N00024-16-R-6327
Section B - Supplies or Services and Prices
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0001
JCREW I1B1 DISMOUNTED SYSTEMS
FFP
Each
Dismounted systems shall be built IAW TDP Drawing No. 8664660. (SEE NOTE G) FOB: Origin (Shipping Point)
PURCHASE REQUEST NUMBER: N0002416NR99618
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0002
JCREW I1B1 MOUNTED / FIXED SYSTEMS
Each
Mounted/Fixed systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE G and H)
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0003
JCREW I1B1 MOUNTED AUXILIARY KITS
Each
Mounted auxiliary kits shall be built IAW TDP Drawing No. 8664665. (SEE NOTE G and H)
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0004
JCREW I1B1 FIXED AUXILIARY KITS
Each
Fixed auxiliary kits systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE G and H)
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0005
| 49,572 |
| Hours |
| OPTION |
| ENGINEERING SUPPORT SERVICES |
(SEE NOTES B and F) FOB: Origin (Shipping Point)
CPFF
ESTIMATED COST
FIXED FEE
TOTAL EST COST + FEE
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0006
| 1 |
| Lot |
| OPTION |
| OTHER DIRECT COSTS (ODC) |
COST
Other Direct Costs (ODC) in support of CLIN 0005 Engineering Support Services. Incidental materials and travel that are used or consumed directly in connection with performance of CLIN 0005 Engineering Support Services. (SEE NOTES B and I)
ESTIMATED COST
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0007
ORDERING LINE ITEM - PIO
Provisioned items Orders (PIO) and Subassembly Parts Orders. If issued, orders under this line item shall be IAW the requirements of Section C clause HQ C-1-0003 Provisioned Items Orders. Firm Fixed Pricing will be set forth on each order.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0008
DATA
Not Separately Priced (NSP)
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0009
FIRST ARTICLE UNITS AND ASSOCIATED TESTS
FFP
| 1 |
| Lot |
CLIN 0009 includes delivery of two (2) units of each variant and associated auxiliary kit priced separately under CLINs 0101, 0102, 0103, and 0104. Delivery of these two (2) units of each variant and pricing under CLIN 0009 shall include the Production Readiness Review, Pysical Configuration Audit, and First Article Qualification Testing as detailed in Section C, Statement of Work.
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0101
JCREW I1B1 DISMOUNTED SYSTEMS
Each
| OPTION |
| Dismounted systems shall be built IAW TDP Drawing No. 8664660. (SEE NOTE A, B and G) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0102
JCREW I1B1 MOUNTED / FIXED SYSTEMS
Each
| OPTION |
| Mounted/Fixed systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0103
JCREW I1B1 MOUNTED AUXILIARY KITS
Each
| OPTION |
| Mounted auxiliary kits shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0104
JCREW I1B1 FIXED AUXILIARY KITS
Each
| OPTION |
| Fixed auxiliary kits systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0105
| 66,861 |
| Hours |
| OPTION |
| ENGINEERING SUPPORT SERVICES |
(SEE NOTE B and F) FOB: Origin (Shipping Point)
ESTIMATED COST
FIXED FEE
TOTAL EST COST + FEE
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0106
| 1 |
| Lot |
| OPTION |
| OTHER DIRECT COSTS (ODC) |
COST
Other Direct Costs (ODC) in support of CLIN 0105 Engineering Support Services. Incidental materials and travel that are used or consumed directly in connection with performance of CLIN 0105 Engineering Support Services. (SEE NOTE B and I)
ESTIMATED COST
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0201
JCREW I1B1 DISMOUNTED SYSTEMS
Each
| OPTION |
| Dismounted systems shall be built IAW TDP Drawing No. 8664660. (SEE NOTE A, B and G) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0202
JCREW I1B1 MOUNTED / FIXED SYSTEMS
Each
| OPTION |
| Mounted/Fixed systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0203
JCREW I1B1 MOUNTED AUXILIARY KITS
Each
| OPTION |
| Mounted auxiliary kits shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0204
JCREW I1B1 FIXED AUXILIARY KITS
Each
| OPTION |
| Fixed auxiliary kits systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0205
| 47,072 |
| Hours |
| OPTION |
| ENGINEERING SUPPORT SERVICES |
(SEE NOTE B and F) FOB: Origin (Shipping Point)
ESTIMATED COST
FIXED FEE
TOTAL EST COST + FEE
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0206
Lot
| OPTION |
| OTHER DIRECT COSTS (ODC) |
COST
Other Direct Costs (ODC) in support of CLIN 0205 Engineering Support Services. Incidental materials and travel that are used or consumed directly in connection with performance of CLIN 0205 Engineering Support Services. (SEE NOTE B and I)
ESTIMATED COST
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0301
JCREW I1B1 DISMOUNTED SYSTEMS
Each
| OPTION |
| Dismounted systems shall be built IAW TDP Drawing No. 8664660. (SEE NOTE A, B and G) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0302
JCREW I1B1 MOUNTED / FIXED SYSTEMS
Each
| OPTION |
| Mounted/Fixed systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0303
JCREW I1B1 MOUNTED AUXILIARY KITS
Each
| OPTION |
| Mounted auxiliary kits shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0304
JCREW I1B1 FIXED AUXILIARY KITS
Each
| OPTION |
| Fixed auxiliary kits systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0305
| 29,835 |
| Hours |
| OPTION |
| ENGINEERING SUPPORT SERVICES |
(SEE NOTE B and F) FOB: Origin (Shipping Point)
ESTIMATED COST
FIXED FEE
TOTAL EST COST + FEE
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0306
| 1 |
| Lot |
| OPTION |
| OTHER DIRECT COSTS (ODC) |
COST
Other Direct Costs (ODC) in support of CLIN 0305 Engineering Support Services. Incidental materials and travel that are used or consumed directly in connection with performance of CLIN 0305 Engineering Support Services. (SEE NOTES B and I)
ESTIMATED COST
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0401
