McIntosh_Park_Elements_Full_Set_02-19-26_SS_by_All.pdf
PDF 25 MB Posted
- Attached to
- McIntosh Park Wetland Construction
- Solicitation number
- 26-048UO-IFB
- Issued by
- Hillsborough County, Florida
About this file
This is a final design plans and specification document for the McIntosh Park Elements project in Plant City, Florida, prepared by Dewberry Engineers Inc. for the City of Plant City Utilities Department. The project encompasses the construction and restoration of wetlands across 363 acres at McIntosh Preserve, including stormwater treatment facilities, recreational amenities, and supporting infrastructure. The scope of work includes excavation and restoration of wetland areas with on-site soil stacking to create a 50-foot hill shaped like Florida, installation of reclaimed water pipe infrastructure with associated apparatus, construction of restroom and office facilities, a 30-foot by 64-foot pavilion, a 6-foot boardwalk with observation deck, 155 parking spaces plus 12 handicapped accessible spaces, and grading and drainage systems. The design incorporates two retention ponds (Pond R4 and Pond 200) with specific elevation requirements, stormwater management structures, sanitary sewer systems with septic tank and drainfield, a water well system tapping the Upper Floridan Aquifer with 50 GPM capacity, and electrical infrastructure including transformer installation and distribution panels. The project location is at 775 East Knights Griffin Road, Plant City, Florida 33565, with construction to comply with the most stringent requirements of Florida Department of Transportation standards and City of Plant City standards.
The project is partially funded through a State of Florida Department of Environmental Protection grant agreement (LPA0038), and all work must be conducted in accordance with grant terms and conditions. The design specifications require contractor coordination with the City of Plant City and the Engineer prior to commencing work, with particular emphasis on erosion and sediment control measures, tree protection within designated barricaded zones, and compliance with Southwest Florida Water Management District permits. The contractor is responsible for obtaining all necessary permits including NPDES Notice of Intent, dewatering permits, and coordinating with Sunshine State One Call (811) for underground utility identification at least two business days prior to excavation. Key professionals of record include Alba E. Mas, P.E. (Civil Engineer), Tracy Van Auken, P.E. (Electrical Engineer), and David S. Morris, P.E. (Structural Engineer), with the project manager identified as Lynn Spivey, Utilities Director. The document contains comprehensive civil, electrical, and structural drawing sheets with detailed specifications for construction materials, methods, and quality standards, including provisions for temporary erosion control, tree preservation, equipment protection, and final landscape stabilization.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RANGE 22E, TOWNSHIP 28S, SECTIONS 4,5,8,9
775 E KNIGHTS GRIFFIN ROAD, PLANT CITY, FL 33565
PARCEL ID # 089567-1000
LOCATION MAP
SCALE : 1"=1000'
N
PROJECT MANAGER :
LYNN SPIVEY
UTILITIES DIRECTOR
CITY OF PLANT CITY
1500 W VICTORIA STREET
PLANT CITY, FLORIDA, 33563
PHONE # (813) 757-9288
EMAIL: LSPIVEY@PLANTCITYGOV.COM
MCINTOSH PARK ELEMENTS
February 18, 2026
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
Know what's below.
Call before you dig.
CITY OF PLANT CITY, FLORIDA
UTILITIES DEPARTMENT
CITY COMMISSION
GROUP ONE : NATHAN A. KILTON, MAYOR
GROUP TWO : JASON JONES, VICE-MAYOR
GROUP THREE : WILLIAM D. DODSON
GROUP FOUR : MICHAEL S. SPARKMAN
GROUP FIVE : MARY THOMAS MATHIS
CITY MANAGER : BILL McDANIEL
UTILITIES DIRECTOR : LYNN SPIVEY
CIVIL ENGINEER OF RECORD:
ALBA E. MAS, P.E.
DEWBERRY ENGINEERS INC.
1479 TOWN CENTER DRIVE STE D214
LAKELAND, FL 33803
PHONE # (863) 345-1481
EMAIL: AMAS@DEWBERRY.COM
PROFESSIONAL LICENSE # 38617
CERTIFICATE OF AUTHORIZATION #: 8794
E KNIGHTS GRIFFIN ROAD
KNIGHTS GRIFFIN ROAD
N
ALEXAN
D
ER
ST
JOE MCINTOSH RD
MCLIN DR
U S 39
PAUL BUCHM
AN HW
Y
N
PROJECT
VICINITY
HILLSBOROUGH COUNTY, FLORIDA
LOCATION MAP
PLANT
CITY
LEGAL DESCRIPTION
THE NW 14 OF THE NW 14 LYING EAST OF CSX RAILROAD RIGHT-OF-WAY. THE NE 14 OF
THE NW 14, THE NW 14 OF THE NE 14, THE NE 14 OF THE NE 14, ALL LYING IN SECTION 8, TOWNSHIP 28 SOUTH, RANGE 22 EAST, HILLSBOROUGH COUNTY, FLORIDA.
AND THE NW 14 OF THE NW 14 OF SECTION 9, TOWNSHIP 28 SOUTH, RANGE 22 EAST,
HILLSBOROUGH COUNTY, FLORIDA LESS THAT PORTION LYING EAST OF CANAL. AND
THE SW 14 OF THE SW 14 LESS THAT PORTION LYING EAST OF CANAL, AND THE NW 14 OF
THE SW 14 LESS THE NORTH 375 FEET AND LESS THAT PORTION LYING EAST OF
CANAL, ALL IN SECTION 4, TOWNSHIP 28 SOUTH, RANGE 22 EAST, HILLSBOROUGH
COUNTY, FLORIDA. AND THE SE OF 14 OF THE SW 14, THE SW 14 OF THE SE 14, THE SE 14 OF
THE SE 14, THE NE 14 OF THE SE 14 LESS THE NORTH 375 FEET OF THE EAST 450 FEET,
AND THE SE 14 OF THE NE 14 LYING SOUTH OF KNIGHTS-GRIFFIN ROAD LESS THE EAST
450 FEET, ALL IN SECTION 5, TOWNSHIP 28TH SOUTH, RANGE 22 EAST,
HILLSBOROUGH COUNTY, FLORIDA.
SHEET INDEX
CIVIL DRAWINGS
C1.1 COVER SHEET
C1.2 SIGNATURE SHEET
C1.3 GENERAL NOTES AND LEGEND
C1.4 GENERAL NOTES AND LEGEND
C4.1 SURVEY CONTROL
C4.2 EXISTING CONDITIONS
C4.3 OVERALL SITE PLAN
C4.4 PARKING AREA DIMENSION PLAN
C4.5 PARKING AREA DIMENSION PLAN
C4.6 PAVILION PLAN
C4.7 BOARDWALK PLAN
C4.8 PARKING AREA GRADING & DRAINAGE PLAN
C4.9 PARKING AREA GRADING & DRAINAGE PLAN
C4.10 PAVILION GRADING PLAN
C4.11 BOARDWALK PLAN & PROFILE
C4.12 WATER & SEWER PLAN
C5.1 CIVIL DETAILS
C5.2 OFFICE/BATHROOM PLAN & ELEVATIONS
C5.3 PAVILION PLAN AND ELEVATIONS
C5.4 SANITARY SEWER DETAILS
C5.5 WATER DETAILS
ELECTRICAL DRAWINGS
E-01 LEGEND, ABBREVIATIONS, AND GENERAL NOTES
E-02 OVERALL SITE PLAN
E-03 ENLARGED PLAN
E-04 SCHEDULES AND SINGLE LINE
E-05 DETAILS
STRUCTURAL DRAWINGS
S1.1 GENERAL STRUCTURAL NOTES AND SCHEDULE
S1.2 STRUCTURAL NOTES & SITE IMPROVEMENTS KEY PLAN
S5.1 BOARDWALK FRAMING DETAILS 1 OF 2
S5.2 BOARDWALK FRAMING DETAILS 2 OF 2
S5.3 PLATFORM PLAN AND SECTION
S5.4 RESTROOM KEY PLAN, FOUNDATION PLAN AND DETAILS
S5.5 RESTROOM BUILDING DATA AND SCHEDULES
S5.6 PAVILION PLAN & DETAIL
S5.7 TYPICAL STRUCTURAL DETAILS
PROJECT
LOCATION
ELECTRICAL ENGINEER OF RECORD:
TRACY VAN AUKEN, P.E.
DEWBERRY ENGINEERS INC.
2610 WYCLIFF ROAD, SUITE 410
RALEIGH N.C. 27607-3073
PHONE # (919) 424-3766
EMAIL: TVANAUKEN@DEWBERRY.COM
PROFESSIONAL LICENSE # 97129
CERTIFICATE OF AUTHORIZATION #: 8794
STRUCTURAL ENGINEER OF RECORD:
DAVID S. MORRIS, P.E.
