Statement of Work APN7-16 Requirement
BS-650013.APN7METCAL93- PHY/DIM OPT CALSTDS
A. Background The use of NAVAIR METCAL equipment funding is to procure Calibration Standards (CALSTDs) and ancillary equipment for Aviation Fleet Intermediate Calibration Activities, Fleet Training Activities and Aviation Navy Calibration Laboratories (NCLs) to support Aviation Organizational and Intermediate (I) level maintenance assets. All Cal Standards listed for procurement must first go through an approval process. This process includes: initial submission by the fleet; review and prioritization by the Fleet TYCOM’s; laboratory workload justification and standardization review by a NAVAIR METCAL technical review team; overall procurement strategy review to assess overall program objectives, priorities and funding.
REQUIREMENTS:
1. Mfr. one year warranty with sticker affixed to each unit plus a warranty certificate.
2. Calibration Certificate and calibration sticker (as applicable for each unit)
3. Units (over $5,000) shall have an IUID Label applied per DFAR 252.211-7003.
4. Manufacturer’s Standard Operating and servicing manuals (CD version acceptable) shall be provided with each unit. The DFARS clause listed below must be referenced in all contracts and the manufacturer made aware that the use/reproduction of tech data/manuals (for government use only) will follow these use guidelines.
DFARS SUBPART 227.71 - Rights in Technical Data
B. Tasking:
The contractor shall provide the following equipment:
1) P/N X431-0002 Jerome Mercury Vapor Analyzer w/o comm Qty 11 To include the following:
a) Gold film sensor
b) Range: 0.001 to 0.999 mg/m³
c) Sensitivity: 0.003 mg/m³ Hg
d) Precision: 5% relative standard deviation @ 0.100 mg/m³ Hg
e) Accuracy: ±5% @ 0.100 mg/m³ Hg
f) Flow rate: 750cc/min (0.75 liter/min)
g) Batteries: Rechargeable Nickel Cadmium
h) Fuse: 1A 250V 5X20
i) Weight: 7lbs.
j) Operating environment: 0°-40°C, non-condensing, non-explosive
k) Warranty
l) Certification
m) P/N Y431-0901 ACCESSORY KIT 431-X Qty 11 To include the following:
a. Probe: P/N 1400-2002
b. Tubing: P/N 1400-3010
c. Trimmer Tool: P/N 2300-0001
d. Fritware .25”: P/N 2600-3039
e. 115 Vac line cord: P/N 6000-4003
f. Manual for accessory kit: P/N SS-086
n) P/N 700-0046 431X USER MANUAL Qty 11
2) P/N Y411-0904 Jerome hard Carrying Case Assembly x431/x631 Qty 11 C. Deliverables
Delivery of the equipment shall be provided at the following address:
COMMANDER
NAVAIR Calibration Standards
MCAS,
(UIC N48535)BLDG 612, Bay 9
Beaufort, SC 29904-5002 D. Delivery Date
Delivery shall be no later than 4 weeks after award of contract, and shall be absolutely no later than May 01, 2016. ***PARTIAL SHIPMENT ACCECPTED*** E. Invoicing All invoicing shall be submitting into Wide Area Workflow for payment after ALL material is received in the condition as stated in section B.