PR_81-4057-18_Salient_Characteristics_v2_(002).pdf

PDF 647 KB Posted

Attached to
Matric Signal Measurement Equipment
Solicitation number
N00173-19-R-SP06
Issued by

About this file

Salient Characteristics

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PR# 81-4057-18

PR 81-4057-18 Salient Characteristics_v2 (002)

Specifications

PSC: 6625 – Electrical and Electronics Properties Measuring and Testing Instruments

NAICS: 334515 - Computer Terminal and Other Computer Peripheral Equipment

Manufacturing

1. Signal Generator:

Unit Height 2U in Rack (3.5 inches)

Unit Width (≤ 19 inches)

Unit Depth Rack (≤ 24 inches)

Unit Weight ≤ 25 lbs.

Power Requirements 120 VAC, 60 Hz, ≤ 280W

Frequency Range 9 kHz to 40 GHz

Frequency Resolution 0.001 Hz

Writable Memory Removable

Step Attenuation 115 dB

Power Output [20-40 GHz] +15 dBm

Power Output Resolution 0.01 dB

Power Output Accuracy [±10 dBm] ± 0.8 dB

Power Output Accuracy [≥75 dBm] ± 2.0 dB

SWR [20-40 GHz; w/ 5 dB Atten] ≤1.6:1.0; ≤1.4:1.0

SSB Phase Noise See Figures 1 and 2

Figure 1: Absolute SSB Phase Noise (CW) Table

Figure 2: SSB Phase Noise Chart

ANSI Z540-1-1994 Calibration @ Delivery

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Warranty Assurance Plan Return to Factory for 5 Years

Broadband Noise [40 GHz] -135 dBc/Hz

Harmonics, CW-mode See Figure 3

Figure 3: Harmonics, CW-mode left at +10 (left) and +20 (right) dBm Chart

Non-harmonics [20 to 40 GHz] -62 dBc max (-68 dBc typ)

Sub-harmonics [> 20 to 40 GHz] -53 dBc max (-63 dBc typ)

Communication Interface Ethernet

Communication Protocol TCP/IP

Control Protocol Language SCPI

Frequency Reference External Reference Option

External Frequency Mixer Support "Ext. Frequency Mixer Control, via Int.

Frequency Offset"

2. Power Meter

Unit Height 2U in Rack (3.5 inches)

Unit Width 1/2 Rack (≤ 9.5 inches)

Unit Depth Rack (≤ 24 inches)

Rackmount kit 2 units (side-by-side)

Unit Weight ≤ 10 lbs.

Power Requirements 120 VAC, 60 Hz, ≤ 50W

Enable Dual Power Sensor Dual-channel, VGA output, 2x USB

ANSI Z540-1-1994 Calibration @ Delivery

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Warranty Assurance Plan Return to Factory for 5 Years

Communication Interface Ethernet

Communication Protocol TCP/IP

Control Protocol Language SCPI

50 MHz Power Sensor Ref. Source Power Ref. (@ 0 dBm) w/i 0.4%

3. Power Sensor

Frequency Range 50 MHz to 50 GHz

Power Range -70 to -20 dBm

ANSI Z540-1-1994 Calibration @ Delivery

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Warranty Assurance Plan Return to Factory for 5 Years

Typical Uncertainty See Figure 4

Frequency

(GHz)

Root Sum of

Squares

Uncertainty

1 1.3

2 1.3

4 1.4

6 1.4

8 1.4

10 1.5

12 1.5

14 1.6

16 1.7

18 1.7

22 1.9

26.5 2.2

28 2.3

30 2.4

33 2.6

34.5 2.6

37 2.7

40 3.0

42 3.2

44 2.5

46 3.8

48 3.8

50 5.0

Figure 4: Typical Uncertainty

Maximum SWR & Power Linearity See Figure 5

Frequency Range Maximum

SWR

Power

Linearity

Maximum Power

0.05 to 0.1 GHz 1.19

-30 to -20 dBm (±2%)

100 mW avg

100 mW pk

10 W.µs per pulse

0.1 to 2 GHz 1.15

2 to 12.4 GHz 1.20

12.4 to 18 GHz 1.29

18 to 34 GHz 1.37

34 to 40 GHz 1.61

40 to 50 GHz 1.89

Figure 5: Maximum SWR & Power Linearity

Cal Factor Uncertainty See Figure 6

Frequency Calibration Factor

Uncertainty (at 25°C ± 3°C)