JCREW I1B1 DISMOUNTED SYSTEMS
Each
| OPTION |
| Dismounted systems shall be built IAW TDP Drawing No. 8664660.(SEE NOTE A, B and G) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0402
JCREW I1B1 MOUNTED / FIXED SYSTEMS
Each
| OPTION |
| Mounted/Fixed systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0403
JCREW I1B1 MOUNTED AUXILIARY KITS
Each
| OPTION |
| Mounted auxiliary kits shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0404
JCREW I1B1 FIXED AUXILIARY KITS
Each
| OPTION |
| Fixed auxiliary kits systems shall be built IAW TDP Drawing No. 8664665. (SEE NOTE A, B, G, and H) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0405
| 29,835 |
| Hours |
| OPTION |
| ENGINEERING SUPPORT SERVICES |
(SEE NOTE B and F) FOB: Origin (Shipping Point)
ESTIMATED COST
FIXED FEE
TOTAL EST COST + FEE
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 0406
| 1 |
| Lot |
| OPTION |
| OTHER DIRECT COSTS (ODC) |
COST
Other Direct Costs (ODC) in support of CLIN 0405 Engineering Support Services. Incidental materials and travel that are used or consumed directly in connection with performance of CLIN 0405 Engineering Support Services.(SEE NOTE B and I)
ESTIMATED COST
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1011
JCREW I1B1 O-Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 1. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1012
JCREW I1B1 O-Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 2. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1013
JCREW I1B1 O-Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 3. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1014
JCREW I1B1 O-Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 4. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1015
JCREW I1B1 O-Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 5. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1016
JCREW I1B1 O-Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 6. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1021
JCREW I1B1 Depot Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 1. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1022
JCREW I1B1 Depot Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 2. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1023
JCREW I1B1 Depot Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 3. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1024
JCREW I1B1 Depot Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 4. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1025
JCREW I1B1 Depot Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 5. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1026
JCREW I1B1 Depot Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 6. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1031
JCREW I1B1 Support Equipment Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 1 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1032
JCREW I1B1 Support Equipment Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 2 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1033
JCREW I1B1 Support Equipment Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 3 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1034
JCREW I1B1 Support Equipment Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 4 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1035
JCREW I1B1 Support Equipment Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 5 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 1036
JCREW I1B1 Support Equipment Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 6 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2011
JCREW I1B1 O-Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 1. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2012
JCREW I1B1 O-Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 2. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2013
JCREW I1B1 O-Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 3. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2014
JCREW I1B1 O-Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 4. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2015
JCREW I1B1 O-Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 5. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2016
JCREW I1B1 O-Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 6. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2021
JCREW I1B1 Depot Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 1. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2022
JCREW I1B1 Depot Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 2. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2023
JCREW I1B1 Depot Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 3. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2024
JCREW I1B1 Depot Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 4. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2025
JCREW I1B1 Depot Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 5. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2026
JCREW I1B1 Depot Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 6. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2031
JCREW I1B1 Support Equipment Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 1 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2032
JCREW I1B1 Support Equipment Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 2 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2033
JCREW I1B1 Support Equipment Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 3 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2034
JCREW I1B1 Support Equipment Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 4 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2035
JCREW I1B1 Support Equipment Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 5 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 2036
