N0016719Q02150001.docx

DOCX document 34 KB Posted

Attached to
Magnetic Shield Assembly Federal contract opportunity
Solicitation number
N0016719Q0215
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document contains a solicitation for a magnetic shield assembly. The Naval Surface Warfare Center, Carderock Division intends to negotiate a firm fixed-price contract for the supply of a magnetic shield assembly using FAR Part 12 and 13.5 procedures. The North American Industry Classification code is 333249 and size standard is 500 employees. A request for quote will be available on August 29, 2019 at www.fbo.gov. Vendors must be registered in SAM and self-certify that they are not suspended, debarred or otherwise ineligible. Questions may be directed to Morgan Olszak.

Amendment to extend solicitation closing and post Q&As

View the file

Other files for this federal contract opportunity

Other files attached to Magnetic Shield Assembly, newest first.
File Type Posted
N0016719Q021500002.docx DOCX document
Attachment_1_-_Shield_Drawing.pdf PDF
COMBINED_SYNOPSIS_SOLICITATION_N0016719Q0215.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N0016719Q0215

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 11-Sep-2019 12:00 PM to 18-Sep-2019 12:00 PM.

The following have been added by full text:

QUESTIONS AND ANSWERS

QUESTIONS AND ANSWERS

1. Could we get a copy of the 3D Model in a .step file format?

0. At this time, this is not available. This is a conceptual model where specific dimensions and features in the drawing have been left to the manufacturers.

1. Are cradle mounts to be included? We see they are on the print as visual reference only.

1. Yes, please see Enclosure 1 – Minimum Requirements for further information.

1. Looks like material thickness is .118” or .003m. Could we use .062” thick material or .00157m?

2. Please see Enclosure 1 – Minimum Requirements for further information.

(End of Summary of Changes) image1.wmf