Modular Building Information for RFI.pdf

PDF 1 MB Posted

Attached to
NEW MODULAR HOUSE FOR STAFF HOUSING
Solicitation number
RFI-01950
Issued by
Leon County, Florida

About this file

The document provided is a Request for Information (RFI) from the Florida Fish and Wildlife Conservation Commission (FWC) seeking information from prospective vendors for the provision of new modular houses for staff housing at FWC's wildlife management areas. The RFI outlines the general requirements for the modular houses, including specifications for the floor, walls, roof, doors, windows, electrical, plumbing, HVAC, millwork, and appliances. The modular houses must be able to accommodate gutters and downspouts, be designed for a wind load of at least 150 mph, and include impact-resistant windows and doors. The RFI does not provide specific item quantities, response dates, award dates, or contract terms, but indicates that the proposed building must be able to be provided as a turn-key product.

The RFI does not include details on pricing terms, set-asides, incumbents, funding requirements or sources, or other salient commercial information. Interested vendors are advised to review the RFI and any related documentation for a comprehensive understanding of the requirements and to prepare their responses accordingly.

View the file

Other files

File Type Posted
FWC 21.22-115 New Modular House Final.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TURNPIKE

FLORIDA

FLORIDA

TURNPIKE

(ALLIGATOR ALLEY)

