MetroStor_MFXP-0002_FXG-65FP_TECH_2D_Imperial.pdf
PDF 801 KB Posted
- Attached to
- FOOD WASTE COLLECTION
- Solicitation number
- 23/24-28
- Issued by
- Hartford County, Connecticut
About this file
The provided technical drawing is a detailed specification document for the MetroStor FXG-65_FP unit, created by Streetspace Ltd, located in Lympne Industrial Park, Hythe, Kent, United Kingdom. The four-page technical drawing provides comprehensive dimensional details for a green and dark-colored storage unit, including precise measurements for unit dimensions, ground fixing details, hatch/aperture specifications, and signage space areas. The drawings include multiple view perspectives (front, right, left, top) and provide installation notes specifying base dimension requirements and surface regularity.
The technical drawings note that all dimensions are in inches, and the documents are marked "FOR INFORMATION" with revision 00, issued on 09/10/2023. The specifications include critical installation guidance, such as requiring base dimensions to be oversized by a minimum of 4 inches from ground anchor centers on hard standing surfaces, and mandating a surface achieving regularity of +/- 0.3 inches from the planned level within the overall unit dimensions. While directly linked to a potential food waste collection contract for the Town of Manchester, Connecticut, these technical drawings appear to be a standard product specification for a storage unit that could potentially be used in municipal waste management programs.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
34.9
OPENING WIDTH
.8
O
PE
N
IN
G H
EI
G
HT
FRONT
DOOR HIDDEN FOR DEMONSTRATIVE PURPOSES
33.7
DEPTH AT TOP
.1
HE
IG
HT
A
T
FR
O N
T
.8
HE
IG
HT
A
T
RE
A R
RIGHT
32.6
WIDTH AT TOP
32.0
WIDTH AT BASE
REAR
VIEWTOPVIEWTOP
.0
D O
O R
C
LE
A
RA
N C
E
105°
OPENING
ANGLE
SECTION VIEW
TOP
metroSTOR FXG_65_FP UNIT DIMENSIONS
Drawing Notes:
Access control and cladding type• for illustration purposes only.
Dimensions in Inches.•
This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.
Streetspace Ltd.
Lympne Industrial Park Hythe Kent
CT21 4LR
01227 200404 www.streetspacegroup.co.uk
Status
Rev. Drawn by
Drawn Date
Check by
Approved by Part No.
Description
RevisionDrawn By
Approved By
Date
Date
Issue
DetailsEnsure the drawing is the correct issue & release before using.
ISO A3 Landscape ALL DIMENSIONS IN mm
DO NOT SCALE
00FOR INFORMATION
LFXP-0002
FXG-65_MAIN BODY_ASSEMBLY
IS
09/10/2023
.8
A
PE
RT
UR
E
HE
IG
HT
.2
HA
TC
H
HA
N D
LE
O
PE
N
H
EI
G
HT
A
PE
RT
UR
E
D
EP
TH
APERTURE WIDTH
8.
A
PE
RT
UR
E
SE
TB
A
C K
HATCH HIDDEN FOR DEMONSTRATIVE PURPOSESmetroSTOR FXG-65_FP HATCH/APERTURE DETAIL
Drawing Notes:
Dimensions in Inches.•
This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.
Streetspace Ltd.
Lympne Industrial Park Hythe Kent
CT21 4LR
01227 200404 www.streetspacegroup.co.uk
Status
Rev. Drawn by
Drawn Date
Check by
Approved by Part No.
Description
RevisionDrawn By
Approved By
Date
Date
Issue
DetailsEnsure the drawing is the correct issue & release before using.
ISO A3 Landscape ALL DIMENSIONS IN mm
DO NOT SCALE
00FOR INFORMATION
LFXP-0002
FXG-65_MAIN BODY_ASSEMBLY
30.8
0.
7.
28.0
14.0 14.0
2.1 2.1
.8 metroSTOR FXG_65_FP GROUND FIXING DETAILS
Installation Notes:
Base dimensions should be oversized by a minimum of 4• inches from centre of any ground anchor on a hard standing surface.
Suitable surface achieving regularity of+/- 0.3inches from• planned level within the overall dimensions of the unit is required Dimensions in inches•
This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.
Streetspace Ltd.
Lympne Industrial Park Hythe Kent
CT21 4LR
01227 200404 www.streetspacegroup.co.uk
Status
Rev. Drawn by
Drawn Date
Check by
Approved by Part No.
Description
RevisionDrawn By
Approved By
Date
Date
Issue
DetailsEnsure the drawing is the correct issue & release before using.
ISO A3 Landscape ALL DIMENSIONS IN mm
DO NOT SCALE
00FOR INFORMATION
LFXP-0002
FXG-65_MAIN BODY_ASSEMBLY
1.
25.6
FRONT
FRONT DOOR SIGNAGE
AREA
22.0
0.
LEFT
LEFT PANEL
SIGNAGE AREA
22.0
0.
RIGHT
RIGHT PANEL
SIGNAGE AREA
metroSTOR FXG_65_FP SIGNAGE SPACE DIMENSIONS
Drawing Notes:
Dimensions in Inches.•
This is property of Streetspace Ltd and shall not be disclosed, duplicated or used without formal consent.
Streetspace Ltd.
Lympne Industrial Park Hythe Kent
CT21 4LR
01227 200404 www.streetspacegroup.co.uk
Status
Rev. Drawn by
Drawn Date
Check by
Approved by Part No.
Description
RevisionDrawn By
Approved By
Date
Date
Issue
DetailsEnsure the drawing is the correct issue & release before using.
ISO A3 Landscape ALL DIMENSIONS IN mm
DO NOT SCALE
00FOR INFORMATION
LFXP-0002
FXG-65_MAIN BODY_ASSEMBLY
| Sheet1 |
| Drawing View11 |
| Drawing View12 |
| Drawing View13 |
| Drawing View14 |
| Drawing View17 |
| Drawing View19 |
| Section View VIEWTOP-VIEWTOP |
| Sheet3 |
| Drawing View23 |
| Drawing View24 |
| Drawing View25 |
| Sheet2 |
| Drawing View21 |
| Section View - |
| Sheet4 |
| Drawing View26 |
| Drawing View27 |
| Drawing View28 |
File details come from the government source that posted it. Updated .