MetroStor_MFXP-0002_FXG-65FP_TECH_2D_Imperial.pdf

PDF 801 KB Posted

Attached to
FOOD WASTE COLLECTION
Solicitation number
23/24-28
Issued by
Hartford County, Connecticut

About this file

The provided technical drawing is a detailed specification document for the MetroStor FXG-65_FP unit, created by Streetspace Ltd, located in Lympne Industrial Park, Hythe, Kent, United Kingdom. The four-page technical drawing provides comprehensive dimensional details for a green and dark-colored storage unit, including precise measurements for unit dimensions, ground fixing details, hatch/aperture specifications, and signage space areas. The drawings include multiple view perspectives (front, right, left, top) and provide installation notes specifying base dimension requirements and surface regularity.

The technical drawings note that all dimensions are in inches, and the documents are marked "FOR INFORMATION" with revision 00, issued on 09/10/2023. The specifications include critical installation guidance, such as requiring base dimensions to be oversized by a minimum of 4 inches from ground anchor centers on hard standing surfaces, and mandating a surface achieving regularity of +/- 0.3 inches from the planned level within the overall unit dimensions. While directly linked to a potential food waste collection contract for the Town of Manchester, Connecticut, these technical drawings appear to be a standard product specification for a storage unit that could potentially be used in municipal waste management programs.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

34.9

OPENING WIDTH

.8

O

PE

N

IN

G H

EI

G

HT

FRONT

DOOR HIDDEN FOR DEMONSTRATIVE PURPOSES

33.7

DEPTH AT TOP

.1

HE

IG

HT

A

T

FR

O N

T

.8

HE

IG

HT

A

T

RE

A R

RIGHT

32.6

WIDTH AT TOP

32.0

WIDTH AT BASE

REAR

VIEWTOPVIEWTOP

.0

D O

O R

C

LE

A

RA

N C

E

105°

OPENING

ANGLE

SECTION VIEW

TOP

metroSTOR FXG_65_FP UNIT DIMENSIONS

Drawing Notes:

Access control and cladding type• for illustration purposes only.

Dimensions in Inches.•

This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.

Streetspace Ltd.

Lympne Industrial Park Hythe Kent

CT21 4LR

01227 200404 www.streetspacegroup.co.uk

Status

Rev. Drawn by

Drawn Date

Check by

Approved by Part No.

Description

RevisionDrawn By

Approved By

Date

Date

Issue

DetailsEnsure the drawing is the correct issue & release before using.

ISO A3 Landscape ALL DIMENSIONS IN mm

DO NOT SCALE

00FOR INFORMATION

LFXP-0002

FXG-65_MAIN BODY_ASSEMBLY

IS

09/10/2023

.8

A

PE

RT

UR

E

HE

IG

HT

.2

HA

TC

H

HA

N D

LE

O

PE

N

H

EI

G

HT

A

PE

RT

UR

E

D

EP

TH

APERTURE WIDTH

8.

A

PE

RT

UR

E

SE

TB

A

C K

HATCH HIDDEN FOR DEMONSTRATIVE PURPOSESmetroSTOR FXG-65_FP HATCH/APERTURE DETAIL

Drawing Notes:

Dimensions in Inches.•

This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.

Streetspace Ltd.

Lympne Industrial Park Hythe Kent

CT21 4LR

01227 200404 www.streetspacegroup.co.uk

Status

Rev. Drawn by

Drawn Date

Check by

Approved by Part No.

Description

RevisionDrawn By

Approved By

Date

Date

Issue

DetailsEnsure the drawing is the correct issue & release before using.

ISO A3 Landscape ALL DIMENSIONS IN mm

DO NOT SCALE

00FOR INFORMATION

LFXP-0002

FXG-65_MAIN BODY_ASSEMBLY

30.8

0.

7.

28.0

14.0 14.0

2.1 2.1

.8 metroSTOR FXG_65_FP GROUND FIXING DETAILS

Installation Notes:

Base dimensions should be oversized by a minimum of 4• inches from centre of any ground anchor on a hard standing surface.

Suitable surface achieving regularity of+/- 0.3inches from• planned level within the overall dimensions of the unit is required Dimensions in inches•

This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.

Streetspace Ltd.

Lympne Industrial Park Hythe Kent

CT21 4LR

01227 200404 www.streetspacegroup.co.uk

Status

Rev. Drawn by

Drawn Date

Check by

Approved by Part No.

Description

RevisionDrawn By

Approved By

Date

Date

Issue

DetailsEnsure the drawing is the correct issue & release before using.

ISO A3 Landscape ALL DIMENSIONS IN mm

DO NOT SCALE

00FOR INFORMATION

LFXP-0002

FXG-65_MAIN BODY_ASSEMBLY

1.

25.6

FRONT

FRONT DOOR SIGNAGE

AREA

22.0

0.

LEFT

LEFT PANEL

SIGNAGE AREA

22.0

0.

RIGHT

RIGHT PANEL

SIGNAGE AREA

metroSTOR FXG_65_FP SIGNAGE SPACE DIMENSIONS

Drawing Notes:

Dimensions in Inches.•

This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.

Streetspace Ltd.

Lympne Industrial Park Hythe Kent

CT21 4LR

01227 200404 www.streetspacegroup.co.uk

Status

Rev. Drawn by

Drawn Date

Check by

Approved by Part No.

Description

RevisionDrawn By

Approved By

Date

Date

Issue

DetailsEnsure the drawing is the correct issue & release before using.

ISO A3 Landscape ALL DIMENSIONS IN mm

DO NOT SCALE

00FOR INFORMATION

LFXP-0002

FXG-65_MAIN BODY_ASSEMBLY

Sheet1
Drawing View11
Drawing View12
Drawing View13
Drawing View14
Drawing View17
Drawing View19
Section View VIEWTOP-VIEWTOP
Sheet3
Drawing View23
Drawing View24
Drawing View25
Sheet2
Drawing View21
Section View -
Sheet4
Drawing View26
Drawing View27
Drawing View28

File details come from the government source that posted it. Updated .