continuation_sheet.docx

DOCX document 14 KB Posted

Attached to
Ultra Narrow Linewidth Tunable CW Ti: Sapphine Laser with Pump Laser and Precision Wavemeter
Solicitation number
N00173-15-Q-0396
Issued by

About this file

Continuation Sheet (revised addition dated 7/22/15)

View the file

Other files

File Type Posted
SF30_AMENDMENT_OF_SOLIC_MODIFICATION_OF_CONTR.pdf PDF
SF-18.pdf PDF
Solicitation_Clauses_Mar_30_2015_update.doc DOC document
SF-18.pdf PDF
Solicitation_Clauses_Mar_30_2015_update.doc DOC document
continuation_sheet.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STANDARD FORM 36 JULY 1966

GENERAL SERVICES ADMINISTRATION

FED. PROC. REG. (41 CFR) 1-16.101

CONTINUATION SHEET
REF. NO. OF DOC. BEING CONT’D

N00173-15-Q-0396

PAGE OF

2 16

NAME OF OFFEROR CONTRACTOR

ALL QUOTERS

ITEM NO.
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT

REVISED ADDITION 7/22/15

Ultra Narrow Linewidth Tunable CW Ti: Sapphine Laser with Pump Laser and Precision Wavemeter.

System Requirements:

-The power output over the entire range must be at least 200m W -Full coverage of the 700-1000nm range without any change of optics, mechanical adjustment, or intervention. There should be no gaps in the tuning range.

-Computer Control of the system must be possible using Labview -The laser linewidth must be less than 5 MHz, absolute and relative to reference cavity.

-Amplitude noise should be less than 0.9% root mean square (RMS) above pump noise, added in quadrature.

-Pump noise is <0.03% RMS -Scan Speed shuold be > 100 GHz/sec -Should not require dust-free air environment. Should have a sealed head.

-Should be compact (<30 cm x 30 cm, 15 cm high) -The system must have a wavemeter that communicates with the laser control electronics to provide precise, repeatable, and hands-free scanning and locking to any user-selected wavelength within the tuning range.

-The system must provide automatic stitching of laser resonator scans to give continuous narrow linewidth scans -The included wavemeter must have an absolute accuracy of 60 MHz or better and resolution of 10 MHz or better.

Items must be brand name or equal.

If available, please include a published price list or a cost breakdown and return the RFQ package to Kerry Callahan at the following email: kerry.callahan@nrl.navy.mil