g1950srva8001.txt
TXT text file 67 KB Posted
- Solicitation number
- N00173-23-Q-0711
Text of this file
g1950srva8001::> system controller config show
Node: g1950srva8001-01
Sub- Device/ Slot slot Information
- - System NetApp Release 9.10.1P12: Wed Apr 12 20:30:59 EDT 2023 System ID: 0538149098 (g1950srva8001-01); partner ID: 0538148669 (g1950srva8001-02) System Serial Number: 722021000056 (g1950srva8001-01) System Rev: A5 System Storage Configuration: Multi-Path HA System ACP Connectivity: Inband Active All-Flash Optimized: false Capacity Optimized: false All SAN Array: false Backplane Part Number: 111-02495 Backplane Rev: A5 Backplane Serial Number: 042004003538 0 - Controller Module
1.7 GHz (System Board XXII E1)
Model Name: FAS8200 Part Number: 111-02493 Revision: E1 Serial Number: 042006003539 BIOS version: 11.20 Loader version: 6.0.17 Processors: 16 Processor ID: 0x50664 Microcode Version: 0xf00001a Processor type: Intel(R) Xeon(R) CPU D-1587 @ 1.70GHz Memory Size: 131072 MB Memory Attributes: Hoisting Rank Interleaving CHannel Interleaving Chipkill ECC NVMEM Size: 8190 MB of Main Memory Used Controller: A PCIE Switch 0: id 0 519 1.05 PCIE Switch 1: id 1 519 1.08 TPM FW Version: 5.63.3353.0 0 - Service Processor Service Processor Status: Online Firmware Version: 5.11 Mgmt MAC Address: D0:39:EA:19:A9:5F Ethernet Link: up, full duplex, auto-neg complete Using DHCP: no IPv4 configuration:
IP Address: 10.0.81.129 Netmask: 255.255.254.0 Gateway: 10.0.80.1 IPv6 configuration: Disabled [Service Processor cached network information determined at Wed May 24 15:58:24 UTC 2023] 0 - Internal 10/100/1000 Ethernet Switch Wrench: auto-1000t-fd-up Device Type: 88E6176 0 - Gigabit Ethernet I210 e0M MAC Address: d0:39:ea:19:a9:5d (auto-1000t-fd-up) Device Type: 0x1533 (BSD99) Firmware Version: 3.25-5.5 0x80000674 0 - 10 Gigabit Ethernet Controller IX5-SFP+ e0a MAC Address: d0:39:ea:19:a9:4d (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340039 e0b MAC Address: d0:39:ea:19:a9:4e (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340050 Device Type: X550EM(0x15AC) (BSD99) Firmware Version: 1.13-5.1
Node: g1950srva8001-01
Sub- Device/ Slot slot Information
0 - 1/10 Gigabit Ethernet Controller IX4-T e0c MAC Address: d0:39:ea:19:a9:4f (auto-unknown-fd-down) e0d MAC Address: d0:39:ea:19:a9:50 (auto-unknown-fd-down) Device Type: X550(0x1563) (BSD99) rev1 Firmware Version: 1.0-5.1
0 - 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2) e0f MAC Address: d2:39:ea:19:a9:5d (auto-10g_sr-fd-up) e0e MAC Address: d2:39:ea:19:a9:5d (auto-10g_sr-fd-up) e0h MAC Address: d0:39:ea:19:a9:54 (auto-unknown-fd-down) e0g MAC Address: d0:39:ea:19:a9:53 (auto-unknown-fd-down) Device Type: EP8324N Firmware Version: 5.4.66.0
0 - PLX PCIe DMA PLX DMA Engine: 2 PLX: 0x87d0 State: Active
0 - PLX NTB
Device Name: Interconnect HBA: Generic OFED Provider Port Name: ic0a Default GID: fe80:0000:0000:0000:0000:0000:0000:0104 Base LID: 0x104 Active MTU: 8192 Max HW Data Rate: PCIe Gen 3 x 8 HW Data Rate: PCIe Gen 3 x 8 SW Data Rate: PCIe Gen 3 x 8 Logical Link: Up Port State: Enabled 0 - PLX PCIe DMA
0 - PMC SAS/SATA Controller 8072 SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1dea:70 Temperature: Not Available Phy State: [12] Enabled, 12.0 Gb/s [13] Enabled, 12.0 Gb/s [14] Enabled, 12.0 Gb/s [15] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Molex Inc.
