wet_cell_u-dr-1 rev 5.pdf

PDF 1 MB Posted

Attached to
Hydrostatic Pressure Chamber Federal contract opportunity
Solicitation number
N0025321Q0031
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to Hydrostatic Pressure Chamber, newest first.
File Type Posted
N0025321Q0031 A0001.pdf PDF
CDRL A001 redacted.pdf PDF
CDRL A004 redacted.pdf PDF
N0025321Q0031.pdf PDF
CDRL A002 redacted.pdf PDF
CDRL A003 redacted.pdf PDF
CDRL B001 redacted.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FORM U-DR-1 USER’S DESIGN REQUIREMENTS FOR SINGLE-CHAMBER PRESSURE VESSELS

Owner:

Service:

Internal Design Pressure:

External Design Pressure:

Diameter:

M A WP Internal:

Corrosion Allowance: Shell

Int. Ext.

Heads

Int. Ext.

Nozzles

Int. Ext.

Jacket

Int. Ext.

Coil

Int. Ext.

Supports

Int. Ext.

Internals Corrosive Service?

Y es No

Minimum Design Metal T emperature (MDMT) – Case 1

M A WP External:

OPER A TING CONDITIONS:

DESIGN CONDITIONS:

M A TERIALS

NOZZLE SCHEDULE

Case 1 Case 2

Minimum Pressure

Pressure Temperature

Maximum Pressure Minimum T emperature Maximum T emperature

National Board Registration Required:

Y es No

Length, T angent-to- T angent: T ype:

V ertical Horizontal Sphere

Item No.: Liquid Level:

Specific Gravity:

Operator: Country of Installation: City of Installation: State/Province of Installation:

Canadian Registration Required:

Y es No

Special Service:

Lethal (L) Direct Firing (DF)

Same as Design Pressure Calculated by Manufacturer:

Same as Design Pressure

Deg @ Due to:

Calculated by Manufacturer:

Unfired Steam Boiler (UB)

Overpressure Protection:

V alve Rupture Disk

Process Other

Cyclic Service: Cycles per Design Life years Y es

UBC IBC

Other None

Wind Loading: Wind Speed Classification Category

Exposure Category

T opographic Factor

Elevation ASCE 7

UBC IBC

Other None

Seismic Loading:

Per Code Process Required

PWH T : Soil Profile Classification: Other Loadings per UG-22: ASCE 7

No

V essel Support:

Component

Description

07/17

Number Required

Size Flange T ype

Class Description Number Required

Size Flange T ype

Class

Shell

Hemispherical Head

T oriconical Head

Nozzles

Stiffener Rings

Attachments

Reinforcing Pads

Specification Component

Ellipsoidal Head

T orispherical Head

Conical Head

Flanges

Pressure-Retaining Bolts

Internals

Other

Specification

T ype: Rating (hr):Legs Skirt Lugs Saddles

Y es No

T ype Thickness Density Coating Specification External Internal Permitted Prior to Pressure T est

Y es No Fireproofing:

Fatigue Analysis? Y es No

Ambient T emperature

Minimum Design Metal T emperature (MDMT) – Case 2

Deg @ Due to: Process Other Ambient T emperature

Other System Design

Insulated: Y es No By Manufacturer By Others

Temp. Gradients Diff. Thermal Exp.

Deflagration

GENERAL NOTES

BODY FLANGE REQUIREMENTS

WELDED PRESSURE JOINT REQUIREMENTS

SKETCH

CE R TIFIC A TION

Date:

W e certify that the statements made in this form are accurate and represent all details of design as per the user or his designated agent [see Nonmandatory Appendix NN]

Description

Category D

Category C

Category B Head-to-Shell

Other

Body Flanges

Nozzle Flanges

Category A

DESIGN BASIS:

JOINT LOC A TION

U W -3

TYPE OF JOINT

(Use T ypes as Described in U W -12)

NDE WITH COMMENTS

HEAD THICKNESS BASED ON:

JOINT EFFICIENCY E =

SHELL AND CONE THICKNESS BASED ON:

JOINT EFFICIENCY E =

T ype Facing/Surface Finish Gasket Style Joint Assembly (See ASME PCC-1)

User:

Signed:

Registration Identification:

Registration Seal (Optional)

(Representative)

(Optional)