WEKIVA ENGINEERING
1320 WILFRED DRIVE
PHONE # (407) 219-4454
EMAIL: DAVID@WEKIVAENGINEERING.COM
PROFESSIONAL LICENSE # 74717
CERTIFICATE OF AUTHORIZATION #: 31920
CIVIL SHEETS
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
February 18, 2026
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
C1.2 X
SIGNATURE
SHEET
ELECTRICAL SHEETS STRUCTURAL SHEETS
S1.1 GENERAL STRUCTURAL NOTES AND SCHEDULE
S1.2 STRUCTURAL NOTES & SITE IMPROVEMENTS KEY PLAN
S5.1 BOARDWALK FRAMING DETAILS 1 OF 2
S5.2 BOARDWALK FRAMING DETAILS 2 OF 2
S5.3 PLATFORM PLAN AND SECTION
S5.4 RESTROOM KEY PLAN, FOUNDATION PLAN AND DETAILS
S5.5 RESTROOM BUILDING DATA AND SCHEDULES
S5.6 PAVILION PLAN & DETAIL
S5.7 TYPICAL STRUCTURAL DETAILS
C1.1 COVER SHEET
C1.2 SIGNATURE SHEET
C1.3 GENERAL NOTES AND LEGEND
C1.4 GENERAL NOTES AND LEGEND
C4.1 SURVEY CONTROL
C4.2 EXISTING CONDITIONS
C4.3 OVERALL SITE PLAN
C4.4 PARKING AREA DIMENSION PLAN
C4.5 PARKING AREA DIMENSION PLAN
C4.6 PAVILION PLAN
C4.7 BOARDWALK PLAN
C4.8 PARKING AREA GRADING & DRAINAGE PLAN
C4.9 PARKING AREA GRADING & DRAINAGE PLAN
C4.10 PAVILION GRADING PLAN
C4.11 BOARDWALK PLAN & PROFILE
C4.12 WATER & SEWER PLAN
C5.1 CIVIL DETAILS
C5.2 OFFICE/BATHROOM PLAN & ELEVATIONS
C5.3 PAVILION PLAN AND ELEVATIONS
C5.4 SANITARY SEWER DETAILS
C5.5 WATER DETAILS
E-01 LEGEND, ABBREVIATIONS, AND GENERAL NOTES
E-02 OVERALL SITE PLAN
E-03 ENLARGED PLAN
E-04 SCHEDULES AND SINGLE LINE
E-05 DETAILS
D
A
V
I
D
S
. M
O
R
R
I
S
P
R
O
F
E
S
S
I
O
N A
L
E
N
G
I
N
E
E
R
L
I
C
E N
S
E
F
L
O
R I
D
A
No. 74717
STATE OF
Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
/0
4/
:4 0:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
.D W
G
C1.3 X
GENERAL NOTES:
1. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE ENGINEER AND THE CITY OF PLANT CITY PRIOR TO COMMENCING.
2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH AND CONFORM TO THE MOST STRINGENT REQUIREMENTS OF THE PROJECT SPECIFICATIONS, THE LATEST EDITION UNLESS EARLIER DATE IS SPECIFIED FOR SPECIFIC ITEM OF THE FLORIDA DEPARTMENT OF TRANSPORTATION'S STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (F.D.O.T.) AND THE CITY OF PLANT CITY STANDARDS.
3. ALL DIMENSIONS AND ELEVATIONS ARE BASED ON THE BEST INFORMATION AVAILABLE. TRUE DIMENSIONS AND ELEVATIONS SHALL BE DETERMINED IN THE
FIELD BY THE CONTRACTOR PRIOR TO LAYOUT AND SHOP DRAWING SUBMITTALS.
4. INFORMATION REGARDING EXISTING CONDITIONS PROVIDED IN THESE DRAWINGS IS GIVEN SOLELY TO ASSIST THE CONTRACTOR IN ADDRESSING THE NATURE AND EXTENT OF CONDITIONS WHICH MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL CONTRACTORS ARE DIRECTED TO CONDUCT WHATEVER INVESTIGATIONS THEY MAY DEEM NECESSARY, PRIOR TO BIDDING, SO THAT THEY MAY ARRIVE AT THEIR OWN CONCLUSIONS REGARDING THE ACTUAL CONDITIONS THAT WILL BE ENCOUNTERED AND UPON WHICH THEIR BIDS WILL BE BASED. ACCESS TO THE FACILITY MUST BE COORDINATED WITH
THE CITY OF PLANT CITY, PRIOR TO ANY PROPOSED INVESTIGATIONS.
5. CONTRACTOR SHALL VERIFY ALL EXISTING GRADES ON SITE BEFORE BEGINNING WORK. THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY OF ANY MAJOR DIFFERENCES BETWEEN CONTRACTOR'S DATA AND DRAWINGS. EXISTING CULVERT AT ENTRY ROAD FROM E. KNIGHTS GRIFFIN RD, NOT
IDENTIFIED IN SURVEY, TO BE PROTECTED AND MAINTAINED IN GOOD CONDITION.
6. EXISTING GRADES SHALL BE MAINTAINED UNLESS OTHERWISE INDICATED ON DRAWINGS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A DEWATERING PERMIT FROM THE SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT AS
REQUIRED, IF NECESSARY.
8. CONTRACTOR SHALL COMPLY WITH ALL PERMIT CONDITIONS DURING CONSTRUCTION.
9. ALL WORK SHALL BE OPEN TO AND SUBJECT TO INSPECTION BY AUTHORIZED PERSONNEL OF LOCAL, STATE, AND FEDERAL REGULATORY AGENCIES, UTILITY COMPANIES, AND THE OWNER'S REPRESENTATIVE.
10. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS CONTAINED HEREIN AND/OR OTHERWISE REQUIRED BY APPLICABLE FEDERAL, STATE AND LOCAL CODES, ORDINANCES, AND REGULATIONS, IN THE EVENT OF A CONFLICT BETWEEN THE REQUIREMENTS, THE
MOST STRINGENT SHALL APPLY AS DETERMINED BY THE OWNER'S REPRESENTATIVE.
11. THE CONSTRUCTION SITE SHALL BE MAINTAINED IN AS NEAT AND ORDERLY CONDITION AS POSSIBLE DURING CONSTRUCTION OPERATIONS. CONTRACTOR SHALL SECURE ANY TEMPORARY EQUIPMENT/MATERIAL LAYOUT AREA WITH TEMPORARY PERIMETER SECURITY FENCES, WITH PRIVACY CANVAS, OF AT
LEAST 6 FT. HIGH.
12. CONTRACTOR SHALL RESTORE ANY EXISTING LANDSCAPING OR FEATURES THAT MAY HAVE BEEN DAMAGED DURING CONSTRUCTION TO ITS ORIGINAL
CONDITION OR BETTER.
13. CONTRACTOR TO OBTAIN AN NPDES NDPES NOTICE OF INTENT.
14. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING FEES.
15. STANDARD INDEXES REFER TO THE LATEST EDITION OF FDOT "STANDARD PLANS."
16. ALL MITERED END SECTIONS (M.E.S.) SHALL BE FDOT STD INDEX 430-021.
17. ALL RIPRAP TO BE "DITCH LINING" WITH TYPE D-2 GEOTEXTILE FABRIC PER (SEE BACK OF SHEET).
18. AT A MINIMUM, ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED WITH EITHER SOD OR SEED/MULCH, SOD OR SEED AREAS SHALL BE WATERED BY EITHER IRRIGATION OR TANKER TRUCKS UNTIL ESTABLISHED; SOD SHALL BE MONITORED FOR WASHOUTS. SEEDED AREAS MUST BE WATERED AS NECESSARY TO ALLOW GRASS TO BEGIN GROWING. HYDROSEEDING (IN LIEU OF SOD) IS ALLOWED TO AREAS FLATTER THAN 5:1 SLOPES WITH
PRIOR APPROVAL FROM ENGINEER.
19. CONTRACTOR SHALL OBTAIN THE LATEST EDITION OF THE SOIL REPORT FOR THIS PROJECT. THE GENERAL CONTRACTORS SHALL ADHERE TO ALL
RECOMMENDATIONS AND INSTRUCTIONS INCLUDED IN SOIL REPORT.
20. A COPY OF THE APPROVED PERMITS AND DRAWINGS MUST BE ON THE JOBSITE AT ALL TIMES.
21. ALL PIPE JOINTS TO BE WRAPPED WITH FILTER FABRIC JACKET PER FDOT STD INDEX 430-001.
TREE PROTECTION NOTES (WITHIN DESIGNATED TREE BARRICADED PROTECTION
ZONES AS ILLUSTRATED ON THE PLANS):
1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL TREES WITHIN THE VICINITY OF THE PROPOSED CONSTRUCTION IN ACCORDANCE WITH
APPLICABLE CODES AND STANDARDS. PRUNING OF BRANCHES IS NOT AUTHORIZED WITHOUT PRIOR APPROVAL FROM PLANT CITY PARKS AND RECREATION
DEPARTMENT, AND SHALL BE COMPLETED BY A CERTIFIED ARBORIST.
2. THE COST FOR TREE PROTECTION SHALL BE INCLUDED IN THE PROJECT COSTS.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UNAUTHORIZED CUTTING OR DAMAGE TO ANY EXISTING TREES OR SHRUBS CAUSED BY CARELESS
OPERATION OF EQUIPMENT, STOCKPILING OF MATERIALS, ETC.
4. AVOID SCRAPING LOWER LIMBS OR GOUGING BARK OF TREES BY HEAVY EQUIPMENT OR CONSTRUCTION MATERIALS. INSTALL BARRICADES OR WRAP TREE
TRUNKS AS NEEDED.
EROSION CONTROL NOTES:
1. ALL EROSION AND SEDIMENT CONTROL WORK SHALL CONFORM TO THE STANDARDS OF PLANT CITY, FLORIDA, AND THE SOUTHWEST FLORIDA WATER
MANAGEMENT DISTRICT.
2. EROSION AND SEDIMENT CONTROL, TREE BARRICADE AND TURBIDITY BARRIERS SHOWN OF CIVIL SHEETS.
3. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO, OR AS THE FIRST STEP IN, CONSTRUCTION. SEDIMENT CONTROL PRACTICES WILL BE APPLIED AS A PERIMETER DEFENSE AGAINST ANY TRANSPORTATION OF SOIL OFF THE SITE. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTICE
TO THE ENGINEER AND THE AGENCIES 10 DAYS PRIOR TO COMMENCING WORK.
