This document is a solicitation amendment for the ECMP 228 Small Rocket Blaster System Solicitation (Solicitation Number N0017424SN0075). The amendment provides responses to questions received regarding the current compressed air supply, electrical power, abrasive media, blast pressure, and blast nozzle details for the existing automated blast machine. It also extends the solicitation closing date from September 12, 2024 to September 16, 2024. The contract will be a Firm Fixed Price supply contract for a one-time purchase with no options. The NAICS code is 332322, and the PSC is 3426. Interested sources must submit their responses by the new deadline of 2:00 pm EST on September 16, 2024.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to 1) answ er questions received in response to the solicitation posting and 2) extend the solicitation closing date.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 10-Sep-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N0017424R0135
X 9B. DATED (SEE ITEM 11)
06-Aug-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
10-Sep-2024
CODE
NSWC IHD C02
4081 N. JACKSON RD
BLDG 841
INDIAN HEAD MD 20640-5116
N00174 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SUMMARY OF CHANGES_
The purpose of this amendment is to 1) answer questions received in response to the solicitation posting and 2) extend the solicitation closing date as follows:
Question 1: What is the current compressed air supply available (cfm rating at 100 psi)? Can you provide the manufacturers name, model number, serial number, and horsepower rating for the air compressor that is currently used for the existing automated blast machine?
Answer 1: Compressed Air Dryer Specs
Rated capacity: 165 SCFM at 100 psi
Manufacturer: Kaeser Kompressoren
Model Number: KLD-165
Serial Number: 3334-2-9808-13KD
Horsepower Rating: N/A (Dryer has power rating of 49.4 W presumably for electronics/human machine interface)
We highly recommend replacing the compressed air dryer.
Question 2: What is the voltage currently feeding the existing automated blast machine? 480 volt/3 phase or other?
Answer 2: 480 volt/3 phase is feeding the existing automated blast machine.
Question 3: What is the current media and media size being used for your current process?
Answer 3: Currently use Blastite BT (96-100% Al2O3, 0-3% TiO2) with ANSI Grit Size 24 from Washington Mills.
Question 4: Is there a defined surface profile you are trying to achieve and that we should be required to meet?
Answer 4: No defined surface profile, looking for rough surface throughout the inner surface of the part.
Question 5: What blast pressure are you blasting at in your current process?
Answer 5: Typically 75 psi, can range from 65-75 psi.
Question 6: Can you provide the model number and part number for the blast nozzle you are currently using for your existing process?
Answer 6: Surface Blasting Systems (SBS) Part Number 0400214S. No model number as it is a custom part.
Question 7: What is your current/average time cycle for your existing blasting process per part?
Answer 7: 4-6 minutes per part.
Question 8: Any chance you would be able to supply pictures of the concrete pad and surrounding area where the Dust Collector would go outside? Also, could you have a picture of the door where the machine/rigging equipment would need to go through to carry the machine into place? Finally, would you be able to supply a few pictures of where the machine will be located in order to see any possible hazards (pipes, beams, etc.)?
Answer 8: Due to timing and the security review/approval process for releasing photos, photos cannot be provided. Dimensions are provided below.
Dimensions for the concrete pad outside where the Dust Collector would be placed were previously provided. The concrete pad dimensions are 15 feet (length) x 7.5 feet (width).
Dimensions for the double door into the bay are 10 feet (height) x 6 feet (width).
Dimensions for the space for the machine were previously provided. The grit blaster and associated equipment needs to fit within a space of about 25 feet (length) x 12.5 feet (width) x 15 feet (height) inside the building. The dimensions given ensure that no beams, pipes, etc. interfere with the design.
Question 9: Can we get an extension for submission of bids till September 16, 2024?
Answer 9: Yes, the Government will extend the bid submission deadline to 16 September 2024 2:00 pm EST.
2. The solicitation closing date is extended
FROM:
12 September 2024 2:00 pm EST
TO:
16 September 2024 2:00 pm EST
3. All other items remain unchanged.
4. Direct questions to Diane Hicks at diane.d.hicks.civ@us.navy.mil .