0211-04_-_Fiber_Optic_MQJs_-_Drawing.pdf

PDF 696 KB Posted

Attached to
Fiber Optic Measurement Quality Jumper Cables (MQJ)
Solicitation number
N0017819Q6707
Issued by

About this file

KITCO Fiber Optics drawings Please Note: Only Authorized Resellers will be accepted.

View the file

Other files

File Type Posted
posted_SF18.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV

STATUS

OF

SHEETS

REV G G G G G G G G G G G G G G G G G G G G

SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

REV G

SHEET 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

E S

W B

N A

V S

E A

D R

A W

IN

G

N O

S

H T

R

V

G

APPLICATION

NEXT ASSY USED ON

REVISIONS

REV DESCRIPTION DATE APPROVED

A

B C

RELEASED AS REVISION A.

UPDATE OF REVISION A.

UPDATE OF REVISION B.

10/5/94

4/11/95 9/30/99

DISTRIBUTION STATEMENT A: APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

TOLERANCES ARE:

CAGE CODE

CONTRACT NO.

DEPARTMENT OF THE NAVY

NAVAL SEA SYSTEMS COMMAND

WASHINGTON, D.C. 20362-5101

JUMPERS, TEST EQUIPMENT

FIBER OPTIC

SIZE

A

CAGE

53711

ESWBS

DRAWING NO.

6877804

REV

G

(SIGN ONLY IF ENGINEERING HAS BEEN

“PROVED”BY MANUFACTURE AND TEST

SIGNATURE DOES NOT DENOTE APPROVAL

H. LEWIS

G. BROWN

E. BLUEBOND

G. BROWN

D. KNUDSEN

9/30/99

9/30/99

9/30/99

9/30/99

9/30/99

SCALE: NONE UCI WT GRP SHEET 1 OF 21

APPROVED

ENGINEER

CHECKED

PREPARED

ACCEPTED FOR

NAVSEA

APPROVED BY

NAVSEA

FINISHES:

MATERIAL:

FRACTIONS

ANGLES

P

DECIMALS

.xx+/-

.xxx+/-

DO NOT SCALE DRAWING

VENDOR ITEM DRAWING

D UPDATE OF REVISION C. 1/09/06

E UPDATE OF REVISION D. 2/04/08

F UPDATE OF REVISION E. 5/1/18

G UPDATE OF REVISION F. 8/28/18

LIST OF REFERENCES

REF

NO.

DOCUMENT NUMBER DOCUMENT TITLE

MIL-STD-2042-6

S9086-PF-STM-010/CH-435

MIL-STD-1678-5

MIL-STD-1678-2

A-A-59940/1

A-A-59940/3

MIL-PRF-85045

MIL-PRF-28876

MIL-PRF-29504

FIBER OPTIC TOPOLOGY INSTALLATION STANDARD

METHODS FOR NAVAL SHIPS (TEST)

FIBER OPTIC TOPOLOGY OPERATION MAINTENANCE

AND REPAIR

FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND

MEASUREMENTS. PART 5: DESIGN PHASE,

SUPPLEMENTAL AND LEGACY MEASUREMENTS

FIBER OPTIC CABLING SYSTEMS REQUIREMENTS

AND MEASUREMENTS. PART 2: OPTICAL

MEASURMENTS

CONNECTORS, FIBER OPTIC, SINGLE FIBER SMALL

FORM FACTOR, LC TYPE

CONNECTORS, FIBER OPTIC, SINGLE FIBER ST TYPE

CABLES, FIBER OPTIC

CONNECTORS, FIBER OPTIC

TERMINI, FIBER OPTIC CONNECTOR

W

V S

E A

D R

A W

IN

G

N O

S

SIZE

CAGE

53711

ESWBS

DRAWING NO.

6877804

REV

G

SCALE: NONE UCI WT GRP SHEET 2

1. NOTES

1.1 NAVAL SURFACE WARFARE CENTER DAHLGREN DIVISION, FIBER OPTICS SECTION

IS THE TECHNICAL DIRECTION AGENT (TDA) FOR FIBER OPTICS FOR NAVSEA AND

THE APPROVING ACTIVITY FOR MEASUREMENT QUALITY JUMPERS (MQJs).

1.2 ORGANIZATIONS ARE ALLOWED TO MANUFACTURE MQJs FOR THEIR OWN INTERNAL USE AS LONG AS THE MQJs MEET THE REQUIREMENTS (SECTION 2.0), SPECIFIED

CONFIGURATIONS (SECTION 3.0) AND PASS THE MQJ SELECTION CRITERIA DETAILED IN

MIL-STD-2042 PART 6, METHOD 6F1. ORGANIZATIONS MANUFACTURING MQJs FOR EXTERNAL USE (eg. DISTIBRUTION/SALE) SHALL MEET THE REQUIREMENTS, CONFIGURATIONS, VERIFICATIONS AND APROVAL PROCESS DEFINED IN THIS

DRAWING.

1.3 SUGGESTED SOURCE OF SUPPLY

FOR A COMPLETE LIST OF VENDORS APPROVED TO MANUFACTURE AND SELL

MEASUREMENT QUALITY JUMPER CABLES, PLEASE SEE THE RECOMMENDED TEST

EQUIPMENT LIST ON THE NAVY SHIPBOARD FIBER OPTIC WEBSITE LOCATED AT

www.navsea.navy.mil/Home/WarfareCenters/NSWCDahlgren/WhatWeDo/NavyShipboardFiberOp tics.aspx . VENDOR PART NUMBERS ARE ALSO LOCATED ON THE WEBSITE. DUE TO THE

DYNAMIC NATURE OF WEB ADDRESSES THE CURRENT WEBSITE URL CAN BE

OBTAINED BY E-MAILING DLGR_NSWC_FOWEB@NAVY.MIL WITH THE SUBJECT LINE

“WEBSITE URL REQUEST”. AN AUTOMATED REPLY WILL CONTAIN THE CURRENT WEB

ADDRESS.

1.4 SUBSTITUTION OF PIECES OR ITEMS IS NOT AUTHORIZED WITHOUT APPROVAL OF THE

APPROVING ACTIVITY, NAVAL SURFACE WARFARE CENTER, DAHLGREN DIVISION,

FIBER OPTICS SECTION.

1.5 THESE ITEMS ARE TO BE USED IN THE PERFORMANCE OF FIBER OPTIC TESTING AS

SPECIFIED IN THE CURRENT REVISIONS OF REFERENCES 1 AND 2.

1.6 ITEMS NO. 1 THROUGH 4 AND 14 (SEE TABLE I) AND ITEMS 1SME THROUGH 4SME AND

14SME (SEE TABLE II) ARE FOR USE WITH AN OPTICAL TIME DOMAIN REFLECTOMETER

(OTDR).

1.6 ITEMS NO. 5 THROUGH 13 AND 15 THROUGH 16 (SEE TABLE I), AND ITEMS 5SME THROUGH

13SME AND 15SME THORUGH 16SME (SEE TABLE II) ARE FOR USE WITH AN OPTICAL LOSS

TEST SET (OLTS) AND OPTICAL RETURN LOSS (ORL) METERS.