4. AT A MINIMUM, SILT BARRIERS SHALL BE PLACED AS SHOWN ON CONSTRUCTION DRAWINGS TO INSURE AGAINST POLLUTING, SILTING OR DISTURBING TO SUCH AN EXTENT AS TO CAUSE AN INCREASE IN TURBIDITY TO THE ADJACENT EXISTING PROPERTY AND/OR WETLAND/CONSERVATION AREAS. IF DURING CONSTRUCTION THE PROPOSED EROSION CONTROL SYSTEM DOES NOT PERFORM SATISFACTORILY, ALTERNATIVES AND ADDITIONAL MEASURES SHALL BE IMPLEMENTED BY THE CONTRACTOR IN ORDER TO COMPLY WITH PLANT CITY AND SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT EROSION
PROTECTION STANDARDS.
5. CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR ALL EROSION PROTECTION COSTS INCLUDING ANY COSTS ASSOCIATED WITH COMPLIANCE ISSUES AND
ENFORCEMENT ACTIONS.
6. PROVIDE FILTER FABRIC UNDER THE GRATE OF ALL INLETS AFTER INITIAL COMPLETION OF THE DRAINAGE STRUCTURES. MAINTAIN THESE MEASURES DAILY (WHICH MAY INCLUDE FULL REPLACEMENT AT THE DISCRETION OF THE OWNER) TO MINIMIZE SILT ACCUMULATION IN THE STORM DRAINAGE SYSTEM
DURING CONSTRUCTION.
7. ALL DISTURBED AREAS TO BE PLANTED PER PLANTING PLAN OR STABILIZED WITH SOD OR SEED/MULCH.
GENERAL NOTES AND
LEGEND
SURVEY NOTES:
1. ALL ELEVATIONS IN THESE PLANS ARE BASED ON NAVD 1988. ALL HORIZONTAL COORDINATES ARE IN US SURVEY FEET AND REFLECT A PROJECTION OF GRID COORDINATES IN THE STATE PLANE COORDINATE SYSTEM, FLORIDA WEST ZONE, NAD 1983.
2. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL SURVEY MONUMENTS ON THE PROJECT PARCEL. THE CONTRACTOR IS RESPONSIBLE FOR CONTRACTING WITH A SURVEYOR LICENSED IN THE STATE OF FLORIDA TO REPLACE ANY DAMAGED SURVEY MONUMENTS.
3. EXISTING SURVEY INFORMATION IS BASED ON A BOUNDARY, TOPOGRAPHIC & TREE SURVEY PROVIDED BY SURVTECH SOLUTIONS, INC.
4. CONTRACTOR TO VERIFY GATE HEIGHT AT E KNIGHTS RD ENTRANCE TO ENSURE EQUIPMENT ACCESSIBILITY. HEIGHT APPROXIMATELY 14 FEET.
PAVING, GRADING & DRAINAGE
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (FDEP)
FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT)
AMERICANS WITH DISABILITIES ACT (ADA) BY U.S. DEPARTMENT OF JUSTICE
"MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD) PUBLISHED BY THE U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL
HIGHWAY ADMINISTRATION
22. UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION SHALL BE PERFORMED CONSISTENT WITH THE MOST RECENT PUBLICATION OF THE FOLLOWING CODES, STANDARDS AND SPECIFICATIONS AS WELL AS THE LATEST EDITIONS OF ALL OTHER APPLICABLE SPECIFICATIONS & STANDARDS:
25. GEOTECHNICAL RECOMMENDATIONS OR RECOMMENDATIONS AS PROVIDED IN SUPPLEMENTAL REPORTS BY OTHERS ARE NOT THE RESPONSIBILITY OF DEWBERRY INC., WHO HAS RELIED UPON THE REFERENCED GEOTECHNICAL REPORT(S) IN THE PREPARATION OF THE PLANS. ANY CONFLICT BETWEEN INFORMATION CONTAINED IN THE REPORT(S) AND THESE PLANS SHALL BE REPORTED TO THE ENGINEER AND OWNER IMMEDIATELY AND IN WRITING.
DEWBERRY INC. ASSUMES NO RESPONSIBILITY FOR THE CORRECTNESS, COMPLETENESS, OR ACCURACY OF THE REPORT(S). WHEN THE PLANS AND/OR SPECIFICATIONS CONTAIN THE RESULTS OF A SOILS SURVEY, THE CONTRACTOR SHALL NOT ASSUME THE INFORMATION IS A GUARANTEE OF THE DEPTH, EXTENT OR CHARACTER OF MATERIAL PRESENT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE A NECESSARY EXAMINATION OF THE SITE AND OF ANY MATERIAL SOURCES INDICATED ON THE PLANS TO BE INFORMED OF THE CONDITIONS UNDER WHICH CONSTRUCTION IS TO OCCUR.
26. THE CONTRACTOR SHALL OBTAIN FROM THE OWNER COPIES OF PERMITS FOR ALL AGENCIES HAVING JURISDICTION, SUCH AS GOVERNMENTAL, REGULATORY OR LOCAL ENTITIES. THE CONTRACTOR SHALL BE EXPECTED TO REVIEW AND ABIDE BY ALL THE TERMS, CONDITIONS, REQUIREMENTS AND LIMITATIONS SET FORTH IN ALL OF THESE PERMITS. A COPY OF THE PERMITS SHALL BE KEPT ON THE CONSTRUCTION SITE AND MADE AVAILABLE FOR
REVIEW AT ALL TIMES.
27. IF ITEMS APPEARING TO BE HISTORICAL OR ARCHEOLOGICAL ARTIFACTS ARE DISCOVERED AT ANY TIME DURING CONSTRUCTION WITHIN THE PROJECT LIMITS, IMMEDIATE NOTIFICATION SHALL BE PROVIDED TO THE OWNER, THE ENGINEER, AND THE BUREAU OF HISTORICAL PRESERVATION, DIVISION OF HISTORICAL RESOURCES R.A. GRAY BUILDING, 500 S. BRONOUGH ST. TALLAHASSEE, FLORIDA 32399-0250.
23. ALL ELEVATIONS SHOWN ON THESE DRAWINGS REFER TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).
24. THESE PLANS WERE BASED ON THE GEOTECHNICAL REPORT(S) BY TIERRA, JOSEPH R ANTINORI, P.E./FL. REG NO. 73176, PHONE: 813-989-1254. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACQUIRE A COPY OF THE REPORT(S) FROM THE GEOTECHNICAL ENGINEER, FAMILIARIZE THEMSELVES WITH THE CONDITIONS AS DESCRIBED IN THE REPORT(S), AND COMPLY WITH ALL RECOMMENDATIONS MADE IN THE REPORT(S) SPECIFICALLY FOR SOIL PREPARATION ON THE SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN A COPY OF ALL SUPPLEMENTAL REPORTS FOR THIS PROJECT FROM THE
OWNER AND TO FOLLOW THE SUPPLEMENTAL REPORTS' RECOMMENDATIONS.
CITY OF PLANT CITY
SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD)
1. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE SITE, INCLUDING ALL SURFACE AND SUBSURFACE CONDITIONS, THE WORK REQUIRED AND ALL OTHER CONDITIONS THAT MAY EFFECT THE SUCCESSFUL COMPLETION OF THE JOB PRIOR TO COMMENCEMENT OF WORK.
2. THE LOCATIONS OF EXISTING UTILITY SERVICES, FACILITIES, AND STRUCTURAL FEATURES SHOWN ON THESE PLANS HAVE BEEN DETERMINED FROM THE BEST AVAILABLE INFORMATION AND ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OR THE COMPLETENESS OF THE LOCATION INFORMATION PROVIDED. ANY INACCURACY OR OMISSION IN SUCH INFORMATION SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO PROTECT THE EXISTING FEATURES FROM DAMAGE OR UNSCHEDULED INTERRUPTION OF SERVICE. SHOULD A DISCREPANCY ARISE BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS, WHICH WOULD APPRECIABLY AFFECT THE EXECUTION OF THESE PLANS, THE
CONTRACTOR SHALL STOP ALL CONSTRUCTION AND NOTIFY THE ENGINEER IMMEDIATELY.
3. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND PERMIT CONDITIONS BEARING ON THE CONDUCT OF THE WORK, AS DRAWN AND SPECIFIED. IF THE CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT VARIANCE THEREWITH, HE SHALL PROMPTLY NOTIFY THE ENGINEER, IN WRITING, AND ANY NECESSARY CHANGES SHALL BE ADJUSTED, AS PROVIDED IN THE
AGREEMENT FOR CHANGES IN THE WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL FACILITIES UNTIL THE PROJECT HAS BEEN ACCEPTED BY THE OWNER. ALL
DISTURBED AREAS SHALL BE RETURNED TO EQUAL OR BETTER CONDITION.
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO THE OWNER AND THE ENGINEER FOR THE ACTS AND OMISSIONS OF CONTRACTOR'S EMPLOYEES AND ALL HIS SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES AND OTHER PERSONS PERFORMING ANY OF THE WORK UNDER A CONTRACT WITH THE
CONTRACTOR.
