MDVL212104 Construction Drawings (5 Mar 2022).pdf

PDF 666 KB Posted

Attached to
MDVL212104 - Renovate Squad Ops Break Room Bldg. 308
Solicitation number
W50S7J22B0002
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENOVATE bREAkROOm AT bUILDING 308

PN mDVL212104

186TH AIR REFUELING WING

mISSISSIPPI AIR NATIONAL GUARD kEY FIELD ANGb mERIDIAN, mS

CONTRACTING OFFICER

186 ARW CONTRACTING OFFICE

mSGT NED mCCORmICk 6225 m STREET mERIDIAN, mS 39307 601-484-9860 NED.mCCORmICk.2@US.AF.mIL bASE CIVIL ENGINEER

186 CIVIL ENGINEER SQUADRON

LT. COL. VAUGHN THREATT

6225 m STREET mERIDIAN, mS 39307 601-484-9808 VAUGHN.THREATT@US.AF.mIL

NOTE: ALL REQUESTS FOR INFORmATION AND mATERIAL SUbmITTALS SHALL bE ROUTED THROUGH THE bASE CONTRACTING OFFICE.

PROJECT TEAm:

PROJECT SITE

45B

22nd AVE

N

EW

EL

L

R O

A D

8th ST

MERIDIAN

B O

U N D

S

RD

TH

A V

EN

U E

PO

PL

A R

14th ST

A V E th rd

A V E

S

PG

S

DR

NORTH HILLS ST

WINDMILL

DRIVE

LINDELY

ROAD

NE INDUST.

MARION

RD.PARK

PROJECT SITE

152151

807 808

505 506

303 501

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

TH

A

VE

HW

Y

M STREET

Building 308

BREAKROOM

SHEET INDEX

T-1 TITLE AND INDEX OF DRAWINGS

D-1 EXISTING CONDITIONS & DEmO PLAN

A-1 FLOOR PLAN & SCHEDULES

A-2 DETAILS SHEET

E-1 ELECTRICAL & LIGHTING PLAN

m-1 mECH/PLUmbING PLAN

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text T-1

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 186th AIR REFUELING WING

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text

04 AUG 2021

AutoCAD SHX Text o

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text l

AutoCAD SHX Text o

AutoCAD SHX Text o

AutoCAD SHX Text l

AutoCAD SHX Text p

AutoCAD SHX Text N

OVEN

R E F

EXISTING CABINET &

UTILITIES TO BE

REMOVED

EXISTING UTILITIES ON THIS WALL TO

BE MODIFIED/ REMOVED

EXISTING CABINET &

BAR TO BE REMOVED

EXISTING WALL

CABINET TO BE

REMOVED

EXISTING CONCRETE BLOCK

WALL TO BE REMOVED

(APPROX. 9' TALL)

ROOM 109

EXISTING OUTLETS/

COMM FIXTURES TO BE

RELOCATED/MODIFIED

ROOM 109A

16'-10"

14'-8"

EXISTING WOOD SHELVING

TO BE REMOVED

T

REMOVED BY GOV

EXISTING SINK &

FAUCET TO BE

REMOVED

REMOVED BY

GOV

REMOVED BY

GOV

EXISTING OUTLET

ABOVE COUNTERTOP

EXISTING

OUTLET TO BE

RELOCATED

SLAB DEMO FOR DRAIN

INSTALL - SEE SHT M-1

REMOVE DOOR, MAINTAIN

LOCKSET TO INSTALL ON

NEW DOOR

ROOM 109B

NIC

NIC

EXISTING CONDITIONS AND DEMOLITION PLAN

SCALE: 1/4" = 1'-0"

DEMOLITION NOTES

CONTRACTOR SHALL TAKE CARE NOT TO DAMAGE ANY FEATURES NOT INTENDED FOR DEMOLITION.

CONTRACTOR SHALL PREVENT TRASH FROM ESCAPING IMMEDIATE WORK AREA AND SHALL KEEP A CLEAN

AND ORDERLY CONSTRUCTION SITE.