1.7 INDIVIDUAL ITEMS SHALL BE PROCURED USING THE BASIC DRAWING NUMBER FOLLOWED

BY A DASH AND THE ITEM NUMBER FROM TABLE I-II. TABLE III & IV ARE ADDED FOR QUICK

REFERENCE ONLY, USING COMMON LANGUAGE EQUIVALENTS.

1.8 ALL PIECES IDENTIFIED BY THE MILITARY PART NUMBER SHALL BE FROM AN APPROVED

SOURCE OF SUPPLY LISTED ON THE QUALIFIED PRODUCTS LIST (QPL)

(http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-

Shipboard-Fiberoptics/Status-QPLs/) UNLESS OTHERWISE APPROVED BY THE APPROVING

ACTIVITY.

mailto:DLGR_NSWC_FOWEB@NAVY.MIL http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-Shipboard-Fiberoptics/Status-QPLs http://www.navsea.navy.mil/Home/Warfare-Centers/NSWC-Dahlgren/What-We-Do/Navy-Shipboard-Fiberoptics/Status-QPLs

SHEET 3

E S

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

SCALE: NONE UCI WT GRP

2. REQUIREMENTS

2.1 THE SHIPBOARD FIBER OPTIC MQJs SHALL MEET THE REQUIREMENTS SPECIFIED HEREIN.

2.2 THE END FACE OF ALL LIGHT DUTY (ST, LC) CONNECTORS, TERMINI PINS AND SOCKETS

ON MQJs, WHEN INSPECTED USING A 400X VIDEO SCOPE, SHALL HAVE NO VISIBLE

SCRATCHES.

2.3 THE SHIPBOARD FIBER OPTIC MQJs SHALL BE TESTED FOR OPTICAL LOSS AND RETURN

LOSS (IF SINGLE MODE) IN ACCORDANCE WITH THE CURRENT REVISION OF REFERENCE 1

AND THIS DOCUMENT.

2.4 SHIPBOARD FIBER OPTIC MQJs WITH MIL-C-28876 PLUGS OR RECEPTACLES KEYED WITH

ONLY THE MASTER KEY SHALL BE VISIBLY MARKED WITH THE FOLLOWING:

WARNING

SPECIAL MEASUREMENT QUALITY JUMPER

VISUALLY VERIFY PROPER KEY ALIGNMENT

BEFORE ENGAGING WITH MATING CONNECTORS.

2.5 ALL SHIPBOARD FIBER OPTIC MQJs SHALL BE VISIBLY MARKED WITH THE FOLLOWING:

FIBER OPTIC MEASUREMENT QUALITY

JUMPER CABLE

2.6 FOR ITEMS TERMINATED WITH MIL-S-24623/4-01 SPLICES, THE CABLE SHALL BE STRAIN

RELIEVED TO THE SPLICE USING ADHESIVE LINED HEAT SHRINK TUBING. CABLE

STRENGTH MEMBERS SHALL BE PLACED AROUND THE REAR OF THE SPLICE BEFORE THE

HEAT SHRINK TUBING IS APPLIED.

2.7 CONNECTORS ASSEMBLED USING COLOR CODED SINGLE FIBER CABLING SHALL ASSIGN

THE SINGLE FIBER CABLES TO TERMINI AS FOLLOWS: 1 – BLUE, 2 – ORANGE, 3 – GREEN,

4 – BROWN, 5 – GRAY, 6 – WHITE, 7 – RED, 8 – BLACK. FOR CONNECTORS ASSEMBLED

USING SAME COLOR SINGLE FIBER CABLING, THE SINGLE FIBER CABLING SHALL BE

MARKED WITH THE CORRESPONDING TERMINUS NUMBER.

2.8 MULTIFIBER MQJ CABLES SHALL HAVE 18 +/- 1 INCHES OF SINGLE FIBER CABLE EXPOSED

AT THE END OF THE JUMPER CABLE TERMINATED WITH SINGLE FIBER CONNECTORS.

2.9 MULTIFIBER MQJ CABLES CONSTRUCTED USING M85045/16 SINGLE FIBER CABLE SHALL

INCLUDE A STRAIN RELIEF MECHANISM AT THE POINT OF TRANSITION FROM THE

PROTECTIVE TUBING TO THE UNPROTECTED M85045/16 SINGLE FIBER CABLE.

2.10 CONNECTOR PARTS IDENTIFIED FOR SINGLE MODE MQJ CABLES MAY BE UTILIZED IN THE

CONSTRUCTION OF MULTIMODE JUMPER CABLES.

SHEET 4

E S

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP

2.11 END CONNECTIONS ON MULTIMODE MQJ CABLES SHALL MEET THE FOLLOWING LOSS

REQUIREMENTS:

EACH M29504/14 or M29504/15 TERMINUS SHALL HAVE A MEAN OPTICAL LOSS OF < 0.70 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB. EACH LIGHT DUTY TYPE CONNECTOR SHALL HAVE A MEAN OPTICAL LOSS OF < 0.35 dB AND A MAXIMUM STANDARD DEVIATION:

OF 0.05 dB. EACH M24623/4-01 SHALL HAVE A MEAN OPTICAL LOSS OF < 0.30 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB.

2.12 END CONNECTIONS ON SINGLE MODE MEASUREMENT QUALITY JUMPER CABLES SHALL

MEET THE FOLLOWING LOSS REQUIREMENTS:

EACH M29504/14 or M29504/15 TERMINUS SHALL HAVE A MEAN OPTICAL LOSS OF < 0.70 dB AND A MAXIMUM STANDARD DEVIATION OF 0.10 dB. EACH LIGHT DUTY TYPE CONNECTOR SHALL HAVE A MEAN OPTICAL LOSS OF < 0.35 dB AND A MAXIMUM STANDARD DEVIATION:

OF 0.10 dB. EACH M24623/4-01 SHALL HAVE A MEAN OPTICAL LOSS OF < 0.30 dB AND A MAXIMUM STANDARD DEVIATION OF 0.05 dB.

2.13 END CONNECTIONS ON SINGLE MODE MQJ CABLES SHALL BE OF ENHANCED

PERFORMANCE AND MEET REFLECTANCE REQUIREMENTS of -43.0 dB OR GREATER

2.14 CONNECTOR AND TERMINUS RETURN LOSS SHALL BE MEASURED IN ACCORDANCE WITH

MIL-STD-1678-2 MEASUREMENT 2105

2.15 END FACE GEOMETRY SHALL BE IN ACCORDANCE WITH MIL-STD-1678-5; MEASUREMENT

5201.1.

2.16 MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-130

3. MQJ CONFIGURATIONS

3.1 MQJs SHALL BE PROVIDED IN ONE OR MORE OF THE FOLLOWING CONFIGURATIONS

SPECIFIED IN TABLE I/III FOR MULTIMODE MQJs AND TABLE II/IV FOR SINGLE MODE MQJs.

3.2 SPECIAL CONFIGURATIONS, NOT SPECIFIED IN TABLES I – IV, MAY BE USED WITH

AUTHORIZED APPROVAL (SEE 1.1) BUT WILL NOT BE CONSIDERED STANDARD. SPECIAL

CONFIGURATIONS WILL NOT BE ADDED TO THE RECOMMENDED TEST EQUIPMENT LIST.