JCREW I1B1 Support Equipment Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 6 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3011
JCREW I1B1 O-Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 1. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3012
JCREW I1B1 O-Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 2. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3013
JCREW I1B1 O-Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 3. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3014
JCREW I1B1 O-Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 4. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3015
JCREW I1B1 O-Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 5. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3016
JCREW I1B1 O-Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 6. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3021
JCREW I1B1 Depot Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 1. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3022
JCREW I1B1 Depot Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 2. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3023
JCREW I1B1 Depot Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 3. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3024
JCREW I1B1 Depot Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 4. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3025
JCREW I1B1 Depot Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 5. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3026
JCREW I1B1 Depot Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 6. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3031
JCREW I1B1 Support Equipment Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 1 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3032
JCREW I1B1 Support Equipment Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 2 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3033
JCREW I1B1 Support Equipment Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 3 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3034
JCREW I1B1 Support Equipment Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 4 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3035
JCREW I1B1 Support Equipment Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 5. (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 3036
JCREW I1B1 Support Equipment Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 6. (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4011
JCREW I1B1 O-Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 1. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4012
JCREW I1B1 O-Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 2. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4013
JCREW I1B1 O-Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 3. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4014
JCREW I1B1 O-Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 4. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4015
JCREW I1B1 O-Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 5. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4016
JCREW I1B1 O-Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 6. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4021
JCREW I1B1 Depot Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 1. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4022
JCREW I1B1 Depot Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 2. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4023
JCREW I1B1 Depot Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 3. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4024
JCREW I1B1 Depot Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 4. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4025
JCREW I1B1 Depot Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 5. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4026
JCREW I1B1 Depot Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Repair Parts Kit 6. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4031
JCREW I1B1 Support Equipment Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 1 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4032
JCREW I1B1 Support Equipment Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 2 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4033
JCREW I1B1 Support Equipment Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 3 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4034
JCREW I1B1 Support Equipment Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 4 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4035
JCREW I1B1 Support Equipment Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 5 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 4036
JCREW I1B1 Support Equipment Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 6 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5011
JCREW I1B1 O-Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 1. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5012
JCREW I1B1 O-Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 2. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5013
JCREW I1B1 O-Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 3. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5014
JCREW I1B1 O-Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 4. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5015
JCREW I1B1 O-Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 5. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5016
JCREW I1B1 O-Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Organizational Level Spares and Consumables Kit 6. (SEE NOTE B and D) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5021
JCREW I1B1 Depot Level Parts Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 1. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5022
