The Contractor shall provide the information in the Table of Thermal Destruction System Characteristics:

Table of Thermal Destruction System Characteristics (Page 1 of 2)

Capacity (Million btu per day)

Capacity (btu per hour)

Capacity (pounds per hour)

Length Width Height Weight Power

Overall Dimensions (length x width x height (inches))

Automatic Feed System

Type of Feeder

Size of Opening (length x width (inches))

Maximum dimension of waste (length x width x height (inches))

Type of airlock between the operator and the chamber

Method of Controlling the Feed Rate

Shredder (if used)

Conveyors (if used)

Other Feed Equipment (list if used)

Ash Removal System

Type of Mechanism

Ash Container Dimensions (inches)

Method of Controlling Airborne Dust

Other Equipment (list if used)

Auxiliary Equipment (if used)

Hydraulic Power Unit

Central Air Fan

Compressed Air Conditioning Equipment (dryer, filter, etc.) (list)

Exhaust Gas System

Quench Type (wet/dry)

Wet Quench Fresh Water Flow Rate (gallons per minute)

Wet Quench Salt Water Flow Rate (gallons per minute)

Wet Quench Drain Flow Rate (gallons per minute)

Draft System (Induced Draft Fan/Draft Inducer/Other)

Draft Control Method (Modulating (Damper/Modulating Fan/other), Fixed (Manual))

Exhaust Gas Flow Rate at Standard Conditions (cubic feet per minute)

Exhaust Gas Duct Diameter (inches)

Other Exhaust Gas Equipment (list each)

Table of Thermal Destruction System Characteristics (Page 2 of 2)

Chamber Volume (cubic inches)

Chamber Dimensions (length x width x height or length x diameter (inches))

Chamber Auxiliary Burner Capacity (btu per hour)

Chamber Burner Controls (Modulating/Multi-Position/On-Off)

Chamber Combustion Air Flow (cubic feet per minute)

Chamber Air Controls (Modulating (Automatic)/Fixed (on-off))

Chamber Refractory Service Temperature (Degrees F)

Chamber Refractory Thichness (inches)

Chamber Insulation Service Temperature (Degrees F)

Chamber Insulation Thichness (inches)

Chamber Insulation Type

Chamber Structural Shell Thichness (inches)

Chamber Air Gap (if used) (inches)

Chamber Outer Shroud Thickness (if used) (inches)

Chamber Retention Time (seconds)

Primary Chamber Hearth Loading (lb/hour/square foot)

Chamber Heat Loading (btu/hour/cubic foot)

Control System

Type of Temperature Sensors (list)

Type of Flow Meters (list)

Type of Pressure Sensors (list)

Control Voltages (list)

Variable Frequency Drives (yes/no) (list brand/model number)

Programmable Logic Controller (yes/no) (list brand/model number)

Electronic Display (yes/no) (list brand/model number)

Utility Usage

Fuel (diesel or kerosene) to Preheat the Chamber from a Cold Start (gallons)

Fuel (diesel or kerosene) during normal operation (gallons per day)

Electricity (kW at 440V/3ph/60Hz)

Fresh Water (gallons per day)

Salt Water (gallons per day)

Compressed Air (total) (standard cubic feet per day)

Compressed Air Maximum Usage Rate (standard cubic feet per minute)

Combustion Air Rate (total for all parts) during normal operation (cfm)

Consumable Parts (expected life less than 24 months of daily use) (list)

Vibration specification the system has been designed for/tested against

Shock specifcication the sytem has been designed for/tested against

Electromagnetic Compatability specification the system has been designed for/tested against

Heat given off by the equipment into a 32 degree Farenheit room (btu/hour)

Surface Temperature (degrees Farenheit)

Noise (dbA)

Thermal Destruction Chambers Primary Secondary Tertiary

Duct to

Quench