0211-04_-_Fiber_Optic_MQJs_-_Drawing.pdf
PDF 696 KB Posted
- Solicitation number
- N0017819Q6707
About this file
KITCO Fiber Optics drawings Please Note: Only Authorized Resellers will be accepted.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| posted_SF18.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REV
STATUS
OF
SHEETS
REV G G G G G G G G G G G G G G G G G G G G
SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
REV G
SHEET 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
E S
W B
N A
V S
E A
D R
A W
IN
G
N O
S
H T
R
V
G
APPLICATION
NEXT ASSY USED ON
REVISIONS
REV DESCRIPTION DATE APPROVED
A
B C
RELEASED AS REVISION A.
UPDATE OF REVISION A.
UPDATE OF REVISION B.
10/5/94
4/11/95 9/30/99
DISTRIBUTION STATEMENT A: APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
CAGE CODE
CONTRACT NO.
DEPARTMENT OF THE NAVY
NAVAL SEA SYSTEMS COMMAND
WASHINGTON, D.C. 20362-5101
JUMPERS, TEST EQUIPMENT
FIBER OPTIC
SIZE
A
CAGE
53711
ESWBS
DRAWING NO.
6877804
REV
G
(SIGN ONLY IF ENGINEERING HAS BEEN
“PROVED”BY MANUFACTURE AND TEST
SIGNATURE DOES NOT DENOTE APPROVAL
H. LEWIS
G. BROWN
E. BLUEBOND
G. BROWN
D. KNUDSEN
9/30/99
9/30/99
9/30/99
9/30/99
9/30/99
SCALE: NONE UCI WT GRP SHEET 1 OF 21
APPROVED
ENGINEER
CHECKED
PREPARED
ACCEPTED FOR
NAVSEA
APPROVED BY
NAVSEA
FINISHES:
MATERIAL:
FRACTIONS
ANGLES
P
DECIMALS
.xx+/-
.xxx+/-
DO NOT SCALE DRAWING
VENDOR ITEM DRAWING
D UPDATE OF REVISION C. 1/09/06
E UPDATE OF REVISION D. 2/04/08
F UPDATE OF REVISION E. 5/1/18
G UPDATE OF REVISION F. 8/28/18
LIST OF REFERENCES
REF
NO.
DOCUMENT NUMBER DOCUMENT TITLE
MIL-STD-2042-6
S9086-PF-STM-010/CH-435
MIL-STD-1678-5
MIL-STD-1678-2
A-A-59940/1
A-A-59940/3
MIL-PRF-85045
MIL-PRF-28876
MIL-PRF-29504
FIBER OPTIC TOPOLOGY INSTALLATION STANDARD
METHODS FOR NAVAL SHIPS (TEST)
FIBER OPTIC TOPOLOGY OPERATION MAINTENANCE
AND REPAIR
FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND
MEASUREMENTS. PART 5: DESIGN PHASE,
SUPPLEMENTAL AND LEGACY MEASUREMENTS
FIBER OPTIC CABLING SYSTEMS REQUIREMENTS
AND MEASUREMENTS. PART 2: OPTICAL
MEASURMENTS
CONNECTORS, FIBER OPTIC, SINGLE FIBER SMALL
FORM FACTOR, LC TYPE
CONNECTORS, FIBER OPTIC, SINGLE FIBER ST TYPE
CABLES, FIBER OPTIC
CONNECTORS, FIBER OPTIC
TERMINI, FIBER OPTIC CONNECTOR
W
V S
E A
D R
A W
IN
G
N O
S
SIZE
CAGE
53711
ESWBS
DRAWING NO.
6877804
REV
G
SCALE: NONE UCI WT GRP SHEET 2
1. NOTES
1.1 NAVAL SURFACE WARFARE CENTER DAHLGREN DIVISION, FIBER OPTICS SECTION
IS THE TECHNICAL DIRECTION AGENT (TDA) FOR FIBER OPTICS FOR NAVSEA AND
THE APPROVING ACTIVITY FOR MEASUREMENT QUALITY JUMPERS (MQJs).
1.2 ORGANIZATIONS ARE ALLOWED TO MANUFACTURE MQJs FOR THEIR OWN INTERNAL USE AS LONG AS THE MQJs MEET THE REQUIREMENTS (SECTION 2.0), SPECIFIED
CONFIGURATIONS (SECTION 3.0) AND PASS THE MQJ SELECTION CRITERIA DETAILED IN
MIL-STD-2042 PART 6, METHOD 6F1. ORGANIZATIONS MANUFACTURING MQJs FOR EXTERNAL USE (eg. DISTIBRUTION/SALE) SHALL MEET THE REQUIREMENTS, CONFIGURATIONS, VERIFICATIONS AND APROVAL PROCESS DEFINED IN THIS
DRAWING.
1.3 SUGGESTED SOURCE OF SUPPLY
FOR A COMPLETE LIST OF VENDORS APPROVED TO MANUFACTURE AND SELL
MEASUREMENT QUALITY JUMPER CABLES, PLEASE SEE THE RECOMMENDED TEST
EQUIPMENT LIST ON THE NAVY SHIPBOARD FIBER OPTIC WEBSITE LOCATED AT
www.navsea.navy.mil/Home/WarfareCenters/NSWCDahlgren/WhatWeDo/NavyShipboardFiberOp tics.aspx . VENDOR PART NUMBERS ARE ALSO LOCATED ON THE WEBSITE. DUE TO THE
DYNAMIC NATURE OF WEB ADDRESSES THE CURRENT WEBSITE URL CAN BE
OBTAINED BY E-MAILING DLGR_NSWC_FOWEB@NAVY.MIL WITH THE SUBJECT LINE
“WEBSITE URL REQUEST”. AN AUTOMATED REPLY WILL CONTAIN THE CURRENT WEB
ADDRESS.
1.4 SUBSTITUTION OF PIECES OR ITEMS IS NOT AUTHORIZED WITHOUT APPROVAL OF THE
APPROVING ACTIVITY, NAVAL SURFACE WARFARE CENTER, DAHLGREN DIVISION,
FIBER OPTICS SECTION.
1.5 THESE ITEMS ARE TO BE USED IN THE PERFORMANCE OF FIBER OPTIC TESTING AS
SPECIFIED IN THE CURRENT REVISIONS OF REFERENCES 1 AND 2.
1.6 ITEMS NO. 1 THROUGH 4 AND 14 (SEE TABLE I) AND ITEMS 1SME THROUGH 4SME AND
14SME (SEE TABLE II) ARE FOR USE WITH AN OPTICAL TIME DOMAIN REFLECTOMETER
(OTDR).
1.6 ITEMS NO. 5 THROUGH 13 AND 15 THROUGH 16 (SEE TABLE I), AND ITEMS 5SME THROUGH
13SME AND 15SME THORUGH 16SME (SEE TABLE II) ARE FOR USE WITH AN OPTICAL LOSS
TEST SET (OLTS) AND OPTICAL RETURN LOSS (ORL) METERS.