JCREW I1B1 Depot Level Parts Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 2. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5023
JCREW I1B1 Depot Level Parts Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 3. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5024
JCREW I1B1 Depot Level Parts Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 4. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5025
JCREW I1B1 Depot Level Parts Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 5. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5026
JCREW I1B1 Depot Level Parts Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| Initial Depot Level Spares and Consumables Kit 6. (SEE NOTE B and E) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5031
JCREW I1B1 Support Equipment Kit 1
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 1 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5032
JCREW I1B1 Support Equipment Kit 2
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 2 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5033
JCREW I1B1 Support Equipment Kit 3
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 3 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5034
JCREW I1B1 Support Equipment Kit 4
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 4 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5035
JCREW I1B1 Support Equipment Kit 5
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 5 (SEE NOTE B and C) |
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
CLIN Number 5036
JCREW I1B1 Support Equipment Kit 6
FFP
| 1 |
| Lot |
| OPTION |
| JCREW I1B1 Support Equipment Kit 6 (SEE NOTE B and C) |
NET AMT
AMENDMENT 0003
| # |
| Date Submitted: |
| Page number and paragraph header from source: |
| Question: |
| Answer: |
| 52 |
| 9/19/2016 |
| SF33 |
| We would like to request an extension of the solicitation due date so that we are able to obtain and review the changes in the SOW and have time to review the Solicitation GFI against Attachment 5 and the soliciation requirements. |
| The Government has extended the proposal submission deadline to 07 November 2016 |
| 53 |
| 9/20/2016 |
| Page 1, Paragraph 9 |
| The due date for this proposal is 17 October 2016. Questions are to be submitted NLT 30 September 2016 (30 days after RFP posting). Answers to the questions are necessary for the contractor to develop a compliant proposal in response to the RFP. Would Government extend proposal submission deadline by 90 days? |
| The Government has extended the proposal submission deadline to 07 November 2016 |
| 54 |
| 9/21/2016 |
| p. 176, Section L, Paragraph 2.2 |
| Volume II is limited to 130 pages. Within this paragraph there are two places that list several items that do not count against the page count. Section L, paragraph 2.5.1.1.1.g requires a Quality Assurance Plan be submitted with the proposal that includes objective evidence to all of the ISO 9000 standards. Section M, paragraph 1.1.1.1.1.g also validates the Government will be evaluating the contractor’s submitted Quality Assurance Plan. Since a full Quality Assurance Plan can easily exceed 100 pages (especially in order to meet all ISO and program-unique requirements), can the Quality Assurance Plan be included as one of the documents excluded from the page count requirements? |
| Concur, QA Plan(s) and supporting QA documentation submitted as compliance with RFP requirements will not count towards the page number total of the proposal. RFP Amendment 0003 will reflect this change. |
| 55 |
| 9/22/2016 |
| SF 33, Box 9, Due Date for Proposals |
| Will the USG extend the due date for receipt of bidder's proposal until November 17, 2016? |
| The Government has extended the proposal submission deadline to 07 November 2016 |
| 56 |
| 9/22/2016 |
| Page 80, Section C, Paragraph 3.4.1.3 |
| The second paragraph of 3.4.1.3 (Category C Depot Repair Items) of the SOW states: “… the system/assembly shall be shipped back to the Government CONUS/OCONUS point of debarkation and placed back into the spares pool.” In addition, Section I of the solicitation includes DFARS clause 252.225-7048 (Export-Controlled Items). Please confirm whether or not the scope of work to be awarded under this contract will require delivery of production systems to an OCONUS location, return of repaired items to an OCONUS location, or actual performance of services at an OCONUS location. If so, please confirm whether Section 3.9 (International Traffic In Arms Regulations) applies to these scenarios and the Contractor will be solely responsible for obtaining any State Department approvals, licenses, Technical Assistance Agreements required by the ITAR. Lastly, please provide a list of the potential OCONUS locations in conjunction with the type of services and/or deliveries to be performed there. This information is required for cost estimation purposes as well as export requirements review. |
| There is no requirement for OCONUS Delivery. |
| 57 |
| 9/22/2016 |
| Page 167, Section L, Paragraph 1.0 |
| In Section L, 1.0 General Support, the RFP references three support contractors, Alcyone Consulting Inc., AECOM, and Science Applications International Corp. Can you provide the POC information for each so we can contact them and put non-disclosure agreements in place? |
| Potential Offerors that require Non-Disclosure Agreements (NDAs) with support contractors listed in the RFP should email the blank company-specific form to brendan.kittredge@navy.mil and copy krysten.ellis@navy.mil. The Government will then facilitate the NDA process through to applicable POCs at each support contractor. |
| 58 |
| 9/22/2016 |
| Attachment 9, Identified WBS |
| With respect to the WBS provided in Attachment 9, can the government clarify if the funding for the JCREW Increment 1 Block 1 Full Rate Production contract will allocate all of the CLINs under the government’s “Procurement Contracts” cost element, level 3? Are there any activities that would be funded under any other level 3 line item? |
