RFC-0001_Item_910_Work_Scope.doc

DOC document 39 KB Posted

Attached to
Regular Overhaul and Dry-Docking (ROH/DD) for the USNS YUKON (T-AO 202)
Solicitation number
N32205-16-R-1000
Issued by

View the file

Other files

File Type Posted
16-R-1000_SOLICITATION_YUKON_AMEMDMENT_0004.doc DOC document
amd_0003.pdf PDF
16-R-1000_SOLICITATION_YUKON_Rev_2.doc DOC document
16-R-1000_SOLICITATION_YUKON_AMENDMENT_0002.pdf PDF
16-R-1000_SOLICITATION_YUKON_AMENDMENT_0001_Rev-1.pdf PDF
16-R-1000_SOLICITATION_YUKON_AMENDMENT_0001_COMPLETE.pdf PDF
RFC-0002_ITEM0_407_Spec_Clarification.doc DOC document
J-3_Category_B_Items.xls XLS spreadsheet
J-2_Category_A_Items.xls XLS spreadsheet
J-11_Dry_Dock_Evaluation_Form.docx DOCX document
J-4_GFP_YUKON.pdf PDF
J-10_Interport_Differential.doc DOC document
J-14_NON_DISCLOSRE_AGREEMENT_FOR_GOVN'T_TECHNICAL_DATA_(V1_1_2-27-14).docx DOCX document
J-7_MSC_Ship_Repair_Facility_Survey.doc DOC document
J-5_Subcontracting_Plan_YUKON.docx DOCX document
J-6_WI_015_CDRL.pdf PDF
J-8_Request_for_Spec_Clarification.doc DOC document
J-9_Disclosure_of_Lobbying_Activities_SF-LLL.doc DOC document
J A_FedBizOpps_Redacted.pdf PDF
J-13__PAST_PERFORMANCE_QUESTIONNAIRE.docx DOCX document
J-12_Past_Performance_Data.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N32205-16-R-1000

USNS YUKON (T-AO 202)

REQUEST FOR SPECIFICATION CLARIFICATION

NAME OF CONTRACTOR: __________________________________

SPECIFICATION ITEM NO.: _910____________________

PARAGRAPH / SECTION NO:_3.1.2, 4.1, 7.1.3,___________________

TITLE: PORT_CRPP BLADE INSPECTION AND REPAIR_________________

QUESTION:

The title for WI 910 PORT CRPP BLADE INSPECTION AND REPAIR and Para. 3.1.2 indicate quantity (1) CRPP blade to be worked on.

Paragraph 4.1 and 7.1.3 makes reference to both the Port & Stbd CRPP blades.

Please clarify the quantity of CRPP blades for work for WI 910.

ANSWER:

1. In WI 910 we are only concerned with the four 4 blades on the Port Hub. The STBD CRPP blades will be inspected and repaired under WI 916.