EVERGLADES PARKWAY

M A G N E T

IC

M A G N E T

IC

AutoCAD SHX Text

JEFFERSON

AutoCAD SHX Text p

AutoCAD SHX Text

JACKSON

AutoCAD SHX Text

LEON

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

GADSDEN

AutoCAD SHX Text

WAKULLA

AutoCAD SHX Text

BAY

AutoCAD SHX Text

CALHOUN

AutoCAD SHX Text

GULF

AutoCAD SHX Text

FRANKLIN

AutoCAD SHX Text

LIBERTY

AutoCAD SHX Text Tallahassee

AutoCAD SHX Text p

AutoCAD SHX Text

WALTON

AutoCAD SHX Text

SANTA

AutoCAD SHX Text

ROSA

AutoCAD SHX Text p

AutoCAD SHX Text Pensacola

AutoCAD SHX Text p

AutoCAD SHX Text

NORTHWEST

AutoCAD SHX Text

OKALOOSA

AutoCAD SHX Text

ESCAMBIA

AutoCAD SHX Text p

AutoCAD SHX Text

WASHINGTON

AutoCAD SHX Text

HOLMES

AutoCAD SHX Text

ELLIOT KEY

AutoCAD SHX Text

KEY

AutoCAD SHX Text

RHODES

AutoCAD SHX Text

OLD

AutoCAD SHX Text

KEY LARGO

AutoCAD SHX Text

LOWER

AutoCAD SHX Text

KEY

AutoCAD SHX Text

MATECUMBE

AutoCAD SHX Text

BOOT KEY

AutoCAD SHX Text

KEY

AutoCAD SHX Text

SUMMERLAND

AutoCAD SHX Text

MARQUESAS KEYS

AutoCAD SHX Text

BIG

AutoCAD SHX Text

PINE

AutoCAD SHX Text

KEY

AutoCAD SHX Text Lake

AutoCAD SHX Text Okeechobee

AutoCAD SHX Text

PLANNING AND DESIGN SECTION

AutoCAD SHX Text

PUBLIC ACCESS SERVICES OFFICE

AutoCAD SHX Text

FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION

AutoCAD SHX Text 620 South Meridian Street

AutoCAD SHX Text Tallahassee, FL 32399-1600

AutoCAD SHX Text

FWC PROFESSIONAL ENGINEER

AutoCAD SHX Text

(850) 921-9931

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DATE

AutoCAD SHX Text

INITIAL ISSUE DATE

AutoCAD SHX Text 6/13/22

AutoCAD SHX Text

FWC WILDLIFE MANAGEMENT AREAS

AutoCAD SHX Text

NEW MODULAR HOUSE FOR STAFF HOUSING

AutoCAD SHX Text

FWC WILDLIFE MANAGEMENT AREAS

AutoCAD SHX Text

NEW MODULAR HOUSE FOR STAFF HOUSING

AutoCAD SHX Text G100 COVER COVER G101 MODULAR NOTES MODULAR NOTES C102 FLOOR PLAN EXAMPLEFLOOR PLAN EXAMPLE

AutoCAD SHX Text

INDEX OF DRAWINGS

AutoCAD SHX Text

HAMILTON

AutoCAD SHX Text

GILCHRIST

AutoCAD SHX Text

NORTH CENTRAL

AutoCAD SHX Text

DIXIE

AutoCAD SHX Text

MADISON

AutoCAD SHX Text

TAYLOR

AutoCAD SHX Text

LAFAYETTE

AutoCAD SHX Text

SUWANNEE

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

ALACHUA

AutoCAD SHX Text Gainesville

AutoCAD SHX Text

CITRUS

AutoCAD SHX Text

LEVY

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

UNION

AutoCAD SHX Text

BRADFORD

AutoCAD SHX Text

COLUMBIA

AutoCAD SHX Text

BAKER

AutoCAD SHX Text

CLAY

AutoCAD SHX Text p

AutoCAD SHX Text

NASSAU

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

DUVAL

AutoCAD SHX Text p

AutoCAD SHX Text Jacksonville

AutoCAD SHX Text

ST. JOHNS

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text Daytona Beach

AutoCAD SHX Text p

AutoCAD SHX Text

VOLUSIA

AutoCAD SHX Text

SEMINOLE

AutoCAD SHX Text

ORANGE

AutoCAD SHX Text

NORTHEAST

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

PUTNAM

AutoCAD SHX Text

MARION

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

LAKE

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

SUMTER

AutoCAD SHX Text Orlando

AutoCAD SHX Text

FLAGLER

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

INDIAN

AutoCAD SHX Text

OSCEOLA

AutoCAD SHX Text

RIVER

AutoCAD SHX Text

BREVARD

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text

PASCO

AutoCAD SHX Text

POLK

AutoCAD SHX Text p

AutoCAD SHX Text

HARDEE

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text Tampa

AutoCAD SHX Text St.