Mini-SAS HD Part Number: 112-00435+A0 Mini-SAS HD Type: Passive Copper (unequalized) 0.5m ID:00 Mini-SAS HD Serial Number: 005630466 SAS Host Adapter 0b (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1dea:74 Temperature: Not Available Phy State: [8] Disabled [9] Disabled [10] Disabled [11] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1dea:78 Temperature: Not Available Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0d (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1dea:7c Temperature: Not Available Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available
Node: g1950srva8001-01
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0e Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:84:80:e3:80:ea Connection: No link Switch Port: Unknown SFP Vendor Name: PROLINE SFP Vendor P/N: SFP-10G-SR-CDW SFP Vendor Rev.: 2.0 SFP Serial No.: EB120703094 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec
Node: g1950srva8001-01
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0f Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:83:80:e3:80:ea Connection: No link Switch Port: Unknown SFP Vendor Name: PROLINE SFP Vendor P/N: SFP-10G-SR-CDW SFP Vendor Rev.: 2.0 SFP Serial No.: E1304261567 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0g Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:86:80:e3:80:ea Connection: No link Switch Port: Unknown 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0h Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:85:80:e3:80:ea Connection: No link Switch Port: Unknown 0 - Intel Broadwell SATA Controller Additional Info: u0a (0x90710000) SV9MST6D120GLM41NP FW1122 114473MB 512B/sect (SPG20060ATX) 0 - Intel Broadwell USB2 Enhanced Host Controller
1 - Dual-port 10G Ethernet Controller CNA ISP 8324 (Dual-port, QLogic CNA 8324(8362) rev. 2) e1a MAC Address: 34:80:0d:78:37:00 (auto-unknown-fd-down) e1b MAC Address: 34:80:0d:78:37:08 (auto-unknown-fd-down) Device Type: ISP8324N Firmware Version: 5.4.66.0 Serial Number: 34800D783700
Node: g1950srva8001-01
Sub- Device/ Slot slot Information 1 - QLogic ISP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 1a Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 1.1.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:81:80:e3:80:ea Connection: No link Switch Port: Unknown 1 - QLogic ISP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 1b Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 1.1.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:e3:80:ea FC Portname: 50:0a:09:82:80:e3:80:ea Connection: No link Switch Port: Unknown 2 - PMC SAS/SATA Controller 8072 SAS Host Adapter 2a (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G3001DB Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f089:00 Temperature: 38 C Phy State: [12] Disabled [13] Disabled [14] Disabled [15] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 2b (PMC-Sierra PM8072 rev. C, SAS, <UP>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G3001DB Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f089:04 Temperature: 38 C Phy State: [8] Enabled, 12.0 Gb/s [9] Enabled, 12.0 Gb/s [10] Enabled, 12.0 Gb/s [11] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Molex Inc.