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 5

TABLE I

MULTIMODE FIBER OPTIC MQJ CABLES

ITEM

LENGTH

(M)

CONNECTOR

MILITARY

OR VENDOR

PART NO.

CABLE

MILITARY

OR VENDOR

PART NO.

CONNECTOR

ADAPTER

VENDOR

PART NO.

CONNECTOR

MILITARY

OR VENDOR

PART NO.

TERMINI

MILITARY

OR VENDOR

PART NO.

1 50 A-A-59940/3-

111SN

M85045/16-01 NA

A-A-59940/3-

111SN

NA

2 50 A-A-59940/3-

111SN

M85045/16-01 NA M24623/4-01 NA

3 50 A-A-59940/3-

111SN

M85045/16-01 NA NA M29504/14-4131C

4 50 A-A-59940/3-

111SN

M85045/16-01 NA NA M29504/15-4171C

5 1 A-A-59940/3-

111SN

M85045/16-01 NA

A-A-59940/3-

111SN

NA

6 1 A-A-59940/3-

111SN

M85045/16-01 NA M24623/4-01 NA

7 1 A-A-59940/3-

111SN

M85045/18-01 NA 1145846-B042P0S

M29504/14-4131C M85045/16-01

127-021-1-1-16CKHE

189-014NF13-07 4565143-B04P0S

8 1 A-A-59940/3-

111SN

M85045/18-01 NA 1145840-B042S0S

M29504/15-4171C M85045/16-01

127-021-1-1-16CKHE

189-014NF13-07 4565141-B04S0S

9 1 A-A-59940/3-

111SN

M85045/17-01 NA 1145846-C081P0S

M29504/14-4131C M85045/16-01

127-021-1-1-16CKHE

189-014NF15-07 4565143-C08P0S

10 1 A-A-59940/3-

111SN

M85045/17-01 NA 1145840-C081S0S

M29504/15-4171C M85045/16-01

127-021-1-1-16CKHE

189-014NF15-07 4565141-C08S0S

12 1 A-A-59940/3-

111SN

M85045/16-01

127-021-1-1-32CKHE

189-014NF23-07 4565143-F31P0S M29504/14-4131C

13 1 A-A-59940/3-

111SN

M85045/16-01

127-021-1-1-32CKHE

189-014NF23-07 4565141-F31SOS M29504/15-4171C

14 50 A-A-59940/3-

111SN

M85045/16-01 NA

A-A-59940/1-

111SN

NA

15 1 A-A-59940/3-

111SN

M85045/16-01 NA

A-A-59940/1-

111SN

NA

16 1 A-A-59940/3-

111SN

M85045/16-01 189-014NF11 4565141-A021SOS M29504/15-4171C

SHEET 6

S

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP

TABLE II

SINGLE MODE ENHANCED PERFORMANCE FIBER OPTIC MQJ CABLES

LENGTH

(M)

CONNECTOR

MILITARY

OR VENDOR

PART NO.

CABLE

MILITARY

OR VENDOR

PART NO.

CONNECTOR

ADAPTER

VENDOR

PART NO.

CONNECTOR

MILITARY

OR VENDOR

PART NO.

TERMINI

MILITARY

OR VENDOR

PART NO.

1SME 50

A-A-59940/3-

121SN

M85045/16-02 NA

A-A-59940/3-

121SN

NA

3SME 50

A-A-59940/3-

121SN

M85045/16-02 NA NA M29504/14-4141C

4SME 50

A-A-59940/3-

121SN

M85045/16-02 NA NA M29504/15-4181C

5SME 1

A-A-59940/3-

121SN

M85045/16-02 NA

A-A-59940/3-

121SN

NA

7SME 1

A-A-59940/3-

121SN

M85045/18-02 NA 1145846-B042P0S

M29504/14-4141C M85045/16-02

127-021-1-1-16CKHE

189-014NF13-07 4565143-B04P0S

8SME 1

A-A-59940/3-

121SN

M85045/18-02 NA 1145840-B042S0S

M29504/15-4181C M85045/16-02

127-021-1-1-16CKHE

189-014NF13-07 4565141-B04S0S

9SME 1

A-A-59940/3-

121SN

M85045/17-02 NA 1145846-C081P0S

M29504/14-4141C M85045/16-02

127-021-1-1-16CKHE

189-014NF15-07 4565143-C08P0S

10SME 1

A-A-59940/3-

121SN

M85045/17-02 NA 1145840-C081S0S

M29504/15-4181C M85045/16-02

127-021-1-1-16CKHE

189-014NF15-07 4565141-C08S0S

12SME 1

A-A-59940/3-

121SN

M85045/16-02

127-021-1-1-32CKHE

189-014NF23-07 4565143-F31P0S M29504/14-4141C

13SME 1

A-A-59940/3-

121SN

M85045/16-02

127-021-1-1-32CKHE

189-014NF23-07 4565141-F31SOS M29504/15-4181C

14SME 50

A-A-59940/3-

121SN

M85045/16-02 NA

A-A-59940/1-

121SN

NA

15SME 1

A-A-59940/3-

121SN

M85045/16-02 NA

A-A-59940/1-

121SN

NA

16SME 1

A-A-59940/3-

121SN

M85045/16-02 189-014F11 4565141-A021SOS M29504/15-4181C

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 7

TABLE III

MM MQJ QUICK REFERENCE

LENGTH

(M)

CONNECTOR

CABLE

MILITARY

OR VENDOR

PART NO.

CONNECTOR

ADAPTER

VENDOR

PART NO.

CONNECTOR

TERMINI

MILITARY

OR

VENDOR

PART NO.

1 50 ST

SINGLE FIBER

TIGHT BUFFER MM

NA ST NA

2 50 ST

SINGLE FIBER

TIGHT BUFFER MM

NA

ROTARY

MECHANICAL SPLICE

NA

3 50 ST

SINGLE FIBER

TIGHT BUFFER MM

NA NA PIN*

4 50 ST

SINGLE FIBER

TIGHT BUFFER MM

NA NA SOCKET*

5 1 ST

SINGLE FIBER

TIGHT BUFFER MM

NA ST NA

6 1 ST

SINGLE FIBER

TIGHT BUFFER MM

NA

ROTARY

MECHANICAL SPLICE

NA

7 1 ST

FOUR FIBERS

SHIPBOARD MM

NA

UNIVERSAL SHELL

SIZE 13 PLUG

CONNECTOR -

CONVENTIONAL PIN*

SINGLE FIBER

TIGHT BUFFER MM

(4 EA)

SHELL SIZE 13

ADAPTER

UNIVERSAL SHELL SIZE

13 PLUG CONNECTOR -

CONDUIT

8 1 ST

FOUR FIBERS

SHIPBOARD MM

NA

UNIVERSAL SHELL SIZE

13 RECEPTACLE

CONNECTOR -

CONVENTIONAL SOCKET*

SINGLE FIBER

TIGHT BUFFER MM

(4 EA)

SHELL SIZE 13

ADAPTER

UNIVERSAL SHELL SIZE

13 RECEPTACLE

CONNECTOR - CONDUIT

9 1 ST

EIGHT FIBERS

SHIPBOARD MM

NA

UNIVERSAL SHELL SIZE

15 PLUG CONNECTOR -

CONVENTIONAL

PIN*

SINGLE FIBER

TIGHT BUFFER MM

(8 EA)