6. ALL WORK AND FURNISHED MATERIALS SHALL BE IN REASONABLE CONFORMITY WITH THE LINES, GRADES, GRADING SECTIONS, CROSS SECTIONS, DIMENSIONS, MATERIAL REQUIREMENTS AND TESTING REQUIREMENTS THAT ARE SPECIFIED IN THE CONTRACT, PLANS, DETAILS OR SPECIFICATIONS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL NECESSARY ARRANGEMENTS WITH GOVERNMENTAL DEPARTMENTS, PUBLIC UTILITIES, PUBLIC CARRIERS, SERVICE COMPANIES, AND CORPORATIONS OWNING OR CONTROLLING ROADWAYS, RAILWAYS, WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, AND TELEGRAPH FACILITIES SUCH AS PAVEMENTS, TRACKS, PIPING, WIRES, CABLES, CONDUITS, POLES, GUYS, OR OTHER SIMILAR FACILITIES, INCLUDING INCIDENTAL STRUCTURES CONNECTED THEREWITH THAT ARE ENCOUNTERED IN THE WORK IN ORDER THAT SUCH ITEMS MAY BE PROPERLY SUPPORTED, PROTECTED OR LOCATED.
8. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL BARRICADES, LIGHTS, WARNING SIGNS, AND PAVEMENT MARKINGS FOR HAZARDS AND THE CONTROL OF TRAFFIC THROUGH THE CONSTRUCTION ZONE IN CONFORMITY WITH THE ALL AGENCIES HAVING JURISDICTION STANDARDS TO EFFECTIVELY PREVENT ACCIDENTS AT ALL LOCATIONS WHERE CONSTRUCTION CAUSES AN OBSTRUCTION TO THE NORMAL
FLOW OF TRAFFIC OR CREATES A HAZARD IN ANY WAY TO THE PUBLIC.
9. IN THE EVENT THE CONTRACTOR DISCOVERS ANY ERRORS OR OMISSIONS IN THE PLANS HE SHALL IMMEDIATELY NOTIFY THE OWNER OR OWNER'S AGENT.
10. THE CONTRACTOR SHALL COMPLY WITH ALL LEGAL LOAD RESTRICTIONS IN THE HAULING OF MATERIALS ON PUBLIC ROADS BEYOND THE LIMITS OF THE WORK. A SPECIAL PERMIT WILL NOT RELIEVE THE CONTRACTOR OF LIABILITY FOR ANY DAMAGE THAT MAY RESULT FROM THE MOVING OF MATERIALS AND
EQUIPMENT.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SURVEY MONUMENTATION, SUCH AS THE PRESERVATION OF ALL PERMANENT REFERENCE MONUMENTS, PERMANENT CONTROL POINTS, PERMANENT BENCH MARKS, PROPERTY CORNERS, POINTS OR MARKERS. IN THE EVENT ANY MONUMENTATION IS DISTURBED, IT SHALL BE RESTORED BY A FLORIDA LICENSED SURVEYOR AND MAPPER SELECTED BY THE OWNER AT THE
CONTRACTOR'S EXPENSE.
12. THE OWNER, OWNER'S REPRESENTATIVES AND INSPECTORS OF APPLICABLE GOVERNMENT AGENCIES HAVING JURISDICTION, SHALL AT ALL TIMES HAVE ACCESS TO THE WORK SITE WHEREVER AND WHENEVER IT IS IN PREPARATION OR PROGRESS. THE CONTRACTOR SHALL PROVIDE PROPER FACILITIES FOR
SUCH ACCESS AND INSPECTIONS.
13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO TAKE ALL REASONABLE AND PRUDENT PRECAUTIONS TO INSURE THAT ALL COMPLETED WORK, MATERIALS AND EQUIPMENT STORED ON SITE ARE SAFE AND SECURED FROM UNAUTHORIZED ACCESS OR USE. SUCH PRECAUTIONS MAY INCLUDE INSTALLATION OF SIGNS, FENCES, OR POSTING OF SECURITY GUARDS.
14. CONTRACTOR SHALL, AT ALL TIMES, UTILIZE ALL NORMALLY ACCEPTED AND REASONABLY EXPECTED SAFETY PRACTICES AND COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS, ORDINANCES AND GUIDELINES PERTAINING TO SAFE UTILIZATION OF EQUIPMENT OR MATERIALS AS PUBLISHED BY
MANUFACTURER.
15. ADEQUATE TRAFFIC CONTROL, SIGNAGE, BARRICADES AND FLAGMAN SERVICES SHALL BE FURNISHED AND MAINTAINED BY THE CONTRACTOR AT ALL POINTS WHERE CONSTRUCTION EQUIPMENT ENGAGED IN WORK ENTERS ONTO OR CROSSES FUNCTIONING TRAFFIC-CARRYING ROADWAY.
16. THOSE PARTS OF WORK IN PLACE THAT ARE SUBJECT TO DAMAGE BECAUSE OF OPERATIONS BEING CARRIED ON ADJACENT THERETO SHALL BE COVERED, BOARDED UP OR SUBSTANTIALLY ENCLOSED WITH ADEQUATE PROTECTION BY THE CONTRACTOR AT CONTRACTOR'S EXPENSE, PROTECTING WORK
COMPLETED.
17. THE CONTRACTOR SHALL COMPLY IN EVERY RESPECT WITH THE FEDERAL OCCUPATIONAL HEALTH AND SAFETY ACT OF 1970 AND ALL RULES AND REGULATIONS NOW OR HEREAFTER IN EFFECT UNDER SAID ACT, AND THE CONTRACTOR FURTHER AGREES TO COMPLY WITH ANY AND ALL APPLICABLE
STATE LAWS AND REGULATIONS PERTAINING TO JOB SAFETY AND HEALTH.
18. THE CONTRACTOR SHALL PROTECT AND KEEP OWNER (INCLUDING THEIR AGENTS AND EMPLOYEES) FREE AND HARMLESS FROM ANY AND ALL LIABILITY, PUBLIC OR PRIVATE, PENALTIES, CONTRACTUAL OR OTHERWISE, LOSSES, DAMAGES, COSTS, ATTORNEY'S FEES, EXPENSES, CAUSES OF ACTION, CLAIMS OR JUDGMENTS RESULTING FROM THE FEDERAL OCCUPATIONAL HEALTH AND SAFETY ACT OF 1970 AS AMENDED OR ANY RULE OR REGULATION PROMULGATED THEREUNDER OR OF ANY STATE LAWS OR REGULATIONS PERTAINING TO JOB SAFETY AND HEALTH ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE PERFORMANCE OF WORK OR WORK TO BE PERFORMED UNDER THIS CONTRACT, AND CONTRACTOR SHALL INDEMNIFY OWNER FROM ANY SUCH CLAIMS, PENALTIES, SUITS OR ACTIONS, PUBLIC OR PRIVATE, ADMINISTRATIVE OR JUDICIAL, INCLUDING ATTORNEY'S FEES PAID OR INCURRED BY OR ON BEHALF OF OWNER, JOINTLY OR SEVERALLY, AND/OR THEIR AGENTS AND EMPLOYEES. THE CONTRACTOR FURTHER AGREES, IN THE EVENT OF A CLAIMED VIOLATION OF ANY FEDERAL OR STATE SAFETY AND HEALTH LAW OR REGULATION ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE PERFORMANCE OF WORK OR WORK TO BE PERFORMED UNDER THIS CONTRACT, OWNER MAY IMMEDIATELY TAKE WHATEVER ACTION IS DEEMED NECESSARY BY OWNER TO REMEDY THE CLAIMED VIOLATION. ANY AND ALL COSTS OR EXPENSES PAID OR INCURRED BY OWNER IN TAKING SUCH ACTION SHALL BE BORNE BY CONTRACTOR, AND CONTRACTOR AGREES TO PROTECT, HOLD HARMLESS AND INDEMNIFY OWNER AGAINST ANY AND ALL SUCH COSTS OR EXPENSES.
19. THE CONTRACTOR SHALL TAKE ALL REASONABLE PRECAUTIONS FOR THE SAFETY OF, AND SHALL PROVIDE ALL REASONABLE PROTECTION TO PREVENT
DAMAGE, INJURY OR LOSS TO:
A. ALL EMPLOYEES ON THE WORK SITE AND ALL OTHER PERSONS WHO MAY BE AFFECTED THEREBY;
B. ALL THE WORK AND ALL MATERIALS AND EQUIPMENT TO BE INCORPORATED THEREIN, WHETHER IN STORAGE ON OR OFF THE SITE, UNDER THE
CARE, CUSTODY OR CONTROL OF THE CONTRACTOR OR ANY OF ITS SUBCONTRACTORS; AND
C. OTHER PROPERTY AT THE SITE OR ADJACENT THERETO, INCLUDING TREES, SHRUBS, LAWNS, WALKS, PAVEMENTS, ROADWAY, STRUCTURES AND
UTILITIES NOT DESIGNATED FOR DEMOLITION IN THE COURSE OF CONSTRUCTION.
20. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SAFETY CODES AND WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC, QUASI PUBLIC OR OTHER AUTHORITY HAVING JURISDICTION FOR THE SAFETY OF PERSONS OR PROPERTY OR FOR THEIR PROTECTION AGAINST DAMAGE, INJURY OR LOSS, OR DESIGNED TO PROTECT THE ENVIRONMENT. THE CONTRACTOR SHALL ERECT AND MAINTAIN, AS REQUIRED BY EXISTING CONDITIONS AND PROGRESS OF THE WORK, ALL REASONABLE SAFEGUARDS FOR SAFETY AND PROTECTION, INCLUDING POSTING DANGER SIGNS AND OTHER WARNINGS AGAINST HAZARDS, PROMULGATING SAFETY REGULATIONS AND NOTIFYING OWNERS AND USERS OF ADJACENT
UTILITIES OF THE EXISTENCE OF HAZARDS AND OF THE SAFETY REGULATIONS.