ALL ITEMS NOT SPECIFICALLY MENTIONED FOR DEMOLITION BUT REQUIRED FOR CONSTRUCTION OF THE

IMPROVEMENTS FOR THIS PROJECT SHALL BE CONSIDERED INCIDENTAL.

CONTRACTOR SHALL PROTECT OR RESTORE ALL AREAS OUTSIDE THE SCOPE OF WORK FOR THIS PROJECT.

ELECTRICAL FEATURES (FIXTURES, RECEPTACLES) TO BE DEMOLISHED SHALL BE REMOVED ENTIRELY

(DEVICE, CABLING, CONDUIT,ETC.) BACK TO THE NEAREST JUNCTION BOX.

1.

2.

3.

4.

5.

LEGEND

DEMOLITION REQ'D

EXISTING CMU WALL

WATER FILTER

EXIST RECEPTACLE

EXIST DATA

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

SCALE: 1/4 = 1'-0"

0' 2'-0" 4'-0" 8'-0"

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 186th AIR REFUELING WING

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text D-1

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

04 AUG 2021

N

C

ROOM 109

4'-0"

5'-0"

9'X6' TABLE

(PROVIDED BY GOV)

9'X6' TABLE

(PROVIDED BY GOV)

3'-0"

COOLER

ICE

MAKER

DW

A-2

A

A-2

B

A-2

D

A-2

DISPLAY CASE BY GOV

R E F

CONSTRUCT HEADER OVER STRFRT

SEE DTL E, SHT A-2

ROOM 109B

NIC

NIC

COOLER

NEW LAT

EXIST CMU

1/2" GYPSUM BOARD

CHAIR RAIL CAP

APRON

PANEL MOULDING

PTD WOOD BASE

NEW LAT

EXIST CMU

BRICK VENEER

(WHERE EXPOSED)

PTD WOOD BASE

NEW LAT

EXIST CMU

" PTD GYP BOARD

(WHERE EXPOSED)

PTD WOOD BASE

FINISH SCHEDULE

ROOM NAME FLOOR AREA BASE

WALLS

CEILING CEILING HGT REMARKS

NORTH SOUTH EAST WEST

BREAKROOM (109)

VINYL PLANK 630 SF VINYL

GYP/SEE DTL

BRICK VENEER BRICK VENEER

GYP/SEE DTL

LAT 8'-6"

CLOSET (109B)

VINYL PLANK 32 SF VINYL PTD CMU PTD CMU PTD CMU PTD CMU LAT 8'-6"

DOOR SCHEDULE

TYPE WIDTH HEIGHT THK.

DOOR

MTL

FINISH FRM MATL FRM FIN

HARDWARE

SET

REMARKS

1 3'-0" 7'-0"

1 3/4"

SOLID

WOOD

CLEAR EXIST PTD NIC

2 3'-0" 7'-0"

1 3/4"

SOLID

WOOD

PTD EXIST PTD NIC

3 3'-0" 7'-0"

1 3/4"

ALUM

STRFT

BLACK

ALUM

STRFT

EXIST NIC

NOTES:

1. THESE DRAWINGS DO NOT INCLUDE ALL REQUIRED DETAILS, MATERIAL

REQUIREMENTS, CONNECTIONS, ETC. THE CONTRACTOR SHALL ENSURE

ALL INDUSTRY AND BASE STANDARDS ARE MET. ANY QUESTIONS

SHOULD BE SUBMITTED VIA EMAIL TO BASE CONTRACTING PRIOR TO

BIDDING.

2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO BIDDING.

