This document contains a technical specification sheet for the MedRx AWRC Audiometry & Wireless REM/LSM system. The specification sheet provides details on the key features and capabilities of the MedRx AWRC system, which combines a dual-channel audiometer with wireless real ear measurement and live speech mapping functionality in a compact device. The system is capable of air, bone, and speech audiometry testing, as well as real ear measurements, up to a frequency of 20,000 Hz with an optional high frequency add-on. Additional features and capabilities of the MedRx AWRC system described in the specification sheet include wireless Bluetooth probe microphones, various prescription methods, counseling tools, and compatibility with common audiology practice management systems.

The related federal contract opportunity is a pre-solicitation notice for solicitation number 36C25623Q1681 to purchase the MedRx AWRC system from MedRx, Inc. for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The specification sheet provides relevant technical details that could inform requirements for the federal procurement of this audiology device.

View the file

Other files

File Type Posted
36C25623Q1681.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.medrx-diagnostics.com

MedRx AWRC Audiometry & Wireless

REM/LSM

888-392-1234 To Schedule An Online Demo

Wireless REM/LSM and Clinical Audiometer Combined in One Compact System Audiometry Testing up to 20 kHz with High-Frequency Option

AUD

REM

LSM

Dual Channel Audiometry Perform air conduction, bone conduction, masking and speech testing using the mouse and/or keyboard with ease.

Real Ear Measurements IEC/ANSI standard REM functions are provided for: REUR, REUG, REIG, REAG, REAR, REOR, REOG and RECD.

Live Speech Mapping Live Speech Mapping (LSM) a quick and successful approach to hearing instrument fitting.New Feature Probe Tube Depth Guide

AWRC Standard Accessories

• Wireless Probe Mics with Bow and Charging Base

• Transducers: DD65v2 or DD45 or IP30

• Bone Conductor

• Monitor Headphone

• Speaker

• Patient Response Switch

• Talkback Microphone

• Auditec Sound File License

• QuickSIN™ License

• USB Cable

• External Power Supply

• Probe Tube Pack

• Software & Manuals

• Carrying Case

AWRC Optional Accessories

• High Frequency Option with DD450 Headphones

• RECD Coupler

High Frequency Option Allows Testing Up To 20 kHz with the high frequency option.

HF

Audiometry and Wireless REM/LSM In One Compact Device

• Complete Air, Bone, Speech and Masking Audiometry

• Tinnometer Software Compatible

• Built-in Special Tests, Word Lists, and Auto-Scoring

• Audiometry Testing up to 20,000 Hz with

High-Frequency Option

• Wireless, Binaural Live Speech Mapping and Real

Ear Measurements

• REM Autofit Capable

• 3rd Party Counseling and Demonstration with

Hearing Loss Simulator and Master Hearing Aid

• PC-Powered with USB Connection and Set-up

• Portable and Compact at Only (L x W x H)

8” x 5” x 1.25”

• Noah, TIMS, Blueprint OMS, and Sycle compatible

MedRx AWRC The MedRx AWRC is a complete dual-channel audi-ometer and high frequency wireless REM/LSM system combined for convenient, space-saving testing and fitting. The 2-in-1 device is optimized for mobile testing or to reduce your equipment’s desktop footprint. With a high frequency audiometer option available, you can ensure you’re choosing features that align best with your prac-tice’s needs. The MedRx AWRC allows you freedom and flexibility to operate at your most efficient.

Contact your local MedRx Sales team to upgrade to high frequency audiometry at any time.

Wireless Real Ear Measurement and Live Speech Mapping MedRx’s modern REM and LSM software modules allow clinicians to fit hearing aids more accurately than ever, improving patient satisfaction and reduc-ing hearing aid returns. Powered only by the USB on your computer, the AWRC comes standard with a high frequency fitting capability that allows clinicians to fit up to 12,500 Hz. The AWRC also uses two wireless Bluetooth probe microphones that connect to your REM system automatically for each fitting session.

Dual-Channel Audiometry MedRx’s audiometry modules allow hearing care pro-viders to perform tests on a modern, easy-to-use software. Use this software to test at 8,000 or out to 20,000 Hz with an optional high frequency add-on.

Audiometer modules always come with built in special tests, QuickSIN, and word lists, and auto-scoring.

Counseling Tools MedRx’s Hearing Loss Simulator (HLS) and Master Hearing Aid Modules (MHA) are available on all AWRC devices, giving providers the tools they need to counsel patients and family members. The HLS demonstrates the effect of the client’s hearing loss for the spouse or family member.

The Master Hearing Aid Simulator (MHA) demonstrates the benefits of a hearing aid to an inexperienced user.