Mini-SAS HD Part Number: 112-00437+A0 Mini-SAS HD Type: Passive Copper (unequalized) 2m ID:00 Mini-SAS HD Serial Number: 006530235 SAS Host Adapter 2c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G3001DB Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f089:08 Temperature: 38 C Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 2d (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G3001DB Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f089:0c Temperature: 38 C Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available
Node: g1950srva8001-01
Sub- Device/ Slot slot Information 3 - Flash Cache NVMe Serial Number: S46YNA0N201802 Part Number: 119-00329 Hardware Revision: B0 Firmware Version: NA01 Firmware File: X3311_S000PM983NVM Model Name: X3311A Capacity: 1024 GB State: ok Node: g1950srva8001-02
Sub- Device/ Slot slot Information
- - System NetApp Release 9.10.1P12: Wed Apr 12 20:30:59 EDT 2023 System ID: 0538148669 (g1950srva8001-02); partner ID: 0538149098 (g1950srva8001-01) System Serial Number: 722021000055 (g1950srva8001-02) System Rev: A5 System Storage Configuration: Multi-Path HA System ACP Connectivity: Inband Active All-Flash Optimized: false Capacity Optimized: false All SAN Array: false Backplane Part Number: 111-02495 Backplane Rev: A5 Backplane Serial Number: 042004003538
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 0 - Controller Module
1.7 GHz (System Board XXII E1)
Model Name: FAS8200 Part Number: 111-02493 Revision: E1 Serial Number: 042006003210 BIOS version: 11.20 Loader version: 6.0.17 Processors: 16 Processor ID: 0x50664 Microcode Version: 0xf00001a Processor type: Intel(R) Xeon(R) CPU D-1587 @ 1.70GHz Memory Size: 131072 MB Memory Attributes: Hoisting Rank Interleaving CHannel Interleaving Chipkill ECC NVMEM Size: 8190 MB of Main Memory Used Controller: B PCIE Switch 0: id 0 519 1.05 PCIE Switch 1: id 1 519 1.08 TPM FW Version: 5.63.3353.0 0 - Service Processor Service Processor Status: Online Firmware Version: 5.11 Mgmt MAC Address: D0:39:EA:19:85:CB Ethernet Link: up, full duplex, auto-neg complete Using DHCP: no IPv4 configuration:
IP Address: 10.0.81.148 Netmask: 255.255.254.0 Gateway: 10.0.80.1 IPv6 configuration: Disabled [Service Processor cached network information determined at Wed May 24 15:57:24 UTC 2023] 0 - Internal 10/100/1000 Ethernet Switch Wrench: auto-1000t-fd-up Device Type: 88E6176 0 - Gigabit Ethernet I210 e0M MAC Address: d0:39:ea:19:85:c9 (auto-1000t-fd-up) Device Type: 0x1533 (BSD99) Firmware Version: 3.25-5.5 0x80000674 0 - 10 Gigabit Ethernet Controller IX5-SFP+ e0a MAC Address: d0:39:ea:19:85:b9 (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340095 e0b MAC Address: d0:39:ea:19:85:ba (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340048 Device Type: X550EM(0x15AC) (BSD99) Firmware Version: 1.13-5.1
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 0 - 1/10 Gigabit Ethernet Controller IX4-T e0c MAC Address: d0:39:ea:19:85:bb (auto-unknown-fd-down) e0d MAC Address: d0:39:ea:19:85:bc (auto-unknown-fd-down) Device Type: X550(0x1563) (BSD99) rev1 Firmware Version: 1.0-5.1
0 - 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2) e0f MAC Address: d2:39:ea:19:85:c9 (auto-10g_sr-fd-up) e0e MAC Address: d2:39:ea:19:85:c9 (auto-10g_sr-fd-up) e0h MAC Address: d0:39:ea:19:85:c0 (auto-unknown-fd-down) e0g MAC Address: d0:39:ea:19:85:bf (auto-unknown-fd-down) Device Type: EP8324N Firmware Version: 5.4.66.0
0 - PLX PCIe DMA PLX DMA Engine: 2 PLX: 0x87d0 State: Active
0 - PLX NTB
Device Name: Interconnect HBA: Generic OFED Provider Port Name: ic0a Default GID: fe80:0000:0000:0000:0000:0000:0000:0105 Base LID: 0x105 Active MTU: 8192 Max HW Data Rate: PCIe Gen 3 x 8 HW Data Rate: PCIe Gen 3 x 8 SW Data Rate: PCIe Gen 3 x 8 Logical Link: Up Port State: Enabled 0 - PLX PCIe DMA
0 - PMC SAS/SATA Controller 8072 SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1d71:c0 Temperature: Not Available Phy State: [12] Enabled, 12.0 Gb/s [13] Enabled, 12.0 Gb/s [14] Enabled, 12.0 Gb/s [15] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Molex Inc.