3. ALL APPLIANCES WILL BE PROVIDED & INSTALLED BY GOV

FLOOR PLAN

SCALE: 1/4" = 1'-0"

FULL-LITE W/ FROSTED GLASS, EXISTING FRAME TO REMAIN & PAINT, RE-USE LOCKSET

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

SCALE: 1/4 = 1'-0"

0' 2'-0" 4'-0" 8'-0"

EXISTING FRAME & DOOR TO REMAIN & PAINT

REPLACE ALL GLAZING IN STORE FRONT W/ FROSTED GLASS TO MATCH DOOR 1

EXISTING WALLS ARE PTD CMU

EXISTING CEILING ARE 8'

WALL SECTION DETAIL

NTS

WALL SECTION DETAIL

NTS

WALL SECTION DETAIL

NTS

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 186th AIR REFUELING WING

AutoCAD SHX Text N

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text A-1

AutoCAD SHX Text 1/4" = 1'-0"

04 AUG 2021

ICE

MAKER

TV BY OTHERS

TV BY OTHERS

DISPLAY CASE

BY GOV

TV BY OTHERS

MODIFY EXISTING LAT EAST

OF DOOR TO TERMINATE

AT HEADER

HEADER BLOCKING

AS NECESSARY

EXISTING STOREFRONT FRAME

NEW LAT AT 8'6"

" PTD GYP

FLUSH HEADER GYP

WITH WALL GYP

" PTD GYP

SOUTH WALL ELEVATION

SCALE: 1/4" = 1'-0"

A-2

B

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

SCALE: 1/4 = 1'-0"

0' 2'-0" 4'-0" 8'-0"

EAST WALL ELEVATION

SCALE: 1/4" = 1'-0"

A-2

A

NORTH WALL ELEVATION

SCALE: 1/4" = 1'-0"

A-2

C

WEST WALL ELEVATION

SCALE: 1/4" = 1'-0"

A-2

D

HEADER DETAIL

SCALE: NTSA-2

E

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 186th AIR REFUELING WING

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text A-2

AutoCAD SHX Text 1/4" = 1'-0"

04 AUG 2021

DW

R E F

48" AFF (INSTALLED

ABOVE

COUNTERTOP)

LIGHT SWITCH FOR

UNDERCABINET

LIGHTING

48" AFF (INSTALLED

ABOVE COUNTERTOP)

RELOCATE

TO 48" AFF

(ABOVE

COUNTERTOP)

MODIFY TO 18" AFF

20A, 1Ø, 120V

DEDICATED

NEW OUTLET

INSTALLED BENEATH

THE COUNTERTOP

20A, 1Ø, 120V

DEDICATED

INSTALLED ABOVE

COUNTER TOP

COOLER

ICE

MAKER

INSTALL 20A, 1Ø, 120V

DEDICATED BENEATH

COUNTER FOR COOK TOP

INSTALL OUTLET IN

UPPER CABINETS FOR

EXHAUST VENT HOOD

REPLACE EXISTING LIGHT

CONTROLS W/ 3-WAY

TOGGLE DIMMER

REPLACE EXISTING LIGHT

CONTROLS W/ 3-WAY

TOGGLE DIMMER

COOLER

NOTES:

1. EXISTING 2X4 LAY-IN LIGHTS TO BE RE-USED. EXISTING 3-WAY SWITCHES SHALL BE REPLACED WITH

3-WAY TOGGLE DIMMERS.

2. AMPERAGE OF DEDICATED CIRCUITS SHOWN SHALL BE VERIFIED PRIOR TO INSTALLATION BASED ON

GOV'S SELECTED APPLIANCES.

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

DESCRIPTION VOLTS

WATTS/LAMPS

MANUFACTURER DESCRIPTION MOUNTING NOTES

2X4 LED TROFFER 120 ADJUSTABLE LITHONIA CPANEL 4K COLOR TEMP LAY-IN * RE-USE EXISTING FIXTURES*

RECESSED LIGHTING 120

18W/1500 LUMENS PER

FOOT

LITHONIA

(LDN 6 OR EQUAL)

6" COMMERICAL DOWN LIGHT RECESSED DIMMABLE

UNDER CABINET LIGHTING 120

18W/1500 LUMENS PER

FOOT

LITHONIA

(RAZ 6 OR EQUAL)

MODULAR UNDER CABINET

LIGHTING

SURFACE LENGTH AS SHOWN ± 12"

G

LEGEND

2'-0"x4'-0" LIGHT FIXTURE

HVAC SUPPLY

HVAC RETURN

LIGHT SWITCH (3-WAY, TOGGLE DIMMER)