1.7 INDIVIDUAL ITEMS SHALL BE PROCURED USING THE BASIC DRAWING NUMBER FOLLOWED
BY A DASH AND THE ITEM NUMBER FROM TABLE I-II. TABLE III & IV ARE ADDED FOR QUICK
REFERENCE ONLY, USING COMMON LANGUAGE EQUIVALENTS.
1.8 ALL PIECES IDENTIFIED BY THE MILITARY PART NUMBER SHALL BE FROM AN APPROVED
SOURCE OF SUPPLY LISTED ON THE QUALIFIED PRODUCTS LIST (QPL)
(http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-
Shipboard-Fiberoptics/Status-QPLs/) UNLESS OTHERWISE APPROVED BY THE APPROVING
ACTIVITY.
mailto:DLGR_NSWC_FOWEB@NAVY.MIL http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-Shipboard-Fiberoptics/Status-QPLs http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-Shipboard-Fiberoptics/Status-QPLs
SHEET 3
E S
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
SCALE: NONE UCI WT GRP
2. REQUIREMENTS
2.1 THE SHIPBOARD FIBER OPTIC MQJs SHALL MEET THE REQUIREMENTS SPECIFIED HEREIN.
2.2 THE END FACE OF ALL LIGHT DUTY (ST, LC) CONNECTORS, TERMINI PINS AND SOCKETS
ON MQJs, WHEN INSPECTED USING A 400X VIDEO SCOPE, SHALL HAVE NO VISIBLE
SCRATCHES.
2.3 THE SHIPBOARD FIBER OPTIC MQJs SHALL BE TESTED FOR OPTICAL LOSS AND RETURN
LOSS (IF SINGLE MODE) IN ACCORDANCE WITH THE CURRENT REVISION OF REFERENCE 1
AND THIS DOCUMENT.
2.4 SHIPBOARD FIBER OPTIC MQJs WITH MIL-C-28876 PLUGS OR RECEPTACLES KEYED WITH
ONLY THE MASTER KEY SHALL BE VISIBLY MARKED WITH THE FOLLOWING:
WARNING
SPECIAL MEASUREMENT QUALITY JUMPER
VISUALLY VERIFY PROPER KEY ALIGNMENT
BEFORE ENGAGING WITH MATING CONNECTORS.
2.5 ALL SHIPBOARD FIBER OPTIC MQJs SHALL BE VISIBLY MARKED WITH THE FOLLOWING:
FIBER OPTIC MEASUREMENT QUALITY
JUMPER CABLE
2.6 FOR ITEMS TERMINATED WITH MIL-S-24623/4-01 SPLICES, THE CABLE SHALL BE STRAIN
RELIEVED TO THE SPLICE USING ADHESIVE LINED HEAT SHRINK TUBING. CABLE
STRENGTH MEMBERS SHALL BE PLACED AROUND THE REAR OF THE SPLICE BEFORE THE
HEAT SHRINK TUBING IS APPLIED.
2.7 CONNECTORS ASSEMBLED USING COLOR CODED SINGLE FIBER CABLING SHALL ASSIGN
THE SINGLE FIBER CABLES TO TERMINI AS FOLLOWS: 1 – BLUE, 2 – ORANGE, 3 – GREEN,
4 – BROWN, 5 – GRAY, 6 – WHITE, 7 – RED, 8 – BLACK. FOR CONNECTORS ASSEMBLED
USING SAME COLOR SINGLE FIBER CABLING, THE SINGLE FIBER CABLING SHALL BE
MARKED WITH THE CORRESPONDING TERMINUS NUMBER.
2.8 MULTIFIBER MQJ CABLES SHALL HAVE 18 +/- 1 INCHES OF SINGLE FIBER CABLE EXPOSED
AT THE END OF THE JUMPER CABLE TERMINATED WITH SINGLE FIBER CONNECTORS.
2.9 MULTIFIBER MQJ CABLES CONSTRUCTED USING M85045/16 SINGLE FIBER CABLE SHALL
INCLUDE A STRAIN RELIEF MECHANISM AT THE POINT OF TRANSITION FROM THE
PROTECTIVE TUBING TO THE UNPROTECTED M85045/16 SINGLE FIBER CABLE.
2.10 CONNECTOR PARTS IDENTIFIED FOR SINGLE MODE MQJ CABLES MAY BE UTILIZED IN THE
CONSTRUCTION OF MULTIMODE JUMPER CABLES.
SHEET 4
E S
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP
2.11 END CONNECTIONS ON MULTIMODE MQJ CABLES SHALL MEET THE FOLLOWING LOSS
REQUIREMENTS:
EACH M29504/14 or M29504/15 TERMINUS SHALL HAVE A MEAN OPTICAL LOSS OF < 0.70 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB. EACH LIGHT DUTY TYPE CONNECTOR SHALL HAVE A MEAN OPTICAL LOSS OF < 0.35 dB AND A MAXIMUM STANDARD DEVIATION:
OF 0.05 dB. EACH M24623/4-01 SHALL HAVE A MEAN OPTICAL LOSS OF < 0.30 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB.
2.12 END CONNECTIONS ON SINGLE MODE MEASUREMENT QUALITY JUMPER CABLES SHALL
MEET THE FOLLOWING LOSS REQUIREMENTS:
EACH M29504/14 or M29504/15 TERMINUS SHALL HAVE A MEAN OPTICAL LOSS OF < 0.70 dB AND A MAXIMUM STANDARD DEVIATION OF 0.10 dB. EACH LIGHT DUTY TYPE CONNECTOR SHALL HAVE A MEAN OPTICAL LOSS OF < 0.35 dB AND A MAXIMUM STANDARD DEVIATION:
OF 0.10 dB. EACH M24623/4-01 SHALL HAVE A MEAN OPTICAL LOSS OF < 0.30 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB.
2.13 END CONNECTIONS ON SINGLE MODE MQJ CABLES SHALL BE OF ENHANCED
PERFORMANCE AND MEET REFLECTANCE REQUIREMENTS of -43.0 dB OR GREATER
2.14 CONNECTOR AND TERMINUS RETURN LOSS SHALL BE MEASURED IN ACCORDANCE WITH
MIL-STD-1678-2 MEASUREMENT 2105
2.15 END FACE GEOMETRY SHALL BE IN ACCORDANCE WITH MIL-STD-1678-5; MEASUREMENT
5201.1.
2.16 MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-130
3. MQJ CONFIGURATIONS
3.1 MQJs SHALL BE PROVIDED IN ONE OR MORE OF THE FOLLOWING CONFIGURATIONS
SPECIFIED IN TABLE I/III FOR MULTIMODE MQJs AND TABLE II/IV FOR SINGLE MODE MQJs.
3.2 SPECIAL CONFIGURATIONS, NOT SPECIFIED IN TABLES I – IV, MAY BE USED WITH
AUTHORIZED APPROVAL (SEE 1.1) BUT WILL NOT BE CONSIDERED STANDARD. SPECIAL
CONFIGURATIONS WILL NOT BE ADDED TO THE RECOMMENDED TEST EQUIPMENT LIST.