AutoCAD SHX Text p

AutoCAD SHX Text

HILLSBOROUGH

AutoCAD SHX Text

MANATEE

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text Petersburg

AutoCAD SHX Text

CHARLOTTE

AutoCAD SHX Text

DESOTO

AutoCAD SHX Text p

AutoCAD SHX Text

LEE

AutoCAD SHX Text p

AutoCAD SHX Text

SARASOTA

AutoCAD SHX Text

HIGHLANDS

AutoCAD SHX Text Clearwater

AutoCAD SHX Text

SOUTHWEST

AutoCAD SHX Text

PINELLAS

AutoCAD SHX Text p

AutoCAD SHX Text

HERNANDO

AutoCAD SHX Text

SOUTH

AutoCAD SHX Text

OKEECHOBEE

AutoCAD SHX Text

MARTIN

AutoCAD SHX Text p

AutoCAD SHX Text West Palm Beach

AutoCAD SHX Text Okeechobee

AutoCAD SHX Text

GLADES

AutoCAD SHX Text Lake

AutoCAD SHX Text

HENDRY

AutoCAD SHX Text

PALM BEACH

AutoCAD SHX Text

ST. LUCIE

AutoCAD SHX Text Ft. Lauderdale

AutoCAD SHX Text p

AutoCAD SHX Text Miami

AutoCAD SHX Text Hollywood

AutoCAD SHX Text p

AutoCAD SHX Text

BROWARD

AutoCAD SHX Text

DADE

AutoCAD SHX Text

ELLIOT KEY

AutoCAD SHX Text

KEY

AutoCAD SHX Text

RHODES

AutoCAD SHX Text

OLD

AutoCAD SHX Text

KEY LARGO

AutoCAD SHX Text

MONROE

AutoCAD SHX Text

LOWER

AutoCAD SHX Text

KEY

AutoCAD SHX Text

MATECUMBE

AutoCAD SHX Text p

AutoCAD SHX Text

COLLIER

AutoCAD SHX Text

BOOT KEY

AutoCAD SHX Text

KEY

AutoCAD SHX Text

SUMMERLAND

AutoCAD SHX Text

MARQUESAS KEYS

AutoCAD SHX Text

BIG

AutoCAD SHX Text

PINE

AutoCAD SHX Text

KEY

AutoCAD SHX Text

DRY TORTUGAS

AutoCAD SHX Text 7000.003

AutoCAD SHX Text

ORANGE COUNTY 28°31'30.44"N 80°59'15.07"W S02 T23S R33E

AutoCAD SHX Text

PROPOSED PROJECT NO.1 LOCATION

AutoCAD SHX Text

PROJECT NO. 1 LOCATION N.T.S.

AutoCAD SHX Text

GLADES COUNTY 26°56'59.10"N 81° 8'10.95"W S33 T40S R32E

AutoCAD SHX Text

PROJECT NO. 2 LOCATION N.T.S.

AutoCAD SHX Text

PROPOSED PROJECT NO.1 LOCATION

AutoCAD SHX Text

PROPOSED PROJECT NO.2 LOCATION

AutoCAD SHX Text

PROPOSED PROJECT NO.2 LOCATION

¾”

AutoCAD SHX Text

PLANNING AND DESIGN SECTION

AutoCAD SHX Text

PUBLIC ACCESS SERVICES OFFICE

AutoCAD SHX Text

FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DATE

AutoCAD SHX Text

PROFESSIONAL REGISTRATION

AutoCAD SHX Text

DESIGNER :

AutoCAD SHX Text STATE PROJECT No.

AutoCAD SHX Text COMP. FILE No.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

