MPEX-04-SPC-504 - Product Specification for a Water-Cooled Gate Valve (1).pdf
PDF 314 KB Posted
- Attached to
- Vacuum Gate Valves
- Solicitation number
- PR389124
- Issued by
-
Department of Energy
About this file
This document is a Product Specification for a Water Cooled Gate Valve for the Material Plasma Exposure Experiment (MPEX) at Oak Ridge National Laboratory. The specification details precise requirements for a gate valve with DN275CF (Conflat) sealing features, including 30 3/8-24 tapped holes on a 12.060" bolt circle, four leak check grooves, and specific dimensional tolerances. The valve must be constructed of Grade 316 Stainless Steel and meet stringent vacuum performance standards, with leak rates of <1x10-10 mbar ls-1 for flanges and <1x10-8 mbar ls-1 for valve body and seat.
The gate valve must provide water cooling capable of removing 2.5 kW, operate with 85°F water at 5 GPM and 220 psig, and withstand bakeout temperatures up to 150°C. It shall be capable of operating in a 1.0 Tesla magnetic field, controlled remotely with 30 ft of cable/hose, and able to transmit open/closed position to the MPEX facility I&C system. The specification requires documentation verifying vacuum leak checks, hydrostatic leak checks, bakeout completion, and 100 cyclic opening/closing tests. The valve is being procured by the US Department of Energy under contract with UT-BATTELLE, LLC and Oak Ridge National Laboratory.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MPEX-04-SPC-504-R0
Product Specification for a Water Cooled Gate Valve for the
MATERIAL PLASMA EXPOSURE EXPERIMENT
(MPEX)
Prepared by
OAK RIDGE NATIONAL LABORATORY
Oak Ridge, TN 37831-6283
Managed by
UT-BATTELLE, LLC
For the
US DEPARTMENT OF ENERGY
under contract DE-AC05-00OR22725
This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof.
MPEX-04-SPC-504-R0 Page 2 of 9
Material Plasma Exposure Experiment Oak Ridge National Laboratory
Material Plasma Exposure Experiment Project
MPEX-04-SPC-504
Author(s):
Ted Boyd, Mechanical Engineer Date
Reviewer(s):
Jeff Ulreich, Vacuum SME Date
Aftab Hussain, MPEX Lead Engineer Date
Craig Deibele, MPEX Operations Lead Date
LaTravia Harmon, Quality Assurance Representative Date
Approver(s):
Adam M. Aaron, CAM, Vacuum Systems Date
Distribution:
Phil Ferguson, MPEX Project Director
Robyn Rose, MPEX Project Manager
MPEX-04-SPC-504-R0 Page 3 of 9
MPEX- 04-SPC-504
Revision History
Revision Date DESCRIPTION OF CHANGE
REVISION TYPE
Major Minor
0 July 2023 Initial Issue ☐ ☐
MPEX-04-SPC-504-R0 Page 4 of 9
CONTENTS
ACRONYMS
1 SCOPE
2 INTERCONNECTION FEATURES
3 VACUUM PERFORMANCE
4 MATERIALS
5 EXTERNAL ENVELOPE LIMITATIONS
6 THERMAL PERFORMANCE
6.1 HEAT REMOVAL
6.2 WATER CONNECTIONS
6.3 BAKE OUT
7 CONTROLS
8 TEST AND INSPECTION
9 REFERENCES
MPEX-04-SPC-504-R0 Page 5 of 9
ACRONYMS
ORNL Oak Ridge National Laboratory
TLA Three Letter Acronym
MPEX Material Plasma Exposure Experiment
TPO Technical Project Officer
CAD Computer Aided Design
ECH Electron Cyclotron Heating
ICH Ion Cyclotron Heating
PMI Plasma Material Interaction
NIST National Institute of Standards and Technology
I&C Instrumentation and Controls
P&ID Piping and Instrumentation Design
STEP Standard for the Exchange of Product Data
MPEX-04-SPC-504-R0 Page 6 of 9
1 SCOPE
The specification describes the design requirements for a water cooled gate valve for the MPEX device.
2 INTERCONNECTION FEATURES
The water cooled gate valve must provide interconnection features compatible with DN275CF
(Conflat) sealing features. The gate valve shall provide thirty (30) 3/8-24 tapped holes equally spaced on a 12.060” bolt circle on both sides. The bolt holes shall split the gate valve midplane.
