RF Shielded Tent System Requirements The proposed RF Shielded Tent for analysis of file systems is requested for purchase for the Foreign Materiel Exploitation Laboratory Analysis Branch (TAC-342), Office of Naval Intelligence, Washington, DC.

Below are requirements the system must meet:

· The system must provide at least 85dB of shielding from 500 MHz to 16GHz. This shielded must be met at all points of the tent (walls, ceiling, floor, door, ventilation).

· The frame of the tent (not including the vestibule) must be no bigger than 11’x11’8.5’ (length x width x height)

· The shielded area (not including the vestibule) must be at least 9’x9’x7.5’ (length x width x height)

· The tent must contain a shielded vestibule at least 65” x 36” (width x depth)

· The thresholds must be removable.

· The door must be 54” x 78” (width x height)

· The tent must contain hard cases for transport.

· The tent must contain interior lighting.

· The tent must have a 100dB power filter (100 kHz to 40 GHz)

· The tent must have an internal power strip. At least 5 outlets.

· The tent must have an interface with two N-type connectors.

· The tent must be capable of cooling with air conditioner and air ventilation.

· The air conditioner must have waterproof hard case for transportation.