N0017821Q6637 Amendment 0001.pdf

PDF 154 KB Posted

Attached to
Custom Tow Trailer Federal contract opportunity
Solicitation number
N0017821Q6637
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to Custom Tow Trailer, newest first.
File Type Posted
N0017821Q6637.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to provide revised Specif ications and CAD Draw ings. The CAD Draw ings are in support of the Specif ications and provided in order to clarify the general placement and oreintation clarity for most, but not all, of the required features.

All other terms and conditions remain the same.

NOTE: A CAD Draw ing must accompany the quote to approve the design.

1. CONTRACT ID CODE PAGE OF PAGES

1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 26-Feb-2021

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N0017821Q6637

X 9B. DATED (SEE ITEM 11)

11-Dec-2020

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

26-Feb-2021

CODE

NSWCDD 3

ATTN:KAREN LOPEZ/026 KAREN.LOPEZ@NAVY.MI

L

17632 DAHLGREN ROAD

DAHLGREN VA 22448-5110

N00178 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

doritha.newman@navy.milEMAIL:TEL:

DORITHA J. NEWMAN / CONTRACTING OFFICER

N0017821Q6637

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION A - SOLICITATION/CONTRACT FORM

The required response date/time has changed from 18-Dec-2020 05:00 PM to 03-Mar-2021 05:00 PM.

SECTION C - DESCRIPTIONS AND SPECIFICATIONS

The following have been modified:

SPECIFICATIONS

Marine Corps Warfighting Laboratory (MCWL) Operations and Tow Trailer

Type: Portable Frame: Aluminum Length: 28 ft. body length is preferred.

Stabilizing: Stabilizing without being connected to the tow hitch Brakes: Brakes required; the payload is anticipated to be approximately 10,000 lbs of equipment Must have 7000lb axels Minimum of at least 4 keys to every lock

Must have a CAD drawing with the quote to approve the design.

This document lists the requirements and should be used as the primary requirements document. The accompanying CAD file is provided in order to provide general placement and orientation clarity for most (but not all) required features.

Interior:

Clearance: A minimum clearance that will allow a 6ft 4 inch high vehicle to have clearance on the takeoff angle to allow the vehicle to be loaded off the ramp into the trailer

Walls: must be insulated Walls: must have dry erase capability Floor: must have 6 D rings tie down points located at the front, middle and rear.

Floor: must have 2 rows of airline track that runs the length of the floor with at least a

6000 lbs tie down rating. With tie down equipment Walls: airline track from roof to the floor must be located from the side door front side and straight across to allow us to store gear in the front of the trailer Walls must have airline track from roof to floor located from rear side of the side door both sides of wheel well and near rear ramp on both long walls Receptacles: A minimum of 8 NEMA compliant 20 Amp receptacles 1 on each side of the wheel wells and 2 on the front tongue side and 1 on each side of the rear of the trailer.

Must have 10 LED Overhead Lights that run from the front to rear of the trailer Frame of the trailer must be aluminum

N0017821Q6637

Must have at least 2 loading lights located toward the front of the trailer Must have an aluminum subfloor to handle load and tie down ratings

Exterior:

Paint: Preferably, white no logos required.

Roof: Shall support walking on the roof Roof: Access to the roof for mounting antennas; a ladder is a requirement. Located at the front over the toolbox.

Side Personnel Door: Minimum of 36” x 78”. Door must be able to lock to secure gear Rear ramp capable of holding a 4000 lb vehicle as its loaded Rear ramp must have nonskid for easier and safer loading of vehicles and personal walking in and out of rear ramp Electric Awning at least 21 ft located on the same side as the side door At least 5 Docking lights (flood lights) on the rear and sides of trailer 2 one each side and one on the rear.

Must have 4 Access hatch panels spread evenly on the tongue side of the trailer to allow for pass through cable runs Must include 4 manual stabilizer feet on both front and rear of the trailer.

Must have the extended tongue with lockable tool box on the tongue A minimum of 4 NEMA compliant 20 Amp receptacles 2 located on each long side of the trailer both front and rear and must have covers that prevent water damage.

Frame: must be screwless Must have a fold out step at side door Must have rear skid plates for driving in training arears with potholes.

Must have aluminum bar locks on rear of the trailer to allow us to secure the vehicles and gear.

Utilities:

Must have an external interconnection for external power.

HVAC: Shall include a minimum of two 13,500 BTU; roof mount electric AC units with at least 2 heat strips Must come with electric cable to hook trailer to shore power.

Safety:

Regulations: Must include the minimum set of safety equipment to meet Virginia regulations

Spare: Must include a full size spare radial tire. Located on the upper inside front wall nearest the hitch.

(End of Summary of Changes)

File details come from the government source that posted it. Updated .