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 5
TABLE I
MULTIMODE FIBER OPTIC MQJ CABLES
ITEM
LENGTH
(M)
CONNECTOR
MILITARY
OR VENDOR
PART NO.
CABLE
MILITARY
OR VENDOR
PART NO.
CONNECTOR
ADAPTER
VENDOR
PART NO.
CONNECTOR
MILITARY
OR VENDOR
PART NO.
TERMINI
MILITARY
OR VENDOR
PART NO.
1 50 A-A-59940/3-
111SN
M85045/16-01 NA
A-A-59940/3-
111SN
NA
2 50 A-A-59940/3-
111SN
M85045/16-01 NA M24623/4-01 NA
3 50 A-A-59940/3-
111SN
M85045/16-01 NA NA M29504/14-4131C
4 50 A-A-59940/3-
111SN
M85045/16-01 NA NA M29504/15-4171C
5 1 A-A-59940/3-
111SN
M85045/16-01 NA
A-A-59940/3-
111SN
NA
6 1 A-A-59940/3-
111SN
M85045/16-01 NA M24623/4-01 NA
7 1 A-A-59940/3-
111SN
M85045/18-01 NA 1145846-B042P0S
M29504/14-4131C M85045/16-01
127-021-1-1-16CKHE
189-014NF13-07 4565143-B04P0S
8 1 A-A-59940/3-
111SN
M85045/18-01 NA 1145840-B042S0S
M29504/15-4171C M85045/16-01
127-021-1-1-16CKHE
189-014NF13-07 4565141-B04S0S
9 1 A-A-59940/3-
111SN
M85045/17-01 NA 1145846-C081P0S
M29504/14-4131C M85045/16-01
127-021-1-1-16CKHE
189-014NF15-07 4565143-C08P0S
10 1 A-A-59940/3-
111SN
M85045/17-01 NA 1145840-C081S0S
M29504/15-4171C M85045/16-01
127-021-1-1-16CKHE
189-014NF15-07 4565141-C08S0S
12 1 A-A-59940/3-
111SN
M85045/16-01
127-021-1-1-32CKHE
189-014NF23-07 4565143-F31P0S M29504/14-4131C
13 1 A-A-59940/3-
111SN
M85045/16-01
127-021-1-1-32CKHE
189-014NF23-07 4565141-F31SOS M29504/15-4171C
14 50 A-A-59940/3-
111SN
M85045/16-01 NA
A-A-59940/1-
111SN
NA
15 1 A-A-59940/3-
111SN
M85045/16-01 NA
A-A-59940/1-
111SN
NA
16 1 A-A-59940/3-
111SN
M85045/16-01 189-014NF11 4565141-A021SOS M29504/15-4171C
SHEET 6
S
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP
TABLE II
SINGLE MODE ENHANCED PERFORMANCE FIBER OPTIC MQJ CABLES
LENGTH
(M)
CONNECTOR
MILITARY
OR VENDOR
PART NO.
CABLE
MILITARY
OR VENDOR
PART NO.
CONNECTOR
ADAPTER
VENDOR
PART NO.
CONNECTOR
MILITARY
OR VENDOR
PART NO.
TERMINI
MILITARY
OR VENDOR
PART NO.
1SME 50
A-A-59940/3-
121SN
M85045/16-02 NA
A-A-59940/3-
121SN
NA
3SME 50
A-A-59940/3-
121SN
M85045/16-02 NA NA M29504/14-4141C
4SME 50
A-A-59940/3-
121SN
M85045/16-02 NA NA M29504/15-4181C
5SME 1
A-A-59940/3-
121SN
M85045/16-02 NA
A-A-59940/3-
121SN
NA
7SME 1
A-A-59940/3-
121SN
M85045/18-02 NA 1145846-B042P0S
M29504/14-4141C M85045/16-02
127-021-1-1-16CKHE
189-014NF13-07 4565143-B04P0S
8SME 1
A-A-59940/3-
121SN
M85045/18-02 NA 1145840-B042S0S
M29504/15-4181C M85045/16-02
127-021-1-1-16CKHE
189-014NF13-07 4565141-B04S0S
9SME 1
A-A-59940/3-
121SN
M85045/17-02 NA 1145846-C081P0S
M29504/14-4141C M85045/16-02
127-021-1-1-16CKHE
189-014NF15-07 4565143-C08P0S
10SME 1
A-A-59940/3-
121SN
M85045/17-02 NA 1145840-C081S0S
M29504/15-4181C M85045/16-02
127-021-1-1-16CKHE
189-014NF15-07 4565141-C08S0S
12SME 1
A-A-59940/3-
121SN
M85045/16-02
127-021-1-1-32CKHE
189-014NF23-07 4565143-F31P0S M29504/14-4141C
13SME 1
A-A-59940/3-
121SN
M85045/16-02
127-021-1-1-32CKHE
189-014NF23-07 4565141-F31SOS M29504/15-4181C
14SME 50
A-A-59940/3-
121SN
M85045/16-02 NA
A-A-59940/1-
121SN
NA
15SME 1
A-A-59940/3-
121SN
M85045/16-02 NA
A-A-59940/1-
121SN
NA
16SME 1
A-A-59940/3-
121SN
M85045/16-02 189-014F11 4565141-A021SOS M29504/15-4181C
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 7
TABLE III
MM MQJ QUICK REFERENCE
LENGTH
(M)
CONNECTOR
CABLE
MILITARY
OR VENDOR
PART NO.
CONNECTOR
ADAPTER
VENDOR
PART NO.
CONNECTOR
TERMINI
MILITARY
OR
VENDOR
PART NO.
