N32205-16-T-4201_P0001.doc
DOC document 49 KB Posted
- Attached to
- Sea Water Cooled Marine Screw Drive Chiller
- Solicitation number
- N32205-16-T-4201
About this file
Amendment 0001
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N32205-16-T-4201.doc | DOC document | |
| J A_Sea_Water_Cooler_Chiller.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN extended description has changed from P/N 30HXS136RY-6-MAR, Sea Water Cooled Marine Screw Drive Chiller - Skid-Mounted with Water Regulating Valve and Vibration Mounts and mounting brackets shipped loose with unit. Made from Production Model 30HXS136ZY-671KA. Chiller shall be modified for shipboard application. The modifications include: (1) Factory installed control voltage transformer (115-v) in the above panel. (2) Non Fused Disconnect (NFD) Switches have been installed. Each disconnect will stop power for that circuit. Circuit A NFD will de energize the control transformer. (3) ANSI Raise Faced Flanges on the Cooler Assembly. Cooler Heads have been insulated from the factory. (4) NEMA 4 Control Panel and compressor junction boxes with seal tight conduit have been installed. The pressure transducers have been moved into NEMA 4 junction boxes with extended capillary lines. (5) Minimum Load Control, Suction Service Valve and Marine 2-part Epoxy Paint options included. (6) Loose Ship Items include: Water Regulating Valve, Vibration Mounts for Chiller and Mounting Brackets. to P/N 30HXS136RY-6-MAR, Sea Water Cooled Marine Screw Drive Chiller - Skid-Mounted with Water Regulating Valve and Vibration Mounts and mounting brackets shipped loose with unit. Made from Production Model 30HXS136ZY-671KA. Chiller shall be modified for shipboard application. The modifications include: (1) Factory installed control voltage transformer (115-v) in the above panel. (2) Non Fused Disconnect (NFD) Switches have been installed. Each disconnect will stop power for that circuit. Circuit A NFD will de energize the control transformer. (3) ANSI Raise Faced Flanges on the Cooler Assembly. Cooler Heads have been insulated from the factory. (4) NEMA 4 Control Panel and compressor junction boxes with seal tight conduit have been installed. The pressure transducers have been moved into NEMA 4 junction boxes with extended capillary lines. (5) Minimum Load Control, Suction Service Valve and Marine 2-part Epoxy Paint options included. (6) The Water Regulating Valve (WRV) shall be suitable for use in Seawater at 150 PSI and 60 - 140 deg F. 4" NPS, Flanged Bronze body, Stainless Steel sensing lines. Metrex Valve Corp Model # MDFPMT3130FL3W or similar. (7) Loose Ship Items include: Water Regulating Valve, Vibration Mounts for Chiller and Mounting Brackets..
DELIVERIES AND PERFORMANCE
The following Delivery Schedule item for CLIN 0001 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
| 02-MAY-2016 |
| 1 |
| MSC NORFOLK W143 |
MSC W143
BUILDING W143 DOORWAY 10,1968 GILBERT ST.
NORFOLK VA 23511
757-443-3900
FOB: Destination N32205
To:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
| 01-JUL-2016 |
| 1 |
| MSC NORFOLK W143 |
MSC W143
BUILDING W143 DOORWAY 10,1968 GILBERT ST.
NORFOLK VA 23511
757-443-3900
FOB: Destination N32205
(End of Summary of Changes)
File details come from the government source that posted it. Updated .