| RFP Amendment 0002 will include a revised Attachment 9. |
| 59 |
| 9/22/2016 |
| Page 170, Section L, Paragraph 2.1 |
| Please confirm that under RFP, Section L, Page 170, paragraph 2.1, entitled “Restriction on Disclosure and Use of Data”; the reference to FAR 52.215-12 should be FAR 52.215-1. |
| The Government has corrected the reference under paragraph 2.1, entitled “Restriction on Disclosure and Use of Data” to FAR 52.215-1 in RFP Amendment 0003. |
| 60 |
| 9/27/2016 |
| Page 53, Section B, Note F |
| Section B, Note F specifies that the “Fixed Fee shall be proposed by the Offeror at 6% of Estimated Cost.” Additionally, Paragraph 3.6 (Engineering Support Services) of the SOW includes potential tasking, such as insertion of new technologies (TIE), configuration changes, verification of system to operational specifications, and sustainment engineering that would require more senior-level engineering expertise that qualifies for a higher fixed fee percentage under the USG’s weighted guidelines. For this reason, we respectfully request that the directed fixed fee be revised to reflect a higher percentage that is more commensurate with the types of tasking to be performed under this CLIN. |
| RFP Amendment 0003 has been updated to include a MAXIMUM fee of 8%. Offerors may propose less than 8% fee and are reminded that fixed fee will be evaluted in the Total Evaluated Cost/Price. |
| 61 |
| 9/27/2016 |
| Section I, Page 136 |
| DFARS 209.571-8 (b) states: “Use the clause at 252.209-7009, Organizational Conflict of Interest—Major Defense Acquisition Program, in solicitations and contracts for systems engineering and technical assistance for major defense acquisition programs or pre-major defense acquisition programs.” Normally this clause is incorporated into SETA contracts where the SETA Contractor is providing Systems Engineering and Technical Assistance only, and is not also providing the “build to print” production system deliverables. Given that this contract’s scope of work does not include “systems engineering and technical assistance” from a SETA perspective, we request that DFARS clause 252.209-7009 (Organizational Conflict of Interest—Major Defense Acquisition Program) be removed from Section I of this solicitation. |
| Clause 252.209-7009 has been removed in RFP Amendment 0003. |
| 62 |
| 9/27/2016 |
| Section C, Page 136 |
| FAR 46.805 (Contract clauses) paragraph (3) states: “In contracts requiring delivery of both high-value items and other end items, insert both clauses prescribed in (a)(1) and (a)(2) of this section, Alternate I of the clause at 52.246-24, and identify clearly in the contract schedule the line items designated as high-value items.” For this reason, we request that FAR clause 52.246-23 (Limitation of Liability) be added to the solicitation. |
| FAR 52.246.23 has been added to the Solicitation in RFP amendment 0003. |
| 63 |
| 9/27/2016 |
| Section I, Page 141 |
| Section I, FAR 52.209-3 First Article Approval—Contractor Testing (SEP 1989) – ALTERNATE I (JAN 1997): Given that it is essential for the Contractor to purchase production material to some extent before first article approval in order to meet the contract delivery schedule, FAR 9.308-1(b)(3) advises that the contracting officer shall use a clause substantially the same as the clause at 52.209-3, First Article Approval—Contractor Testing, with its Alternate II. For this reason, the Contractor requests the solicitation be revised to include FAR 52.209-3 First Article Approval—Contractor Testing (SEP 1989) – ALTERNATE II (SEP 1989). |
| RFP Amednment 0003 includes FAR 52.209-3 First Article Approval—Contractor Testing (SEP 1989) – ALTERNATE II (SEP 1989). |
| 64 |
| 9/27/2016 |
| Section B, Note A, Page 52 |
| In regards to Stepladder Pricing, Section B, Note A, of the RFP states: “First exercise of option CLIN 9999: quantity of 150 at a unit price of $150 each for an extended price of $22,500 (=150*$150) funded on CLIN 9999. Second exercise of option CLIN 9999: quantity of 200. The second exercised quantity of 200 plus the first exercised quantity of 150 equates to 350 in total for CLIN 9999. The unit price for 350 units is $100, thereby making the extended total price $35,000 (=350*$100). Therefore, the unit price for CLIN 9999 would be unilaterally adjusted in accordance with Note A and Note G to reflect a quantity of 350 at a unit price of $100 with an extended price of $35,000.” Please confirm that the each time a CLIN is exercised, the quantity of systems ordered for each task order will only be used once to determine unit pricing during a 60 day ordering period. For instance, using the scenario provided above, if the first exercise of option CLIN 9999 is awarded July 1st, and the 2nd exercise is awarded August 30th, which is within 60 days of the first exercise, resulting in a unit price adjustment based on Stepladder pricing, if a 3rd exercise of CLIN 9999 is awarded September 15th (past 60 days from the first exercise but within 60 days of the 2nd), that the quantity of systems ordered in the 3rd exercise will be considered the first order/exercise for the next 60 day period, and that it will not be added to the quantities of exercise 1 and 2 to adjust unit pricing a second time. |
| The 60 day window applies from the date of the first option exercise. This has been clarified in RFP Amendment 0003. |
| 65 |
| 9/06/2016 |
| Overall |
| Please advise if you would permit an offshore division to perform portions of this requirement to help save overall labor costs. |
| A Potential Offeror is expected to comply with all RFP terms and conditions including security requirements listed in the DD254, the Buy American Act, and procedures for handling ITAR controlled material. |