1 50 ST
SINGLE FIBER
TIGHT BUFFER MM
NA ST NA
2 50 ST
SINGLE FIBER
TIGHT BUFFER MM
NA
ROTARY
MECHANICAL SPLICE
NA
3 50 ST
SINGLE FIBER
TIGHT BUFFER MM
NA NA PIN*
4 50 ST
SINGLE FIBER
TIGHT BUFFER MM
NA NA SOCKET*
5 1 ST
SINGLE FIBER
TIGHT BUFFER MM
NA ST NA
6 1 ST
SINGLE FIBER
TIGHT BUFFER MM
NA
ROTARY
MECHANICAL SPLICE
NA
7 1 ST
FOUR FIBERS
SHIPBOARD MM
NA
UNIVERSAL SHELL
SIZE 13 PLUG
CONNECTOR -
CONVENTIONAL PIN*
SINGLE FIBER
TIGHT BUFFER MM
(4 EA)
SHELL SIZE 13
ADAPTER
UNIVERSAL SHELL SIZE
13 PLUG CONNECTOR -
CONDUIT
8 1 ST
FOUR FIBERS
SHIPBOARD MM
NA
UNIVERSAL SHELL SIZE
13 RECEPTACLE
CONNECTOR -
CONVENTIONAL SOCKET*
SINGLE FIBER
TIGHT BUFFER MM
(4 EA)
SHELL SIZE 13
ADAPTER
UNIVERSAL SHELL SIZE
13 RECEPTACLE
CONNECTOR - CONDUIT
9 1 ST
EIGHT FIBERS
SHIPBOARD MM
NA
UNIVERSAL SHELL SIZE
15 PLUG CONNECTOR -
CONVENTIONAL
PIN*
SINGLE FIBER
TIGHT BUFFER MM
(8 EA)
SHELL SIZE 15
ADAPTER
UNIVERSAL SHELL SIZE
15 PLUG CONNECTOR -
CONDUIT
10 1 ST
EIGHT FIBERS
SHIPBOARD MM
NA
UNIVERSAL SHELL SIZE
15 RECEPTACLE
CONNECTOR -
CONVENTIONAL SOCKET*
SINGLE FIBER
TIGHT BUFFER MM
(8 EA)
SHELL SIZE 15
ADAPTER
UNIVERSAL SHELL SIZE
15 RECEPTACLE
CONNECTOR - CONDUIT
12 1 ST
SINGLE FIBER
TIGHT BUFFER MM
(31 EA)
SHELL SIZE 23
ADAPTER
UNIVERSAL SHELL SIZE
23 PLUG CONNECTOR -
CONVENTIONAL
PIN*
13 1 ST
SINGLE FIBER
TIGHT BUFFER MM
(31 EA)
SHELL SIZE 23
ADAPTER
UNIVERSAL SHELL SIZE
23 RECEPTACLE
CONNECTOR -
CONVENTIONAL
SOCKET*
14 50 ST
SINGLE FIBER
TIGHT BUFFER MM
NA LC NA
15 1 ST
SINGLE FIBER
TIGHT BUFFER MM
NA LC NA
16 1 ST
SINGLE FIBER
TIGHT BUFFER MM
(2 EA)
SHELL SIZE 11
ADAPTER
UNIVERSAL SHELL SIZE
11 PLUG CONNECTOR -
CONVENTIONAL
SOCKET*
* LONG LENGTH, CERAMIC GUIDE BUSHING, MM, W/ CRIMP SLEEVE, FOR MIL-PRF-28876 CONNECTORS
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 8
TABLE IV
SME MQJ QUICK REFERENCE
LENGTH
(M)
CABLE
ADAPTER
CONNECTOR
TERMINI
MILITARY
OR
VENDOR
PART NO.
1SME 50 ST
SINGLE FIBER
TIGHT BUFFER SM
NA ST NA
3SME 50 ST
SINGLE FIBER
TIGHT BUFFER SM
NA NA PIN*
4SME 50 ST
SINGLE FIBER
TIGHT BUFFER SM
NA NA SOCKET*
5SME 1 ST
SINGLE FIBER
TIGHT BUFFER SM
NA ST NA
7SME 1 ST
FOUR FIBERS
SHIPBOARD SM
NA
UNIVERSAL SHELL SIZE
13 PLUG CONNECTOR -
CONVENTIONAL
PIN*
SINGLE FIBER
TIGHT BUFFER SM
(4 EA)
SHELL SIZE 13
ADAPTER
UNIVERSAL SHELL SIZE
13 PLUG CONNECTOR -
CONDUIT
8SME 1 ST
FOUR FIBERS
SHIPBOARD SM
NA
UNIVERSAL SHELL SIZE
13 RECEPTACLE
CONNECTOR -
CONVENTIONAL SOCKET*
SINGLE FIBER
TIGHT BUFFER SM
(4 EA)
SHELL SIZE 13
ADAPTER
UNIVERSAL SHELL SIZE
13 RECEPTACLE
CONNECTOR - CONDUIT
9SME 1 ST
EIGHT FIBERS
SHIPBOARD SM
NA
UNIVERSAL SHELL SIZE
15 PLUG CONNECTOR -
CONVENTIONAL
PIN*
SINGLE FIBER
TIGHT BUFFER SM
(8 EA)
SHELL SIZE 15
ADAPTER
UNIVERSAL SHELL SIZE
15 PLUG CONNECTOR -
CONDUIT
10SME 1 ST
EIGHT FIBERS
SHIPBOARD SM
NA
UNIVERSAL SHELL SIZE
15 RECEPTACLE
CONNECTOR -
CONVENTIONAL SOCKET*
SINGLE FIBER
TIGHT BUFFER SM
(8 EA)
SHELL SIZE 15
ADAPTER
UNIVERSAL SHELL SIZE
15 RECEPTACLE
CONNECTOR - CONDUIT
12SME 1 ST
SINGLE FIBER
TIGHT BUFFER SM
(31 EA)
SHELL SIZE 23
ADAPTER
UNIVERSAL SHELL SIZE
23 PLUG CONNECTOR -
CONVENTIONAL
PIN*
13SME 1 ST
SINGLE FIBER
TIGHT BUFFER SM
(31 EA)
SHELL SIZE 23
ADAPTER
UNIVERSAL SHELL SIZE
23 RECEPTACLE
CONNECTOR -
CONVENTIONAL
SOCKET*
14SME 50 ST
SINGLE FIBER
TIGHT BUFFER SM
NA LC NA
15SME 1 ST
SINGLE FIBER
TIGHT BUFFER SM
NA LC NA
16SME 1 ST
SINGLE FIBER
TIGHT BUFFER SM
(2 EA)
SHELL SIZE 11
ADAPTER
UNIVERSAL SHELL SIZE
11 PLUG CONNECTOR
CONVENTIONAL
SOCKET*
* LONG LENGTH, CERAMIC GUIDE BUSHING, SM, W/ CRIMP SLEEVE, FOR MIL-PRF-28876 CONNECTORS
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 9
4. VERIFICATION OF REQUIREMENTS
4.1 UNLESS OTHERWISE SPECIFIED BY THE PROCURING ACTIVITY THE SUPPLIER IS
RESPONSIBLE FOR THE PERFORMANCE OF ALL ITEMS CONTAINED HEREIN WITH REGARD
TO THE ABOVE REQUIREMENTS. TEST DATA MAY BE PROVIDED TO DEMONSTRATE
PERFORMANCE, HOWEVER THE PROCURING ACTIVITY RESERVES THE RIGHT TO PERFORM
ANY OF THE INSPECTIONS SPECIFIED. TEST SAMPLES SHALL BE SUBMITTED TO THE
APPROVING ACTIVITY.
4.2 END FACE GEOMETRY DATA WILL ONLY BE PROVIDED IF REQUESTED WHEN ORDERING.
5. EVALUATION PROCESS FOR APPROVAL OF MEASUREMENT QUALITY JUMPERS (MQJs)
5.1 THE PROCESS FOR EVALUATION AND APPROVAL OF MQJs DEVELOPED IN ACCORDANCE
WITH NAVSEA DRAWING 6877804 IS DESCRIBED HEREIN.