INITIAL ISSUE DATE

AutoCAD SHX Text

620 SOUTH MERIDIAN STREET

AutoCAD SHX Text Tallahassee, FL 32301

AutoCAD SHX Text

(850) 921-9931

AutoCAD SHX Text G101

AutoCAD SHX Text

MODULAR NOTES

AutoCAD SHX Text

NEW MODULAR HOUSE FOR STAFF HOUSING

AutoCAD SHX Text

FWC WILDLIFE MANAGEMENT AREAS

AutoCAD SHX Text 7000.003

AutoCAD SHX Text 6/13/22

GENERAL NOTES 1. BUILDING SHALL BE ABLE TO ACCOMMODATE GUTTERS AND DOWNSPOUTS. BUILDING SHALL BE ABLE TO ACCOMMODATE GUTTERS AND DOWNSPOUTS. 2. BUILDING SHALL BE DESIGNED TO THE CURRENT EDITION OF ALL APPLICABLE BUILDING SHALL BE DESIGNED TO THE CURRENT EDITION OF ALL APPLICABLE CODES INCLUDING, BUT NOT LIMITED TO, THE FLORIDA BUILDING CODE, THE INTERNATIONAL BUILDING CODE, AND THE NATIONAL ELECTRIC CODE. 3. BUILDING SHALL BE DESIGNED FOR A WIND LOAD OF AT LEAST 150 MPH. BUILDING SHALL BE DESIGNED FOR A WIND LOAD OF AT LEAST 150 MPH. 4. GLASS FOR WINDOWS AND DOORS SHALL BE IMPACT RESISTANT. GLASS FOR WINDOWS AND DOORS SHALL BE IMPACT RESISTANT. 5. BUILDING SHALL INCLUDE COMMUNICATION CONNECTIONS FOR A LAND LINE. BUILDING SHALL INCLUDE COMMUNICATION CONNECTIONS FOR A LAND LINE. 6. ANY PRODUCTS LISTED BELOW WITH A SPECIFIC MANUFACTURER AND/OR ANY PRODUCTS LISTED BELOW WITH A SPECIFIC MANUFACTURER AND/OR MODEL, CAN BE SUBSTITUTED BY A PRODUCT OF EQUAL OR BETTER QUALITY ON THE SUBMITTAL. FLOOR 1. JOISTS: 2X10 PT LUMBER. JOISTS: 2X10 PT LUMBER. 2. JOIST SPACING: 16” O.C. JOIST SPACING: 16” O.C. O.C. 3. DECKING: ¾” T & G, U.L. PLYWOOD - SINGLE LAYER GLUED AND SCREWED IN. DECKING: ¾” T & G, U.L. PLYWOOD - SINGLE LAYER GLUED AND SCREWED IN. T & G, U.L. PLYWOOD - SINGLE LAYER GLUED AND SCREWED IN. 4. INSULATION: R-19 MINIMUM INSULATION: R-19 MINIMUM 5. COVERING: LUXURY VINYL PLANKS IN ALL AREAS. SMOKEHOUSE BY ELEMENTS COVERING: LUXURY VINYL PLANKS IN ALL AREAS. SMOKEHOUSE BY ELEMENTS OF TILE. EXTERIOR WALLS 1. STUDS: 2X6 #2 SYP, OR EQUAL STUDS: 2X6 #2 SYP, OR EQUAL 2. STUD SPACING: 16” O.C. STUD SPACING: 16” O.C. O.C. 3. TOP PLATE: DOUBLE #2 SYP, OR EQUAL TOP PLATE: DOUBLE #2 SYP, OR EQUAL 4. BOTTOM PLATE: SINGLE #2 SYP, OR EQUAL BOTTOM PLATE: SINGLE #2 SYP, OR EQUAL 5. SHEATHING: PLYWOOD EXTERIOR SHEATHING AND TYVEK HOUSE WRAP UNDER SHEATHING: PLYWOOD EXTERIOR SHEATHING AND TYVEK HOUSE WRAP UNDER SIDING 6. INSULATION: R-19 MINIMUM INSULATION: R-19 MINIMUM 7. SIDING: WOOD-LOOK COMPOSITE. SIDING: WOOD-LOOK COMPOSITE. 8. HIGH DURABILITY EXTERIOR PAINT SHALL BE APPLIED PER PAINT HIGH DURABILITY EXTERIOR PAINT SHALL BE APPLIED PER PAINT MANUFACTURER'S INSTRUCTIONS. COLORS TO BE SELECTED BY FWC PRIOR TO APPLICATION. PAINT TO BE APPLIED IN 2 COATS MINIMUM. INTERIOR WALLS 1. STUDS: 2X4 #2 SYP, OR EQUAL. STUDS: 2X4 #2 SYP, OR EQUAL. 2. STUD SPACING: 16” O.C. STUD SPACING: 16” O.C. O.C. 3. TOP PLATE: DOUBLE #2 SYP OR EQUAL. TOP PLATE: DOUBLE #2 SYP OR EQUAL. 4. BOTTOM PLATE: SINGLE #2 SYP OR EQUAL. BOTTOM PLATE: SINGLE #2 SYP OR EQUAL. 5. COVERING :1/2" DRY WALL WITH PAINT, PEARLTY WHITE SW7009 APPLIED IN 2 COVERING :1/2" DRY WALL WITH PAINT, PEARLTY WHITE SW7009 APPLIED IN 2 COATS MINIMUM. 