Mini-SAS HD Part Number: 112-00435+A0 Mini-SAS HD Type: Passive Copper (unequalized) 0.5m ID:00 Mini-SAS HD Serial Number: 005630475 SAS Host Adapter 0b (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1d71:c4 Temperature: Not Available Phy State: [8] Disabled [9] Disabled [10] Disabled [11] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1d71:c8 Temperature: Not Available Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0d (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e1d71:cc Temperature: Not Available Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0e Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:84:80:b3:7f:3d Connection: No link Switch Port: Unknown SFP Vendor Name: CISCO-EQUIV SFP Vendor P/N: SFP-10G-SR-IL SFP Vendor Rev.: B4 SFP Serial No.: ZZWH9035 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0f Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:83:80:b3:7f:3d Connection: No link Switch Port: Unknown SFP Vendor Name: CISCO-EQUIV SFP Vendor P/N: SFP-10G-SR-IL SFP Vendor Rev.: B4 SFP Serial No.: ZZWH9022 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0g Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:86:80:b3:7f:3d Connection: No link Switch Port: Unknown 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0h Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 5.0.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:85:80:b3:7f:3d Connection: No link Switch Port: Unknown 0 - Intel Broadwell SATA Controller Additional Info: u0a (0x90710000) SV9MST6D120GLM41NP FW1122 114473MB 512B/sect (SPG2006099M) 0 - Intel Broadwell USB2 Enhanced Host Controller
1 - Dual-port 10G Ethernet Controller CNA ISP 8324 (Dual-port, QLogic CNA 8324(8362) rev. 2) e1a MAC Address: 34:80:0d:78:36:d0 (auto-unknown-fd-down) e1b MAC Address: 34:80:0d:78:36:d8 (auto-unknown-fd-down) Device Type: ISP8324N Firmware Version: 5.4.66.0 Serial Number: 34800D7836D0
1 - QLogic ISP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 1a Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 1.1.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:81:80:b3:7f:3d Connection: No link Switch Port: Unknown 1 - QLogic ISP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 1b Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 1.1.2 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:b3:7f:3d FC Portname: 50:0a:09:82:80:b3:7f:3d Connection: No link Switch Port: Unknown
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 2 - PMC SAS/SATA Controller 8072 SAS Host Adapter 2a (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G300226 Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f14e:00 Temperature: 39 C Phy State: [12] Disabled [13] Disabled [14] Disabled [15] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 2b (PMC-Sierra PM8072 rev. C, SAS, <UP>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G300226 Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f14e:04 Temperature: 39 C Phy State: [8] Enabled, 12.0 Gb/s [9] Enabled, 12.0 Gb/s [10] Enabled, 12.0 Gb/s [11] Enabled, 12.0 Gb/s Mini-SAS HD Vendor: Molex Inc.