5.2 PREFERRED PROCESS
5.2.1 ORGANIZATIONS SEEKING APPROVAL FOR THEIR MQJs MUST CONTACT, IN WRITING, NSWCDD, AT DLGR_NSWC_FO_ENG@NAVY.MIL REQUESTING THE APPROVAL OF THEIR
MQJs. NSWCDD WILL CONTACT THE ORGANIZATION SEEKING APPROVAL AND PROVIDE
GUIDANCE ON HOW TO PROCEED THROUGH THE PROCESS.
5.2.2 ORGANIZATION SEEKING APPROVAL PROVIDES MQJ CANDIDATES (SEE 5.3 FOR
REQUIRED SUBMISSIONS) OR AS DIRECTED BY NSWCDD.
5.2.3 NSWCDD VERIFIES THAT THE PRODUCTS PASS THE REQUIREMENTS HEREIN (SEE SECTION
2 AND APPENDIX A).
5.2.4 UPON SUCCESSFULLY COMPLETING THE PROCESS, NSWCDD WILL CONTACT THE
ORGANIZATION SEEKING APPROVAL AND NOTIFY THEM OF THE RESULTS VIA EMAIL. THE
PARTS THAT HAVE OBTAINED FULL APPROVAL (SEE TABLE V OR TABLE VI) WILL BE ADDED
TO THE RECOMMENDED TEST EQUIPMENT LIST WHICH IS PUBLISHED ON THE NSWCDD
FIBER OPTIC WEBSITE.
5.2.5 INTERIM APPROVED MQJs (SEE TABLE V OR TABLE VI) WILL NOT APPEAR ON THE
RECOMMENDED TEST EQUIPMENT LIST. TO OBTAIN FULL APPROVAL FOR AN INTERIM
APPROVED MQJ THE ORGANIZATION SHALL, UPON FIRST SALE OF AN INTERIM APPROVED
MQJ, SEND A COPY OF THE FOLLOWING DATA FOR THE MQJ TO THE APPROVING ACTIVITY:
INSERTION LOSS, RETURN LOSS (IF SINGLE MODE), INTERFEROMETER MEASUREMENTS,
AND THE CUSTOMER’S POC INFORMATION. IF THE DATA INDICATES PASSING RESULTS
AND THE CUSTOMER IS SATISFIED WITH THE PRODUCT, THE ORGANIZATION WILL THEN
RECEIVE FULL APPROVAL FOR THAT PRODUCT AND THE PRODUCT WILL BE ADDED TO THE
RECOMMENDED TEST EQUIPMENT LIST.
5.2.6 FOR CHANGES IN MQJ PRODUCT OR MANUACTURING PROCESS AFTER APPROVAL
CONTACT NSWCDD (SEE 5.4)
5.3. REQUIRED SAMPLE MQJ SUBMISSIONS
mailto:DLGR_NSWC_FO_ENG@NAVY.MIL
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 10
5.3.1 REQUIRED SAMPLES FOR ST TO LC MQJs. THE REQUESTING ORGANIZATION SHALL SUPPLY
NAVSEA DRAWING 6877804 ITEM NUMBERS 15 AND 15SME FOR EVALUATION. OPTICAL
LOSS AND OPTICAL RETURN LOSS DATA (SM ONLY) ALONG WITH INTERFEROMETER DATA
SHALL BE PROVIDED FOR EACH OF THE SAMPLES SUBMITTED. NSWCDD WILL THEN VERIFY
THAT THE PRODUCTS PASS THE REQUIREMENTS WITHIN NAVSEA DRAWING 6877804. UPON
PASSING REQUIREMENTS, THE ORGANIZATION WILL BE GRANTED THE MANUFACTURING
AND SALE APPROVALS AS SHOWN IN TABLE VI.
5.3.2 REQUIRED SAMPLES FOR ALL OTHER MQJ TYPES. THE REQUESTING ORGANIZATION
SHALL PROVIDE NAVSEA DRAWING 6877804 ITEM NUMBERS: 7, 8, 12SME, AND 13SME
ALONG WITH TWO 1 METER MM LEADS WITH M29504/14 ON ONE END AND M29504/15 ON
THE OTHER END, AND TWO 1 METER SM LEADS WITH SME POLISHED M29504/14 ON ONE
END AND SME POLISHED M29504/15 ON THE OTHER END TO NSWCDD FOR EVALUATION.
OPTICAL LOSS AND OPTICAL RETURN LOSS DATA (SM ONLY) ALONG WITH
INTERFEROMETER DATA SHALL BE PROVIDED FOR EACH OF THE SAMPLES SUBMITTED.
NSWCDD WILL THEN VERIFY THAT THE PRODUCTS PASS THE REQUIREMENTS WITHIN
NAVSEA DRAWING 6877804. UPON PASSING REQUIREMENTS, THE REQUESTING
ORGANIZATION WILL BE GRANTED THE MANUFACTURING AND SALE APPROVALS AS
SHOWN IN TABLE VI.
TABLE V - FULL AND INTERIM APPROVAL (ST, M29504/14, M29504/15, M28876 PLUG AND
RECEPTACLE)
ITEM NUMBER APPROVAL STATUS /1 /2
12SME FULL APPROVAL
13SME FULL APPROVAL
7 FULL APPROVAL
8 FULL APPROVAL
1 INTERIM APPROVAL
3 INTERIM APPROVAL
4 INTERIM APPROVAL
5 INTERIM APPROVAL
9 INTERIM APPROVAL
10 INTERIM APPROVAL
12 INTERIM APPROVAL
13 INTERIM APPROVAL
16 INTERIM APPROVAL
1SME INTERIM APPROVAL
3SME INTERIM APPROVAL
4SME INTERIM APPROVAL
5SME INTERIM APPROVAL
7SME INTERIM APPROVAL
8SME INTERIM APPROVAL
9SME INTERIM APPROVAL
10SME INTERIM APPROVAL
16SME INTERIM APPROVAL
/1 TABLE V PROVIDES DIRECTION FOR ORGANIZATIONS LOOKING TO OBTAIN
APPROVAL TO MANUFACTURE AND SELL SM AND MM MQJs IN ACCORDANCE
WITH NAVSEA DRAWING 6877804.
/2 IF THE REQUESTING ORGANIZATION ONLY WANTS APPROVAL TO MANUFACTURE
AND SELL SPECIFIC ITEMS IN TABLE V, THE ORGANIZATION MUST CONTACT THE
FIBER OPTIC TECHNOLOGY SECTION (DLGR_NSWC_FO_ENG@NAVY.MIL) TO
DISCUSS OTHER OPTIONS FOR THE APPROVAL TO MANUFACTURE AND SELL
THOSE ITEMS.
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 11
TABLE VI - FULL AND INTERIM APPROVAL (ST to LC MQJs)
NAVSEA DRAWING
6877804 ITEM NUMBER
QUANTITY
APPROVAL STATUS
/1 /2
15SME 15 FULL APPROVAL
15 5 FULL APPROVAL
14SME N/A INTERIM APPROVAL
14 N/A INTERIM APPROVAL
/1 TABLE VI PROVIDES DIRECTION FOR ORGANIZATIONS LOOKING TO OBTAIN APPROVAL
TO MANUFACTURE AND SELL ST TO LC SM AND MM MQJs IN ACCORDANCE WITH
NAVSEA DRAWING 6877804.