6. INSULATION: RATED FOR FIRE & SOUND ABATEMENT. INSULATION: RATED FOR FIRE & SOUND ABATEMENT. 7. 3.5 INCH BASE BOARDS, COLOR 3.5 INCH BASE BOARDS, COLOR ROOF 1. RAFTER SPACING: 16” O.C. MAX RAFTER SPACING: 16” O.C. MAX O.C. MAX 2. CEILING HEIGHT: 8'-6” MINIMUM. CEILING HEIGHT: 8'-6” MINIMUM. MINIMUM. 3. INSULATION: R-38 MINIMUM INSULATION: R-38 MINIMUM 4. ROOF DECKING: 7/16” TECH SHIELD ROOF DECKING OR 5/8” CDX PLYWOOD AND ROOF DECKING: 7/16” TECH SHIELD ROOF DECKING OR 5/8” CDX PLYWOOD AND TECH SHIELD ROOF DECKING OR 5/8” CDX PLYWOOD AND CDX PLYWOOD AND SYNTHETIC SECONDARY WATER BARRIER 5. ROOFING: 26 GAUGE METAL ROOFING: 26 GAUGE METAL 6. MINIMUM 12” EAVES ALUMINUM FASCIA WRAP AND VENTILATED SOFFIT, MINIMUM 12” EAVES ALUMINUM FASCIA WRAP AND VENTILATED SOFFIT, EAVES ALUMINUM FASCIA WRAP AND VENTILATED SOFFIT, PRE-FINISHED WHITE. EXTERIOR DOORS 1. DOOR AND HARDWARE STYLES TO BE SELECTED BY FWC FROM THE STANDARD DOOR AND HARDWARE STYLES TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS PROVIDED BY BUILDING MANUFACTURER PRIOR TO PRODUCTION. 2. ALL EXTERIOR DOORS SHALL BE KEYED THE SAME. ALL EXTERIOR DOORS SHALL BE KEYED THE SAME. INTERIOR DOORS 1. DOOR AND HARDWARE STYLES TO BE SELECTED BY FWC FROM THE STANDARD DOOR AND HARDWARE STYLES TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS PROVIDED BY BUILDING MANUFACTURER PRIOR TO PRODUCTION. 2. HARDWARE: LEVERED PRIVACY LOCKSETS FOR THE RESTROOMS, LEVERED HARDWARE: LEVERED PRIVACY LOCKSETS FOR THE RESTROOMS, LEVERED PASSAGES LOCKSETS FOR ALL OTHER ROOMS. 3. FLOOR DOOR STOPS FOR EACH DOOR. FLOOR DOOR STOPS FOR EACH DOOR. WINDOWS 1. IMPACT RESISTANT, LOW-E, DOUBLE GLAZED. IMPACT RESISTANT, LOW-E, DOUBLE GLAZED. 2. WHITE: VINYL, OR ALUMINUM. DOUBLE-HUNG, WITH THERMAL BREAK. WHITE: VINYL, OR ALUMINUM. DOUBLE-HUNG, WITH THERMAL BREAK. 3. WINDOW SILLS: SYNTHETIC, WATER-PROOF. WINDOW SILLS: SYNTHETIC, WATER-PROOF. ELECTRICAL 1. AS DESIGNED BY THE BUILDING MANUFACTURER'S ELECTRICAL ENGINEER TO AS DESIGNED BY THE BUILDING MANUFACTURER'S ELECTRICAL ENGINEER TO MEET ALL APPLICABLE CODES. 2. INCLUDE EXTERIOR ELECTRICAL RECEPTACLES AT FRONT PORCH AND BACK INCLUDE EXTERIOR ELECTRICAL RECEPTACLES AT FRONT PORCH AND BACK PORCH WITH GFCI PROTECTION AND WEATHER-PROOF-IN-USE COVER FOR ALL EXTERIOR RECEPTACLES. 3. INCLUDE AT LEAST 2 MORE EXTERIOR ELECTRICAL RECEPTACLES. INCLUDE AT LEAST 2 MORE EXTERIOR ELECTRICAL RECEPTACLES. 4. INTERIOR LIGHTS TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS INTERIOR LIGHTS TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS PROVIDED BY BUILDING MANUFACTURER. 5. EXTERIOR LIGHTS TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS EXTERIOR LIGHTS TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS PROVIDED BY BUILDING MANUFACTURER. 6. INCLUDE WIRE AND BRACE FOR CEILING FAN AT THE CENTER OF THE LIVING INCLUDE WIRE AND BRACE FOR CEILING FAN AT THE CENTER OF THE LIVING ROOM, EACH BEDROOM AND THE BACK PORCH. FAN AND LIGHT TO BE INDIVIDUALLY SWITCH CONTROLLED. 