High_Voltage_Pulse_Generator_-_SOW_Bidding_Updated.docx
DOCX document 34 KB Posted
- Attached to
- Electric Wire & Power Distribution Equipment
- Solicitation number
- N0017814R4185
About this file
SOW
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DI-TMSS-81815_Bidding.pdf | ||
| CDRL_A001_Bidding.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HIGH VOLTAGE PULSE AMPLIFIER
STATEMENT OF WORK (SOW)
1.0 INTRODUCTION
NSWCDD requires a modern solid-state equivalent pulse amplifier. A single design consisting of available parts will consolidate parts management and simplify maintenance procedures. Replacement of vacuum-tube active elements with more rugged solid-state equivalents will reduce the need for frequent downtime due to repair.
| 2.0 | APPLICABLE DOCUMENTS |
| 2.1 | Original Equipment Manufacturer (OEM) Specifications |
| 3.0 | REQUIREMENTS |
The contactor shall provide five (5) High Voltage Pulse Amplifiers per the performance specifications as follows:
Output Pulse Voltage: 0 - 3000 Volts
Output Pulse Current: 0 - 15 Amps
Pulse Width: 0.2 - 200 Microseconds
Pulse Repetition Rate: One Shot - 5000 Hz
Duty Cycle: ≥ 2%
Pulse Rise Time: ≤ 110 Nanoseconds for less than 500pF load ≤ 4 Microseconds for less than 20,000pF load
Pulse Fall Time: ≤ 110 Nanoseconds for less than 500pF load ≤ 4 Microseconds for less than 20,000pF load
Droop: < 0.005% per Microsecond at 15 Amps
Overshoot: < 5%
Propagation Delay: ≤ 500 Nanoseconds
Pulse Width Distortion: ≤ 50 Nanosecond
Floating Output Isolation: 5000 Volts D.C.
Pulse Input: BNC Connector / TTL
Amplitude Control: BNC Connector / 0 – 10 Volt Analog Level with Linear Response
Voltage View: BNC Connector / 1:1000 Volts
Current View: BNC Connector
Input Power: 115 / 208 Volts, 60 Hz
Rack Mount Size: 17” Wide x 20” Deep x 14” High Maximum Dimensions
| 3.1 | The contractor shall provide 14 day notification to the technical point of contact (TPOC), identified at time of award, prior to verification testing. |
| 3.2 | The contractor shall provide quality testing and verification at the manufacturer’s site to be witnessed by Q52, NSWCDD personnel identified by the TPOC. |
| 3.3 | The contractor shall ensure the following during testing: |
| 3.3.1 | The output of the pulse amplifier shall be attached to a 200 Ohm non-inductive load. |
| 3.3.2 | Calibrated voltage and current probes shall be attached to verify specifications. |
| 3.3.3 | Verify maximum pulse width at 2% duty. |
| 3.3.4 | Verify maximum pulse repetition frequency at 2% duty. |
| 3.3.5 | Verify minimum pulse width. |
| 3.3.6 | Verify voltage and current view signal accuracy. |
| 3.4 | The contractor shall ship the unit to NSWCDD once the equipment passes quality testing and verification. |
| 4.0 | DELIVERABLES |
The contractor shall provide component level schematics and parts list (CDRL A001).
5.0 TECHNICAL POINTS OF CONTACT (TPOC)
To be provided at time of award
File details come from the government source that posted it. Updated .