/2 IF THE REQUESTING ORGANIZATION ONLY WANTS APPROVAL TO MANUFACTURE AND
SELL SPECIFIC ITEMS IN TABLE VI, THE ORGANIZATION MUST CONTACT THE FIBER
OPTIC TECHNOLOGY SECTION (DLGR_NSWC_FO_ENG@NAVY.MIL) TO DISCUSS OTHER
OPTIONS FOR THE APPROVAL TO MANUFACTURE AND SELL THOSE ITEMS.
5.4 ALTERNATE APPROVAL PROCESS. REQUESTING ORGANIZATIONS THAT DO NOT WISH TO
FOLLOW THE PREFERRED PROCESS MUST CONTACT NSWCDD AT
DLGR_NSWC_FO_ENG@NAVY.MIL WITH A REQUEST ON WHAT SUBSET OF MQJs FOR WHICH
THEY ARE SEEKING APPROVAL. NSWCDD WILL THEN WORK WITH THE REQUESTING
ORGANIZATION TO DEFINE THE REQUIRED SAMPLE SET FOR EVALUATION.
5.5 CHANGES IN MANUFACTURING PROCESSES. IF THE ORGANIZATION MAKES ANY CHANGES TO
ITS MANUFACTURING PROCESS (E.G. CHANGE FACILITIES, CONTRACTORS, ETC.) THEY SHALL
NOTIFY NSWCDD, AT DLGR_NSWC_FO_ENG@NAVY.MILOF THE CHANGE. NSWCDD RESERVES
THE RIGHT TO CANCEL THE ORGANIZATION’S APPROVAL IF THEY BELIEVE THE CHANGE CAN
BE DETRIMENTAL TO THE QUALITY OF THE MQJ OR TO REQUEST RE-EVALUATION OF THE
MQJs.
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 12
APPENDIX A
EVALUATION OF MEASUREMENT QUALITY JUMPERS
A.1 VISUAL INSPECTION AND ENDFACE GEOMETRY
a. TAKE SEVERAL PICTURES OF THE MQJs UNDER TEST AT DIFFERENT ANGLES.
b. COMPARE MQJs UNDER TEST WITH NAVSEA DRAWING 6877804 AND NOTE ANY
DIFFERENCES.
c. INSPECT PHYSICAL CONSTRUCTION OF MQJs FOR QUALITY OF WORKMANSHIP AND
COMMENT.
d. VISUALLY INSPECT ALL LIGHT DUTY CONNECTORS, TERMINI PINS AND SOCKETS ON
MQJs AND COMMENT ON WORKMANSHIP. THE FIBER OPTIC SECTION USES A 400X
VIDEO SCOPE WITH A BLUE LIGHT TO VIEW CONNECTOR AND TERMINI END FACES. IN
ORDER TO PASS THE INSPECTION, THERE SHALL BE NO VISIBLE SCRATCHES
OBSERVED WHEN USING THE VIDEO SCOPE.
e. CHECK ALL LIGHT DUTY CONNECTOR ENDFACES OF MQJs USING THE
INTERFEROMETER AND PRINT COPIES OF THE MEASUREMENTS. THE REQUESTING
ORGANIZATION SHALL SUPPLY COPIES OF THE INTERFEROMETER MEASUREMENTS
OF ALL SAMPLES SUBMITTED. CONNECTORS SHALL MEET GR-326 CRITERIA FOR
DOMED PHYSICAL CONTACT CONNECTORS. THE FOLLOWING IS THE CRITERIA:
i. RADIUS OF CURVATURE (ROC) SHALL BE BETWEEN 7MM AND 25 MM
ii. APEX OFFSET OF THE SPHERICAL ENDFACE TO THE AXIS OF THE FERRULE SHALL
BE LESS THAN 50 MICROMETERS
iii. FIBER PROTRUSION SHALL NOT EXCEED 50 NM; WHEN ROC IS 25 MM, FIBER
UNDERCUT SHALL BE NO MORE THAN 50 NM. FOR ALL OTHER ROC VALUES THE
MAXIMUM UNDERCUT IS GIVEN IN TABLE A-I.
TABLE A-I – MAXIMUM UNDERCUT ALLOWANCE
ROC (mm) 7 8 9 10 11 12
Undercut(nm) 125 125 125 125 115 106
ROC (mm) 13 14 15 16 17 18
Undercut(nm) 98 91 85 80 75 72
ROC (mm) 19 20 21 22 23 24
Undercut(nm) 68 65 62 59 56 53
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 13
A.2 OPTICAL INSERTION LOSS MEASUREMENTS
NOTE: FOR SINGLE MODE FIBER MEASUREMENTS, THE REFERENCE CABLE MAY INCLUDE A
SINGLE LOOP WITH A DIAMETER OF 30 MILLIMETERS (1 INCH) TO ELIMINATE HIGHER
ORDER MODE POWER.
NOTE: THE TIME DELAY BETWEEN THE MEASUREMENT OF P1 AND P2 SHALL BE KEPT TO A
MINIMUM TO PREVENT INACCURATE READINGS.
NOTE: THE REFERENCE CABLE TO LIGHT SOURCE CONNECTION SHALL NOT BE DISTURBED
BETWEEN THE MEASUREMENT OF P1 AND P2 TO PREVENT INACCURATE READINGS.
NOTE: A WIPE DAMPENED WITH ALCOHOL MAY BE USED TO CLEAN THE ADAPTERS AND
CONNECTORS AND THEY MAY BE BLOWN DRY WITH AIR BEFORE MAKING EACH
CONNECTION.
NOTE: THIS PROCEDURE INVOLVES THE USE OF REFERENCE MQJs. DEFECTIVE OR DIRTY
MQJs WILL LEAD TO UNACCEPTABLE LOSS VALUES. THE REFERENCE MQJ SHOULD BE
CLEAN AND OF KNOWN QUALITY.
