USNS HENRY J. KAISER (T-AO 187)
N32205-15-R-1008
REQUEST FOR SPECIFICATION CLARIFICATION # 002
NAME OF CONTRACTOR: ________________________
SPECIFICATION ITEM NO.: __301______________
PARAGRAPH / SECTION NO: 2.2.1; 7.1 .
TITLE: SWITCHBOARD THERMAL SURVEY AND CLEANING.
QUESTION:
BAE would like to inquire as to why the Thermographic survey onboard the USNS Henry J. Kaiser must be accomplished by a Level III Thermographer as stated in the attached Work Item 305 para. 7.1. Our Electronic Sub-contractors ( Fairlead, Pionteight, etc..) have been doing thermographic surveys with a level I certification on multiple MSC vessels in various classes for years.
Para 7.1 of the work item also states "in accordance with Enclosure 2.2.1 para. A and B" (this refers to MSFSC Standard Item No. 20 para. A and B). This standard item does not specify the level of thermographic competence required. Please clarify
ANSWER:
Level I certification will be accepted if camera operator has atleast five years speacialzed experience conducting Thermographic Surveys onboard ships.
ATTACHMENT J - 8