Mini-SAS HD Part Number: 112-00437+A0 Mini-SAS HD Type: Passive Copper (unequalized) 2m ID:01 Mini-SAS HD Serial Number: 012830279 SAS Host Adapter 2c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G300226 Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f14e:08 Temperature: 39 C Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 2d (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>) MFG Part Number: Microsemi Corp. 110-03801 rev. A0 Part number: 111-03801+A0 Serial number: 0B01G300226 Date Code: 20200109 Firmware rev: 03.08.09.00 Base WWN: 5:0000d1:f00f14e:0c Temperature: 39 C Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available
Node: g1950srva8001-02
Sub- Device/ Slot slot Information 3 - Flash Cache NVMe Serial Number: S46YNA0N201464 Part Number: 119-00329 Hardware Revision: B0 Firmware Version: NA01 Firmware File: X3311_S000PM983NVM Model Name: X3311A Capacity: 1024 GB State: ok Node: g1950srva8001-03
Sub- Device/ Slot slot Information
- - System NetApp Release 9.10.1P12: Wed Apr 12 20:30:59 EDT 2023 System ID: 0538156347 (g1950srva8001-03); partner ID: 0538156517 (g1950srva8001-04) System Serial Number: 632020000305 (g1950srva8001-03) System Rev: B0 System Storage Configuration: Single-Path HA System ACP Connectivity: Inband Active All-Flash Optimized: true Capacity Optimized: false All SAN Array: false Backplane Part Number: DS22412 Backplane Rev:
Backplane Serial Number: 042002055461 0 - Controller Module
1.5 GHz (System Board XXII B0)
Model Name: AFF-A220 Part Number: 111-04333 Revision: B0 Serial Number: 042013019102 BIOS version: 11.20 Loader version: 6.0.17 Processors: 12 Processor ID: 0x50664 Microcode Version: 0xf00001a Processor type: Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz Memory Size: 32768 MB Memory Attributes: Hoisting Rank Interleaving CHannel Interleaving Mezzanine Card:
Part: 111-04160 Version: A1 Serial: 042005009580 NVMEM Size: 4094 MB of Main Memory Used Controller: A PCIE Switch 1: id 1 546 1.04 TPM FW Version: 5.63.3353.0
Node: g1950srva8001-03
Sub- Device/ Slot slot Information 0 - Service Processor Service Processor Status: Online Firmware Version: 11.9 Mgmt MAC Address: d0:39:ea:1c:9f:cd Ethernet Link: up, full duplex, auto-neg complete Using DHCP: no IPv4 configuration:
IP Address: 10.0.81.127 Netmask: 255.255.254.0 Gateway: 10.0.80.1 IPv6 configuration: Disabled [Service Processor cached network information determined at Wed May 24 15:58:09 UTC 2023] 0 - Internal 10/100/1000 Ethernet Switch Wrench: auto-1000t-fd-up Device Type: 88E6176 0 - Gigabit Ethernet I210 e0M MAC Address: d0:39:ea:1c:9f:cb (auto-1000t-fd-up) Device Type: 0x1533 (BSD99) Firmware Version: 3.25-7.5 0x80000674 0 - 10 Gigabit Ethernet Controller IX5-SFP+ e0a MAC Address: d0:39:ea:1c:9f:bd (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340105 e0b MAC Address: d0:39:ea:1c:9f:be (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340187 Device Type: X550EM(0x15AC) (BSD99) Firmware Version: 1.13-7.1
0 - 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2) e0e MAC Address: d0:39:ea:1c:9f:c1 (auto-unknown-fd-down) e0f MAC Address: d0:39:ea:1c:9f:c2 (auto-unknown-fd-down) e0c MAC Address: d2:39:ea:1c:9f:cb (auto-10g_sr-fd-up) e0d MAC Address: d2:39:ea:1c:9f:cb (auto-10g_sr-fd-up) Device Type: EP8324N Firmware Version: 5.4.66.0
Node: g1950srva8001-03
Sub- Device/ Slot slot Information
0 - PLX PCIe DMA
0 - PLX PCIe DMA PLX DMA Engine: 2 PLX: 0x87d0 State: Active
0 - PLX NTB