SHELL SIZE 15

ADAPTER

UNIVERSAL SHELL SIZE

15 PLUG CONNECTOR -

CONDUIT

10 1 ST

EIGHT FIBERS

SHIPBOARD MM

NA

UNIVERSAL SHELL SIZE

15 RECEPTACLE

CONNECTOR -

CONVENTIONAL SOCKET*

SINGLE FIBER

TIGHT BUFFER MM

(8 EA)

SHELL SIZE 15

ADAPTER

UNIVERSAL SHELL SIZE

15 RECEPTACLE

CONNECTOR - CONDUIT

12 1 ST

SINGLE FIBER

TIGHT BUFFER MM

(31 EA)

SHELL SIZE 23

ADAPTER

UNIVERSAL SHELL SIZE

23 PLUG CONNECTOR -

CONVENTIONAL

PIN*

13 1 ST

SINGLE FIBER

TIGHT BUFFER MM

(31 EA)

SHELL SIZE 23

ADAPTER

UNIVERSAL SHELL SIZE

23 RECEPTACLE

CONNECTOR -

CONVENTIONAL

SOCKET*

14 50 ST

SINGLE FIBER

TIGHT BUFFER MM

NA LC NA

15 1 ST

SINGLE FIBER

TIGHT BUFFER MM

NA LC NA

16 1 ST

SINGLE FIBER

TIGHT BUFFER MM

(2 EA)

SHELL SIZE 11

ADAPTER

UNIVERSAL SHELL SIZE

11 PLUG CONNECTOR -

CONVENTIONAL

SOCKET*

* LONG LENGTH, CERAMIC GUIDE BUSHING, MM, W/ CRIMP SLEEVE, FOR MIL-PRF-28876 CONNECTORS

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 8

TABLE IV

SME MQJ QUICK REFERENCE

LENGTH

(M)

CABLE

ADAPTER

CONNECTOR

TERMINI

MILITARY

OR

VENDOR

PART NO.

1SME 50 ST

SINGLE FIBER

TIGHT BUFFER SM

NA ST NA

3SME 50 ST

SINGLE FIBER

TIGHT BUFFER SM

NA NA PIN*

4SME 50 ST

SINGLE FIBER

TIGHT BUFFER SM

NA NA SOCKET*

5SME 1 ST

SINGLE FIBER

TIGHT BUFFER SM

NA ST NA

7SME 1 ST

FOUR FIBERS

SHIPBOARD SM

NA

UNIVERSAL SHELL SIZE

13 PLUG CONNECTOR -

CONVENTIONAL

PIN*

SINGLE FIBER

TIGHT BUFFER SM

(4 EA)

SHELL SIZE 13

ADAPTER

UNIVERSAL SHELL SIZE

13 PLUG CONNECTOR -

CONDUIT

8SME 1 ST

FOUR FIBERS

SHIPBOARD SM

NA

UNIVERSAL SHELL SIZE

13 RECEPTACLE

CONNECTOR -

CONVENTIONAL SOCKET*

SINGLE FIBER

TIGHT BUFFER SM

(4 EA)

SHELL SIZE 13

ADAPTER

UNIVERSAL SHELL SIZE

13 RECEPTACLE

CONNECTOR - CONDUIT

9SME 1 ST

EIGHT FIBERS

SHIPBOARD SM

NA

UNIVERSAL SHELL SIZE

15 PLUG CONNECTOR -

CONVENTIONAL

PIN*

SINGLE FIBER

TIGHT BUFFER SM

(8 EA)

SHELL SIZE 15

ADAPTER

UNIVERSAL SHELL SIZE

15 PLUG CONNECTOR -

CONDUIT

10SME 1 ST

EIGHT FIBERS

SHIPBOARD SM

NA

UNIVERSAL SHELL SIZE

15 RECEPTACLE

CONNECTOR -

CONVENTIONAL SOCKET*

SINGLE FIBER

TIGHT BUFFER SM

(8 EA)

SHELL SIZE 15

ADAPTER

UNIVERSAL SHELL SIZE

15 RECEPTACLE

CONNECTOR - CONDUIT

12SME 1 ST

SINGLE FIBER

TIGHT BUFFER SM

(31 EA)

SHELL SIZE 23

ADAPTER

UNIVERSAL SHELL SIZE

23 PLUG CONNECTOR -

CONVENTIONAL

PIN*

13SME 1 ST

SINGLE FIBER

TIGHT BUFFER SM

(31 EA)

SHELL SIZE 23

ADAPTER

UNIVERSAL SHELL SIZE

23 RECEPTACLE

CONNECTOR -

CONVENTIONAL

SOCKET*

14SME 50 ST

SINGLE FIBER

TIGHT BUFFER SM

NA LC NA

15SME 1 ST

SINGLE FIBER

TIGHT BUFFER SM

NA LC NA

16SME 1 ST

SINGLE FIBER

TIGHT BUFFER SM

(2 EA)

SHELL SIZE 11

ADAPTER

UNIVERSAL SHELL SIZE

11 PLUG CONNECTOR

CONVENTIONAL

SOCKET*

* LONG LENGTH, CERAMIC GUIDE BUSHING, SM, W/ CRIMP SLEEVE, FOR MIL-PRF-28876 CONNECTORS

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 9

4. VERIFICATION OF REQUIREMENTS

4.1 UNLESS OTHERWISE SPECIFIED BY THE PROCURING ACTIVITY THE SUPPLIER IS

RESPONSIBLE FOR THE PERFORMANCE OF ALL ITEMS CONTAINED HEREIN WITH REGARD

TO THE ABOVE REQUIREMENTS. TEST DATA MAY BE PROVIDED TO DEMONSTRATE

PERFORMANCE, HOWEVER THE PROCURING ACTIVITY RESERVES THE RIGHT TO PERFORM

ANY OF THE INSPECTIONS SPECIFIED. TEST SAMPLES SHALL BE SUBMITTED TO THE

APPROVING ACTIVITY.

4.2 END FACE GEOMETRY DATA WILL ONLY BE PROVIDED IF REQUESTED WHEN ORDERING.

5. EVALUATION PROCESS FOR APPROVAL OF MEASUREMENT QUALITY JUMPERS (MQJs)

5.1 THE PROCESS FOR EVALUATION AND APPROVAL OF MQJs DEVELOPED IN ACCORDANCE

WITH NAVSEA DRAWING 6877804 IS DESCRIBED HEREIN.

5.2 PREFERRED PROCESS

5.2.1 ORGANIZATIONS SEEKING APPROVAL FOR THEIR MQJs MUST CONTACT, IN WRITING, NSWCDD, AT DLGR_NSWC_FO_ENG@NAVY.MIL REQUESTING THE APPROVAL OF THEIR

MQJs. NSWCDD WILL CONTACT THE ORGANIZATION SEEKING APPROVAL AND PROVIDE

GUIDANCE ON HOW TO PROCEED THROUGH THE PROCESS.