Standards:

REAL EAR MEASUREMENT: Meets Or Exceeds All Tests Required In The ANSI S3.46 Methods Of Measurement Of Real-Ear Performance Charac-teristics Of Hearing Aids, Along With The Require-ments Of IEC 61669 Probe Microphones (L/R): Dual Electret Micro-phone Elements Probe Microphone Tube: Silicone 1.0 mm Nomi-nal Diameter Measurement Range: 40-120 ± 3 dB SPL Measured Frequency Range: 125-12500 Hz Test Stimuli: Broadband Noise And Synthesized Random Noise – Pink, White, Byrne LTASS And ANSI Weighted; ICRA; ISTS Microphone, File, CD- ROM For Live Speech Mapping, Chirp Test Stimulus Levels At 1m: 40-90 dB SPL In 1 dB Steps – 200 Hz Through 12500 Hz (Depending On Speaker Wattage And Efficiency) Test Stimulus Accuracy: ± 3dB SPL Equalization: Pressure Method Analysis Mode: User Selectable 1/3, 1/6, 1/9, 1/12, 1/24, 1/48 Octave Bands ANSI S3.46 Test Available IEC 61669: Real Ear Un-aided Response, Real Ear Unaided Gain, Real Ear Insertion Gain, Real Ear Occluded Response, Real Ear Occluded Gain, Real Ear Aided Response, Real Ear Aided Gain Other Tests Available: Live Speech Mapping With Peaks And LTAS Analysis; Real Ear To Coupler Dif-ference, Occlusion Effect, Percentile Analysis Prescription Methods: NAL-RP, 1/3 Gain, 1/2 Gain, Berger, Pogo 1, Pogo 2, FIG6, DSL m[I/O], NAL-NL1, NAL-NL2

Probe Monitoring: Available With Operator Headset

REM EXTERNAL CONNECTIONS

Power Connection: USB 3.0 Input 5.0 Volt Bus USB 3.0 Input: Standard USB “C” Socket

Line-Output Jack (REM Or Audiometry Speakers):

3.5mm Stereo Jack Speaker Output (Internal Amplifier) (2): 3.81mm Pluggable Spring Clamp Probe Microphones inputs: Bluetooth Operator Headset Jack (REM Or Audiometry):

3.5mm Stereo Jack Patient Headset Jack (Client): 3.5mm Stereo Jack, Power Jack: 2.1mm X 5.5mm

HEARING LOSS SIMULATOR AND HEARING AID

SIMULATOR: Software Based Sound Equalization With Available Live Speech Mapping Functionality.

Frequency Range 125Hz – 8000 Hz, 13 Band Equalizer Standards:

AUDIOMETRY: ANSI S3.6 Type 1 HFAE (IEC 60645- 1 & 2), Tone Audiometry, Speech Audiometry, Stenger Test, QuickSIN™, ABLB, SISI, Tone Decay, Hughson Westlake Automated Audiometry Channels: Two Outputs: Insert Earphones, Headphones, Bone Conductor, Free Field - Line Level Output Or Inter-nal Amplifier Tone Stimuli: Pure Tone, Warble Tone, Continuous Or Pulsed, Warble Modulation Frequency And Pulse Period Are User Adjustable Masking Signals: Tone Audiometry: Narrow Band Noise (default), Speech Weighted Noise, White Noise. Speech Audiometry: Speech Weighted Noise (Default), White Noise, External Recorded (Opposite Channel) Frequency Range USB Power Only: Air: 125 Hz – 20000 Hz, Bone: 250 Hz – 8000 Hz Sound Field: 125Hz – 8000Hz (Line Level) Acoustic Distortion: < 1.0% At 500 Hz, 100dB SPL Noise Floor: < -10dB HL From 125 Hz – 20000 Hz Attenuation: 1dB or 5dB Steps, User Selectable Minimum / Maximum Output: -10 dB To 120 dB HL At 1 KHz – Air (¼ Inch Mono Jacks), -10 dB To 75 dB HL At 1 KHz – Bone (¼ Inch Mono Jack)

Free Field Output: Frequency Range 125 - 8000 Hz, Dynamic Range 60-90+ dB SPL At 1 Meter Dis-tance, (Using 50 Watt Stereo Amplifier With 89 dB Sensitivity Speakers) Speech Input: Microphone (3.5 mm Stereo Jacks) I/O Jacks – 3.5mm: Operator Headphones (Out-put Shared With REM), Operator Talk Forward Microphone, Patient Talk Back Microphone, Free Field (Line Out Shared With REM) I/O Jacks – 1/4”: 2 Left Air Conduction, 2 Right Air Conduction, Bone Conduction, Patient Response Switch

POWER (FOR BOTH REM & AUDIOMETRY) USB

3.0 Input: 5.0 Volt Bus

Max Power Consumption: Less Than 900 mA At

5.0 Volts

Power Supply - Internal Speaker Amp: 15V DC, 2A Optional Powered Speakers: 120V, 60 Hz Or 100V

– 240V, 50/60 Hz Available Power Supply: USB To Computer Operating Temperature: 10°C To 35°C Operating Humidity: 30% To 90% Storage Temperature: -20°C To 50°C Storage Humidity: 10% To 90% Dimensions: Approx. 20 cm x 12 cm x 3 cm (L x W x H) Approx. 8” x 5” x 1.25” (L x W x H) Weight: < 1 kg, < 2 lbs

MedRx Minimum Computer Specs:

Windows® PC compatible computer, Intel™ i5,

2.0 GHz or better. 4 GB RAM. 20 GB free hard

drive space. Available 2.0 USB Port. Windows 10 or 11 Professional (32 Or 64-Bit).

MX-AWRC-DS-1 Rev. 1

MedRx AWRC Technical Specs

MedRx, Inc 1200 Starkey Rd. #105 Largo, FL 33771 U.S.A.