Radio: 619-533-7254
RICHARD BYRD Principal Port Engineer:
William Lombos
Email:willie.lombos@navy.mil
Office:757-943-7949
RICHARD BYRD Supply Officer:
Kelvin Thomas
Email: kelvin.t.thomas.civ@ake4.navy.mil

12. RFQ Submittal: In response to the above information and statement of work or work item, the contractor is afforded the opportunity to submit a quote (consistent with applicable contract rates) and total pricing to provide the aforementioned service(s) or materials.

a. Contractor shall ensure their designated representatives can access the specified Government Activity, Shipyard, and vessel prior to submitting a quotation.

b. Quotes shall be provided on company letterhead and reference the applicable RFQ number (provided above)

c. Quotes shall be provided to the following contracting officer, via email:

Melvin Frazier Military Sealift Command Simplified Acquisition Program Branch, N102 471 "C" Street Bldg. SP-64 Norfolk, VA 23511 Phone: 757.443.5906 Fax: 757.443.5979 E-mail: melvin.frazier@navy.mil

File details come from the government source that posted it. Updated .