30 to 500 MHz 1.33

500 MHz to 1.2 GHz 1.35

1.2 to 6 GHz 1.41

6 to 14 GHz 1.61

14 to 18 GHz 1.73

18 to 26.5 GHz 2.26

26.5 to 33 GHz 2.58

33 to 34 GHz 2.80

34 to 35 GHz 2.80

35 to 40 GHz 2.80

40 to 45 GHz 3.66

45 to 50 GHz 4.23

Figure 6: Cal Factor Uncertainty

4. Step Attenuator

Programmable Step Attenuator 11 dB in 1 dB Steps

Frequency Range 50 MHz to 40 GHz

Attenuation Accuracy [30 to 40 GHz] ±1.2 dB @ 9 dB Setting

Insertion Loss [30 to 40 GHz] ≤ 2.28 dB @ 0 dB Setting

SWR (max) [30 to 40 GHz] ≤ 2.0:1.0

Maximum Input Power +30 dBm (average)

Typical Attenuation Uncertainty See Figure 7

Attenuation

(db)

Typical Uncertainty dc to 20 GHz 20 to 26.5 GHz 26.5 to 40 GHz

0 ± 0.12 ± 0.12 ± 0.15

10 ± 0.16 ± 0.24 ± 0.30

20 ± 0.16 ± 0.25 ± 0.30

30 ± 0.17 ± 0.30 ± 0.30

40 ± 0.32 ± 0.47 ± 0.30

50 ± 0.36 ± 0.54 ± 0.30

60 ± 0.36 ± 0.54 ± 0.30

70 ± 0.52 ± 0.72 ± 0.35

80 ± 0.50 ± 0.52 ± 0.60

90 ± 0.66 ± 0.91 ± 1.05

Figure 7: Typical Attenuation Uncertainty

Input & Output Connectors 2.92mm, Female

Attenuator Supply Voltage Level 24 V DC

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Step Attenuator Life 5 million cycles per section

Repeatability ±0.03 dB, max 5M cycles per section

5. Step Attenuator

Step Attenuator 70 dB in 10 dB Steps

Frequency Range 0 to 40 GHz

Attenuation Accuracy [30 to 40 GHz] ±1.2 dB @ 50 dB Setting

Insertion Loss [30 to 40 GHz] ≤ 1.71 dB @ 0 dB Setting

SWR (max) [30 to 40 GHz] ≤ 1.9:1.0

Maximum Input Power +30 dBm (average)

Typical Attenuation Uncertainty See Figure 7

Input & Output Connectors 2.92mm, Female

Attenuator Supply Voltage Level 24 V DC

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Step Attenuator Life 5 million cycles per section

Repeatability ±0.03 dB, max 5M cycles per section

6. Multifunction Module

Compatible with 34972A

Control up to 8-bit PIN Diode Switch

Control SPDT up to SP8T Switch

Control DPDT Switch

7. Data Acquisition Unit

Unit Width 1/2 Rack (≤ 9.5 inches)

Unit Depth Rack (≤ 24 inches)

Unit Weight ≤ 10 lbs.

Power Requirements 120 VAC, 60 Hz, ≤ 15 W

Communication Interface Ethernet

Communication Protocol TCP/IP

Control Protocol Language SCPI

ANSI Z540-1-1994 Calibration @ Delivery

Warranty Assurance Plan Return to Factory for 5 Years

Control Multifunction Modules Support up to 3x 34970A Modules

Drop-in Replacement For 34972A

8. Attenuation Switch Driver

Unit Width 1/2 Rack (≤ 9.5 inches)

Unit Depth Rack (≤ 24 inches)

Unit Weight ≤ 10 lbs.

Power Requirements 20 VAC, 60 Hz, ≤ 100 W

Communication Interface Ethernet

Communication Protocol TCP/IP

Control Protocol Language SCPI

Warranty Assurance Plan Return to Factory for 5 Years

Control Step Attenuators Support 84904L & 84907L

Voltage & Current 24 ± 8%, 1.7A (max continuous)

Drop-in Replacement 11713B

9. Power Sensor

Frequency Range 50 MHz to 40 GHz

Power Range [average power] -45 to +20 dBm

Communication Interface USB

Control Protocol Language SCPI

ANSI Z540-1-1994 Calibration @ Delivery

ANSI Z540-1-1994 Calibration Return to Factory for 5 Years

Warranty Assurance Plan Return to Factory for 5 Years

Power Sensor Cable 16.4 ft. (5 m)

Cal. Uncertainty [26.5 to 40.0 GHz] ≤ ±0.3 dB or ±5.8%

SWR (max) [26.5 to 40.0 GHz] ≤ 1.5:1.0

File details come from the government source that posted it.