This document is a Statement of Objectives (SOO) for the installation of a groundwater monitoring well near Building 3703 at Shaw Air Force Base. The key objectives are:

The contractor shall install a groundwater monitoring well in the vicinity of the replaced spill bucket associated with the premium unleaded gasoline underground storage tank (UST). The contractor shall use a private utility locator and an air knife to preclear the drilling location to a depth of 5 feet to avoid underground impediments. The contractor shall collect a water sample at the appropriate depth and submit it for laboratory analysis of volatile organic compounds, ethylene dibromide, and lead. The contractor shall summarize the results in a Site Check Report sealed by a North Carolina licensed geologist or engineer. If the initial testing is unsatisfactory, the well must remain open and additional testing may be required. Once testing is satisfactory, the well can be filled back in.

The related federal contract opportunity is Solicitation Number FA480924R0017 issued by the Department of the Air Force, Air Combat Command, to install the groundwater monitoring well in accordance with the attached SOO.

View the file

Other files for this federal contract opportunity

Other files attached to Monitoring Well, newest first.
File Type Posted
WD NC20240012.pdf PDF
STIRA Guidelines 2021.pdf PDF
Solicitation - FA480924R0017.pdf PDF
SJAFB Climatic Data Summary.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12 July 2024 Statement of Objectives:

The contractor shall install a groundwater monitoring well in the vicinity of the replaced spill bucket associated with the premium unleaded gasoline underground storage tank (UST) at the AAFES Convenience Store, Building 3703. To avoid underground impediments, including active UST components, the contractor shall provide a private utility locator and an air knife to preclear the drilling location to a depth of five (5) feet below grade surface. Upon completion, the well will be developed and sampled. The contractor shall collect a water sample at the appropriate depth, as specified by the North Carolina Department of Environmental Quality (NCDEQ). Drill cuttings, purge/development water, and investigative derived waste (IDW) will be placed in separate 55-gallon drums, labeled, and staged on-site in a location determined by base environmental personnel (4CES/CEIE). If the removed material cannot be used to fill in the well upon evolution completion, SJAFB 4CES/CEIE shall handle the transportation and disposal costs of the containerized cuttings, development water, and IDW. The contractor shall submit the collected groundwater sample for laboratory analyses of volatile organic compounds (VOCs) and oxygenates using EPA Method 6200B, EDB using EPA Method 504.1, lead using EPA Method 6010B and MADEP Method VPH, in accordance with NCDEQ guidelines. The contractor shall submit a trip blank for laboratory analysis of VOCs using EPA Method 6200B. The contractor shall summarize the results of the monitoring well installation and sampling activities in a Site Check Report. The Site Check Report shall include all appropriate maps, laboratory analytical data, copies of laboratory reports and chains-of-custody, data interpretation, conclusions, and recommendations. This report shall be sealed by a North Carolina licensed geologist or engineer and will be suitable for submittal to NCDEQ.

Note: If the initial testing does not come back satisfactory, the well must remain open and additional testing is likely. This will be determined and if necessary, a modification for additional testing can be anticipated. After all testing is satisfactory, then the well can be filled back in with the appropriate soil.

File details come from the government source that posted it. Updated .