7. CONTRACTOR TO VERIFY ADEQUACY OF EXISTING ELECTRICAL SERVICE. CONTRACTOR TO VERIFY ADEQUACY OF EXISTING ELECTRICAL SERVICE. CONTRACTOR IS RESPONSIBLE FOR ANY UPGRADES TO THE ELECTRICAL SERVICE, IF NECESSARY. PLUMBING 1. SUPPLY PIPING: CPVC SUPPLY PIPING: CPVC 2. DWV PIPING: SCHEDULE 40 PVC WITH MULTIPLE DROPS, NO MANIFOLD DWV PIPING: SCHEDULE 40 PVC WITH MULTIPLE DROPS, NO MANIFOLD 3. WATER HEATER: (1) 50 GALLON QUICK RETURN ELECTRIC WATER HEATER WATER HEATER: (1) 50 GALLON QUICK RETURN ELECTRIC WATER HEATER 4. MISC SINKS AND FAUCETS TO BE SELECTED FROM STANDARD BUILDING MISC SINKS AND FAUCETS TO BE SELECTED FROM STANDARD BUILDING MANUFACTURER'S OPTIONS DURING SHOP DRAWING REVIEW PROCESS. 5. INCLUDE SHUTOFF VALVE AT EACH PLUMBING FIXTURE. INCLUDE SHUTOFF VALVE AT EACH PLUMBING FIXTURE. 6. PROVIDE AT LEAST TWO EXTERIOR FROST PROOF FAUCETS ON OPPOSITE SIDES PROVIDE AT LEAST TWO EXTERIOR FROST PROOF FAUCETS ON OPPOSITE SIDES OF BUILDING (2 TOTAL). 7. INCLUDE WALK IN SHOWER IN MASTER BATHROOM. INCLUDE WALK IN SHOWER IN MASTER BATHROOM. HVAC 1. TYPE: CENTRAL UNIT SYSTEM SIZED BY BUILDING MANUFACTURER'S MECHANICAL TYPE: CENTRAL UNIT SYSTEM SIZED BY BUILDING MANUFACTURER'S MECHANICAL ENGINEER TO MEET ALL APPLICABLE CODES. 2. DUCTS: SHEET METAL, INSULATED TO R-8 MINIMUM. DUCTS: SHEET METAL, INSULATED TO R-8 MINIMUM. 3. EXHAUST FANS: ONE IN EACH BATHROOM, VENTED THROUGH ROOF, SIZED BY EXHAUST FANS: ONE IN EACH BATHROOM, VENTED THROUGH ROOF, SIZED BY BUILDING MANUFACTURER'S MECHANICAL ENGINEER. 4. RESIDENTIAL HOOD MOUNTED TO UNDERSIDE OF OVERHEAD CABINET, VENTED RESIDENTIAL HOOD MOUNTED TO UNDERSIDE OF OVERHEAD CABINET, VENTED THROUGH ROOF SIZED BY BUILDING MANUFACTURER'S MECHANICAL ENGINEER. 5. THERMOSTAT: PROGRAMMABLE. THERMOSTAT: PROGRAMMABLE. MILLWORK 1. SOFT CLOSE DOOR HINGES WITH FULL EXTENSION SOFT CLOSE DRAWER GUIDES. SOFT CLOSE DOOR HINGES WITH FULL EXTENSION SOFT CLOSE DRAWER GUIDES. 2. UV PROTECTED PLYWOOD CABINET CONSTRUCTION. UV PROTECTED PLYWOOD CABINET CONSTRUCTION. 3. HARDWARE AND COUNTERTOP STYLES TO BE SELECTED BY FWC FROM THE HARDWARE AND COUNTERTOP STYLES TO BE SELECTED BY FWC FROM THE STANDARD OPTIONS PROVIDED BY BUILDING MANUFACTURER DURING SHOP DRAWING REVIEW PERIOD. 4. KITH SHAKER CABINETS IN ASH COLOR. KITH SHAKER CABINETS IN ASH COLOR. 5. INCLUDE ONE 30” WIDE CABINET STACK FOR PANTRY. INCLUDE ONE 30” WIDE CABINET STACK FOR PANTRY. WIDE CABINET STACK FOR PANTRY. FIRE PROTECTION 1. RATED CONSTRUCTION: NO EXTERIOR OR INTERIOR FIRED RATED ASSEMBLIES RATED CONSTRUCTION: NO EXTERIOR OR INTERIOR FIRED RATED ASSEMBLIES 2. FIRE ALARM: NONE. FIRE ALARM: NONE. 3. FIRE SPRINKLER: NONE FIRE SPRINKLER: NONE 4. FIRE EXTINGUISHERS: AS REQUIRED BY THE FIRE CODE FOR THE PROVIDED FIRE EXTINGUISHERS: AS REQUIRED BY THE FIRE CODE FOR THE PROVIDED BUILDING. 5. SMOKE DETECTORS: AS REQUIRED BY THE FIRE CODE FOR THE PROVIDED SMOKE DETECTORS: AS REQUIRED BY THE FIRE CODE FOR THE PROVIDED BUILDING. APPLIANCES 1. INCLUDE STOVE, REFRIGERATOR AND DISHWASHER. INCLUDE STOVE, REFRIGERATOR AND DISHWASHER. 2. PROVIDE ALL UTILITY HOOK UPS FOR WASHER AND DRYER. PROVIDE ALL UTILITY HOOK UPS FOR WASHER AND DRYER.

MASTER BEDROOM

AutoCAD SHX Text

DINING

AutoCAD SHX Text

#3 BED

AutoCAD SHX Text

LIVING ROOM

AutoCAD SHX Text

FOYER

AutoCAD SHX Text

#2 BED

AutoCAD SHX Text

PORCH

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

FAUCET

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text w/RAG

AutoCAD SHX Text F

AutoCAD SHX Text

METAL DOOR

AutoCAD SHX Text

M.BATH

AutoCAD SHX Text

UTIL

AutoCAD SHX Text

DS

AutoCAD SHX Text

PB

AutoCAD SHX Text

#2 BATH

AutoCAD SHX Text W/H

AutoCAD SHX Text

FULL LENGTH 3-LAYER RIDGE BEAM

AutoCAD SHX Text

PANTRY

AutoCAD SHX Text

DS

AutoCAD SHX Text

CL

AutoCAD SHX Text

AREA FOR WASHER AND DRYER

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

OPTIONAL PORCH

AutoCAD SHX Text

PLANNING AND DESIGN SECTION

AutoCAD SHX Text

PUBLIC ACCESS SERVICES OFFICE

AutoCAD SHX Text

FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DATE

AutoCAD SHX Text

PROFESSIONAL REGISTRATION

AutoCAD SHX Text

DESIGNER :

AutoCAD SHX Text STATE PROJECT No.

AutoCAD SHX Text COMP. FILE No.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

INITIAL ISSUE DATE

AutoCAD SHX Text

620 SOUTH MERIDIAN STREET

AutoCAD SHX Text Tallahassee, FL 32301

AutoCAD SHX Text

(850) 921-9931

AutoCAD SHX Text G102

AutoCAD SHX Text

FLOOR PLAN EXAMPLE

AutoCAD SHX Text

NEW MODULAR HOUSE FOR STAFF HOUSING

AutoCAD SHX Text

FWC WILDLIFE MANAGEMENT AREAS

AutoCAD SHX Text 7000.003

AutoCAD SHX Text 6/13/22

NOTES: 1. THE BUILDING SHOWN REPRESENTS THE BUILDING SHOWN REPRESENTS THE GENERAL INTENT OF THE NEW RESIDENTIAL STRUCTURE. MODULAR STRUCTURES OF EQUIVALENT SIZE AND FEATURES WILL BE CONSIDERED. 2. ALL DIMENSIONS SHOWN ON THE ALL DIMENSIONS SHOWN ON THE FLOOR PLAN ARE APPROXIMATE. 3. PROPOSED BUILDING MUST BE PROPOSED BUILDING MUST BE ABLE TO BE PROVIDED AS A TURN KEY PRODUCT.

File details come from the government source that posted it. Updated .