| 66 |
| 9/16/2016 |
| Paragraph 3.6, Engineering Support Services |
| The SOW defines all Engineering Support Services (ESS) as government directed TI efforts. This does include sustaining engineering *Removed for Sanitization*. If the Offeror is not clear on what the government defines as sustaining engineering or we expect confusion between LRIPs and FRP then we may wish to clarify. As written all cost associated with unit build/test and delivery are in the FFP of the other CLINs even if engineering is called in to resolve or help. Defined items such as FRACAS,R&M, or DMS reporting, RFV etc would not be costs attributed to sustaining engineering. |
| Efforts funded under Engineering Services Support CLINs will be clearly defined in the respective Technical Instructions. ESS related to LRIP units are not intended under this contract. |
| 67 |
| 10/01/2016 |
| Section B, Note A, Page 62 |
| Section B Note A of the RFP states that the Government may unilaterally exercise a given CLIN more than once, prior to the latest option exercise date identified in clause 52.217-7, and up to the total quantity. However, CLINs 0001-0009 are not identified as Option CLINs in Section B or listed under FAR 52.217-7, Option for Increased Quantity – Separately Priced Items. Does this mean the USG intends to exercise the Base Year CLINs only once during the period of performance of the Base Year, and will all Base Year CLINs be exercised simultaneously? |
| CLINs 0001-0009 are not option CLINs and will be exercised accordingly at contract award. Note A does not apply to CLINs 0001-0009. |
| 68 |
| 10/01/2016 |
| Section F, Page 107, Delivery Note 1 |
| Section F, Page 107, Delivery Note 1 states that the delivery information will be “filled in” upon each option exercise, including period of performance, quantities, and ship to information. Please confirm that this Note 1 applies to the Delivery Information beginning at the bottom of Page 107, and is applicable to all CLINs (Base & Options). |
| Delivery Note 1 applies to options CLINs only. Delivery Information for Base Year CLINs 0001-0004 and 0009 has been filled in in RFP Amendment 0003. |
| 69 |
| 10/01/2016 |
| Section I, Page 142 |
| Section I, Page 142, 52.217-7 OPTION FOR INCREASED QUANTITY--SEPARATELY PRICED LINE ITEM (MAR 1989), the RFP provides the latest exercise option date applicable to the Option CLINs. However, the contract does not identify the earliest exercise Option Date. Is it the intention of the USG to exercise Option Year CLINs in conjunction with the GFY? Is there potential that exercise of the Option Years could overlap? |
| While it is the intent of the Government to award each Option to coincide with the Government Fiscal Year, Options may be exercised as solicited. |
| 70 |
| 10/01/2016 |
| Section I, Page 142 |
| Section I, Page 142. 52.217-9 OPTION TO EXTEND THE TERM OF THE CONTRACT; This clause states in paragraph (c) that the total duration of this contract, including the exercise of any option(s) under this clause, shall not exceed five (5) years, with the exception of the LOE ESS CLINs when the total delineated hours have not been expended. However, this clause seems to be in conflict with the Option for Increased Quantity, 52,217-7, which identifies the latest option exercise date for the Option Year 4 CLINs to be 60 months (five years). If an Option Year 4 CLIN is exercised on the latest exercise option date with delivery required within 22 months of exercise, the total performance of the contract would be (7) years. Does “duration” in the context of this clause cover the ordering period only or actual performance? |
| CLINs 5011-5036, which are for O-level Parts, Depot Level Parts, and Support Equipment, are intended to have a Latest Option Exercise Date of 60 months ADC. |
| 71 |
| 10/03/2016 |
| Section I |
| Section I of the solicitation incorporates DFARS Clause 252.246-7001, ALT II, Warranty of Data (Mar 2014) by reference. This ALT II clause imposes additional potential liabilities upon the Contractor that will need to be accounted for in the original bid price and in every future engineering change proposal. For this reason, the Contractor requests that the Government consider removing ALT II from the solicitation and simply leave in DFARS clause 252.246-7001, Warranty of Data (Mar 2014). |
| DFARS Clause 252.246-7001 and DFARS Clause 252.246-7001 Alt II have been removed in RFP Amendment 0003. |
AMENDMENT 0002
| # |
| Date Submitted: |
| Page number and paragraph header from source: |
| Question: |
| Answer: |
| 26 |
| 9/8/2016 |
| RFP Page 2-16; Section B, Supplies or Services and Prices (CLINs 002-004, 0102-0104, 0202-0204, 0302-0304, 0402-0404) |
| The “OPTION” note that accompanies each of the referenced CLINs states “xxx shall be built IAW TDP Drawing No. 8664665 (SEE NOTE A, B, G and H)” |
Referencing only drawing 8664665 is not sufficient to adequately describe the material listing that comprises each of the three CLIN types (JCREW I1B1 MOUNTED/FIXED SYSTEMS, JCREW I1B1 MOUNTED AUXILIARY KITS, and JCREW I1B1 FIXED AUXILIARY KITS).
Please provide a unique Ordering or Parts List number (for example 8664665-1, 8664665-2, 86647667-2, or otherwise) that explicitly defines the contents of each of these three CLINs. A complaint proposal cannot be provided without a better definition of what is being requested.
Note H states "The RT box and Auxiliary kits are detailed in Section J, Attachment 6." The specifics to this note are defined in two main drawings: 1) The Drawing PL8664665 lists multiple parts of which all are considered Auxiliary Kit item except 8664667-1 (Mounted) and 8664667-2 (Fixed Site). 2) The Drawing PL8664667 lists multiple parts of which All parts with the "Notes" column filled with "NOTE 3" are Auxiliary Kit items and the remaining parts without "NOTE 3" are considered the RT Box.