5.2.2 ORGANIZATION SEEKING APPROVAL PROVIDES MQJ CANDIDATES (SEE 5.3 FOR

REQUIRED SUBMISSIONS) OR AS DIRECTED BY NSWCDD.

5.2.3 NSWCDD VERIFIES THAT THE PRODUCTS PASS THE REQUIREMENTS HEREIN (SEE SECTION

2 AND APPENDIX A).

5.2.4 UPON SUCCESSFULLY COMPLETING THE PROCESS, NSWCDD WILL CONTACT THE

ORGANIZATION SEEKING APPROVAL AND NOTIFY THEM OF THE RESULTS VIA EMAIL. THE

PARTS THAT HAVE OBTAINED FULL APPROVAL (SEE TABLE V OR TABLE VI) WILL BE ADDED

TO THE RECOMMENDED TEST EQUIPMENT LIST WHICH IS PUBLISHED ON THE NSWCDD

FIBER OPTIC WEBSITE.

5.2.5 INTERIM APPROVED MQJs (SEE TABLE V OR TABLE VI) WILL NOT APPEAR ON THE

RECOMMENDED TEST EQUIPMENT LIST. TO OBTAIN FULL APPROVAL FOR AN INTERIM

APPROVED MQJ THE ORGANIZATION SHALL, UPON FIRST SALE OF AN INTERIM APPROVED

MQJ, SEND A COPY OF THE FOLLOWING DATA FOR THE MQJ TO THE APPROVING ACTIVITY:

INSERTION LOSS, RETURN LOSS (IF SINGLE MODE), INTERFEROMETER MEASUREMENTS,

AND THE CUSTOMER’S POC INFORMATION. IF THE DATA INDICATES PASSING RESULTS

AND THE CUSTOMER IS SATISFIED WITH THE PRODUCT, THE ORGANIZATION WILL THEN

RECEIVE FULL APPROVAL FOR THAT PRODUCT AND THE PRODUCT WILL BE ADDED TO THE

RECOMMENDED TEST EQUIPMENT LIST.

5.2.6 FOR CHANGES IN MQJ PRODUCT OR MANUACTURING PROCESS AFTER APPROVAL

CONTACT NSWCDD (SEE 5.4)

5.3. REQUIRED SAMPLE MQJ SUBMISSIONS

mailto:DLGR_NSWC_FO_ENG@NAVY.MIL

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 10

5.3.1 REQUIRED SAMPLES FOR ST TO LC MQJs. THE REQUESTING ORGANIZATION SHALL SUPPLY

NAVSEA DRAWING 6877804 ITEM NUMBERS 15 AND 15SME FOR EVALUATION. OPTICAL

LOSS AND OPTICAL RETURN LOSS DATA (SM ONLY) ALONG WITH INTERFEROMETER DATA

SHALL BE PROVIDED FOR EACH OF THE SAMPLES SUBMITTED. NSWCDD WILL THEN VERIFY

THAT THE PRODUCTS PASS THE REQUIREMENTS WITHIN NAVSEA DRAWING 6877804. UPON

PASSING REQUIREMENTS, THE ORGANIZATION WILL BE GRANTED THE MANUFACTURING

AND SALE APPROVALS AS SHOWN IN TABLE VI.

5.3.2 REQUIRED SAMPLES FOR ALL OTHER MQJ TYPES. THE REQUESTING ORGANIZATION

SHALL PROVIDE NAVSEA DRAWING 6877804 ITEM NUMBERS: 7, 8, 12SME, AND 13SME

ALONG WITH TWO 1 METER MM LEADS WITH M29504/14 ON ONE END AND M29504/15 ON

THE OTHER END, AND TWO 1 METER SM LEADS WITH SME POLISHED M29504/14 ON ONE

END AND SME POLISHED M29504/15 ON THE OTHER END TO NSWCDD FOR EVALUATION.

OPTICAL LOSS AND OPTICAL RETURN LOSS DATA (SM ONLY) ALONG WITH

INTERFEROMETER DATA SHALL BE PROVIDED FOR EACH OF THE SAMPLES SUBMITTED.

NSWCDD WILL THEN VERIFY THAT THE PRODUCTS PASS THE REQUIREMENTS WITHIN

NAVSEA DRAWING 6877804. UPON PASSING REQUIREMENTS, THE REQUESTING

ORGANIZATION WILL BE GRANTED THE MANUFACTURING AND SALE APPROVALS AS

SHOWN IN TABLE VI.

TABLE V - FULL AND INTERIM APPROVAL (ST, M29504/14, M29504/15, M28876 PLUG AND

RECEPTACLE)

ITEM NUMBER APPROVAL STATUS /1 /2

12SME FULL APPROVAL

13SME FULL APPROVAL

7 FULL APPROVAL

8 FULL APPROVAL

1 INTERIM APPROVAL

3 INTERIM APPROVAL

4 INTERIM APPROVAL

5 INTERIM APPROVAL

9 INTERIM APPROVAL

10 INTERIM APPROVAL

12 INTERIM APPROVAL

13 INTERIM APPROVAL

16 INTERIM APPROVAL

1SME INTERIM APPROVAL

3SME INTERIM APPROVAL

4SME INTERIM APPROVAL

5SME INTERIM APPROVAL

7SME INTERIM APPROVAL

8SME INTERIM APPROVAL

9SME INTERIM APPROVAL

10SME INTERIM APPROVAL

16SME INTERIM APPROVAL

/1 TABLE V PROVIDES DIRECTION FOR ORGANIZATIONS LOOKING TO OBTAIN

APPROVAL TO MANUFACTURE AND SELL SM AND MM MQJs IN ACCORDANCE

WITH NAVSEA DRAWING 6877804.

/2 IF THE REQUESTING ORGANIZATION ONLY WANTS APPROVAL TO MANUFACTURE

AND SELL SPECIFIC ITEMS IN TABLE V, THE ORGANIZATION MUST CONTACT THE

FIBER OPTIC TECHNOLOGY SECTION (DLGR_NSWC_FO_ENG@NAVY.MIL) TO

DISCUSS OTHER OPTIONS FOR THE APPROVAL TO MANUFACTURE AND SELL

THOSE ITEMS.

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 11

TABLE VI - FULL AND INTERIM APPROVAL (ST to LC MQJs)

NAVSEA DRAWING

6877804 ITEM NUMBER

QUANTITY

APPROVAL STATUS

/1 /2

15SME 15 FULL APPROVAL

15 5 FULL APPROVAL

14SME N/A INTERIM APPROVAL

14 N/A INTERIM APPROVAL

/1 TABLE VI PROVIDES DIRECTION FOR ORGANIZATIONS LOOKING TO OBTAIN APPROVAL

TO MANUFACTURE AND SELL ST TO LC SM AND MM MQJs IN ACCORDANCE WITH

NAVSEA DRAWING 6877804.

/2 IF THE REQUESTING ORGANIZATION ONLY WANTS APPROVAL TO MANUFACTURE AND

SELL SPECIFIC ITEMS IN TABLE VI, THE ORGANIZATION MUST CONTACT THE FIBER

OPTIC TECHNOLOGY SECTION (DLGR_NSWC_FO_ENG@NAVY.MIL) TO DISCUSS OTHER

OPTIONS FOR THE APPROVAL TO MANUFACTURE AND SELL THOSE ITEMS.

