continuation_sheet.docx
DOCX document 14 KB Posted
- Attached to
- Ultra Narrow Linewidth Tunable CW Ti: Sapphine Laser with Pump Laser and Precision Wavemeter
- Solicitation number
- N00173-15-Q-0396
About this file
Continuation Sheet (revised addition dated 7/22/15)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30_AMENDMENT_OF_SOLIC_MODIFICATION_OF_CONTR.pdf | ||
| SF-18.pdf | ||
| Solicitation_Clauses_Mar_30_2015_update.doc | DOC document | |
| SF-18.pdf | ||
| Solicitation_Clauses_Mar_30_2015_update.doc | DOC document | |
| continuation_sheet.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STANDARD FORM 36 JULY 1966
GENERAL SERVICES ADMINISTRATION
FED. PROC. REG. (41 CFR) 1-16.101
| CONTINUATION SHEET |
| REF. NO. OF DOC. BEING CONT’D |
N00173-15-Q-0396
PAGE OF
2 16
NAME OF OFFEROR CONTRACTOR
ALL QUOTERS
| ITEM NO. |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
REVISED ADDITION 7/22/15
Ultra Narrow Linewidth Tunable CW Ti: Sapphine Laser with Pump Laser and Precision Wavemeter.
System Requirements:
-The power output over the entire range must be at least 200m W -Full coverage of the 700-1000nm range without any change of optics, mechanical adjustment, or intervention. There should be no gaps in the tuning range.
-Computer Control of the system must be possible using Labview -The laser linewidth must be less than 5 MHz, absolute and relative to reference cavity.
-Amplitude noise should be less than 0.9% root mean square (RMS) above pump noise, added in quadrature.
-Pump noise is <0.03% RMS -Scan Speed shuold be > 100 GHz/sec -Should not require dust-free air environment. Should have a sealed head.
-Should be compact (<30 cm x 30 cm, 15 cm high) -The system must have a wavemeter that communicates with the laser control electronics to provide precise, repeatable, and hands-free scanning and locking to any user-selected wavelength within the tuning range.
-The system must provide automatic stitching of laser resonator scans to give continuous narrow linewidth scans -The included wavemeter must have an absolute accuracy of 60 MHz or better and resolution of 10 MHz or better.
Items must be brand name or equal.
If available, please include a published price list or a cost breakdown and return the RFQ package to Kerry Callahan at the following email: kerry.callahan@nrl.navy.mil
Any questions concerning this Request for Quotation (RFQ) must be emailed to SolOnA@nrl.navy.mil at least five (5) days before the closing date shown in block 10 on page 1 of the RFQ.
EA
File details come from the government source that posted it. Updated .