A four leak check grooves shall be added to each face: 2 along the midplane and two perpendicular to the midplane. The distance between the sealing surfaces shall be nominally 4.088” apart with parallel faces and concentric diameters within typical tolerances for standard gate valves of this size. Sealing features must meet the requirements in ASTM E2734/E2734M Standard
Specification for Dimensions of Knife-Edge Flanges[1] and MPEX-00-ENG-002-A2 Vacuum
Handbook Appendix 2: Knife Edge Flange Definition[2].
3 VACUUM PERFORMANCE
Leak rate in flanges:
• Conflat <1x10-10 mbar ls-1
Leak rate when sealed:
• Valve Body < 1x10-8 mbar ls-1
• Valve Seat < 1x10-8 mbar ls-1
4 MATERIALS
The gate valve body shall be constructed of Grade 316 Stainless Steel and meet the permeability requirements in the MPEX Vacuum Handbook [3]. Seals must not outgas beyond the limits of the
MPEX Vacuum Handbook.
5 EXTERNAL ENVELOPE LIMITATIONS
The external features of the gate valve shall not exceed the envelope shown in Figure 1 below:
MPEX-04-SPC-504-R0 Page 7 of 9
Figure 1: Envelope for Water Cooled Gate Valve
MPEX-04-SPC-504-R0 Page 8 of 9
6 THERMAL PERFORMANCE
6.1 HEAT REMOVAL
The gate valve shall provide water cooling capable of removing 2.5 kW from the MPEX device while the gate valve is open to prevent damage to sealing surfaces and operating features of the gate valve. This heat load will only occur when the MPEX plasma is present, and the gate valve is in the open position. The cooling water supplied will be 85°F, 5 GPM, at 220 psig with an allowable pressure drop of up to 17psi.[4]. The 17 psi is nominal. If a greater pressure drop allowance is needed in the design, it must be reviewed and approved by the customer (ORNL).
6.2 WATER CONNECTIONS
The gate valve shall provide ports for cooling water supply and return with standard 0.5 in MNPT
Fittings [5]
Connections shall be located on the external face(s) of the Conflat flange, oriented radially on flange perimeter.
All water connections and passageways shall conform to ASTM E1003 for hydrostatic leak checking at 330 psig.
6.3 BAKE OUT
The gate valve shall be able to operate with 150 C water continually flowing through the water channels as part of the MPEX Bakeout Process. All vacuum surfaces shall be allowed to reach 150
C. Critical components may be provided cooling via air or water upon request and review with the buyer.
7 CONTROLS
The gate valve shall be capable of operating while in a 1.0 Tesla magnetic field.
The gate valve shall be controlled remotely by cables and hoses capable of connecting to the
MPEX facility I&C system and pneumatics.
30 ft minimum of cable or hose shall be provided for each gate valve
The position of the gate valve, fully open, full closed, must be transmitted to the MPEX facility
I&C system. Unless fully opened or closed, neither position should be transmitted.
8 TEST AND INSPECTION
Documentation shall be provided verifying the performance and results of the following tests:
1. Vacuum Leak Check per Section 3.
2. Hydrostatic Leak Check per Section 6.2.
MPEX-04-SPC-504-R0 Page 9 of 9
3. Completion of Bake Out per Section 6.3 and operation after cooling to ambient temperature.
4. Cyclic testing - Operation of the gate valve shall be verified and repeated for 100 opening and closing cycles.
9 REFERENCES
[1] ASTM E2734/E2734M Standard Specification for Dimensions of Knife-Edge Flanges
[2] MPEX-00-ENG-002-A2 Vacuum Handbook Appendix 2: Knife Edge Flange Definition
[3] MPEX-00-ENG-002 MPEX Vacuum Handbook
[4] MPEX-04-ENG-003 MPEX Near-Device Water Client Parameter Summary
[5] MPEX-04-PKG-501 Engineering Drawing Package for On-Device water Schematics
| 1 SCOPE |
| 2 interconnection features |
| 3 VACUUM PERFORMANCE |
| 4 MATERIALS |
| 5 external envelope limitations |
| 6 Thermal Performance |
| 6.1 heat removal |
| 6.2 water connections |
| 6.3 Bake Out |
| 7 controls |
| 8 Test and inspection |
| 9 REFERENCES |
| 2023-07-20T14:47:19-0400 | |
| Ted Boyd |
| 2023-07-20T14:53:32-0400 | |
| Jeffrey Ulreich |
| 2023-07-22T22:24:17-0400 | |
| Aftab Hussain |
| 2023-07-24T07:52:20-0400 | |
| Dr. Craig Deibele |
| 2023-07-24T08:28:53-0400 | |
| LaTravia N Harmon |
| 2023-08-03T14:37:23-0400 | |
| Robyn Rose |
File details come from the government source that posted it. Updated .