5.4 ALTERNATE APPROVAL PROCESS. REQUESTING ORGANIZATIONS THAT DO NOT WISH TO

FOLLOW THE PREFERRED PROCESS MUST CONTACT NSWCDD AT

DLGR_NSWC_FO_ENG@NAVY.MIL WITH A REQUEST ON WHAT SUBSET OF MQJs FOR WHICH

THEY ARE SEEKING APPROVAL. NSWCDD WILL THEN WORK WITH THE REQUESTING

ORGANIZATION TO DEFINE THE REQUIRED SAMPLE SET FOR EVALUATION.

5.5 CHANGES IN MANUFACTURING PROCESSES. IF THE ORGANIZATION MAKES ANY CHANGES TO

ITS MANUFACTURING PROCESS (E.G. CHANGE FACILITIES, CONTRACTORS, ETC.) THEY SHALL

NOTIFY NSWCDD, AT DLGR_NSWC_FO_ENG@NAVY.MILOF THE CHANGE. NSWCDD RESERVES

THE RIGHT TO CANCEL THE ORGANIZATION’S APPROVAL IF THEY BELIEVE THE CHANGE CAN

BE DETRIMENTAL TO THE QUALITY OF THE MQJ OR TO REQUEST RE-EVALUATION OF THE

MQJs.

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 12

APPENDIX A

EVALUATION OF MEASUREMENT QUALITY JUMPERS

A.1 VISUAL INSPECTION AND ENDFACE GEOMETRY

a. TAKE SEVERAL PICTURES OF THE MQJs UNDER TEST AT DIFFERENT ANGLES.

b. COMPARE MQJs UNDER TEST WITH NAVSEA DRAWING 6877804 AND NOTE ANY

DIFFERENCES.

c. INSPECT PHYSICAL CONSTRUCTION OF MQJs FOR QUALITY OF WORKMANSHIP AND

COMMENT.

d. VISUALLY INSPECT ALL LIGHT DUTY CONNECTORS, TERMINI PINS AND SOCKETS ON

MQJs AND COMMENT ON WORKMANSHIP. THE FIBER OPTIC SECTION USES A 400X

VIDEO SCOPE WITH A BLUE LIGHT TO VIEW CONNECTOR AND TERMINI END FACES. IN

ORDER TO PASS THE INSPECTION, THERE SHALL BE NO VISIBLE SCRATCHES

OBSERVED WHEN USING THE VIDEO SCOPE.

e. CHECK ALL LIGHT DUTY CONNECTOR ENDFACES OF MQJs USING THE

INTERFEROMETER AND PRINT COPIES OF THE MEASUREMENTS. THE REQUESTING

ORGANIZATION SHALL SUPPLY COPIES OF THE INTERFEROMETER MEASUREMENTS

OF ALL SAMPLES SUBMITTED. CONNECTORS SHALL MEET GR-326 CRITERIA FOR

DOMED PHYSICAL CONTACT CONNECTORS. THE FOLLOWING IS THE CRITERIA:

i. RADIUS OF CURVATURE (ROC) SHALL BE BETWEEN 7MM AND 25 MM

ii. APEX OFFSET OF THE SPHERICAL ENDFACE TO THE AXIS OF THE FERRULE SHALL

BE LESS THAN 50 MICROMETERS

iii. FIBER PROTRUSION SHALL NOT EXCEED 50 NM; WHEN ROC IS 25 MM, FIBER

UNDERCUT SHALL BE NO MORE THAN 50 NM. FOR ALL OTHER ROC VALUES THE

MAXIMUM UNDERCUT IS GIVEN IN TABLE A-I.

TABLE A-I – MAXIMUM UNDERCUT ALLOWANCE

ROC (mm) 7 8 9 10 11 12

Undercut(nm) 125 125 125 125 115 106

ROC (mm) 13 14 15 16 17 18

Undercut(nm) 98 91 85 80 75 72

ROC (mm) 19 20 21 22 23 24

Undercut(nm) 68 65 62 59 56 53

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 13

A.2 OPTICAL INSERTION LOSS MEASUREMENTS

NOTE: FOR SINGLE MODE FIBER MEASUREMENTS, THE REFERENCE CABLE MAY INCLUDE A

SINGLE LOOP WITH A DIAMETER OF 30 MILLIMETERS (1 INCH) TO ELIMINATE HIGHER

ORDER MODE POWER.

NOTE: THE TIME DELAY BETWEEN THE MEASUREMENT OF P1 AND P2 SHALL BE KEPT TO A

MINIMUM TO PREVENT INACCURATE READINGS.

NOTE: THE REFERENCE CABLE TO LIGHT SOURCE CONNECTION SHALL NOT BE DISTURBED

BETWEEN THE MEASUREMENT OF P1 AND P2 TO PREVENT INACCURATE READINGS.

NOTE: A WIPE DAMPENED WITH ALCOHOL MAY BE USED TO CLEAN THE ADAPTERS AND

CONNECTORS AND THEY MAY BE BLOWN DRY WITH AIR BEFORE MAKING EACH

CONNECTION.

NOTE: THIS PROCEDURE INVOLVES THE USE OF REFERENCE MQJs. DEFECTIVE OR DIRTY

MQJs WILL LEAD TO UNACCEPTABLE LOSS VALUES. THE REFERENCE MQJ SHOULD BE

CLEAN AND OF KNOWN QUALITY.

TABLE A-II – SUMMARY OF PASS/FAIL CRITERIA

Test performed Pass/Fail criteria

Evaluate workmanship See evaluation process for details

Visual exam See evaluation process for details

Interferometer measurements GR-326 criteria for multimode and single mode

Insertion loss of ST and LC connectors

Mean: 0.35 dB Standard deviation multimode: 0.05 max Standard deviation single mode: 0.10 max

Insertion loss of termini (M29504/14 or M29504/15)

Mean: 0.7 dB Standard Deviation multimode: 0.05 max Standard Deviation single mode: 0.10 max

Return loss (Single Mode Only) 43 dB or better

A.2.1 ST-TO-LIGHT DUTY CONNECTOR (ST OR LC) MQJs:

A.2.1.1 MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR ENDS AS FOLLOWS (SEE FIGURES

A-1 AND A-2 BELOW)

a. REFERENCE MEASUREMENT (P1)

i. SELECT AN MQJ REFERENCE CABLE

NOTE: SELECT AN MQJ THAT COMPLIES WITH MIL-STD-2042-6C METHOD 6F1: MQJ

CABLE SELECTION TEST

ii. CONNECT END “A” (ST) OF THE ST TO LIGHT DUTY CONNECTOR (ST/LC)

REFERENCE MQJ TO THE LIGHT SOURCE

iii. CONNECT END “B” (ST OR LC) OF THE ST TO LIGHT DUTY CONNECTOR (ST/LC)

REFERENCE MQJ TO THE POWER METER

iv. RECORD THE OPTICAL POWER AT THE METER AS P1 (SEE FIGURE A-1)