Device Name: Interconnect HBA: Generic OFED Provider Port Name: ic0a Default GID: fe80:0000:0000:0000:0000:0000:0000:0104 Base LID: 0x104 Active MTU: 8192 Max HW Data Rate: PCIe Gen 3 x 8 HW Data Rate: PCIe Gen 3 x 8 SW Data Rate: PCIe Gen 3 x 8 Logical Link: Up Port State: Enabled 0 - PMC SAS/SATA Controller 8070 SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e2a8f:b0 Temperature: Not Available Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e2a8f:b4 Temperature: Not Available Phy State: [4] Enabled, 12.0 Gb/s [5] Enabled, 12.0 Gb/s [6] Enabled, 12.0 Gb/s [7] Enabled, 12.0 Gb/s 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0c Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:23:9d:3b FC Portname: 50:0a:09:83:80:23:9d:3b Connection: No link Switch Port: Unknown SFP Vendor Name: PROLINE SFP Vendor P/N: SFP-10G-SR-CDW SFP Vendor Rev.: 2.0 SFP Serial No.: E1304261588 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec
Node: g1950srva8001-03
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0d Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:23:9d:3b FC Portname: 50:0a:09:84:80:23:9d:3b Connection: No link Switch Port: Unknown SFP Vendor Name: PROLINE SFP Vendor P/N: SFP-10G-SR-CDW SFP Vendor Rev.: 2.0 SFP Serial No.: PROSR00558 SFP Connector: LC SFP Capabilities: 10 Gbit/Sec 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0e Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:23:9d:3b FC Portname: 50:0a:09:81:80:23:9d:3b Connection: No link Switch Port: Unknown 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0f Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:23:9d:3b FC Portname: 50:0a:09:82:80:23:9d:3b Connection: No link Switch Port: Unknown 0 - Intel Broadwell SATA Controller Additional Info: u0a (0x92410000) SV9MST6D120GLM41NP FW1122 114473MB 512B/sect (SPG201004CG) 0 - Intel Broadwell USB2 Enhanced Host Controller
Node: g1950srva8001-04
Sub- Device/ Slot slot Information
- - System NetApp Release 9.10.1P12: Wed Apr 12 20:30:59 EDT 2023 System ID: 0538156517 (g1950srva8001-04); partner ID: 0538156347 (g1950srva8001-03) System Serial Number: 632020000306 (g1950srva8001-04) System Rev: B0 System Storage Configuration: Single-Path HA System ACP Connectivity: Inband Active All-Flash Optimized: true Capacity Optimized: false All SAN Array: false Backplane Part Number: DS22412 Backplane Rev:
Backplane Serial Number: 042002055461
Node: g1950srva8001-04
Sub- Device/ Slot slot Information 0 - Controller Module
1.5 GHz (System Board XXII B0)
Model Name: AFF-A220 Part Number: 111-04333 Revision: B0 Serial Number: 042013018558 BIOS version: 11.20 Loader version: 6.0.17 Processors: 12 Processor ID: 0x50664 Microcode Version: 0xf00001a Processor type: Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz Memory Size: 32768 MB Memory Attributes: Hoisting Rank Interleaving CHannel Interleaving Mezzanine Card:
Part: 111-04160 Version: A1 Serial: 042005009820 NVMEM Size: 4094 MB of Main Memory Used Controller: B PCIE Switch 1: id 1 546 1.04 TPM FW Version: 5.63.3353.0 0 - Service Processor Service Processor Status: Online Firmware Version: 11.9 Mgmt MAC Address: d0:39:ea:1c:b3:8d Ethernet Link: up, full duplex, auto-neg complete Using DHCP: no IPv4 configuration:
IP Address: 10.0.81.149 Netmask: 255.255.254.0 Gateway: 10.0.80.1 IPv6 configuration: Disabled [Service Processor cached network information determined at Wed May 24 15:57:12 UTC 2023] 0 - Internal 10/100/1000 Ethernet Switch Wrench: auto-1000t-fd-up Device Type: 88E6176 0 - Gigabit Ethernet I210 e0M MAC Address: d0:39:ea:1c:b3:8b (auto-1000t-fd-up) Device Type: 0x1533 (BSD99) Firmware Version: 3.25-7.5 0x80000674 0 - 10 Gigabit Ethernet Controller IX5-SFP+ e0a MAC Address: d0:39:ea:1c:b3:7d (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340072 e0b MAC Address: d0:39:ea:1c:b3:7e (auto-10g_twinax-fd-up) SFP Vendor: Molex Inc.
