SUBSYSTEM TO NRL’S TACTICAL COMMUNICATIONS SYSTEM
SALIENT CHARACTERISTICS
The Naval Research Laboratory (NRL) has a requirement for the following pieces of equipment to be integrated into a Tactical Communications System (TCS). The specifications below shall be met in order to be implemented seamlessly with a pre-existing Tecore man-pack LTE eNodeB system. For responses to the RFI, please provide scientific backup that the product offered is fully interoperable with NRL’s man-pack.
Advanced Laboratory Real-Time Signal Analyzer
· Frequency Range 16 KHz to 26.5 GHz
· Acquisition Bandwidth 800 MHz
· Streaming data to RAID memory & 40 GigE
· More than 120 minutes record time in RAID memory
· Support for IEEE 802.11 a/b/g/j/n/p measurements/analysis
· Support for LTE Downlink measurements/analysis
· Support for flexible OFDM analysis
· Support for Pulse Analysis to work with MDO-4104C MDO
· Signal Survey & Classification support
· Modulation analysis to work with MDO-4104C MDO
· Support for advanced triggers (Frequency Mask, Density)
· Must be able to directly measure RF channel energy for all possible waveforms.
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Arbitrary Waveform Generator (AWG)
· Create arbitrary waveforms based on user specifications
· Analog Bandwidth: 13.5 GHz
· 2 channels with 10-bit vertical resolution up to 25 Gs/s
· Create digitally modulated signals with multiple carrier groups
· Support for sequencing
· Support for 8 Gs/s sample rate on both channels
· Must USB device port which also can support GPIB (conforming to IEEE 488.1, and compatible with IEEE-488.2 and SCPI-1999.0)
· Ethernet (IEEE 802.3) 10/100/1000baseT interface via RJ-45 connector
· eSATA interface
· Able to import from AWG, AWGX, WFMX, RFD, SXD, WFM, PAT, IQT, TIQ, ISF, TXT, SEQ, SEQX, and MATLAB file formats
· Able to export Text (TXT) and Extended Waveform (WFMX) file formats
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment
Field Real-Time Signal Analyzer with Extreme Portability
· Small lightweight hand-held size and light weight, so easy to carry in the field.
· Real-time signal analyzer supporting USB interface
· Frequency Range: 9 KHz to 6.2 GHz
· Instantaneous Bandwidth: 40 MHz
· Minimum signal duration as short as 27 μsec will be captured
· Supports MATLAB Instrument Driver
· Includes software application supports capture/analysis of 27 modulation types including 16/32/64/256 QAM, QPSK, O-QPSK, GMSK, FSK, APSK
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Advanced Field Real-Time Signal Analyzer
· Frequency Range: 9 KHz to 18 GHz
· Instantaneous Bandwidth: 40 MHz
· Sweep Rates up to 70 GHz/sec
· Must include Windows-based signal analysis application supporting capture/analysis of 27 modulation types including 16/32/64/256 QAM, QPSK, O-QPSK, GMSK, FSK, APSK
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Mixed Domain Oscilloscope
· Supports 4 channels at 1 GHz each
· Record length of 20 minutes on each channel
· Supports up to 5 GS/second
· Includes Arbitrary Function Generator capability with:
· 13 Pre-defined waveforms
· 50 MHz waveform generation
· 128 k arbitrary generator record length
· 250 MS/s arbitrary generator sample rate
· Includes Windows-based signal analysis software with live link to MDO unit
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Vector Network Analyzer
· Frequency Range: 100 KHz to 6 GHz
· Dynamic Range greater than 122 dB
· Output Power from -50 dBm to +7 dBm
· RMS trace noise less than 0.008 dB
· Full 2-port 2-path S-parameter measurement (S11, S21, S12, S22)
· Supports Microsoft Windows & existing NI LabView software application
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Portable Graphical Sampling Multimeter
· Small size and weight to ensure this handheld device easy to use in the field
· Maximum Resolution: 7.5 digits
· Supports digitizing rate up to 1MS/s
· Stores up to 11 M readings
· Supports GPIB/IEEE-488.1, USB 2.0, and 10/100baseT Ethernet interfaces.
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Real-Time Signal Analyzer
· Frequency Range: 1 Hz to 26.5 GHz
· Acquisition Bandwidth: 165 MHz with HDR
· Acquisition Memory: 4 GBytes
· Minimum Event Duration: 2.7 us
· Supports digital I&Q output and Zero-Span analog output
· Supports Microsoft Windows version 10 Enterprise Edition
· Supports removable solid-state disk (SDD) drive
· Includes EMI pre-compliance/troubleshooting software
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment Signal Capture & Analysis Software
· Works with & supports above USB Real-Time Signal Analyzers
· Enables acquisition bandwidths up to 1000 MHz
· Enables measurement and recording with 2 USB RTSAs simultaneously
· Controls instruments via software
· Pulse analysis calculates start/stop time, average/peak power, pulse duration, Pulse Repetition Interval (PRI) and start/stop frequencies on up to 2M pulses
· Supports exporting Pulse analysis results into PDW file format.
· FFT overlap and speed controls optimize between highest probability of intercept vs. analysis time
· Supports exporting areas of interest to .XDAT, .SIQ or .TIQ file formats
· Compatible with Microsoft Windows computers.
· Must support and must be fully interoperable with NRL's existing Tecore LTE equipment