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

SCALE: NONE UCI WT GRP SHEET 14

b. TEST MEASUREMENT (P2)

i. DISCONNECT END “B” OF THE REFERENCE MQJ FROM THE POWER METER

ii. CONNECT END “B” OF THE REFERENCE MQJ TO A ST-TO-ST OR LC-TO-LC ADAPTER

iii. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-TO-ST OR LC–TO-LC

ADAPTER

iv. CONNECT END “B” OF THE MQJ UNDER TEST TO THE OPPOSITE END OF THE MQJ

UNDER TEST TO THE POWER METER

v. RECORD THE OPTICAL POWER AS P2 (SEE FIGURE A-2)

c. CALCULATE THE LIGHT DUTY CONNECTOR (ST/LC) CONNECTOR, OF THE MQJ UNDER

TEST, END “A” OPTICAL LOSS AS P1- P2

d. RECORD THE OPTICAL LOSS VALUE

e. MEASURE THE OPTICAL LOSS OF THE LIGHT DUTY CONNECTOR (ST/LC) CONNECTOR A

MINIMUM OF TWO ADDITIONAL TIMES (MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND

MATE THE ST CONNECTORS (REFERENCE MQJ LIGHT DUTY CONNECTOR (ST/LC) AND

MQJ UNDER TEST LIGHT DUTY CONNECTOR (ST/LC)) BETWEEN EACH MEASUREMENT.

NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING.

f. THE LIGHT DUTY CONNECTOR (ST/LC) OF THE MQJ UNDER TEST IS ACCEPTABLE IF

THE AVERAGE OF THE OPTICAL LOSS MEASUREMENTS IS < 0.35 DB AND THE

STANDARD DEVIATION IS 0.05 OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE

MODE. NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.35 DB.

g. REPEAT PROCEDURE TO MEASURE THE CONNECTOR LOSS ON THE OTHER END OF

THE MQJ UNDER TEST

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

SCALE: NONE UCI WT GRP SHEET 15

FIGURE A-1 - REFERENCE MEASUREMENT (P1)

FIGURE A-2 - TEST MEASUREMENT (P2)

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 16

A.2.2 ST-TO-MULTI-TERMINUS CONNECTOR MQJs

A.2.2.1 MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR ENDS AS FOLLOWS

i. CONNECT END “A” (ST CONNECTOR END) OF THE REFERENCE MQJ (DESIGNATED

MQJ 2) TO THE OPTICAL SOURCE.

NOTE: METHOD IS WRITTEN FOR MQJ UNDER TEST BEING A PLUG MQJ. IF MQJ UNDER TEST

IS A RECEPTACLE MQJ THEN THE REFERENCE MQJ WILL NEED TO SWITCH TO A PLUG

MQJ.

ii. CONNECT END “B” OF MQJ 2, THE END OPPOSITE THE LIGHT SOURCE, TO END “B”

(MULTI-TERMINUS END) OF THE MQJ UNDER TEST

iii. CONNECT END “A” (ST END) OF THE MQJ UNDER TEST TO THE POWER METER

iv. RECORD THE OPTICAL POWER AS P1 (SEE FIGURE A-3)

b. TEST MEASUREMENT (P2)

i. DISCONNECT END “A” OF THE MQJ UNDER TEST FROM THE POWER METER

ii. CONNECT END “A” (ST CONNECTOR END) OF THE MQJ UNDER TEST TO A ST-TO-ST

ADAPTER

iii. CONNECT END “A” OF MQJ 1 (REFERENCE ST-TO-ST MQJ) TO THE ST-TO-ST

ADAPTER

iv. CONNECT THE OPPOSITE END OF MQJ 1 TO THE POWER METER

v. RECORD THE OPTICAL POWER AS P2 (SEE FIGURE A-4)

c. CALCULATE THE ST CONNECTOR OPTICAL LOSS AS P1- P2

d. RECORD THE OPTICAL LOSS VALUE

e. MEASURE THE OPTICAL LOSS OF THE ST CONNECTOR A MINIMUM OF TWO

ADDITIONAL TIMES (MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND MATE THE ST

CONNECTORS (MQJ 1 ST AND MQJ UNDER TEST ST) BETWEEN EACH MEASUREMENT.

NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING

f. THE ST CONNECTOR OF THE MQJ UNDER TEST IS ACCEPTABLE IF THE AVERAGE OF

THE OPTICAL LOSS MEASUREMENTS IS < 0.35 DB AND THE STANDARD DEVIATION IS

0.05 OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE MODE.

NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.35 DB

g. REPEAT STEPS ‘A’ THROUGH ‘F’ FOR EACH CHANNEL OF THE MQJ

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

SCALE: NONE UCI WT GRP SHEET 17

FIGURE A-3 - REFERENCE MEASUREMENT (P1)

1. LIGHT SOURCE (MM – USE LED SOURCE, SM – USE LASER)

2. MQJ 2 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM, SM – USE

SME MQJ)

3. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)

4. POWER METER

FIGURE A-4 - TEST MEASUREMENT (P2)

1. LIGHT SOURCE (MM- USE LED SOURCE, SM – USE LASER)

2. MQJ 2 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM, SM – USE

SME MQJ)

3. POWER METER

4. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)

5. MQJ 1 = ST TO ST REFERENCE MQJ (MM-USE MM, SM- USE SME MQJ)

A.2.3 MEASURE THE OPTICAL LOSS OF THE TERMINI

NOTE: THIS MEASUREMENT IS DONE OVER THE TERMINUS INTERFACE AT END “B” OF THE MQJ

UNDER TEST

NOTE: THIS MEASUREMENT INVOLVES A SUBSTITUTION OF THE MQJ FROM THE REFERENCE

MEASUREMENT TO THE TEST MEASUREMENT

NOTE: THIS METHOD IS WRITTEN FOR THE MQJ UNDER TEST BEING A PLUG MQJ. IF THE MQJ

UNDER TEST IS A RECEPTACLE MQJ THEN THE REFERENCE MQJ WILL NEED TO SWITCH TO

A PLUG MQJ.

i. CONNECT TWO REFERENCE ST-TO-ST MQJs (DESIGNATED MQJ 1 AND MQJ 2)

BETWEEN THE LIGHT SOURCE AND POWER METER. (SEE FIGURE A-5)

ii. RECORD THE OPTICAL POWER AS P1

b. TEST MEASUREMENT (P2)

i. DISCONNECT MQJ 2 FROM MQJ 1 AND THE POWER METER

ii. CONNECT END “A” (ST CONNECTOR END) OF A REFERENCE MQJ (DESIGNATED MQJ

3) TO MQJ 1, THE END OPPOSITE THE LIGHT SOURCE. (SEE FIGURE A-6)

End B End A

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 18

iii. CONNECT END “B” OF MQJ 3, THE END OPPOSITE THE LIGHT SOURCE, TO END “B”

OF THE MQJ UNDER TEST. (SEE FIGURE A-6)

iv. CONNECT END “A” (ST END) OF THE MQJ UNDER TEST TO THE POWER METER (SEE

FIGURE A-6)

v. RECORD THE OPTICAL POWER AS P2

c. CALCULATE THE OPTICAL LOSS AS P1- P2

d. RECORD THE OPTICAL LOSS VALUE

e. MEASURE THE OPTICAL LOSS OF THE TERMINI A MINIMUM OF TWO ADDITIONAL TIMES

(MAXIMUM OF 10 TOTAL TIMES). DE-MATE AND MATE THE TERMINI (ASSEMBLY) (MQJ 3

AND MQJ UNDER TEST ST) BETWEEN EACH MEASUREMENT.