21. `ALL DAMAGE OR LOSS TO ANY PROPERTY REFERRED TO HEREIN CAUSED IN WHOLE OR IN PART BY THE CONTRACTOR, A SUBCONTRACTOR, OR BY ANYONE FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE, SHALL BE REMEDIED BY THE CONTRACTOR, EXCEPT DAMAGE OR LOSS PROPERLY ATTRIBUTABLE SOLELY TO THE ACTS OR OMISSIONS OF THE OWNER, OR THE ENGINEER OR ANYONE EMPLOYED BY THEM, OR FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE, AND NOT PROPERLY ATTRIBUTABLE IN WHOLE OR IN PART, TO THE FAULT OR NEGLIGENCE OF THE CONTRACTOR.
22. UNTIL FINAL ACCEPTANCE OF THE WORK BY OWNER, THE CONTRACTOR SHALL HAVE THE CHARGE AND CARE OF AND SHALL BEAR THE RISK OF INJURY OR DAMAGE, LOSS OR EXPENSE TO ANY PART THEREOF, OR TO ANY MATERIALS STORED ON SITE, BY THE ACTION OF THE ELEMENTS OR FROM ANY OTHER CAUSE WHETHER ARISING FROM THE EXECUTION OR NON-EXECUTION OF THE WORK. THE CONTRACTOR SHALL REBUILD, REPAIR, RESTORE AND MAKE GOOD ALL INJURIES OR DAMAGES TO ANY PORTION OF THE WORK OCCASIONED BY ANY OF THE ABOVE CAUSES BEFORE FINAL ACCEPTANCE AND SHALL
BEAR THE EXPENSES THEREOF.
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING ALL INSPECTION CRITERIA AND SCHEDULES, AND SIGNING FOR SAID INSPECTIONS.
24. THE CONTRACTOR SHALL CONTROL AND BE RESPONSIBLE FOR THEIR OPERATIONS AND THOSE OF THEIR SUBCONTRACTORS AND ALL SUPPLIERS, TO ASSURE THE LEAST INCONVENIENCE TO THE PUBLIC. THE CONTRACTOR SHALL MAINTAIN FREE AND UNOBSTRUCTED MOVEMENT OF VEHICULAR TRAFFIC AND SHALL LIMIT THEIR OPERATIONS IN RELATION TO THE SAFETY AND CONVENIENCE OF THE TRAVELING PUBLIC. UNDER ALL CIRCUMSTANCES, SAFETY
SHALL BE THE MOST IMPORTANT CONSIDERATION.
25. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE POLICIES AND GUIDELINES ESTABLISHED BY ALL AGENCIES HAVING JURISDICTION FOR THE PRESERVATION OF ALL PUBLIC AND PRIVATE PROPERTY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE OR INJURY TO PROPERTY OF ANY CHARACTER, DURING THE EXECUTION OF THE WORK, RESULTING FROM ANY ACT, OMISSION, NEGLECT, OR MISCONDUCT IN THEIR MANNER OR METHOD OF
EXECUTING THE WORK, OR AT ANYTIME DUE TO DEFECTIVE WORK OR MATERIALS.
26. THE CONTRACTOR SHALL NOT EXCAVATE, REMOVE, OR OTHERWISE DISTURB ANY MATERIAL, STRUCTURE OR PART OF A STRUCTURE WHICH IS LOCATED OUTSIDE THE LINES, GRADES OR GRADING SECTIONS ESTABLISHED FOR THIS PROJECT, EXCEPT WHERE SUCH EXCAVATION OR REMOVAL IS PROVIDED FOR
IN THE CONTRACT, PLANS OR SPECIFICATIONS.
27. THE CONTRACTOR SHOULD VERIFY THE QUANTITIES AND LENGTHS OF MATERIALS SHOWN ON THE PLANS. ANY DISCREPANCY BETWEEN MATERIAL CALLOUTS AND ACTUAL SHOWN IN PLAN VIEW IS TO BE BROUGHT TO THE ENGINEER'S ATTENTION BY THE CONTRACTOR PRIOR TO BIDDING. IT IS THE
ENGINEER'S INTENTION TO CONSTRUCT WHAT IS SHOWN ON THE PLANS.
28. ANY DISCREPANCY BETWEEN THE DIMENSIONS AND MEASUREMENTS SHOWN ON THE PLANS AND THE ACTUAL FIELD CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ENGINEER'S ATTENTION. FAILURE TO DO SO AND TO CONTINUE CONSTRUCTION SHALL MAKE THE CONTRACTOR RESPONSIBLE FOR ALL
ERRORS AND NECESSARY CORRECTIONS THAT MAY SUBSEQUENTLY ARISE.
8. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS AND ALL REGULATIONS CONTROLLING POLLUTION OF THE ENVIRONMENT.
9. THE CONTRACTOR SHALL DEVELOP AND IMPLEMENT A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) ACCORDING TO EPA/FDEP NPDES CRITERIA TO MINIMIZE EROSION AND INSURE PROPER FUNCTIONING OF STORM WATER MANAGEMENT SYSTEM UPON COMPLETION OF CONSTRUCTION. IN ADDITION TO MEETING EPA/FDEP NPDES CRITERIA, THE SWPPP SHALL BE SUBMITTED TO AND COMPLY WITH LOCAL AGENCY (POLK COUNTY) HAVING JURISDICTION'S
MINIMUM EROSION CONTROL CRITERIA.
10. CONTRACTOR SHALL EXECUTE ALL MEASURES NECESSARY TO LIMIT THE TRANSPORTATION OF SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT TO THE VOLUME AND AMOUNT AS THOSE THAT EXIST PRIOR TO COMMENCEMENT OF CONSTRUCTION. THIS CONDITION MUST BE SATISFIED UNTIL PROJECT IS FULLY COMPLETED AND ACCEPTED. CONTRACTOR SHALL PROVIDE ROUTINE MAINTENANCE ON TEMPORARY EROSION CONTROL FEATURES AT HIS EXPENSE. PROVISION MUST BE MADE TO PRESERVE THE INTEGRITY AND CAPACITY OF CHECK WEIRS, SEDIMENT BASINS, SLOPE DRAINS, GRADING PATTERNS, ETC. REQUIRED TO MEET THIS PROVISION THROUGH OUT THE LIFE OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE HAY BALES, SILT BARRIERS, MURAFI FILTERS, TEMPORARY GRASSING, ETC., AS REQUIRED TO FULLY COMPLY WITH THE INTENT OF THIS SPECIFICATION. CONTRACTOR SHALL PROVIDE CONTINUOUS MONITORING OF EROSION AND SEDIMENT CONTROLS TAKEN AND SHALL DOCUMENT ALL CORRECTIVE MEASURES. A COPY OF THE APPROVED SWPPP SHALL BE KEPT ON SITE AT ALL TIMES FOR REVIEW BY OWNER'S REPRESENTATIVE AND BY NPDES INSPECTORS. THIS PERMIT MUST BE SUBMITTED TO POLK COUNTY BY THE CONTRACTOR PRIOR TO THE ISSUANCE OF PERMITS.
11. THE OWNER AND/OR CONTRACTOR SHALL PROVIDE A NOTICE OF INTENT IN ACCORDANCE WITH CRITERIA SET FORTH IN THE NPDES PERMIT
REQUIREMENTS 48 HOURS PRIOR TO BEGINNING CONSTRUCTION, CLEARING, OR DEMOLITION.
12. PROVIDE EFFECTIVE TEMPORARY AND PERMANENT EROSION CONTROL FOLLOWING THE REQUIREMENTS IN SECTION 104 OF THE STATE DEPT. OF TRANSPORTATION STANDARDS SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION (F.D.O.T. SECTION 104) AND FDOT EROSION AND
SEDIMENT CONTROL MANUAL AND THE FDEP NPDES REGULATIONS.
13. INLETS AND CATCH BASINS SHALL BE PROTECTED FROM SEDIMENTATION RESULTING FROM SURFACE RUNOFF UNTIL COMPLETION OF ALL CONSTRUCTION OPERATION THAT MAY CAUSE SEDIMENT RUNOFF. FILTER FABRIC SHALL BE PLACED AND MAINTAINED UNDER THE GRATE AND FILTER SOCKS PLACED IN
FRONT OF THE THROAT OF CURB INLETS, DURING CONSTRUCTION.
14. TURBIDITY BARRIERS MUST BE INSTALLED AT ALL LOCATIONS WHERE THE POSSIBILITY OF TRANSFERRING SEDIMENTS AND SUSPENDED SOLIDS INTO THE RECEIVING WATER BODY EXISTS DUE TO CONSTRUCTION. TURBIDITY BARRIERS SHALL REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED, SOILS ARE
STABILIZED AND VEGETATION HAS BEEN ESTABLISHED.
15. ALL SLOPES 5:1 OR GREATER SHALL BE SODDED. ALL POND SLOPES AND RIGHTS-OF-WAY SHALL BE SODDED.
16. IN ACCORDANCE WITH FDEP AND WATER MANAGEMENT DISTRICT PERMITS, ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED WITHIN 7 DAYS OF NO
CONSTRUCTION ACTIVITES.
1. THE CONTRACTOR SHALL PERFORM ALL WORK PERTAINING TO DRAINAGE INCLUDING EXCAVATION OF STORMWATER MANAGEMENT PONDS OR EQUIVALENT
FACILITIES PRIOR TO THE COMMENCEMENT OF OTHER WORK INCLUDED IN THESE PLANS.