| 27 |
| 9/9/2016 |
| RFP p. 176 paragraph (d) "Disposition of Technical Data Package" |
| Last sentence of this paragraph states that, " Offerors shall not download any files from the CD/DVD onto any local area network (LAN) or integrated digital environment (IDE)." Does this statement apply only after contract award or to the entire proposal process including the time before the award? |
| This statement applies to the entire proposal process including time before award. |
| 28 |
| 9/16/2016 |
| RFP Page 53, Stepladder Pricing |
| The table for Stepladder Pricing does not include an estimated start date for the Base Year. Can the bidder assume that the estimated start date for the Base Year is 6/01/2017, and that it will run for twelve months with each Option Year starting at the end of the previous year? If not, can you provide estimated start dates for Base/Option Years? |
| An estimated date of award of 01 July 2017 has been added to the Solicitation in Section L in Amendment 0002. |
| 29 |
| 9/16/2016 |
| RFP Section C Paragraph 3.6, Page 82 |
| This SOW section (3.6 Engineering Services) lists vehicle installation and integration. In order to assign appropriate labor rates please confirm the OCONUS support will not be required? |
| OCONUS support will not be required for vehicle installation and integration |
| 30 |
| 9/19/2016 |
| RFP Page 2-16; Section B, Supplies or Services and Prices (CLINs 0002, 0003, 0004, 0102, 0103, 0104, 0202, 0203, 0204, 0302, 0303, 0304, 0402, 0403, and 0404) |
| The note that accompanies each of the referenced CLINs states “xxx shall be built IAW TDP Drawing No. 8664665 (SEE NOTE A, B, G and H)” Referencing only drawing 8664665 number does not adequately describe the ordering item (i.e. Parts List) for the JCREW I1B1 MOUNTED/FIXED SYSTEMS and AUXILIARY KITS. Understanding that the 8664665-1 is the MOUNTED system and 8664665-2 is the FIXED system, each uses a different configuration of the Receive/Transmit box (8664667-1 or 8664667-2) with the difference being the inclusion of the parts that make up the shock isolation solution. In order to improve the government’s desire for equivalent competitive proposals, suggest that the government provide a Parts List number for the common Receive/Transmit box (CLINs 0002, 0102, 0202, 0302) and prove a Parts List for each of the MOUNTED AUXILIARY KIT (CLINs 0003, 0103, 0203, 0303) and FIXED AUXILIARY KIT (CLINs 0004, 0104, 0204, 0403). |
| Note H states "The RT box and Auxiliary kits are detailed in Section J, Attachment 6." The specifics to this note are defined in two main drawings: 1) The Drawing PL8664665 lists multiple parts of which all are considered Auxiliary Kit item except 8664667-1 (Mounted) and 8664667-2 (Fixed Site). 2) The Drawing PL8664667 lists multiple parts of which All parts with the "Notes" column filled with "NOTE 3" are Auxiliary Kit items and the remaining parts without "NOTE 3" are considered the RT Box. |
| 31 |
| 9/19/2016 |
| RFP Section C 3.7.1, Attachment 5 GFE |
| Will test fixtures/test software and test stations be furnished to support FE/AT ? |
| No test fixtures, test stations, or test software will be furnished as part of a contractual requirement. The Government may provide data related to testing as GFI via the Bidder's Library as reference material only post-award. |
| 32 |
| 9/19/2016 |
| RFP Section C 3.1.6.2, Attachment 5 GFE |
| Will the Navy provide FE/AT test cycle times? |
| Test Cycle times are defined in Attachment 5, Item #16, FE/AT Plan, Figure 2. |
| 33 |
| 9/20/2016 |
| Page 181, Paragraph 2.4.1 b) 4., |
Page 191, Paragraph 2.7.1.1.1
| Section 2.4.1 Solicitation Set, b), 4. Completed Attachment 2 requires the Cost and Price Summary Workbook in Volume I. However, Paragraph 2.7.1.1.1 Cost and Price Summary Format Workbook (attachment 2) states that Attachment 2 is required in Section IV Cost Price Proposal. Should Attachment 2 be included in both volumes? |
| Attachment 2 shall be included in Volume IV. Attachment 2 will be removed from Section L 2.4.1 in RFP Amendment 0002. |
| 34 |
| 9/20/2016 |
| Page 191, Paragraph 2.7.1.1 |
| Will the Labor Categories provided in the table for the Labor Mix be incorporated into the contract for billing purposes? Or are the categories for evaluation purposes only and each contractor will bill its applicable approved direct labor rates with approved indirects if awarded? |
| The Labor Categories provided in the solicitation are for evaluation purposes only. Actual contractor specific labor categories may differ in title and shall be clearly mapped to the solicitation labor categories as stated in RFP Section L 2.7.1.1 as follows: "The Offeror shall provide a mapping of any contractor specific labor categories it, or one of its subcontractors, proposes in the “ESS Cost Summary” Tab of Attachment 2 to the Government Labor Category Definitions above in the Cost Narrative described below. " |
| 35 |
| 9/20/2016 |
| Page 176, Paragraph 2.2, |
Page 178, Paragraph 2.2.3