TABLE A-II – SUMMARY OF PASS/FAIL CRITERIA
Test performed Pass/Fail criteria
Evaluate workmanship See evaluation process for details
Visual exam See evaluation process for details
Interferometer measurements GR-326 criteria for multimode and single mode
Insertion loss of ST and LC connectors
Mean: 0.35 dB Standard deviation multimode: 0.05 max Standard deviation single mode: 0.10 max
Insertion loss of termini (M29504/14 or M29504/15)
Mean: 0.7 dB Standard Deviation multimode: 0.05 max Standard Deviation single mode: 0.10 max
Return loss (Single Mode Only) 43 dB or better
A.2.1 ST-TO-LIGHT DUTY CONNECTOR (ST OR LC) MQJs:
A.2.1.1 MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR ENDS AS FOLLOWS (SEE FIGURES
A-1 AND A-2 BELOW)
a. REFERENCE MEASUREMENT (P1)
i. SELECT AN MQJ REFERENCE CABLE
NOTE: SELECT AN MQJ THAT COMPLIES WITH MIL-STD-2042-6C METHOD 6F1: MQJ
CABLE SELECTION TEST
ii. CONNECT END “A” (ST) OF THE ST TO LIGHT DUTY CONNECTOR (ST/LC)
REFERENCE MQJ TO THE LIGHT SOURCE
iii. CONNECT END “B” (ST OR LC) OF THE ST TO LIGHT DUTY CONNECTOR (ST/LC)
REFERENCE MQJ TO THE POWER METER
iv. RECORD THE OPTICAL POWER AT THE METER AS P1 (SEE FIGURE A-1)
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
SCALE: NONE UCI WT GRP SHEET 14
b. TEST MEASUREMENT (P2)
i. DISCONNECT END “B” OF THE REFERENCE MQJ FROM THE POWER METER
ii. CONNECT END “B” OF THE REFERENCE MQJ TO A ST-TO-ST OR LC-TO-LC ADAPTER
iii. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-TO-ST OR LC–TO-LC
ADAPTER
iv. CONNECT END “B” OF THE MQJ UNDER TEST TO THE OPPOSITE END OF THE MQJ
UNDER TEST TO THE POWER METER
v. RECORD THE OPTICAL POWER AS P2 (SEE FIGURE A-2)
c. CALCULATE THE LIGHT DUTY CONNECTOR (ST/LC) CONNECTOR, OF THE MQJ UNDER
TEST, END “A” OPTICAL LOSS AS P1- P2
d. RECORD THE OPTICAL LOSS VALUE
e. MEASURE THE OPTICAL LOSS OF THE LIGHT DUTY CONNECTOR (ST/LC) CONNECTOR A
MINIMUM OF TWO ADDITIONAL TIMES (MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND
MATE THE ST CONNECTORS (REFERENCE MQJ LIGHT DUTY CONNECTOR (ST/LC) AND
MQJ UNDER TEST LIGHT DUTY CONNECTOR (ST/LC)) BETWEEN EACH MEASUREMENT.
NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING.
f. THE LIGHT DUTY CONNECTOR (ST/LC) OF THE MQJ UNDER TEST IS ACCEPTABLE IF
THE AVERAGE OF THE OPTICAL LOSS MEASUREMENTS IS < 0.35 DB AND THE
STANDARD DEVIATION IS 0.05 OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE
MODE. NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.35 DB.
g. REPEAT PROCEDURE TO MEASURE THE CONNECTOR LOSS ON THE OTHER END OF
THE MQJ UNDER TEST
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
SCALE: NONE UCI WT GRP SHEET 15
FIGURE A-1 - REFERENCE MEASUREMENT (P1)
FIGURE A-2 - TEST MEASUREMENT (P2)
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 16
A.2.2 ST-TO-MULTI-TERMINUS CONNECTOR MQJs
A.2.2.1 MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR ENDS AS FOLLOWS
i. CONNECT END “A” (ST CONNECTOR END) OF THE REFERENCE MQJ (DESIGNATED
MQJ 2) TO THE OPTICAL SOURCE.
NOTE: METHOD IS WRITTEN FOR MQJ UNDER TEST BEING A PLUG MQJ. IF MQJ UNDER TEST
IS A RECEPTACLE MQJ THEN THE REFERENCE MQJ WILL NEED TO SWITCH TO A PLUG
MQJ.
ii. CONNECT END “B” OF MQJ 2, THE END OPPOSITE THE LIGHT SOURCE, TO END “B”
(MULTI-TERMINUS END) OF THE MQJ UNDER TEST
iii. CONNECT END “A” (ST END) OF THE MQJ UNDER TEST TO THE POWER METER
iv. RECORD THE OPTICAL POWER AS P1 (SEE FIGURE A-3)
b. TEST MEASUREMENT (P2)
i. DISCONNECT END “A” OF THE MQJ UNDER TEST FROM THE POWER METER
ii. CONNECT END “A” (ST CONNECTOR END) OF THE MQJ UNDER TEST TO A ST-TO-ST
ADAPTER
iii. CONNECT END “A” OF MQJ 1 (REFERENCE ST-TO-ST MQJ) TO THE ST-TO-ST
ADAPTER
iv. CONNECT THE OPPOSITE END OF MQJ 1 TO THE POWER METER
v. RECORD THE OPTICAL POWER AS P2 (SEE FIGURE A-4)
c. CALCULATE THE ST CONNECTOR OPTICAL LOSS AS P1- P2
d. RECORD THE OPTICAL LOSS VALUE
e. MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR A MINIMUM OF TWO
ADDITIONAL TIMES (MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND MATE THE ST
CONNECTORS (MQJ 1 ST AND MQJ UNDER TEST ST) BETWEEN EACH MEASUREMENT.
NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING
f. THE ST CONNECTOR OF THE MQJ UNDER TEST IS ACCEPTABLE IF THE AVERAGE OF
THE OPTICAL LOSS MEASUREMENTS IS < 0.35 DB AND THE STANDARD DEVIATION IS
0.05 OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE MODE.
NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.35 DB
g. REPEAT STEPS ‘A’ THROUGH ‘F’ FOR EACH CHANNEL OF THE MQJ
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
SCALE: NONE UCI WT GRP SHEET 17
FIGURE A-3 - REFERENCE MEASUREMENT (P1)
1. LIGHT SOURCE (MM – USE LED SOURCE, SM – USE LASER)
2. MQJ 2 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM, SM – USE
SME MQJ)
3. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)
4. POWER METER
FIGURE A-4 - TEST MEASUREMENT (P2)
1. LIGHT SOURCE (MM- USE LED SOURCE, SM – USE LASER)
2. MQJ 2 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM, SM – USE
SME MQJ)
3. POWER METER
4. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)
5. MQJ 1 = ST TO ST REFERENCE MQJ (MM-USE MM, SM- USE SME MQJ)
A.2.3 MEASURE THE OPTICAL LOSS OF THE TERMINI
NOTE: THIS MEASUREMENT IS DONE OVER THE TERMINUS INTERFACE AT END “B” OF THE MQJ
UNDER TEST
NOTE: THIS MEASUREMENT INVOLVES A SUBSTITUTION OF THE MQJ FROM THE REFERENCE
MEASUREMENT TO THE TEST MEASUREMENT
NOTE: THIS METHOD IS WRITTEN FOR THE MQJ UNDER TEST BEING A PLUG MQJ. IF THE MQJ
UNDER TEST IS A RECEPTACLE MQJ THEN THE REFERENCE MQJ WILL NEED TO SWITCH TO
A PLUG MQJ.