2. THE CONTRACTOR SHALL STAKE ALL IMPROVEMENTS CONTRACTOR IS TO VERIFY USE OF THE SURVEY FOR LAYOUT WITH ENGINEER PRIOR TO STARTING WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLETELY STAKE AND CHECK ALL IMPROVEMENTS TO INSURE CORRECT POSITIONING, BOTH HORIZONTAL AND
VERTICAL, PRIOR TO THE INSTALLATION OF ANY IMPROVEMENT.
3. PRIOR TO INITIATING ANY EXCAVATION CONTRACTOR SHALL INSTALL FENCES AND TAKE ALL OTHER REASONABLE AND PRUDENT STEPS TO INSURE THAT ACCESS
TO EXCAVATION BY UNAUTHORIZED PERSONNEL IS PREVENTED.
4. ALL DRAINAGE STRUCTURES ARE TO BE TRAFFIC BEARING UNLESS OTHERWISE NOTED. ALL PRECAST CIRCULAR STRUCTURES SHALL BE CONSTRUCTED WITH A
MINIMUM 5-INCH WALL THICKNESS.
5. ALL PROPOSED PAVING SURFACES IN INTERSECTIONS AND ADJACENT EXISTING SECTIONS SHALL BE GRADED TO DRAIN POSITIVELY IN THE DIRECTION SHOWN BY THE PROPOSED GRADES AND FLOW ARROWS ON THE PLANS AND TO PROVIDE A SMOOTHLY TRANSITIONED DRIVING SURFACE FOR VEHICLES WITH NO SHARP BREAKS IN GRADE, AND NO UNUSUALLY STEEP OR REVERSE CROSS SLOPES. APPROACHES TO INTERSECTIONS AND ENTRANCE AND EXIT GRADES TO INTERSECTIONS MAY REQUIRE MINOR LOCAL FIELD ADJUSTMENTS SHOULD ACTUAL CONDITIONS VARY FROM THE SURVEYED INFORMATION THE DESIGN WAS BASED UPON IN ORDER TO ACCOMPLISH THE INTENT OF THE PLANS. IN ADDITION, THE STANDARD CROWN WILL HAVE TO BE CHANGED IN ORDER TO DRAIN POSITIVELY IN THE AREA OF INTERSECTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCOMPLISH THE ABOVE AND CONSULT THE ENGINEER AS NEEDED TO MAKE ANY AND ALL REQUIRED INTERPRETATIONS OF THE PLANS OR GIVE SUPPLEMENTARY INSTRUCTIONS SHOULD THE INTENT OF THE PLANS BE UNCLEAR.
6. IF LIMESTONE BEDROCK IS ENCOUNTERED DURING EXCAVATION OF THE RETENTION BASINS OR A SINKHOLE OR SOLUTION CAVITY FORMS DURING CONSTRUCTION, EXCAVATION OF THE BASIN MUST BE HALTED IMMEDIATELY, THE OWNER, ENGINEER, AND WATER MANAGEMENT DISTRICT MUST BE NOTIFIED, AND REMEDIAL ACTION WILL BE REQUIRED. THE PERMITEE MUST INSPECT ALL PERMITTED SURFACE WATER MANAGEMENT BASINS MONTHLY FOR THE OCCURRENCE OF SINKHOLES AND DOCUMENT THESE INSPECTIONS ON WATER MANAGEMENT DISTRICT CONDITION COMPLIANCE FORM NUMBER EN-33. TWO COPIES OF THE COMPLETED FORMS MUST BE SENT TO THE WATER MANAGEMENT DISTRICT AND THE LOCAL AGENCY HAVING JURISDICTION ANNUALLY BY MAY 31ST. OF EACH YEAR. THE PERMITEE MUST REPORT ANY SINKHOLE THAT DEVELOPS WITHIN THE SURFACE WATER MANAGEMENT SYSTEM. THE PERMITEE MUST NOTIFY THE WATER MANAGEMENT DISTRICT AND LOCAL AGENCY HAVING JURISDICTION OF ANY SINKHOLE DEVELOPMENT IN THE SURFACE WATER MANAGEMENT SYSTEM WITHIN 48 HOURS OF ITS DISCOVERY AND COMPLETE SINKHOLE REPAIR WITHIN 10 DAYS OF SUCH DISCOVERY USING A DISTRICT APPROVED
METHODOLOGY.
7. AFTER THE ROADWAY HAS BEEN CONSTRUCTED TO SUBGRADE, IT SHALL BE PROOF-ROLLED TO ASSURE THAT PROPER COMPACTION HAS BEEN ATTAINED. THE PROOF-ROLLING AND COMPACTION OPERATIONS SHALL BE INSPECTED AND TESTED BY A FLORIDA LICENSED GEOTECHNICAL ENGINEER TO ASSURE THAT THE SPECIFIED COMPACTION IS MAINTAINED AND ALL DELETERIOUS MATERIALS HAVE BEEN REMOVED.
8. THE CONTRACTOR SHALL INSURE THAT A SUBGRADE AND APPROVED FILLS ARE COMPACTED TO A MINIMUM DENSITY OF 98% OF THE STANDARD PROCTOR MAXIMUM DENSITY UNLESS OTHERWISE NOTED FOR PLACEMENT OF ALL HEADWALL/ENDWALL FOOTINGS, RETAINING WALL FOOTINGS, AND IN GENERAL, ANY FOOTING SUPPORT DESCRIBED ON THESE PLANS. IT WILL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSURE THAT SUFFICIENT GEOTECHNICAL
TESTING AND DESIGN HAS BEEN PERFORMED PRIOR TO CONSTRUCTION.
9. STORM PIPE LENGTHS SHOWN ON THE PLANS INCLUDE MITERED END SECTIONS. IF THE CONTRACTOR ELECTS TO USE AN APPROVED ALTERNATE, THE PIPE
LENGTHS MUST BE ADJUSTED.
10. INLET OFFSETS ARE TO THE CENTERLINES SHOWN ON F.D.O.T. DESIGN STANDARDS INDEXES.
11. ALL REINFORCED CONCRETE PIPE (R.C.P.) SHALL BE MINIMUM CLASS III , UNLESS OTHERWISE APPROVED OR NOTED ON THE PLANS OR SPECIFICATIONS.
12. ALL STORMWATER PIPE JOINTS SHALL BE WRAPPED WITH FILTER FABRIC.
CONTRACTOR RESPONSIBILITIES
5. CONTRACTOR TO DEMOLISH AND REMOVE ALL EXISTING IMPROVEMENTS WITHIN EROSION PROTECTION BARRIER UNLESS
DIRECTED BY ENGINEER.
6. ALL ABOVE AND BELOW GROUND HARDWARE, EQUIPMENT AND MATERIALS TO BE DISPOSED OF IN ACCORDANCE WITH CITY OF
PLANT CITY REQUIREMENTS.
7. TREES SHOWN TO REMAIN SHALL MAINTAIN PROTECTIVE BARRIERS DURING DEMOLITION. THESE BARRIERS SHALL BE IN
ACCORDANCE WITH CURRENT CITY OF PLANT CITY STANDARDS.
8. THE CONTRACTOR SHALL UTILIZE SUITABLE EROSION CONTROL DURING DEMOLITION.
DEMOLITION AND CLEARING
1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL CLEARLY DESIGNATE THE LIMITS OF CONSTRUCTION ON-SITE. THE CONTRACTOR SHALL NOT PERFORM ANY
WORK OUTSIDE THE LIMITS OF CONSTRUCTION.
2. THE CONTRACTOR SHALL BE EXTREMELY CAUTIOUS WHEN WORKING NEAR TREES THAT ARE TO BE SAVED, WHETHER SHOWN IN THE PLANS OR DESIGNATED IN
THE FIELD.
3. ALL PRACTICAL AND NECESSARY EFFORT SHALL BE TAKEN DURING CONSTRUCTION TO PREVENT UNNECESSARY TREE REMOVAL.
4. IN AREAS REQUIRING FILL MATERIAL, THE CONTRACTOR SHALL STRIP OR OTHERWISE REMOVE ALL VEGETATION SUCH AS BRUSH, HEAVY SODS, HEAVY GROWTH OF GRASS, DECAYED VEGETATION MATTER, RUBBISH AND ANY OTHER DELETERIOUS MATERIAL BEFORE EMBANKMENT IS PLACED. IMMEDIATELY PRIOR TO THE PLACING OF FILL MATERIAL, THE ENTIRE AREA UPON WHICH FILL IS TO BE PLACED, SHALL BE SCARIFIED IN A DIRECTION APPROXIMATELY PARALLEL TO THE AXIS OF FILL. THE GEOTECHNICAL ENGINEER SHALL APPROVE THE AREA PRIOR TO THE PLACEMENT OF FILL.
Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
/0
4/
:4 0:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
.D W
G
C1.4 X
GENERAL NOTES AND
LEGEND
PROPOSED MAJOR CONTOURS
PROPOSED MINOR CONTOURS
EXISTING CONTOUR ELEVATION
PROPOSED CONTOUR ELEVATION
"X" ON TREE = EXISTING TREE
TO BE REMOVED (TYPICAL)
PROPERTY BOUNDARY
WETLAND LINE
EXISTING TRAIL
RECLAIMED WATER LINE
PROPOSED CULVERT
GEOCELL REINFORCED SPILLWAY
EXISTING CONTOURS
102.0
R
MASTER LEGEND
X
FLORIDA BERM PEDESTRIAN RAMP
SILT FENCE/ LIMIT OF CONSTRUCTIONSLT
TURBIDITY BARRIER
TREE BARRICADE / LIMIT OF
CONSTRUCTION
PIPE, VALVES, AND FITTING NOTES:
1. DUCTILE IRON PIPE SHALL CONFORM TO ANSI/AWWA A21.51/C151. PIPE SHALL BE PRESSURE CLASS 350 FOR 3-INCH TO 12-INCH, PRESSURE CLASS 250 FOR 16-INCH TO 20-INCH. JOINTS FOR BURIED DUCTILE IRON PIPE SHALL BE PUSH-ON OR MECHANICAL JOINTS CONFORMING TO ANSI/AWWA A21.11/C111. FLANGED JOINTS SHALL BE PROVIDED FOR ABOVEGROUND PIPING. FLANGED JOINTS SHALL CONFORM TO AWWA C115. SEE BELOW FOR
RESTRAINED JOINT REQUIREMENTS.