| On RFP page 176, the table states that 1 original and 4 copies (5 total) of electronic files for each volume are required. However, on page 178, the RFP states that 1 original and 2 copies (3 total) of electronic files for each volume are required. Please clarify the correct number of electronic CD-ROM copies required. |
| RFP Section L 2.2.3 has been amended to correspond with RFP Section L 2.2 in RFP Amendment 0002. One (1) Original and four (4) copies of electronic files shall be submitted. |
| 36 |
| 9/20/2016 |
| Section B, Note G |
| The RFP requests stepladder pricing for a minimum quantity of 1 to a maximum quantity of 1000. How many systems of each variant (# of units)are anticipated in the base year and option years? |
| As solicited the Government could potentially order anywhere from 1 to 1,000 units of each variant in each contract year. |
| 37 |
| 9/20/2016 |
| Page 74, Paragraph 3.1 |
| The RFP states this is a build-to-print effort and the contractor shall build systems in accordance with the TDP as provided as GFI. Has the TDP baseline system passed all qualification tests? Will the test artifacts be provided? Will the test plans and procedures as well as test limits be provided? |
| TDP baseline systems will be qualified by Contract Award. All test limits are documented in all test plans, currently available in Bidder's Library as documented in Attachment 5, GFI list, Items 3, 15, 16. |
| 38 |
| 9/20/2016 |
| Page 74, Paragraph 3.1 |
| If the LRIP systems have passed FAQT and the TDP meets all requirements, why is it necessary for the contractor to execute FAQT (assuming the contractor passes PCA)? Does FAQT include all environmental testing, reliability demonstration, EMI/EMC, shock & vibration, etc.? |
| Production start mandates a new PCA and FAQT. FAQT shall be executed in accordance with FAQT Plan and Procedures (A005) as specified in the RFP. |
| 39 |
| 9/20/2016 |
| Page 80, Paragraph 3.1.6.2.1 |
| Does an ESS profile already exist for the system? If so, will it be provided? What is the time duration estimated for each cycle? |
| No ESS Profile currently exists for the system. This Profile shall be required to be developed and delivered for USG approval prior to test execution. Development of ESS Profile shall be IAW MILHDBK-2164A. Delivery of ESS Plan shall be under CDRL A015 (Environment Stress Screening Plan and Procedures) |
| 40 |
| 9/20/2016 |
| Page 80-81, Paragraph 3.1.6.2.2 |
| The duration of PRAT (16 hours) is long for each manufactured system, and appears to include thermal and electrical stresses. Because the system has already been through ESS for 5 thermal cycles, is there an opportunity for the contractor to update test plans and procedures to optimize for manufacturing while ensuring the system meets all requirements? |
| Conversion to a sampling plan shall be IAW PRAT Plan, provided as GFI, Section J, Attachment 5 |
| 41 |
| 9/20/2016 |
| Page 83, Paragraph 3.2.2.4, 3.2.2.5 |
| If the contractor builds the system exactly to print and in accordance with the TDP and the resulting unit does not pass qualification tests, the RFP states the contractor is responsible for failure analysis and corrective actions. Does this include design changes to make the system meet the requirements? Where is this funded? Does the contractor have access to the OEM of JCREW I1B1 for design discussions? |
| Failures shall be handled as outlined in RFP Section C paragraph 3.2.2. All design discussions will be handled by the Government. |
| 42 |
| 9/20/2016 |
| Page 90, Paragraph 3.9 |
| Is it anticipated that the system will be exported? Is FMS a consideration? Does an ITAR approval/exemption exist for the system? |
| At this time FMS is not a consideration. |
| 43 |
| 9/20/2016 |
| Page 79, Paragraph 3.1.6.1 |
| Is special-purpose test equipment necessary for conducting FAQT or PRAT? Does automated test equipment (ATE) exist? If so, will the ATE or ATE documentation be provided to the contractor? |
| The Government will not provide ATE or ATE documentation. ATE is not required per the solicitation requirements, however the Offeror must demonstrate a viable test approach and identify manufacturing risks in CDRL A001. |
| 44 |
| 9/20/2016 |
| Page 74-75, Paragraph 3.1 |
| All systems are subjected to FE/AT, ESS, and PRAT. Is this a valid assumption? |
| All systems will go through FE/AT and ESS. PRAT will be executed on systems according to RFP Section C paragraph 3.1.6.2.2. |
| 45 |
| 9/20/2016 |
| Page 89, Paragraph 3.8 |
| The RFP states that "Effective Program Security requires the Contractor to address a variety of security disciplines - Program Protection Planning, Security Systems Engineering (SSE), Information Assurance (IA)/Cybersecurity, Information Security, Key Management, and Operations Security". Does the system currently meet all of the program security requirements? Should the contractor anticipate making changes to the system due to SSE and/or Cybersecurity? |
| The system currently meets all program security requirements. All changes will be intiated through ECP's/TI's as required. |
| 46 |
| 9/20/2016 |
| Page 74, Paragraph 3.1 |
This is the start of the file's text. The full file is on GovTribe.