Questions & Answers to Solicitation Number: Number N00173-16-R-JF01
Q. As per the SOW it states this will be a drop in replacement for the existing shipboard and airborne electronic ware fare systems, what is the current part number/ NSN of that existing amplifier?
A. The current MPM is made by L-3 Communications Electron Devices. The part number is M1225-03.
Q. Is there a possibility to provide more information of the existing amplifier this is replacing ? Picture, schematics, spec sheet, test specs and etc on the existing amplifier.
A. See L-3 data sheet for the M1225 MPM for the closest representation of the current MPM being used. The M1225-03 is a M1225 that has been modified to meet the requirements listed in the SOW.
Q. Second question, the documentation line item 0002 is to be consisted of only the performance data of the MPM and certification of performance? Are you also looking for the contractors test plan, test procedures, or any repair level documentation for the future?
A. No. we are not looking for a test plan, test procedures or repair level documentation. We only need the performance data and certification of performance for each MPM to show that all the specifications listed in the SOW have been met by each MPM.