2. FITTINGS SHALL BE MECHANICAL JOINT DUCTILE IRON FITTINGS IN ACCORDANCE WITH AWWA C110 OR C153.
3. DUCTILE IRON PIPE AND FITTINGS SHALL HAVE AN INTERIOR PROTECTIVE LINING OF CEMENT-MORTAR WITH A SEAL COAT OF ASPHALTIC MATERIAL IN ACCORDANCE WITH AWWA C104. EXTERIOR DUCTILE IRON PIPE SHALL BE COATED WITH ASPHALTIC MATERIAL IN ACCORDANCE WITH A MINIMUM ON MIL
THICKNESS IN ACCORDANCE WITH AWWA C151.
4. ADDITIONAL APPLIED EXTERIOR COATINGS FOR ABOVEGROUND PIPE AND FITTINGS SHALL BE APPLIED. PIPE, FITTINGS, AND VALVES SHALL BE THOROUGHLY CLEANED AND GIVEN ONE FILED COAT (MINIMUM 1.5 MILS DRY THICKNESS) OF RUST INHIBITOR PRIMER IN ADDITION TO THE FACTORY APPLIED COAT OF RUST INHIBITOR PRIMER. INTERMEDIATE AND FINISHED FIELD COATS OF ALKYD SHALL ALSO BE APPLIED BY THE CONTRACTOR TO MINIMUM 1.5 MIL DRY THICKNESS FOR EACH COAT. PRIMER AND FIELD COATS SHALL BE COMPATIBLE AND BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE FINAL FILED COAT SHALL BE PANTONE 522C PURPLE FOR FINISHED RECLAIMED WATER.
5. VALVES SHALL BE RESILIENT SEAT GATE VALVES, MANUFACTURED TO MEET OR EXCEED THE REQUIREMENTS OF AWWA C515, LATEST REVISION.
VALVES SHALL HAVE AN UNOBSTRUCTED WATER WAY EQUAL TO OR GREATER THAN THE FULL NOMINAL DIAMETER OF THE VALVE. VALVES SHALL HAVE
A MINIMUM PRESSURE RATING OF 150 PSI.
6. VALVES SHALL BE NON-RISING STEMS WITH THE STEM MADE OF CASE, FORGED, OR ROLLED BRONZE AS SPECIFIED IN AWWA C515. TWO STEM SEALS SHALL BE PROVIDED AND SHALL BE OF THE O-RING TYPE. THE STEM NUT MUST BE INDEPENDENT OF THE GATE.
7. PIPE SHALL BE CLEANED THROUGH A FULL DIAMETER PRELIMINARY FLUSH FOLLOWED BY SWABBING (ALSO KNOWN AS PIGGING) FOLLOWED BY PRESSURE TESTING AND DISINFECTION. PROCEDURES FOR CLEANING, PRESSURE TESTING, AND DISINFECTION SHALL BE IN ACCORDANCE WITH AWWA
C600, C605, AND C651.
W1
4:1 FLOW DIRECTION AND SLOPE
WETLAND CELL
IDENTIFICATION
PERCOLATION CELL
IDENTIFICATIONR1
TOPOGRAPHIC
BENCHMARK
MITERED END SLOPE (M.E.S.)
DITCH BOTTOM INLET (DBI)
EXISTING CULVERT
MANHOLE
8. FLORIDA LAW (F.S.556) UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT MANDATES THAT EXCAVATORS/CONTRACTORS SHALL CONTACT SUNSHINE 811 (FKA: SUNSHINE STATE ONE-CALL OF FLORIDA) BY CALLING 800-4432-4770 OR 811 AT LEAST 2 FULL BUSINESS DAYS PRIOR TO BEGINNING ANY EXCAVATION OR DEMOLITION TO ALLOW MEMBER OPERATORS AN OPPORTUNITY TO IDENTIFY AND MARK THEIR UNDERGROUND FACILITIES AND
APPROPRIATELY RESPONSE TO THE POSITIVE RESPONSE SYSTEM.
9. UTILITY SERVICES TO THE PROPOSED BUILDING(S) SHALL TERMINATE 5 FEET OUTSIDE OF THE BUILDING UNLESS OTHERWISE NOTED. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL REVIEW BUILDING ARCHITECTURAL AND PLUMBING PLANS TO VERIFY PROPER CONTINUATION OF THE PROPOSED UTILITIES FOR LOCATION, ALIGNMENT AND ELEVATION(S) FOR EACH SERVICE TO THE BUILDING(S). SHOULD UTILITY SERVICE LATERALS SHOWN ON THE SITE CIVIL CONSTRUCTION PLANS NOT CORRESPOND WITH BUILDING ARCHITECTURAL OR PLUMBING PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER
IMMEDIATELY.
© 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS © 2022 TomTom
© 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS
Legend of Symbols & Abbreviations Professional Surveyor and Mapper Identification Licensed Business
Corrugated Metal Pipe Polyvinyl Chloride Pipe Ductile Iron Pipe
Temporary Benchmark Temporary Benchmark
Spot Elevation Number
Cypress Palm Oak Unknown Tree Pine
Underground Drainage Pipe Guardrail
Centerline of Railroad Tracks
Topographic & Tree Survey McIntosh Park Phase 2
Sections 4, 5, 8 & 9, Township 28 South, Range 22 East Hillsborough County, Florida
Vicinity Map
SHEET 6
SHEET 2
SHEET 3
SHEET 4 SHEET 5
Surveyor's Notes
Address: 775 East Knights-Griffin Road Project Name: McIntosh Park Phase 2 - Topographic & Tree Survey Project No.: 20200005
City: Plant City
REVISION DATE INITIALS SurVEYING Today With Tomorrow's technology
Date Drafted: 08/11/20 Drafted By: K. Quibell, B. Stinson
Approved By: S. Brown Date Approved: 09/15/20
Drawing Name: 20200005_2T Phase: 2
Field Book/Page: 20-11/61 Last Field Date: 07/24/20
State: Florida
Survtech Solutions, Inc.
East Knights-Griffin Road
C
SX R
ailroad
1. The horizontal datum utilized for this project is NAD 1983 Florida West Zone, 2011 Adjustment, U.S. Survey Feet. Said datum was established by utilizing the Florida Permanent Reference Network (FPRN).
2. The vertical datum utilized for this project is NAVD 1988, U.S. Survey Feet. The benchmarkutilized was National Geodetic Survey (NGS) Control Station "18311" with an elevation of 103.92 feet.
3. Surveyor makes no guarantees as to the species of trees or to the health of each tree depicted hereon, if this information is necessary a certified arborist should be contacted.
4. The trees shown hereon were located utilizing methods adequate for their accurate location and identification. However, this company and the signing surveyor resertves the right to verify the location of all trees critical to the design of buildings, parking and other permanent features. It is the responsibility of the design professional to inform this company and/or the signing surveyor of any trees critical to their design so that those trees can be verified prior to the completion of the design.
5. Only those trees within the "Approximate Limits of Collected Trees" were collected at the time of field survey. There may be other trees outside of these limits within the Parent Parcel not depicted hereon.
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
/0
4/
:4 0:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
SU
R
VE
Y
C O
N
TR
O L
SH
EE
T.
D
W G
C4.1 X
SURVEY CONTROL
400'0' 800'
SCALE: 1" = 400'
200'
ALL SURVEY DATA ON THIS SHEET PROVIDED BY SURVTECH SOLUTIONS, INC.
R
R R
R R
R R
R R R R R R R R R R R R
R
R
R
R
R
R
R
R
R
R
R R
R
R R
R R
R R
R R
R R
R R
R
E KNIGHTS GRIFFIN ROAD
N A
LE
XA
N D
ER
S
T
SR
EAST C
AN
AL
EAST C
AN
AL
PROPERTY LINE
PROPERTY LINE
WETLAND LINE
WETLAND LINE
SITE ENTRANCE
EXISTING
ACCESS ROAD
WETLAND LINE
EXISTING 30"
RECLAIMED
WATER MAIN
EXISTING 24"
RECLAIMED
WATER MAIN
CSX RAILROAD
RIGHT-OF-WAY
EXISTING EAST
CANAL WEIR
EPC
MITIGATION
AREA
EXISTING WELL
EXISTING WELL
WETLAND LINE
EXISTING
PARKING LOT
EXISTING PARK
TRAILS EXISTING PARK
TRAILS
EXISTING ALUM.