i. CONNECT TWO REFERENCE ST-TO-ST MQJs (DESIGNATED MQJ 1 AND MQJ 2)
BETWEEN THE LIGHT SOURCE AND POWER METER. (SEE FIGURE A-5)
ii. RECORD THE OPTICAL POWER AS P1
b. TEST MEASUREMENT (P2)
i. DISCONNECT MQJ 2 FROM MQJ 1 AND THE POWER METER
ii. CONNECT END “A” (ST CONNECTOR END) OF A REFERENCE MQJ (DESIGNATED MQJ
3) TO MQJ 1, THE END OPPOSITE THE LIGHT SOURCE. (SEE FIGURE A-6)
End B End A
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 18
iii. CONNECT END “B” OF MQJ 3, THE END OPPOSITE THE LIGHT SOURCE, TO END “B”
OF THE MQJ UNDER TEST. (SEE FIGURE A-6)
iv. CONNECT END “A” (ST END) OF THE MQJ UNDER TEST TO THE POWER METER (SEE
FIGURE A-6)
v. RECORD THE OPTICAL POWER AS P2
c. CALCULATE THE OPTICAL LOSS AS P1- P2
d. RECORD THE OPTICAL LOSS VALUE
e. MEASURE THE OPTICAL LOSS OF THE TERMINI A MINIMUM OF TWO ADDITIONAL TIMES
(MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND MATE THE TERMINI (ASSEMBLY) (MQJ 3
AND MQJ UNDER TEST ST) BETWEEN EACH MEASUREMENT.
NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING
f. THE TERMINI OF THE MQJ UNDER TEST IS ACCEPTABLE IF THE AVERAGE OF THE
OPTICAL LOSS MEASUREMENTS IS < 0.70 DB AND THE STANDARD DEVIATION IS 0.05
OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE MODE
NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.70 DB
g. REPEAT STEPS A THROUGH F FOR EACH CHANNEL OF THE MQJ
h. REPEAT PROCEDURE WITH THE RECEPTACLE AS THE MQJ UNDER TEST AND MQJ
PLUG AS MQJ 3
FIGURE A-5 - REFERENCE MEASUREMENT (P1)
1. LIGHT SOURCE (MM-USE LED, SM – USE LASER)
2. MQJ 1 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)
3. POWER METER
4. ST TO ST ADAPTER
5. MQJ 2 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)
FIGURE A-6 - TEST MEASUREMENT (P2)
1. LIGHT SOURCE (MM-USE LED, SM – USE LASER)
2. MQJ 3 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM MQJ,
SM – USE SME MQJ)
3. POWER METER
4. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)
5. MQJ 1 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 19
TABLE A-4 - MQJ OPTICAL LOSS ACCEPTANCE CRITERIA
END CONNECTION ACCEPTABLE LOSS (DB)
1/
STANDARD DEVIATION
(DB)
ST 0.00 < ΜC < 0.35
0.05 MAX. (MULTIMODE)
0.10 MAX. (SINGLE MODE)
LC 0.00 < ΜC < 0.35
0.05 MAX. (MULTIMODE)
0.10 MAX. (SINGLE MODE)
M29504/14 PIN TERMINUS 0.00 < ΜC < 0.70
0.05 MAX. (MULTIMODE)
0.10 MAX. (SINGLE MODE)
M29504/15 SOCKET TERMINUS 0.00 < ΜC < 0.70
0.05 MAX. (MULTIMODE)
0.10 MAX. (SINGLE MODE)
1/ WHERE ΜC IS THE MEAN CONNECTION LOSS
A.3 OPTICAL RETURN LOSS MEASURING
NOTE: OPTICAL RETURN LOSS TESTING IS ONLY PERFORMED ON SINGLE MODE MQJs
NOTE: USE ENHANCED DOME POLISH REFERENCE MQJs WITH RETURN LOSS
REQUIREMENTS NOT LESS THAN 43 DB
A.3.1 ST-TO-LIGHT DUTY (ST OR LC) CONNECTOR MQJs
NOTE: SELECT THE 1310 NANOMETER WAVELENGTH IF THE ORLM CAN PERFORM RETURN LOSS
MEASUREMENTS AT MULTIPLE WAVELENGTHS
a. REFERENCE THE ORLM
b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ
FROM THE MANDREL
c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9
d. CONNECT END “B”, END OPPOSITE ORLM, OF THE REFERENCE MQJ TO A ST-ST OR
LC-TO-LC ADAPTER
e. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-ST OR LC-TO-LC ADAPTER
f. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, BEHIND THE ST MATED
PAIR, AND RECORD THE DATA
NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A STABLE
VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE USUALLY
SUFFICIENT TO OBTAIN A STABLE VALUE.
g. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB
h. REPEAT STEPS ‘E’ THRU ‘F’ WITH END “B” OF THE MQJ UNDER TEST CONNECTED TO
THE ST END OF THE REFERENCE MQJ
A.3.2 ST-TO-MULTI-TERMINUS CONNECTOR MQJs
NOTE: SELECT THE 1310 NANOMETER WAVELENGTH IF THE ORLM CAN PERFORM RETURN LOSS
MEASUREMENTS AT MULTIPLE WAVELENGTHS
A.3.2.1 MEASURE THE OPTICAL RETURN LOSS OF THE ST CONNECTOR ENDS
a. REFERENCE THE ORLM
b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ
FROM THE MANDREL
c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9
d. CONNECT END “B”, END OPPOSITE ORLM, OF THE REFERENCE MQJ TO A ST-ST
ADAPTER
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
G
SCALE: NONE UCI WT GRP SHEET 20
e. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-ST ADAPTER
f. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, BEHIND THE ST MATED
PAIR, AND RECORD THE DATA
NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A
STABLE VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE
USUALLY SUFFICIENT TO OBTAIN A STABLE VALUE. REPEAT STEPS “E” THROUGH “F”
FOR THE REMAINING CHANNELS OF THE MQJ UNDER TEST.
g. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB
h. REPEAT STEPS ‘E’ THROUGH ‘G’ FOR ALL CHANNELS
A.3.2.2 MEASURE THE OPTICAL RETURN LOSS OF THE TERMINI ENDS
a. CONNECT ST-ST REFERENCE MQJ TO ORLM, AND THEN CONNECT ST OF ST- M28876
REFERENCE MQJ TO THE ST-ST REFERENCE MQJ AND REFERENCE ORLM BY
MANDREL WRAPPING ST-M28876 REFERENCE MQJ
b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ
FROM THE MANDREL
c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9
d. CONNECT THE TERMINI END OF THE MQJ UNDER TEST TO THE TERMINI END OF ST-
M28876 REFERENCE MQJ
e. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, NEAR THE ST END, AND
RECORD THE DATA (SEE FIGURE A-8)
NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A
STABLE VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE
USUALLY SUFFICIENT TO OBTAIN A STABLE VALUE.
f. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB
g. REPEAT STEPS ‘M’ THROUGH ‘N’ FOR ALL CHANNELS
FIGURE A-7 - ORLM REFERENCE SETUP
W
V S
E A
D R
A W
IN
G
N O
S
CAGE
53711
REV
SCALE: NONE UCI WT GRP SHEET 21
FIGURE A-8 - ORLM TEST SETUP
File details come from the government source that posted it.