SFP Part Number: 747529720 SFP Serial Number: 011340066 Device Type: X550EM(0x15AC) (BSD99) Firmware Version: 1.13-7.1
Node: g1950srva8001-04
Sub- Device/ Slot slot Information
0 - 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2) e0e MAC Address: d0:39:ea:1c:b3:81 (auto-unknown-fd-down) e0f MAC Address: d0:39:ea:1c:b3:82 (auto-unknown-fd-down) e0c MAC Address: d2:39:ea:1c:b3:8b (auto-10g_sr-fd-up) e0d MAC Address: d2:39:ea:1c:b3:8b (auto-10g_sr-fd-up) Device Type: EP8324N Firmware Version: 5.4.66.0
0 - PLX PCIe DMA
0 - PLX PCIe DMA PLX DMA Engine: 2 PLX: 0x87d0 State: Active
0 - PLX NTB
Device Name: Interconnect HBA: Generic OFED Provider Port Name: ic0a Default GID: fe80:0000:0000:0000:0000:0000:0000:0105 Base LID: 0x105 Active MTU: 8192 Max HW Data Rate: PCIe Gen 3 x 8 HW Data Rate: PCIe Gen 3 x 8 SW Data Rate: PCIe Gen 3 x 8 Logical Link: Up Port State: Enabled 0 - PMC SAS/SATA Controller 8070 SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <OFFLINE (hard)>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e2ae6:b0 Temperature: Not Available Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled Mini-SAS HD Vendor: not available Mini-SAS HD Part Number: not available Mini-SAS HD Type: not available Mini-SAS HD Serial Number: not available SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>) Firmware rev: 03.08.09.00 Base WWN: 5:00a098:00e2ae6:b4 Temperature: Not Available Phy State: [4] Enabled, 12.0 Gb/s [5] Enabled, 12.0 Gb/s [6] Enabled, 12.0 Gb/s [7] Enabled, 12.0 Gb/s
Node: g1950srva8001-04
Sub- Device/ Slot slot Information 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0c Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:73:9d:e5 FC Portname: 50:0a:09:83:80:73:9d:e5 Connection: No link Switch Port: Unknown SFP Vendor Name: Intel Corp SFP Vendor P/N: AFBR-703SDZ-IN2 SFP Vendor Rev.: G2.3 SFP Serial No.: AD1205A0C82 SFP Connector: LC SFP Capabilities: 1, 10 Gbit/Sec 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0d Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:73:9d:e5 FC Portname: 50:0a:09:84:80:73:9d:e5 Connection: No link Switch Port: Unknown SFP Vendor Name: Intel Corp SFP Vendor P/N: AFBR-703SDZ-IN2 SFP Vendor Rev.: G2.3 SFP Serial No.: AD1205A0B2U SFP Connector: LC SFP Capabilities: 1, 10 Gbit/Sec 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0e Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:73:9d:e5 FC Portname: 50:0a:09:81:80:73:9d:e5 Connection: No link Switch Port: Unknown 0 - QLogic EP 8324 PCI-Express FCoE FC controller Description: Fibre Channel Target Host Adapter 0f Details: QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED> Firmware Rev.: 8.9.0 Flash Rev.: 7.0.3 Host Port Addr: 000000 FC Nodename: 50:0a:09:80:80:73:9d:e5 FC Portname: 50:0a:09:82:80:73:9d:e5 Connection: No link Switch Port: Unknown
Node: g1950srva8001-04
Sub- Device/ Slot slot Information 0 - Intel Broadwell SATA Controller Additional Info: u0a (0x92410000) SV9MST6D120GLM41NP FW1122 114473MB 512B/sect (SPG201004XP) 0 - Intel Broadwell USB2 Enhanced Host Controller
100 entries were displayed.