PONDS
EXISTING
STORMWATER
TREATMENT
WETLAND
APPROXIMATE LIMITS
OF COLLECTED TREES
APPROXIMATE LIMITS
OF COLLECTED TREES
APPROXIMATE LIMITS
OF COLLECTED TREES
EXISTING ALUM
BUILDING
EXISTING
MAINTENANCE
COMPOUND
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
/0
3/
0:
:0
AM
Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
PL
AN
.D
W G
200'0' 400'
SCALE: 1" = 200'
100'
C4.2 X
EXISTING CONDITIONS
LEGEND
PROPERTY LINE
WETLAND LINE
MITIGATION LINE
OAK TREE
PINE TREE
PALM TREE
UNKNOWN
CYPRESS TREE
VEGETATION
APPROXIMATE CANAL
TOP OF BANK
N
LE
XA
N D
ER
S
T
SR
R
R R
R R
R R
R R R R R R R R R R R R
R
R
R
R
R
R
R
R
R
R
R R
R
R R
R R
R R
R R
R R
C
SX
R
IG
H T
O F
W
AY
E KNIGHTS GRIFFIN ROAD
EAST C
AN
AL
EAST C
AN
AL
EXISTING PARK TRAILS
E2
C2
C1
W2
W1
SITE ENTRANCE
30" RECLAIMED
WATER MAIN
R3
PROPERTY LINE
R1
R2
EXISTING WELLS
ENCLOSURE
R4
E1
E3
FLORIDA MOUND
EXISTING
WEIR
EXIST BUILDING
EXIST WELL
PROPOSED
OFFICE/BATHROOM
BUILDING &
HANDICAPPED PARKING
PROPOSED
PAVILION
PROPOSED
BOARDWALK
PROPOSED
PARKING AREA
EXISTING
WETLAND
"Y"
EXISTING
WETLAND
"Z"
EXISTING
WETLAND
"X"
EXISTING
WETLAND
"AB"
EXISTING
WETLAND
"M"
/0
6/
:1 7:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
O
VE
R
AL
L
SI
TE
P
LA
N
.D W
G
200'0' 400'
SCALE: 1" = 200'
100'
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
C4.3 X
OVERALL SITE PLAN
FOR WORK IN THIS AREA
SEE SHEETS C4.4 & C4.8
FOR WORK IN THIS AREA
SEE SHEETS C4.5 & C4.9
FOR WORK IN THIS AREA
SEE SHEETS C4.6 & C4.10
FOR WORK IN THIS AREA
SEE SHEETS C4.7 & C4.11
LEGEND
WETLAND CELL
PERCOLATION CELL
PROPERTY LINE
EXISTING TRAIL
E2 WETLAND CELL DESIGNATION
NOTE: WETLAND CELL DESIGNATION FROM
MCINTOSH PARK INTEGRATED
WATER MANAGEMENT PLANS
R=100.00' L=37.92' Δ=021°43'33"
.0
0'
.0 0'
20.00
.0
.0
80.00 90.00 80.00
100.00 100.00
100.00 100.00
100.00 100.00
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
10.00
10.00
10.00
10.00
10.00 10.00 10.00
10.00 10.00
12.00 12.00 20.00
12.00 12.00
.0
.0
.0
0'
.1
4'
.0 0'
.0
0'
S41°09'40.41"E 254.00'
S41°09'40.41"E 254.00'
S41°09'40.41"E 254.00'
N87 °0
6'4 6.0
2" E
.12
R=32.00' L=21.38' Δ=038°16'26"
R=15
R=15
R=10
TYP
R=10
TYP
R=10
TYP
R=10
TYP
R=3
TYP
N
°5 0'
.5
9" E
N
°5 0'
.5
9" E
S41°09'40.41"E 195.02'
R=60.00' L=137.56' Δ=131°21'52"
N89 °4
7'4 8.3
0" W
.17
R=15
R=15
R=300
R=3
TYP
R=3
TYP
R=3
TYP
R=3
TYP
R=3
TYP
/0
6/
:1 7:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
O
VE
R
AL
L
SI
TE
P
LA
N
.D W
G
20'0' 10' 40'
SCALE: 1" = 20'
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
C4.4 X
PARKING AREA
DIMENSION PLAN
MATCH LINE SEE SHEET
C4.5 FOR CONTINUATION
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
LEGEND
PROPOSED CRUSHED STONE
R4
E3
NOTE:
THERE MAY BE EXISTING TREES LOCATED WITHIN THE
PROPOSED PARKING/POND AREA THAT WILL NEED TO
BE REMOVED. CONTRACTOR TO FIELD VERIFY PRIOR
TO CONSTRUCTION. LARGE CALIPER TREES TO BE
IDENTIFIED PRIOR TO COMMENCEMENT OF
CONSTRUCTION. PARKING ISLANDS MAY NEED TO BE
FILES ADJUSTED TO RETAIN LARGE CALIPER TREES.
PROPOSED
RETENTION
AREA
EXIST. EXIT
EXIST. ENTRANCE
10 10
8 89
WHEEL STOPS (TYP)
WHEEL STOPS (TYP)
WHEEL STOPS (TYP)
WHEEL STOPS (TYP)
WHEEL STOPS (TYP)
PROPOSED PARKING = 155 SPACES
EXISTING
WETLAND
"Y"
(TO REMAIN
UNDISTURBED)
EXISTING
WETLAND
"M"
(TO REMAIN
UNDISTURBED)
PROPOSED CRUSHED STONE
WETLAND PERMITTED TO BE
IMPACTED PER SWFWMD ERP
43044733.002 AND EPC REVIEW
NUMBER 79173
20.00
12.00
12.00 12.00
12.00 12.00
12.00 12.00
12.00
12.00
12.00
12.00
12.00
5.00
5.00
5.00
10.00
10.00
.0
.0
.0
R=15
R=15
S3 2°
'07
.5 4"
W
.3
3'S57°05'52.46"E 68.00'
S57°05'52.46"E 68.00'
R=100.00' L=37.92' Δ=021°43'33"
S68°28'39.14"W62.33'R=100.00' L=37.56' Δ=021°31'21"
N90°00'00.00"W 23.99'
R=100.00' L=46.22' Δ=026°28'56"
N63°31'03.83"W
29.62'
R=120.00' L=175.05' Δ=083°34'49"
20.00
5.00
/0
6/
:1 7:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
O
VE
R
AL
L
SI
TE
P
LA
N
.D W
G
20'0' 10' 40'
SCALE: 1" = 20'
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
C4.5 X
PARKING AREA
DIMENSION PLAN
M
AT
C H
L
IN
E
SE
E
SH
EE
T
C 4.
FO
R C
O N
TI
N
U
AT
IO
N
EXIST PARKING WHEEL STOPS TO
BE REMOVED AND REUSED IN THE
HANDICAPED PARKING AREA.
EXIST TRAIL
PROPOSED HEADER CURB (TYP)
EXIST TOP OF BANK
EXIST TOP OF BANK
EXPANDED WETLAND E3
10' SIDEWALK
LEGEND
PROPOSED CRUSHED STONE
PROPOSED HEADER CURB (TYP)
PROPOSED HEADER CURB (TYP)
PROPOSED ASPHALT
PROPOSED HANDICAP RAMP CR-A (TYP)
10' SIDEWALK
5' SIDEWALK (TYP)
PROPOSED BUILDING
(OFFICE/BATHROOMS)
(SEE DETAILS ON SHEET C5.2)
(SEE STRUCTURAL SHEETS FOR DETAILS)
R4
E3
PROPOSED CONCRETE
PROPOSED
RETENTION
AREA
NORTHING : 1359666.17'
EASTING : 615792.78' S 57°05"52.46" E
FOR HANDICAP PARKING STRIPING
SEE DETAIL ON SHEET C5.1
RELOCATED WHEEL STOPS (TYP)
WETLAND PERMITTED TO BE
IMPACTED PER SWFWMD ERP
43044733.002 AND EPC REVIEW
NUMBER 79173
NOTE:
THERE MAY BE EXISTING TREES LOCATED WITHIN
THE PROPOSED PARKING/BUILDING/RETENTION AREA
THAT WILL NEED TO BE REMOVED. CONTRACTOR TO
FIELD VERIFY PRIOR TO CONSTRUCTION.
PROPOSED PARKING = 12 HANDICAPED SPACES
EXIST WETLAND O
EXIST
STORMWATER
TREATMENT
WETLAND ESTW
/0
6/
:1 7:
P
M Q
:\C
IT
Y O
F
PL
AN
T
C
IT
Y\ M
C
IN
TO
SH
P
AR
K
EL
EM
EN
TS
(F
IN
AL
D
ES
IG
N
)\C
AD
\D W
G \5
O
VE
R
AL
L
SI
TE
P
LA
N
.D W
G
20'0' 10' 40'
SCALE: 1" = 20'
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SCALE
OF
50183029
X
LKW
JDP
AM
September 11, 2025
FL
O
R
ID
A
PL
AN
T
C
IT
Y, M C
IN
TO
SH
PA
R K
EL
EM
EN
TS
C
IT
Y O
F
PL
AN
T
C
IT
Y U
TI
LI
TI
ES
D
EP
AR
TM
EN
T
SEAL
C4.6
PAVILION PLAN
EXIST TRAIL
FLORIDA MOUND
PROPOSED 30'x64' PAVILION
MANUFACTURE :POLIGON
BUILDING TYPE : REK 30x64
ROOF TYPE: MULTI-RIB
(FOR PAVILION DETAILS SEE SHEET C5.3)
(SEE STRUCTURAL SHEETS FOR DETAILS)
NORTHING : 1358868.97'
EASTING : 615515.26'
30'
64' N 90°00'00" E
LEGEND
EXIST TRAIL
PROPOSED CONCRETE
C2
EXIST
WETLAND T
WETLAND PERMITTED TO BE
IMPACTED PER SWFWMD ERP
43044733.002 AND EPC REVIEW
NUMBER 79173
N62°41'20.31"E 110.00'
N90°00'00.00"E 241.73'
N27°18'39.6…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .