MEZZANINE SPECS - 1301070774.pdf
PDF 561 KB Posted
- Solicitation number
- N00173-23-Q-0254
About this file
This document contains draft requirements for a mezzanine procurement at the Naval Research Laboratory in Key West, Florida. The mezzanine will be used for storage and require a minimum 150 pound per square foot resin composite flooring that can support a 500 pound loaded pallet jack in any location, as well as specified shelf and point loading. Bidders must provide engineering drawings and inspection of the site, a stamped design, and painted or powder coated steel. Installation may be bid separately. The related federal contract opportunity is solicitation number N00173-23-Q-0254 from the Department of the Navy Secretary of the Navy Office of Naval Research to purchase and install the mezzanine.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IOA - 1301070774.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFT REQURIEMENTS FOR NRLKW F1A MEZZANINE PROCUREMENT
1. The mezzanine will be used for storage of materials and parts.
2. The mezzanine floor shall be of the resin composite type. The flooring shall be fastened down to the deck.
3. The mezzanine floor shall be a minimum of 150 lb/sq.ft. over the entire area. The floor shall accommodate a 500 lb loaded pallet jack at any location. The floor shall accommodate shelf and point loading specified in the drawing.
4. If larger beams and shorter spans are required to carry the point loading, these beam sizes and spans shall be carried along the complete North, South, and West sides of the Mezzanine to permit the end user to reconfigure the shelving layout after installation.
5. The offerer shall provide a quote that does not include stair landings and adjust the clearance height in order to achieve a deck height that does not require stair landings.
6. The mezzanine shall meet all applicable codes, including State of Florida building code, IBC, AISC, ASTM, and OSHA.
7. The offerer shall travel on-site to take final measurements for the engineering drawings. If the
Mezzanine does not fit during the installation the offerer will work to correct, at no added cost to the purchaser.
8. The offerer shall supply a PE Stamp on the final design.
9. All steel shall be painted or powder coated. The color will be specified after contract award.
10. If installation is an offered service it is requested that it is bid as a separate line item.
11. If the end user will assemble the mezzanine. Drawings and installation instructions shall be provided.
48'-1"
66'-0"
6'-0" 12'-0" 12'-0" 6'-0"
8'-0"
RAMP RAMP
EL
EC
TR
IC
A L
A/C
PACK.
UNIT
/2
A
IK
EN
ST
RU
T
PV
C R
A C
K
DUMP
SELF-SUPPORTING MEZZANINE
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THESE
DRAWINGS IS THE SOLE PROPERTY OF THE
U.S. NAVAL RESEARCH LABORATORY (NRL).
ANY REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN PERMISSION
OF NRL IS STRICTLY PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
U.S. NAVAL RESEARCH LABORATORY
DRAWN
CHECKED
DATENAME
TITLE:
SIZE
B
DWG. NO. REV
SCALE: 1:100
UNLESS OTHERWISE SPECIFIED:
RAM
SHEET 1 OF 4DO NOT SCALE DRAWING
APPLICATION: SOLIDWORKS 2016
NAVAL RESEARCH LABORATORY
TRUMBO POINT ANNEX - FLEMMING KEY
BUILDING F14
KEY WEST, FL 33041
SITE F-1A
MACHINE SHOP
65'-0"
20'-0"
22'-0"
10'-2" MIN
50'-0"
12'-0"
RESIN COMPOSITE FLOORING
150 LB/SQ.FT ON TOTAL AREA
SUPPORTS AS REQUIRED
RAILING
MATERIAL TRANSFER
GATE
STAIRCASE LADDER
HANDRAIL
THIS SIDE ONLY
NO COLUMNS
INTERIOR SPACE
65'-0"
20'-0"
22'-0"
10'-2" MIN
50'-0"
12'-0"
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
SIZE
B
DWG. NO. REV
WEIGHT: SCALE: 1:100 SHEET 2 OF 4
| F1A Machine Shop-20230130.PDF |
| Sheet1 |
| Sheet2 |
File details come from the government source that posted it. Updated .