This document is a Solicitation Amendment for Contract N0016724Q0281, issued by the Naval Surface Warfare Center Carderock Division (NSWCCD). The amendment provides answers to industry questions and updates the delivery address for the Diesel Fueled Packaged Mobile Generator Set being procured under this contract.
The key details are:
- The solicitation is amended to incorporate questions from industry and update the delivery address to NAVSTA Norfolk Bldg. V47, 1052 Pocahontas St. Norfolk, VA, 23511.
- Acceptable specifications include a 150-gallon or greater double-walled diesel tank with 110% spill containment, low fuel and fuel leak alarms (not UL142 listed), and a minimum one-day training session.
- The order requires a 28-hour runtime fuel tank, and noise level of 66 dBA at 23 feet, which differ from the vendor's standard specifications provided in the questions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N0016724Q0281 CSS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1301176595
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
1. Solicitation Amendment is issued to incorporate the Questions from the Industry and to add the Generator delivery address.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 20-Aug-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N0016724Q0281
X 9B. DATED (SEE ITEM 11)
13-Aug-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
20-Aug-2024
CODE
NAVAL SURFACE WARFARE CENTER CARDEROCK
ARNEL A. NGO
ARNEL.A.NGO.CIV@US.NAVY.MIL
904 CORPORATE LANE
CHESAPEAKE VA 23320
N00167 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N0016724Q0281
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
DELIVERIES AND PERFORMANCE
The following Delivery Schedule item for CLIN 0001 has been changed from:
DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
30-SEP-2024 1 N/A
FOB: Destination
To:
DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
30-SEP-2024 1 NAVAL SEA COMBAT SYSTEM
ENGINEERING STAT
RECEIVING OFFICER
1052 POCAHONTAS ST, BLDG. V-47
NORFOLK VA 23511-2134
757-462-4517 FOB: Destination
N64281
The following have been added by full text:
Questions from the Industry
1. Would a “150 Gallon or greater double-walled diesel tank with 110% spill containment, low fuel and fuel leak alarms” be acceptable? *Not UL142 listed – (UL142 is not applicable for mobile applications)
Answer: Yes that description would be acceptable.
2. Please confirm ship to address.
Answer: NAVSTA Norfolk
Bldg. V47, 1052 Pocahontas St.
Norfolk, VA, 23511
3. UL142 double wall is necessary for this mobile application?
Answer: UL142 not required, double wall is required.
4. For at-site start up testing and demo/training session, how many hours of training are required?
N0016724Q0281
Answer: Minimum one-day training, further length acceptable as determined by vendor.
5. Does the training site require any special permits or have access restrictions that would require the trainer to account for expenses?
Answer: Training must be able to pass background check for access to US Naval Installation. Trainers must be US citizens.
6. Will our manufacturer's standard double walled integral fuel tank be acceptable in lieu of a UL142 certified tank which is a certification for fixed, permanently installed sub-base fuel tanks?
Answer: Yes, UL142 not required, double wall is required
7. Will a 19.7hr run time fuel tank be acceptable in lieu of a 28hr tank?
Answer: No.
8. Will a 72dBA at 23ft be acceptable in lieu of 66dBA at 23ft?
Answer: No
(End of Summary of Changes)