g1950srva8001::> storage aggregate show-status
Owner Node: g1950srva8001-01 Aggregate: aggr0_g1950srva8001_01 (online, raid_tec) (block checksums) Plex: /aggr0_g1950srva8001_01/plex0 (online, normal, active, pool0) RAID Group /aggr0_g1950srva8001_01/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 2.0.1 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.2 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.3 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.4 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.5 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.6 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.7 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.8 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.9 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.10 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.2 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.11 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.3 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.4 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.0.0 0 FSAS 7200 53.88GB 7.15TB (normal)
Owner Node: g1950srva8001-02 Aggregate: aggr0_g1950srva8001_02 (online, raid_tec) (block checksums) Plex: /aggr0_g1950srva8001_02/plex0 (online, normal, active, pool0) RAID Group /aggr0_g1950srva8001_02/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 2.1.1 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.2 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.3 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.4 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.5 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.6 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.7 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.8 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.9 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.10 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.8 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.11 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.9 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.2.10 0 FSAS 7200 53.88GB 7.15TB (normal) shared 2.1.0 0 FSAS 7200 53.88GB 7.15TB (normal)
Owner Node: g1950srva8001-03 Aggregate: aggr0_g1950srva8001_03 (online, raid_dp) (block checksums) Plex: /aggr0_g1950srva8001_03/plex0 (online, normal, active, pool0) RAID Group /aggr0_g1950srva8001_03/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 1.0.0 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.1 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.2 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.3 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.4 0 SSD - 62.35GB 3.49TB (normal)
Owner Node: g1950srva8001-04 Aggregate: aggr0_g1950srva8001_04 (online, raid_dp) (block checksums) Plex: /aggr0_g1950srva8001_04/plex0 (online, normal, active, pool0) RAID Group /aggr0_g1950srva8001_04/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 1.0.18 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.19 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.20 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.21 0 SSD - 62.35GB 3.49TB (normal) shared 1.0.22 0 SSD - 62.35GB 3.49TB (normal)
Owner Node: g1950srva8001-01 Aggregate: aggr_g1950srva8001_01 (online, raid_tec) (block checksums) Plex: /aggr_g1950srva8001_01/plex0 (online, normal, active, pool0) RAID Group /aggr_g1950srva8001_01/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 2.0.3 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.4 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.5 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.6 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.7 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.8 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.9 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.10 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.2 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.1 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.0 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.0 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.1 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.2 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.3 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.4 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.0.11 0 FSAS 7200 7.09TB 7.15TB (normal)
Owner Node: g1950srva8001-02 Aggregate: aggr_g1950srva8001_02 (online, raid_tec) (block checksums) Plex: /aggr_g1950srva8001_02/plex0 (online, normal, active, pool0) RAID Group /aggr_g1950srva8001_02/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 2.1.3 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.4 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.5 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.6 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.7 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.8 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.9 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.10 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.2 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.1 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.0 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.6 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.7 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.8 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.9 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.2.10 0 FSAS 7200 7.09TB 7.15TB (normal) shared 2.1.11 0 FSAS 7200 7.09TB 7.15TB (normal)
Owner Node: g1950srva8001-03 Aggregate: aggr_g1950srva8001_03 (online, raid_dp) (block checksums) Plex: /aggr_g1950srva8001_03/plex0 (online, normal, active, pool0) RAID Group /aggr_g1950srva8001_03/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 1.0.0 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.1 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.2 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.3 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.4 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.18 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.19 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.20 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.21 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.22 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.5 0 SSD - 1.72TB 3.49TB (normal)
Owner Node: g1950srva8001-04 Aggregate: aggr_g1950srva8001_04 (online, raid_dp) (block checksums) Plex: /aggr_g1950srva8001_04/plex0 (online, normal, active, pool0) RAID Group /aggr_g1950srva8001_04/plex0/rg0 (normal, block checksums) Usable Physical Position Disk Pool Type RPM Size Size Status shared 1.0.18 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.19 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.20 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.21 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.22 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.0 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.1 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.2 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.3 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.4 0 SSD - 1.72TB 3.49TB (normal) shared 1.0.5 0 SSD - 1.72TB 3.49TB (normal) 96 entries were displayed.
Other files
| File | Type | Posted |
|---|---|---|
| System configurations 2.updated 5.30.txt | TXT text file | |
| System configurations.updated 5.30.pdf | ||
| g1950srva8000.txt | TXT text file | |