NOTE: DE-MATED CONNECTORS SHALL BE CLEANED PRIOR TO RE-MATING

f. THE TERMINI OF THE MQJ UNDER TEST IS ACCEPTABLE IF THE AVERAGE OF THE

OPTICAL LOSS MEASUREMENTS IS < 0.70 DB AND THE STANDARD DEVIATION IS 0.05

OR BETTER FOR MULTIMODE AND 0.1 FOR SINGLE MODE

NOTE: NO INDIVIDUAL MEASUREMENT SHALL BE GREATER THAN 0.70 DB

g. REPEAT STEPS A THROUGH F FOR EACH CHANNEL OF THE MQJ

h. REPEAT PROCEDURE WITH THE RECEPTACLE AS THE MQJ UNDER TEST AND MQJ

PLUG AS MQJ 3

FIGURE A-5 - REFERENCE MEASUREMENT (P1)

1. LIGHT SOURCE (MM-USE LED, SM – USE LASER)

2. MQJ 1 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)

3. POWER METER

4. ST TO ST ADAPTER

5. MQJ 2 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)

FIGURE A-6 - TEST MEASUREMENT (P2)

1. LIGHT SOURCE (MM-USE LED, SM – USE LASER)

2. MQJ 3 = ST TO CONNECTOR WITH TERMINI REFERENCE MQJ (MM – USE MM MQJ,

SM – USE SME MQJ)

3. POWER METER

4. MQJ UNDER TEST (ST TO CONNECTOR WITH TERMINI)

5. MQJ 1 = ST TO ST REFERENCE MQJ (MM – USE MM MQJ, SM – USE SME MQJ)

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 19

TABLE A-4 - MQJ OPTICAL LOSS ACCEPTANCE CRITERIA

END CONNECTION ACCEPTABLE LOSS (DB)

1/

STANDARD DEVIATION

(DB)

ST 0.00 < ΜC < 0.35

0.05 MAX. (MULTIMODE)

0.10 MAX. (SINGLE MODE)

LC 0.00 < ΜC < 0.35

0.05 MAX. (MULTIMODE)

0.10 MAX. (SINGLE MODE)

M29504/14 PIN TERMINUS 0.00 < ΜC < 0.70

0.05 MAX. (MULTIMODE)

0.10 MAX. (SINGLE MODE)

M29504/15 SOCKET TERMINUS 0.00 < ΜC < 0.70

0.05 MAX. (MULTIMODE)

0.10 MAX. (SINGLE MODE)

1/ WHERE ΜC IS THE MEAN CONNECTION LOSS

A.3 OPTICAL RETURN LOSS MEASURING

NOTE: OPTICAL RETURN LOSS TESTING IS ONLY PERFORMED ON SINGLE MODE MQJs

NOTE: USE ENHANCED DOME POLISH REFERENCE MQJs WITH RETURN LOSS

REQUIREMENTS NOT LESS THAN 43 DB

A.3.1 ST-TO-LIGHT DUTY (ST OR LC) CONNECTOR MQJs

NOTE: SELECT THE 1310 NANOMETER WAVELENGTH IF THE ORLM CAN PERFORM RETURN LOSS

MEASUREMENTS AT MULTIPLE WAVELENGTHS

a. REFERENCE THE ORLM

b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ

FROM THE MANDREL

c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9

d. CONNECT END “B”, END OPPOSITE ORLM, OF THE REFERENCE MQJ TO A ST-ST OR

LC-TO-LC ADAPTER

e. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-ST OR LC-TO-LC ADAPTER

f. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, BEHIND THE ST MATED

PAIR, AND RECORD THE DATA

NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A STABLE

VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE USUALLY

SUFFICIENT TO OBTAIN A STABLE VALUE.

g. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB

h. REPEAT STEPS ‘E’ THRU ‘F’ WITH END “B” OF THE MQJ UNDER TEST CONNECTED TO

THE ST END OF THE REFERENCE MQJ

A.3.2 ST-TO-MULTI-TERMINUS CONNECTOR MQJs

NOTE: SELECT THE 1310 NANOMETER WAVELENGTH IF THE ORLM CAN PERFORM RETURN LOSS

MEASUREMENTS AT MULTIPLE WAVELENGTHS

A.3.2.1 MEASURE THE OPTICAL RETURN LOSS OF THE ST CONNECTOR ENDS

a. REFERENCE THE ORLM

b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ

FROM THE MANDREL

c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9

d. CONNECT END “B”, END OPPOSITE ORLM, OF THE REFERENCE MQJ TO A ST-ST

ADAPTER

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

G

SCALE: NONE UCI WT GRP SHEET 20

e. CONNECT END “A” OF THE MQJ UNDER TEST TO THE ST-ST ADAPTER

f. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, BEHIND THE ST MATED

PAIR, AND RECORD THE DATA

NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A

STABLE VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE

USUALLY SUFFICIENT TO OBTAIN A STABLE VALUE. REPEAT STEPS “E” THROUGH “F”

FOR THE REMAINING CHANNELS OF THE MQJ UNDER TEST.

g. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB

h. REPEAT STEPS ‘E’ THROUGH ‘G’ FOR ALL CHANNELS

A.3.2.2 MEASURE THE OPTICAL RETURN LOSS OF THE TERMINI ENDS

a. CONNECT ST-ST REFERENCE MQJ TO ORLM, AND THEN CONNECT ST OF ST- M28876

REFERENCE MQJ TO THE ST-ST REFERENCE MQJ AND REFERENCE ORLM BY

MANDREL WRAPPING ST-M28876 REFERENCE MQJ

b. WHEN THE REFERENCING PROCESS IS COMPLETE, UNWRAP THE REFERENCE MQJ

FROM THE MANDREL

c. VERIFY THAT THE ORLM IS DISPLAYING A VALUE BETWEEN 14.3 AND 15.9

d. CONNECT THE TERMINI END OF THE MQJ UNDER TEST TO THE TERMINI END OF ST-

M28876 REFERENCE MQJ

e. WRAP THE MQJ UNDER TEST AROUND A 6 MM MANDREL, NEAR THE ST END, AND

RECORD THE DATA (SEE FIGURE A-8)

NOTE: THE MQJ UNDER TEST SHOULD BE WRAPPED AROUND THE MANDREL UNTIL A

STABLE VALUE IS INDICATED ON THE ORLM DISPLAY. TEN MANDREL WRAPS ARE

USUALLY SUFFICIENT TO OBTAIN A STABLE VALUE.

f. THE RETURN LOSS VALUE FOR SME MQJs SHALL BE GREATER THAN 43 DB

g. REPEAT STEPS ‘M’ THROUGH ‘N’ FOR ALL CHANNELS

FIGURE A-7 - ORLM REFERENCE SETUP

W

V S

E A

D R

A W

IN

G

N O

S

CAGE

53711

REV

SCALE: NONE UCI WT GRP SHEET 21

FIGURE A-8 - ORLM TEST SETUP

File details come from the government source that posted it.