OUTLET (EXISTING)

OUTLET (GFCI/NEW)

COMM BOX (EXISTING)

COMM BOX (NEW)

UNDERCABINET LIGHTING

S

ELECTRICAL PLAN

SCALE: 3/16" = 1'-0"

REFLECTING CEILING PLAN

SCALE:3/16" = 1'-0"

E

E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text E-1

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

04 AUG 2021

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

186th AIR REFUELING WING

DW

T

R E F

INSTALL WATER SERVICE FOR

REFRIGERATOR ICEMAKER W/

"T" VALVE FOR FUTURE

ADJACENT COFFEE MAKER

INSTALL

" SUPPLY & "T"

VALVE FOR DISHWASHER

EXISTING

" HOT WATER,

COLD WATER SUPPLY & 2"

DRAIN ALL FEEDING FROM

CHAISE TO SINK

INSTALL

" SUPPLY & "T"

VALVE FOR ICEMAKER

HW

CW

DRN

INSTALL FLOOR DRAIN AS

SPEC'D BY ICEMAKER MANUF. &

CONNECT TO DRAIN IN CHAISE

COOLER

ICE

MAKER

D-1

F-1

L-1

EF-1

SEE NOTE 1

EXISTING SUPPLY STRIP

DIFFUSERS TO BE REMOVED

COOLER

SCALE: 1/4 = 1'-0"

0' 2'-0" 4'-0" 8'-0"

MECH/PLUMBING PLAN

SCALE: 1/4" = 1'-0"

M:\Base Projects\SRM\MDVL212104 - Renovate Squad Ops Break Room Bldg 308\1.2 Work

Statement and Plans\renovate 308 working drawings

NOTES:

1. HVAC FIXTURES SHOWN IN APPROXIMATE EXISTING LOCATION. MODIFY AS NECESSARY FOR NEW CEILING. REPLACE ALL GRILLS

WITH NEW TO MATCH NEW CEILING FINISH. REPLACE EXISTING STRIP-STYLE SUPPLY DIFFUSERS WITH STANDARD 2'x2' GRILLES.

2. THESE DRAWINGS DO NOT INCLUDE ALL REQ'D. DETAILS, MATERIAL REQUIREMENTS, CONNECTIONS, ETC. THE CONTRACTOR SHALL

ENSURE ALL INDUSTRY AND BASE STANDARDS ARE MET. ANY QUESTIONS SHOULD BE SUBMITTED VIA EMAIL TO BASE

CONTRACTING PRIOR TO BIDDING.

3. CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO BIDDING.

T

LEGEND

THERMOSTAT

HVAC SUPPLY (EXIST)

HVAC SUPPLY (NEW)

HVAC RETURN

EXHAUST FAN

MARK MAKE MODEL DESCRIPTION REMARKS

EF-1 BROAN BCSD136SS

250 CFM (min) high-capacity ventilation hood with lights Stainless Steel, install ducted above ceiling

F-1 DELTA 978-DST

Single Handle Pull-Down Kitchen Faucet

CHROME

D-1 ZURN Z415-BZ1

Flush-mount, 6" drain with P-trap Stainless Steel top, include P-trap

L-1 KRAUS KA1US33B

Undermount, Stainless Steel Kitchen Sink

Min. 32"Wx19"Lx9"D

AutoCAD SHX Text N

AutoCAD SHX Text

BUILDING 308 - RENOVATION FOR BREAKROOM

AutoCAD SHX Text M-1

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

04 AUG 2021

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

186th AIR REFUELING WING

Sheets and Views
705plan-Model
VIEW1
PRIMARY
LATRINES
705plan-11X17
705plan-Layout1
renovate 308 working drawings-Model
VIEW1
PRIMARY
OLE1
renovate 308 working drawings-T-1
renovate 308 working drawings-D-1
renovate 308 working drawings-A-1
renovate 308 working drawings-A-2
renovate 308 working drawings-E-1
renovate 308 working drawings-M-1

File details come from the government source that posted it. Updated .