07/15

FORM U-DR-1 (Back) alexander.j.king1 Stamp

Owner: NUWC Keyport
Operator: NUWC Keyport
Country of Installation: USA
StateProvince of Installation: WA
City of Installation: Keyport, WA
Service: fresh water
1: 100%
2: 1
Item No:
Diameter in: 16" OD
Length T angentto T angent: 48
Lethal L: Off
V alve: On
Other: Off
Rupture Disk: Off
Unfired Steam Boiler UB: Off
System Design: Off
Minimum PressureCase 1: 0 psig
Maximum PressureCase 1: 150 psig
Minimum T emperatureCase 1: 35F
Maximum T emperatureCase 1: 130F
Minimum PressureCase 2:
Maximum PressureCase 2:
Minimum T emperatureCase 2:
Maximum T emperatureCase 2:
PressureInternal Design Pressure: 175 psi
T emperatureInternal Design Pressure: 32-145F
PressureExternal Design Pressure:
T emperatureExternal Design Pressure:
M A WP Internal:
M A WP External:
Same as Design PressureMinimum Design Metal T emperature MDMT Case 1:
Deg:
Same as Design PressureMinimum Design Metal T emperature MDMT Case 2:
Deg_2:
InternalsExt:
Corrosion AllowanceRow2:
IntRow1: 1/16"
ExtRow1:
IntRow1_2: 1/16"
ExtRow1_2:
IntRow1_3: 1/16"
ExtRow1_3:
IntRow1_4:
ExtRow1_4:
IntRow1_5:
ExtRow1_5:
IntRow1_6:
ExtRow1_6:
InternalsRow2:
undefined_4: 1
Cycles per: week
Design Life: 40
Wind Speed:
Classification Category:
Exposure Category:
T opographic Factor:
Elevation:
Temp Gradients: Off
Deflagration: Off
Soil Profile Classification:
Process Required: Off
Diff Thermal Exp: Off
External:
Thickness:
Internal:
Density 1:
Density 2:
Coating Specification: *
T ype:
Rating hr:
SpecificationShell: SA516-Gr 70
SpecificationEllipsoidal Head:
SpecificationHemispherical Head:
SpecificationT orispherical Head:
SpecificationT oriconical Head:
SpecificationConical Head:
SpecificationNozzles: SA516-Gr 70
SpecificationFlanges: SA516-Gr 70
SpecificationStiffener Rings:
SpecificationPressure Retaining Bolts: Alloy steel (grade 8)
SpecificationAttachments: SA516-Gr 70
SpecificationInternals:
SpecificationReinforcing Pads:
Other_6:
SpecificationOther:
DescriptionRow1: Ends of vessel
Number RequiredRow1: 2
SizeRow1: 16"
Flange T ypeRow1: flat face
ClassRow1: 150
DescriptionRow1_2:
Number RequiredRow1_2:
SizeRow1_2:
Flange T ypeRow1_2:
ClassRow1_2:
DescriptionRow2: 1/2" NPT
Number RequiredRow2: 2
SizeRow2: .5"
Flange T ypeRow2: N/A
ClassRow2: N/A
DescriptionRow2_2:
Number RequiredRow2_2:
SizeRow2_2:
Flange T ypeRow2_2:
ClassRow2_2:
DescriptionRow3: Accessory flanges
Number RequiredRow3: 3
SizeRow3: .75"
Flange T ypeRow3: flat face
ClassRow3: 150
DescriptionRow3_2:
Number RequiredRow3_2:
SizeRow3_2:
Flange T ypeRow3_2:
ClassRow3_2:
DescriptionRow4:
Number RequiredRow4:
SizeRow4:
Flange T ypeRow4:
ClassRow4:
DescriptionRow4_2:
Number RequiredRow4_2:
SizeRow4_2:
Flange T ypeRow4_2:
ClassRow4_2:
DescriptionRow5:
Number RequiredRow5:
SizeRow5:
Flange T ypeRow5:
ClassRow5:
DescriptionRow5_2:
Number RequiredRow5_2:
SizeRow5_2:
Flange T ypeRow5_2:
ClassRow5_2:
DescriptionRow6:
Number RequiredRow6:
SizeRow6:
Flange T ypeRow6:
ClassRow6:
DescriptionRow6_2:
Number RequiredRow6_2:
SizeRow6_2:
Flange T ypeRow6_2:
ClassRow6_2:
DESIGN BASIS:
JOINT EFFICIENCY E:
undefined_14:
TYPE OF JOINT Use T ypes as Described in U W 12Category A:
NDE WITH COMMENTSCategory A:
TYPE OF JOINT Use T ypes as Described in U W 12HeadtoShell:
NDE WITH COMMENTSHeadtoShell:
TYPE OF JOINT Use T ypes as Described in U W 12Other:
NDE WITH COMMENTSOther:
TYPE OF JOINT Use T ypes as Described in U W 12Body Flanges: 4 or 5
NDE WITH COMMENTSBody Flanges:
TYPE OF JOINT Use T ypes as Described in U W 12Nozzle Flanges: 4 or 5
NDE WITH COMMENTSNozzle Flanges:
TYPE OF JOINT Use T ypes as Described in U W 12Category D:
NDE WITH COMMENTSCategory D:
DescriptionRow1_3: End flanges
T ypeRow1: blind flange
FacingSurface FinishRow1: flat face
Gasket StyleRow1: O-ring
Joint Assembly See ASME PCC1Row1: Legacy or Alt Pattern 1
DescriptionRow2_3: pressure retaining attachments
T ypeRow2: blind flange
FacingSurface FinishRow2: flat face
Gasket StyleRow2: O-ring
Joint Assembly See ASME PCC1Row2: Legacy or Alt Pattern 1
GENERAL NOTESRow1: Intended use: Attach necessary components to the open end. Fill vessel with tap water at 70-100 psi through 1/2" piping. Use 1.5 GPM max pump to raise pressure to a max of 150 psi. Hold pressure per test requirements. Vent pressure through overflow tube then drain the pressure vessel through 1/2 piping. A vacuum relief is included in the system. Material Note: Stainless steel can be used if it is demonstrated that there is a cost benefit to doing so. *Carboguard 890H or equivalent
Date:
User:
Registration Identification:
Check Box1: Off
Check Box2: Off
Text9:
Text10:
Text11:
Text12:
Group1: Choice2
Group2: Choice2
Group3: Off
Group4: Choice2
Group10: Off
Group11: Off
Group20: Choice2
Group30: Choice2
Corrosion AllowanceRow1:
roup6: Choice2
group66: Off
group67: Off
group68: Off
group69: Choice5
group70: Choice5
group72: Off
Text7:
Group29: Off
Group30x: Off

File details come from the government source that posted it. Updated .